| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.6 LAccepted-AOC NABA MISHRA COLONY HATATOTA TALCHER DIST ANGUL PIN 759100 | TALCHER | ANGUL | ODISHA | 759100 | ₹2.6 L Quoted ₹2.2 L | L-1 | Accepted-AOC Awarded due to becoming techno-commercially eligible L-1 bidder. |
| 2 | L-2₹2.4 L+₹13,685 (6.17%)Rejected-Finance | ₹2.4 L+₹13,685 (6.17%) | L-2 | Rejected-Finance Rejected due to not becoming techno-commercially eligible L-1 bidder. |
| 3 | L-3₹3.7 L+₹1.5 L (68.7%)Rejected-Finance AT SAMET ELECTRO TOWER TAMRIT MARKET COMPLEX ROOM NO 15 HATATOTA TALCHER DIST ANGUL ODISHA PIN 759100 | TALCHER | ANGUL | ODISHA | 759100 | ₹3.7 L+₹1.5 L (68.7%) | L-3 | Rejected-Finance Rejected due to not becoming techno-commercially eligible L-1 bidder. |
| 4 | L-4₹3.8 L+₹1.6 L (72.6%)Rejected-Finance AK PO GHANTAPADA TALCHER ANGUL ODISHA | TALCHER | ANGUL | ODISHA | ₹3.8 L+₹1.6 L (72.6%) | L-4 | Rejected-Finance Rejected due to not becoming techno-commercially eligible L-1 bidder. |
Tender Value
₹4.1 L
EMD Value
₹5,200
Closing Date
6 Feb 2023, 5:00 pmClosed
Staff Officer(EnM), Jagannath Area, MCL
Jay Prakash, Staff Officer(EnM), Jagannath Area, MCL PH 06760-269717, 06670-269751(Extn)2023 Fax 06760-269527 E-mail so-enm-jaga.mcl(at)coalindia.in
Complete electrical wiring and lighting at main canteen of Ananta OCP, Jagannath Area
2023_MCL_268539_1
GM(JA)/EnM/ e-Tender/2023/E-566/59 dated20/01/2023
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Talcher
AS PER NIT
4 documents required · 4 mandatory
₹5,200
Yes
3 Apr 2023
24 Jan 2023
8 Feb 2023
25 Jan 2023
6 Feb 2023
25 Jan 2023
25 Jan 2023 - 30 Jan 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supply and fixing of junction box includes 63 amp 4 pole connector with necessary connection as required.
Supply & fixing of 20 watt complete LED tube light fittings with necessary connection as required.
Supply & fixing of 20 watt surface light fittings with necessary connection as required.
Supply and installation of LT distribution panel indoor type floor mounted type,Sheet steel thickness 1.6mm, dust & vermin proof degree of protection IP 52 , siemens gray powder coated as per RAl-7032, with suitable installation of, MCCB 200 Amp 1 no, MCCB 125 Amp 1 no, 19mm X 3 mm copper busbar for connection (1.5 mtr) , connector, metering unit, indication lamp etc and necessary connection as required.( 1 ft W X 1.5 ft B X 2 ft H)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Earthing with G I earth plate 600mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtrlong etc. with charcoal / coke and salt as required.
Supplying and laying 25 mm x 5 mm G I strip at 0.5 mtr below ground as strip electrode , including connection / termination with G I nut bolts , spring washer etc as required (jointing shall be done by overlapping and with two sets of G I nut bolts, spring washer at 50 mm)
Supply & fixing of 300 mm Capacitor Type propeller type ac ventilating exhuast fan with necessary connection as required.
Total impact of GST for the purpose of CTC
M/S. GAYATRI CONSTRUCTION & POWER
TARENI ELECTRICALS
SANJAY KUMAR SINGH
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .