Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC 2 65 GORWA UDAYPARK SOCIETY REFINERY ROAD VILLAGE TOWN VADODARA CITY VADODARA VADODARA GUJARAT 390016 INDIA | VADODARA | GUJARAT | 390016 | ₹1.5 Cr | L1 | Accepted-AOC Release of EMD |
| 2 | L2₹1.7 Cr+₹23.0 L (15.3%)Rejected-Finance C 256 NEW ASHOK NAGAR DELHI 110096 | EAST | DELHI | 110096 | ₹1.7 Cr+₹23.0 L (15.3%) | L2 | Rejected-Finance Rejected due to L2 |
| 3 | L3₹1.9 Cr+₹36.8 L (24.5%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | ₹1.9 Cr+₹36.8 L (24.5%) | L3 | Rejected-Finance Rejected due to L3 |
Tender Value
Refer Docs
EMD Value
₹4.3 L
Closing Date
17 Apr 2023, 6:00 pmClosed
Asst. eneral Manager (Engg-E)
O/o Asst. General Manager (Engg-E) AAI, Kolhapur Airport, Kolhapur
Extension of Runway with Blast pad, RESA, Taxiway apron, GSE Area, Isolation Bay, New Domestic Terminal Building and miscellaneous works at Kolhapur Airport. SH Shifting of GLF system for existing CCR to New CCR room, connection to the new ATC Tower
2023_AAI_150227_1
AAI/KOP/ENGG-E/NIT-03/2023-24
Open Tender
Electrical Works
Item Rate
60 days
Kolhapur Airport
Please refer Tender Documents.
6 documents required · 6 mandatory
₹1,180
Yes
₹4.3 L
Yes
12 Dec 2023
27 Mar 2023
19 Apr 2023
27 Mar 2023
17 Apr 2023
27 Mar 2023
27 Mar 2023 - 6 Apr 2023
Amount
Supply of 2.5 sq.mm 61 core armoured 650/ 1100V grade copper control cable XLPE insulated as per IS 7098 (Part-I) with ammendments up to date for Remote control panel etc complete as required.
Supply of 2.5 sq.mm 10 core armoured 650/ 1100V grade copper control cable XLPE insulated as per IS 7098 (Part-I) with ammendments up to date for Remote control panel etc complete as required.
Supply of 6 sqmm. PVC insulated & PVC Sheathed Stranded copper conductor single core airfield lighting cable of 5KV grade confirming to IS 1554 Part-II with upto date amendement s as required and conforming to particuar specifications.
Supply of 16 sqmm. PVC insulated & PVC Sheathed Stranded copper conductor single core airfield lighting cable of 5KV grade confirming to IS 1554 Part-II with upto date amendement s as required and conforming to particuar specifications.
Supply of 2 x 4 sq.mm size secondary lead made out of multi stranded copper conductor, EPR insulalted PCP sheathed, treated 600V grade cable as specified in particular specification and as required.
Supply of following sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 1.1 KV grade conforming to IS 7098 (Part 2) amended upto date : a) 3.5 X 25Sq.mm Aluminiun conductor cable
Supply of following sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 1.1 KV grade conforming to IS 7098 (Part 2) amended upto date : a) 3.5 X 95Sq.mm Aluminiun conductor cable
Supply of following sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 1.1 KV grade conforming to IS 7098 (Part 2) amended upto date : a) 4C X 6Sq.mm Aluminiun conductor cable
Supplying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete as required. 63 mm Dia
Supplying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete as required. 100 mm Dia
Laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (80 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia
Laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (80 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 100 mm dia
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipes as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheated / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipes as required. Above 35 sq. mm and up to 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.(for control cable of 61core) Above 95 sq. mm and up to 185 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required Upto 35 sq. mm (clamped with 1mm thick saddle)
Kerfs cutting with machine in runway /taxiway of bituminous surface of suitable depth and width for secondary cable, laying of cable, and refilling the same with cement mortor and finishing with sealent material etc complete as required.
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing cable as required
Supply of 5 KV, Cu grade plug and receptacle of type I class "B" connector suitable for field attachment with 5 KV grade PVC insulated PVC sheathed single core 6 Sq.mm copper conductor cable conforming to the relevant IS specification etc. complete as required
Supply of 5 KV, Cu grade plug and receptacle of type I class "B" connector suitable for field attachment with 5 KV grade PVC insulated PVC sheathed single core 16 Sq.mm copper conductor cable conforming to the relevant IS specification etc. complete as
Supply of 600 V grade plug and receptacle of type II, class 'B' connector and suitable field attachment with EPR insulated, PCP sheathed, two core copper conductor secondary cable 4 sq.mm as required.
Making field connections by crimping 6 Sq.mm or 16Sq.mm plug and receptacle with existing single core PVC copper conductor PVC insulated, PVC sheathed cable/XLPE cable including filling the gap with water sealing compound, applying HT insulation tape, over which PVC tape etc. as required
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Supply installation of FRP fully weather protected outdoor feeder box (IP65) having a cable entry of minimum 35 Sq. mm with TPN 40A 25 KVA MCCB as required. (for WDI LDI cable joint )
Supply of 15 Watts 6.6/6.6 Amps 5KV grade 50 Hz series type isolating transformer conforming to relevant IS, encapsulated in polyster resin finally moulded with neoprene type rubber with primary & secondary connections as specified in particular specifications complete as required.
Supply of cast iron isolating Transformer housing box, water tight round type, metal container of outside size 330 mm dia, height 450 mm made of 10 mm thick cast iron moulding all round, except the top surface, which is 15 mm thick, cast iron moulding suitable to receive a light fitting base plate on the top and underground housing associated with transformer, power cable and having two holes opposite as per site requirement at the periphery, centre 75 mm above bottom surface suitable to receive 50 mm dia HDPE/medium class G.I pipe and one no of suitable hole to receive 15mm B class G.I pipe for loop earthing as required as required. The box should have two SS earh bolts of M10x40 mm tapped inside near the hole (4" away from hole centre) and having drain hole at the bottom suitably tapped to receive 15mm dia GI pipe and having clear opening of 220 mm at the top surface and 06 Nos. M10 tapped hole having centre to centre distance of 260mm alongwith bolts as required as per the drawings. Double Hole CI Housing Box
Installation of Transformer Housing Box with a base concrete of 1:3:6 of size 630x630x100mm thick all round concrete of 1:2:4, 150mm thick, the top sloppedd with 1:2:4 cement concrete including providing and fixing 250mm long 15mm dia. "B" class GI pipe with check nut for drainage of water including excavation of side shoulder and refilling etc. complete as required.
Supply of FAA and ICAO complied inset type Omni directional 8" dia, medium intensity LED Taxi light complete with vulcanised plug for connection to isolating transformer, lamp holder assembly , blue prism with stopper & gaskets, O-ring, washers , brass cable gland assembly, upper and lower cover etc and all other accessories complete as required complying with relevant FAA and ICAO standards.
Supply of FAA and ICAO complined LED lamp& Driver assembly for Inset fitting taxi way light fitting complete as required.
Inset fitting spares Prismatic Blue lens
Installation testing commissioning of Remote control pannel Cum display unit at control tower suitable for remote operation of constant current regulators and comprise of the following including interconnections etc. With terminal block etc. complete as required.
Installation testing and commissioning of Crash siren (Horizontal Double mounting carbon brush less AC motor) along with wiring (Supply and Laying) with 2.5Sq.mm X 3 C FRLS copper cable on existing cable tray or Wall along with fixing of 10A DP MCB in industrial MCB Box including termination with proper lugs and installation of push siren button . suitable for operation at 240V 50 hz AC supply and audible range range should of 3 Km.
Installation testing commissioning of Rotating beacon on top ATC tower with suitable civil foundation as per OEM specifications along with wiring (Supply and Laying) with 2.5Sq.mm X 3 C FRLS copper cable on existing cable tray or Wall along with fixing of 10A DP MCB in industrial MCB Box including termination with proper lugs etc as per specifications complete as required.
Dismantalling, Shifting and re-installation of the following capacity microprocessor based CCR along with transportation from old power house to CCR room of new power house including securing and fixing with proper nut and bolts input and output cable connections , providing connection and required connector and other sundry items testing and comissioning etc. complete (reistallation at New CCR room includes required fabrication work like cutting of MS Chequred plate, making suitable frame with MS angle/ channel as required for installing CCR) as required. 4 kw
Dismantalling, Shifting and re-installation of the following capacity microprocessor based CCR along with transportation from old power house to CCR room of new power house including securing and fixing with proper nut and bolts input and output cable connections , providing connection and required connector and other sundry items testing and comissioning etc. complete (reistallation at New CCR room includes required fabrication work like cutting of MS Chequred plate, making suitable frame with MS angle/ channel as required for installing CCR) as required. 7.5 kw
Dismantalling, Shifting and re-installation of the following capacity microprocessor based CCR along with transportation from old power house to CCR room of new power house including securing and fixing with proper nut and bolts input and output cable connections , providing connection and required connector and other sundry items testing and comissioning etc. complete (reistallation at New CCR room includes required fabrication work like cutting of MS Chequred plate, making suitable frame with MS angle/ channel as required for installing CCR) as required. 20 Kw
Installation, Testing and Commissioning of inset fitting with core cutting, aligning and setting i/c providing sealing material and installation of Isolating Transformers, Crimping / Jointing of Plug receptacles, laying of secondary lead in existing GI pipe in groove i/c cutting and sealing of groove and other accessories required for commissioning i/c supply of all materials except fixture, secondary lead, plug and receptacles and isolating transformer etc. as required.
Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
YPR ENGINEERING AND SOLUTIONS PRIVATE LIMITED
Manish Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .