Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 LAccepted-Finance 691 INDUSTRIAL AREA PHASE II CHANDIGARH 160 002 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160002 | L1 | Accepted-Finance Being a lowest Tender | |
| 2 | L2₹14.1 L+₹1.5 L (11.6%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L2 | Rejected-Finance Being a not lowest Tender | |
| 3 | L3₹15.2 L+₹2.5 L (19.7%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L3 | Rejected-Finance Being a not lowest Tender | |
| 4 | L4₹15.4 L+₹2.7 L (21.3%)Rejected-Finance 363 39KA HASSANGANJ BAWLI KUMAR COMPANY 363 39 KA HASAN GANJ BAWLI SAADAT GANJ LUCKNOW SAADATGANJ | L4 | Rejected-Finance Being a not lowest Tender | |
| 5 | L5₹16.6 L+₹3.9 L (31.0%)Rejected-Finance 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L5 | Rejected-Finance Being a not lowest Tender |
Tender Value
₹21.9 L
EMD Value
₹43,880
Closing Date
10 Jun 2020, 6:00 pmClosed
GE AF MC CHANDIGARH
GE (AF) MC CHANDIGARH
CERTAIN REPAIR TO INTERNAL WIRING INCLUDING REPAIR WINDING VARIOUS TYPE OF CEILING FAN EXAUST FAN AT SECTOR 47 AT BRD AF STN CHANDIGARH UNDER GE AF MC CHANDIGARH
2020_MES_338921_1
GE(AF) MC CHD-02/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CHANDIGARH
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE (AF) MC CHANDIGARH
₹43,880
Yes
CHANDIGARH
30 Jul 2020
16 Apr 2020
12 Jun 2020
16 Apr 2020
10 Jun 2020
2 Jun 2020
23 Apr 2020 - 30 Apr 2020
5 May 2020
Amount
Taking down carefully of point wiring (Light , fan, socket or power complete fittings such as switches,Ceiling roses, pendants, regulator, sockets, Bell push) removing from site of work and making good to the disturbed surfaces of walls/floors etc all as directed. NOTE :- Taking down of Light fitting, MCB, DB etc to be measured and paid separately.
Taking down carefully DB box and MCB SP/SPN/TPN of any sizes & capacity complete all as specified and directed by Engineer –in-Charge)
Point wiring using stranded copper conductor FRLS cable of size 1.5 Sqmm, PVC insulated Unsheathed complete in & including non metallic rigid PVC concealled conduit 1.6mm thick including all fittings and accessories, using new sunken pressed steel terminal boxes with frame and cover plate of suitable size for mounting of modular switches, sockets, fan regulators etc fastened with chromium plated screws and 1.5 sqmm PVC insulated stranded copper conductor FRLS cable as continues earth wire connected to common earth dolly all as directed and as specified for the following. Make of cable:-Plaza/Finolex/Havell's/Polycab. Make of conduit :- Diplast/any ISI mark heavy duty.
All as per Srl item No.3 here-in-before, but One light/fan point controlled by one switch
All as per Srl item No.3 here-in-before, but One 3-pin socket outlet 5 Amp on independent board.
All as per Srl item No.3 here-in-before, but One 3 pin socket outlet 5 Amp on same board
All as per Srl item No.3 here-in-before, but One lightl point controlled by 2, two switches
All as per Srl item No.3 here-in-before, but One bell point controlled by one switch
All as per Srl item No.3 here-in-before, but with 2.5 Sqmm copper conductor cable and 2.5 sqmm PVC insulated standard copper conductor complete FRLS cable as continuous earth wire all as specified for One 3 pin socket outlet 15 Amp on independent board.
M&L for Sub main wiring with two single core PVC insulated unsheathed stranded copper conductor FRLS cable 6 Sqmm by drawing into existing surface/ concealed conduit, PVC insulated stranded copper conductor FRLS cable 6 Sq mm as continuous earth wire conductor connected to common earth dolly and all metal part/main switch including taking down old Unserviceable submain wiring complete all as directed by Engineer-in-Charge. MAKE :PLAZA /HAVELL's/FINOLEX/NICCO NOTE :- Two runs of single core PVC insulated standarad copper conductor and one run of earth wire shall be measured as one unit.
S&F Switch modular, 1 module single pole one way 6 Amp complete all as specified & directed by Engr- in - incharge.Make:-Indo Asian/SSK/Anchor
S&F Switch modular, 1 module single pole one way 16 Amp complete all as specified & directed by Engr- in - incharge.Make:-Indo Asian/SSK/Anchor
S&F Switch modular, 1 module single pole two way 6 Amp complete all as specified & directed by Engr- in - incharge.Make:--Indo Asian/SSK/Anchor
S&FBell push modular, 1 module 6 amp single pole one way complete all as specified & directed by Engr- in - incharge.Make:- -Indo Asian/SSK/Anchor)
S&F Socket out let 3 pin 6 amp multipurpose, modular, 2module complete all as specified & directed by Engr- in - incharge.Make:-Indo Asian/SSK/Ancho
S&F Socket out let 3 pin 6/16Amp multipurpose, modular, 2 module 240 volt complete all as specified & directed by Engr- in - incharge. Make:-Indo Asian/SSK/Anchor
M&L Step regulator for ceiling fan modular type 1module of any sweep complete all as specified and directed by Engr-in-Charge. Make:- -Indo Asian/SSK/Anchor.
S&F Ceiling rose surface Bakelite 65 x 50 mm two to three terminals complete all as specified & directed by Engr- in - incharge.Make:- CONA/SSK/Anchor
S&F Bell ding dong type AC 230 Volts, Single Phase complete all as specified & directed by Engr- in - incharge. Make:- CONA/SSK/Anchor
S&F MCB single pole and neutral 240 volt 40 Amp to 63 Amp all 'C' series as specified & directed by Engr- in - incharge.Make:- Havell's/L&T/Legrand
S&F MCBs SP 240 volt 5 to 32 Amp 'C' series all as specified & directed by Engr- in - incharge.Make:- Havell's/L&T/Legrand
Supply and fixing sheet steel enclosure double door for DB SPN 240 voltS 8 way with 200 Amps rated bus bar all as specified. Make:- Havells/L&T/Legrand/Indo Asian
All as per Srl item No 16 above but 2 way single soor
Supply and fixing wall mounted fittings with ABS housing and clear polycarbonate cover inclouding retrofit LED bulb and provision of flexible copper 3core cable 0.5Sqmm from connector/ ceiling rose to fitting all as specified and conforming to City -1/City-2 Make : Havell's or equvalent to Bajaj/Crompton
Supply and fixing 04 feet 20 Watt LED Batten with extruded aluminimum housing with high quality PC diffuser colour temp, 6500K ,PF >0.9 complete all as specified and directed by Engg-in- Charge.Mae:--C&S/Phillips/CG
Supply and fixing 02 feet 10 Watt LED Batten with extruded aluminimum housing with high quality PC diffuser colour temp, 6500K ,PF >0.9 complete all as specified and directed by Engg-in- Charge.Mae:--C&S/Phillips/CG
Supply and fixing LED Bulk head Luminaire made of pressure die cast aluminium hosing with protcted diffuser 9/10 watt system wattage ,colour temp, 6500K, PF >0.9 complete all as specified and directed by Engg-in- Charge.Mae:--C&S/Phillips/CG
Supply and fixing Indoor decorative aluminium extruded 5 watt T5 LED surface mirror fixture having power factor>0.9 with diffuser and decorative end caps(6500K)complete all as specified and directed.Make:-C&S/Phillips/CG
M & L in replacement of 6201/6202/6203 ball bearing for the ceiling fan, Exhaust fan, any sweep any model complete all as specified and directed by the Engr-in-charge. Make: NBC/SKF/HRC.
M&L in replacement of capacitor 2.5/3.15 mfd for the ceiling fan, exhaust fan, of any make/model/sweep, complete . Make:- EPCOS/NICCO/USHA/UNISTAR/PRIYA.
M&L Step regulator for ceiling fan switch type of any sweep complete all as specified and directed by Engr-in-Charge.Make Bajaj/Orient/Usha/Anchor
Disconnecting and taking down the complete ceiling fan with down rod from ceiling hook/Fan box any size /make/sweep at any location for carrying out over hauling such as cleaning ,oiling,lubricating,greasing etc and refixing the ceiling fan back on the same location & connecting it properly and complete all as specified and directed by Engr-in-charge.
Taking down and rewinding the ceiling fan motor of 1200/1400 mm sweep, with super enameled copper wire of appropriate guage in replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnishing , greasing/oiling of bush and the bearing, nut,bolt&washer etc and testing after reassembling and refixing at its original location complete all as specified and directed by engr-in-charge.
S&F PVC canopy of ceiling Fan of suitable size in repair complete al as directed by Engineer-in-Charge.
S & F of down rod making holes for fixing the nut bolt for 1200/1400 mm ceiling fan as per original patterncomplete all as approved by Engr-in-charge.
Supply and fixing FR PVC insulated unsheathed flexible wire copper conductor 1100 volt house wire grade confirm to IS 694/1990 0.75 sqmm twin core including making connection complete all as specified and as directed by Engr-In-Chage. Make :Plaza/Kalinga/Polycab/Finolex/Havells/
Spray painting with synthetic enamelled paint of approved colour (as approved GE) after preparation/Making of old surface suitable for painting of ceiling fan of any sweep/Make/Model complete all as specified and directed by Engr-In-Charge. Make : Berger/Asian/Nerolac
Disconnecting and taking down the complete Exhaust fan any size /make/sweep at any location for carrying out over hauling such as cleaning ,oiling,lubricating,greasing etc and refixing the exhaust fan back on the same location & connecting it properly and complete all as specified and directed by Engr-in-charge.
Taking down unserviceable motor and rewinding the Exhaust fan 300 MM singal phase 230 volt motor with super enameled copper wire of appropriate guage of any make including replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnishing , greasing/oiling of bush and the bearing, replacement of missing/worn out nut,bolt & washer split pin etc and testing after reassembling the same complete all as specified and directed by engr-in-charge
Supply and fixing Exhaust fan Louver for 300 mm in repair complete all as specified and directed by Engr-in- Charge
Supply & Fixing U-clamp complete with rubber real all as specified and directed by the Engr-in-Charge
R D Bansal
GS Engineers
KUMAR AND COMPANY
M/s badrinath Traders
SATYAM ENGINEERS
DHILLON CONSTRUCTION CO
M/s Bhagwati Enterprises
M/S MATLOOB AHMED
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .