Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹76.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹78.1 L+₹59,812 (0.77%)Rejected-Finance 131 SANGAM NAGAR OPP NATIONAL SCHOOL SANGHVI PUNE 411027 | PUNE | MAHARASHTRA | 411027 | L2 | Rejected-Finance Higher amount quoted | |
| 3 | L3₹83.7 L+₹6.2 L (8.02%)Rejected-Finance | L3 | Rejected-Finance Higher amount quoted | |
| 4 | L4₹97.3 L+₹19.9 L (25.6%)Rejected-Finance | L4 | Rejected-Finance Higher amount quoted |
Tender Value
₹86.1 L
EMD Value
₹1.5 L
Closing Date
1 Feb 2023, 6:00 pmClosed
CWE PUNE
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
85847REPAIR / MAINT CENTRAL AIR CONDITIONER, COOLING TOWERS AND REPAIR TO ELECTRIC CONTROL PANELS AT NEW CHSC AND OTHER CONNECTED AREA UNDER GE (SOUTH) PUNE.
2022_MES_563867_2
85847REPMAINTACATGESPUNE
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
GE South Pune
As per tender
9 documents required · 9 mandatory
₹1,000
GE South Pune
₹1.5 L
Yes
28 Mar 2023
11 Jan 2023
3 Feb 2023
11 Jan 2023
1 Feb 2023
18 Jan 2023
Amount
Preventive , Scheduled maintenance and attending breakdown in all three shifts of running of Centrifugal Water Cooled Water Chilling M/C of 500 TR with R - 134 A refrigerant, open / semihermatic / hermatically sealed centrifugal compressor, direct / gear driven by suitable KW Sq. Cage induction motor complete with variable speed drive, water-cooled shell & tube condenser, insulated shell and tube flooded chiller, flow switches at condenser & chiller outlet, refrigerant piping, Refrigerant and Oil (First Charge), flexible pipe connector at condenser & chiller inlet / outlet, integral lubrication system, Microprocessor based control panel, chiller / floor mounted VSD & accessories etc. all mounted on M.S. frame. suitable for 415 volts ± 10%, 50Hz ± 5 %, three phase A.C. supply. specifications & having interface card compatible with BMS system maintaining following parameters.
Condenser : CDW IN - 32.22º C. / CDW OUT - 36.39º C./ FLOW - 7560 LPM / Fouling Factor (MKS) - 0.0002 / Pressure Drop Max - 8.5 Meter
Chiller : CHW IN - 12.22º C. / CHW OUT - 6.67º C./ FLOW - 4536 LPM /Fouling Factor (MKS) - 0.0001/Pressure Drop Max - 7.5 Meter
IKW / TR (Maximum) - 0.68
Details of equipment installed: (a)500 TR centrifugal water cooled chillers=4 Nos.(Mcquay make) (b)Chilled Water Pumps (Primary)= 3 Nos. (c) Chilled Water Pumps (Secondary)=3 Nos. (d) Condenser Water centrifugal Pumpsets 55KW/75HP,7560LPM=4 Nos. (e) Primary chilled water centrifugal pump sets 25HP,4536LPM =04 nos (f) Secondary Chilled water centrifugal pump,TEFC 40 HP,4536 LPM=04 Nos (f) variable speed pumping system for secondary pumps(g)FRP induced draft Cooling Tower 550TR =04Nos(g) VFD systems for cooling tower10 HP=8 machines.(h) Hot water generator of 500KW =03 nos(j) HW monoblock pump set 7.5HP,522 LPM=04 Nos (k) double skin Floor Mounted AHU’s 2000 to 16000CFM = 70 Nos.(l) Ceiling suspended AHU 3000CFM=06 Nos (m) supervisory controllers for BMS,DDC,CHW,CDW,CT,HWG,AHU(g)AHU Blower variable speed drive (VFD)=10 Nos. (n) 200mm Air Separator=1 No. (o) inline fan300 to 2000 CFM= 46No. (p) HRV units =5 Nos. (q) Closed vessel expansion tank complete With all accessories=1No. (r)Jet diffusers=130 Nos. (s) Smoke Extraction Fan= 22 Nos. (t)Inline Fan & Propeller Fans=1 Nos. (u)All the Electrical Control Panel in AC Plant, Control Console Panel & AHU Room Panels (v)Associated work such as piping, valves and (w) Fan coil units 1 TR to 2.5TR=175 nos (x) Floor mounted air washer 25000 to 30000CFM=03 Nos (y)Pressure fans 10000 to 15000CFM=28 Nos(z)
Contractor shall get execute the comprehensive maintenance of high side of Central AC plant by deputing AHRI/ARI certified technician using material/spare parts from OEM/Authorised dealer and service/repair advise after the inspection by OEM at zero month, 5th month, 11th month of the starting of AMC. The Contractor shall not be reimbursed for inspection charges but has to share the inspection report with Engineer In-charge.
Contractor has to maintained all the equipments by due preventive maintenance and keep ready for operation by deputing suitable manpower on demand at one hour notice otherwise Compensation be recovered @ Rs. 10000 per day(for the area to be air conditioned)from the FB/RAR of the contractor for nonfunctioning of HVAC system, offcourse with no payment for comprehensive maintenance and operation on pro-rata basis for the day. Whereas recovery of shortage of workman shall be done @Rs. 2000/- per day for AC technician & Electrician each and Rs. 1300/- per day for helper for the day.
The agency has to do air balancing / water balancing as and when required and nothing extra shall be paid on this account.
The firm shall maintain history cards of each equipment maintained under their control. There shall be checklist for preventive & comprehensive maintenance schedule including de-scaling servicing, general cleanliness & checking etc. To be carried out weekly, quarterly & annually. The firm shall be providing all the necessary maintenance services and the same shall be recorded in the history cards of the equipment. Copy of this history card shall be submitted to Engineer-in-Charge for the record.
Contractor will ensure that 1xAC technician with minimum five years experience in repairing 500 TR capacity chiller plants,1x Electrician with minimum five years experience in repairing of VFD,ACB,LT panel and MCC Panels.2x Helpers with working knowledge in Ref &AC and Electric Supply
Preventive and Comprehensive maintenance of pre-fabricated Walk-In-Cooler with compressor, air-cooled condenser, coil, control panel & accessories as required to maintain 4 - 5 Degree Centigrade & of following capacity.
(a) 5 TR=06 Nos.
(b) 1 TR=04 Nos.
Disconnecting electrically and mechanically defective/burnt squirrel cage induction motor, shifting to civil workshop, opening for inspection, removing of unserviceable ball bearings, gaskets etc, cutting of old burnt winding, cleaning of slots, fixing of insulated material, winding with new super enemelled copper winding wire of suitable gauge, varnishing, re-assembling, transporting to site, re-fixing at existing location, connecting mechanically, electrical connections, testing to entire satisfaction of Engineer-in-charge all as directed at site for capacity 1 HP to 1.5 HP. Note: - Cost of spares will be measured and paid seperately under relevant items.
All as per Item No. 03 here-in-above but 3 HP capacity.
All as per Item No. 03 here-in-above but 5 HP capacity.
All as per Item No. 03 here-in-above but 7.5 HP capacity.
All as per Item No. 03 here-in-above but 10 HP capacity.
All as per Item No. 03 here-in-above but 12.5 HP capacity.
All as per Item No. 03 here-in-above but 15 HP capacity.
All as per Item No. 03 here-in-above but 20 HP capacity.
All as per Item No. 03 here-in-above but 30 HP capacity.
All as per Item No. 03 here-in-above but 40 HP capacity.
All as per Item No. 03 here-in-above but 60 HP capacity.
All as per Item No. 03 here-in-above but 75 HP capacity.
Disconnecting mechanically centrifugal pump, shifting to civil workshop, opening for inspection, removing of unserviceable parts like ball bearings, impellers, impeller nut, 'O' ring, eye ball, shaft, bearing housing, gland packing, gasket set etc & replacement of old unserviceable spares with new ones, re-assembling, shifting to site, re-fixing at existing location, connecting mechanically, testing to entire satisfaction of Engineer-in-charge all as directed at site of capacity 1 HP to 1.5 HP. Note: - (i) Cost of spares will be measured and paid seperately under relevant items.
All as per Item No. 15 here-in-above but 3 HP capacity.
All as per Item No. 15 here-in-above but 5 HP capacity.
All as per Item No. 15 here-in-above but 7.5 HP capacity.
All as per Item No. 15 here-in-above but 10 HP capacity.
All as per Item No. 15 here-in-above but 12.5 HP capacity.
All as per Item No. 15 here-in-above but 15 HP capacity.
All as per Item No. 15 here-in-above but 20 HP capacity.
All as per Item No. 15 here-in-above but 25 HP capacity.
All as per Item No. 15 here-in-above but 30 HP capacity.
All as per Item No. 15 here-in-above but 40 HP capacity.
All as per Item No. 15 here-in-above but 60 HP capacity.
All as per Item No. 15 here-in-above but 75 HP capacity.
Supply only ball bearing model 6202 Make-SKF/TATA/NBC/HMT. (Pump and motor 1 HP to 1.5 HP).
All as per Item No. 28 here-in-above but 6203 (Pump and motor 3 HP).
All as per Item No. 28 here-in-above but 6204 (Pump and motor 5 HP).
All as per Item No. 28 here-in-above but 6205 (Motor 7.5 HP).
All as per Item No. 28 here-in-above but 6306 (Motor 10 HP).
All as per Item No. 28 here-in-above but 6205 (Pump 10 HP).
All as per Item No. 28 here-in-above but 6306 (Motor 12.5 HP).
All as per Item No. 28 here-in-above but 6307 (Motor 15/20 HP).
All as per Item No. 28 here-in-above but 6311 (Motor 30 HP).
All as per Item No. 28 here-in-above but 6206/6207 (Pump 30 HP).
All as per Item No. 28 here-in-above but 6312 (Motor 40 HP).
All as per Item No. 28 here-in-above but 6308/6309 (Pump 40 HP).
All as per Item No. 28 here-in-above but 6311/ 6312(Pump 60 HP).
All as per Item No. 28 here-in-above but 6312/6313 (Pump 75 HP).
Re-metaling/machining work for shaft of centrifugal pump set of capacity 1/1.5 HP, grinding, polishing and matching to reqiured size/shape all as directed by the Engr-in-Charge.
All as per Item No. 42 here-in-above but for pump set of capacity 2 HP to 3 HP.
All as per Item No. 42 here-in-above but for pump set of capacity 5 HP.
All as per Item No. 42 here-in-above but for pump set of capacity 7.5 HP.
All as per Item No. 42 here-in-above but for pump set of capacity 10 HP to 12.5 HP.
All as per Item No. 42 here-in-above but for pump set of capacity 15 HP.
All as per Item No. 42 here-in-above but for pump set of capacity 20 HP.
All as per Item No. 42 here-in-above but for pump set of capacity 25 HP.
All as per Item No. 42 here-in-above but for pump set of capacity 30 HP.
All as per Item No. 42 here-in-above but for pump set of capacity 40 HP.
All as per Item No. 42 here-in-above but for pump set of capacity 60 HP.
All as per Item No. 42 here-in-above but for pump set of capacity 75 HP.
Supply only gun metal impeller suitable for 1/1.5 HP capacity centrifugal pump set as per existing model and make for Kirloskar make pump set.
All as per Item No. 54 here-in-above but for pump set of capacity 3 HP.
All as per Item No. 54 here-in-above but for pump set of capacity 5 HP to 7.5 HP.
All as per Item No. 54 here-in-above but for pump set of capacity 10 HP to 15 HP.
All as per Item No. 54 here-in-above but for pump set of capacity 20 HP to 30 HP.
All as per Item No. 54 here-in-above but for pump set of capacity 40 HP.
All as per Item No. 54 here-in-above but for pump set of capacity 60 HP.
All as per Item No. 54 here-in-above but for pump set of capacity 75 HP.
Supply only V belt or link belting for size A-28, Make : Fenner or equivalent as approved by GE.
Supply onlyV belt ,or link belting for sizeB-29 Make : Fenner or equivalent as approved by GE.
Supply only V belt , or link belting for size A-32 Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for size B-32, Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for sizeB-36, Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for size B-38,Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for size B-39, Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for sizeB-49, Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for size A-41, Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for size B-52, Make : Fenner or equivalent as approved by GE.
Supply onlyV belt or link belting for size B-53,Make : Fenner or equivalent as approved by GE.
Supply onlyV belt or link belting for size B-60,Make : Fenner or equivalent as approved by GE.
Supply onlyV belt or link belting for size A-60,Make : Fenner or equivalent as approved by GE.
Supply only V beltor link belting for size A-61, Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for sizeA-63, Make : Fenner or equivalent as approved by GE.
Supply only V belt link belting for reqd size B-72,or Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size B-73,Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size B-76,Make : Fenner or equivalent as approved by GE.
Supply only repair V beltor link belting for reqd size B-78,Make : Fenner or equivalent as approved by GE.
Supply onlyV belt or link belting for reqd size B-82, Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size C-82,Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size B-88,Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size B-92, Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size B-102,Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size B-105,Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size B-108,Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size B-110,Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size C-144, Make : Fenner or equivalent as approved by GE.
Supply onlyV belt or link belting for reqd size A-26, Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size A-30,Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size A-36,Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size A-37, Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size A-43, Make : Fenner or equivalent as approved by GE.
Supply only V beltor link belting for reqd size A-44, Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size A-46, Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size A-48,Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size A-51,Make : Fenner or equivalent as approved by GE.
Supply onlyV belt or link belting for reqd size A-49,Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size A-63,Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size A-64,Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size A-21,Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size B-33, Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size B-58,Make : Fenner or equivalent as approved by GE.
Supply only V belt or link belting for reqd size B-28,Make : Fenner or equivalent as approved by GE.
Supply only flexible tyre coupling of size TC-015 including , nuts, bolts and washers suitable for centrifugal motor pump set 30/40HP capacity complete match with existing one.
All as per Item No. 106 here-in-above but of size TC-014.
All as per Item No. 106 here-in-above but of size TC-013.
All as per Item No. 106 here-in-above but of size TC-012.
All as per Item No. 106 here-in-above but of size TC-011 suitable for pump set of capacity 10 HP.
Supply of PVC fills suitable for cooling tower 550 TR (1995840 Kcal/hr) of existing size and thickness not less than 0.2mm all as specified and directed.
Supply electronic Timer for star delta Timer 3Sec to 120Sec,,240VAC model, 2ASDTO of Make – L & T or equivalent as approved by GE complete all as directed.
Descaling AHU’s cooling coil of capacities 2000 to 5000CFM, by opening of cooling coil, circulating acid / suitable chemical for removing all foreign material gathered in the coil, cleaning of all filters, re-fixing and testing complete all as specified and directed by Engineer-in-Charge.
All as per Item No.113 here-in-above but 5500 to 10000 CFM.
All as per Item No.113 here-in-above but 10000 to 15000 CFM.
Supply only prefilter of non woven synthetic media of 10 micron particle size with an efficiency of 90% all as specified and directed.
Supply only Fine filter of non woven synthetic media of 5 micron particle size with an efficiency of 90% all as specified and directed
Supply only PU foam of 23mm thick and 36 Kg/cum all as specified and directed
Supply only PU foam of 48mm thick and 36 Kg/cum all as specified and directed
Supply only Pressure Independant Balancing Cum Two Way Control Valve in a single body equipped with electronic modulating actuator working on 2-10 V DC, 4- 20 mA electric signal. The minimum close off Pressure of actuator must be 1.5 times shut off head of pump as per specifications of following sizes:
20 mm Dia, Maximum 6 GPM
25 mm Dia, Maximum 8 GPM
32 mm Dia, Maximum 17 GPM
40 mm Dia, Maximum 26 GPM
50 mm Dia, Maximum 50 GPM
65 mm Dia, Maximum 72 GPM
80 mm Dia, Maximum 132 GPM
Supply only digital display type thermostat & humidistat for various OT Air Handling Units including temperature and humidity sensor. The thermostat shall have provision of setting of space temperature and space RH as per requirement. Unit controller shall be installed in OT Room.
All as per Item No.121 here-in-above but for proportional cooling/heating type digital display type thermostat at air handler.
All as per Item No.121 here-in-above but Snap Acting digital display type thermostat at air handler.
M&L for automatic control for Fan Coil Units consisting of pressure independant balancing cum two way control valve (already & digital thermostat, which will have provision of setting of room temperature, setting of fan speed (High, Medium, Low).
M&L for repair of Inline fans with motor incl rewinding with superenamelled copper wire of existing gauge incl appropriate class of insulation ,incl replacement of bush , ball bearing and inbuilt speed controller complete in all respect & of following capacities.
a) 300 CFM (8mm static pressure, single phase)
b) 500 CFM (10mm static pressure, single phase)
c) 600 CFM (10mm static pressure, single phase)
d) 700 CFM (10mm static pressure, single phase)
e) 800 CFM (12mm static pressure, single phase)
f) 900 CFM (12mm static pressure, single phase)
h) 1000 CFM (15mm static pressure, single phase)
i) 1200 CFM (15mm static pressure, single phase)
j) 1500 CFM (15mm static pressure, single phase)
k) 1800 CFM (15mm static pressure, three phase)
l) 2000 CFM (15mm static pressure, single phase)
Supply only Laminar air flow pattern perforated plenum made of 16 G aluminium sheet, Aluminium VCD, DOP tested Hepa filters of efficiency 99.97 % down to 0.3 micron particle size & suitable for operation theatre with all accessories as required & to suit site condition of size 2.4 x 2.7 m²
Supply only bare chilled / condenser / Hot water piping of M.S 'Heavy' Class complete with fittings like elbows, tees, reducers, bends, MS flanges, supports, welding, painting etc. but excluding valves as required conforming to IS:1239 / 3589 & technical specification. All outdoor condenser water piping shall be treated with Zinc Cromate Primer plus two coats of Epoxy Paints.
a) 25 mm dia pipe
b) 32 mm dia pipe
c) 40 mm dia pipe
d) 50 mm dia pipe
e) 65 mm dia pipe
f) 80 mm dia pipe
g) 100 mm dia pipe
h) 125 mm dia pipe
i) 150 mm dia pipe
j) 200 mm dia pipe
k) 250 mm dia pipe
l) 300 mm dia pipe
m) 400 mm dia pipe
m) 450 mm dia pipe
Supply only motorised on / off butterfly valves with modulating motor in return chilled & condenser water line of each chiller, condenser & cooling tower operated through BMS & of following sizes:
a) 250 mm dia (For Chillers)
b) 400 mm dia (For Condenser & Cooling Towers)
c) 450 mm dia (For Condenser & Cooling Towers)
Supply only automatic balancing valves in return chilled and condenser water line of each chiller, condenser and cooling tower as per tender specification & of following sizes:
a) 250 mm dia (For Chillers)
b) 400 mm dia (For Condenser & Cooling Towers)
b) 450 mm dia (For Condenser & Cooling Towers)
Supply only of following sizes butter fly valves in chilled / condenser water line as per specification given in the tender.
a) 50 mm dia
b) 65 mm dia
c) 80 mm dia
d) 100 mm dia
e) 125 mm dia
f) 150 mm dia
g) 200 mm dia
h) 250 mm dia
i) 300 mm dia
j) 350 mm dia
Supply only of following sizes globe valves in chilled / condenser water line as per specification given in the tender.
a) 25 mm dia
b) 32 mm dia
c) 40 mm dia
Supply only of following sizes Check valves in chilled / condenser water line as per specification given in the tender.
a) 250 mm dia
b) 100 mm dia
Supply onlyof following sizes Y strainers in chilled / condenser water line as per specification given in the tender.
a) 25 mm dia
b) 32 mm dia
c) 40 mm dia
d) 50 mm dia
e) 65 mm dia
f) 80 mm dia
g) 200 mm dia
h) 250 mm dia
Supply only alcohal fitted 'V' form thermometer of approved make . (For Floor Mounted AHU, Chiller & Condenser)
Supply only pressure guage of approved make of dia 150 mm (For Floor Mounted AHU, Chiller, Condenser & All Pumps)
Supply only condensate drain water piping of GI 'Medium' class complete with fittings like elbows, tees, reducers, bends, MS flanges, supports, welding, painting etc. as required , specified and directed and of following sizes.
a) 25 mm dia pipe
b) 32 mm dia pipe
c) 40 mm dia pipe
d) 50 mm dia pipe
e) 65 mm dia pipe
f) 80 mm dia pipe
g) 100 mm dia pipe
Supply only chilled water piping with Closed Cell Elastomeric Nitrile Rubber of specified thickness and suitable for indoor application. Outdoor pipe from AC Plant shall run in pucca concrete trench & shall be insulated as per indoor application all as specified and directed.
a) 25 mm dia
b) 32 mm dia
c) 40 mm dia
d) 50 mm dia
e) 65 mm dia
f) 80 mm dia
g) 100 mm dia
h) 125 mm dia
i) 150 mm dia
j) 200 mm dia
k) 250 mm dia
kl) 350 mm dia
m) 400 mm dia
n) 300 mm dia
Supply only Insulation on valves with Closed Cell Elastomeric Nitrile Rubber of specified thickness in the tender specification & suitable for indoor application. Motorised Butterfly Valves
a) 250 mm dia (For Chillers)
b) 100 mm dia (For Hot Water Generator)
Butterfly Valves
a) 50 mm dia
b) 65 mm dia
c) 80 mm dia
d) 100 mm dia
e) 125 mm dia
f) 150 mm dia
g) 200 mm dia
h) 250 mm dia
i) 300 mm dia
j) 350 mm dia
k) 400 mm dia
Globe Valves.
a) 25 mm dia
b) 32 mm dia
c) 40 mm dia
Check Valves
a) 250 mm dia
b) 100 mm dia
Automatic Balancing Valves
a) 250 mm dia (For Chillers)
b) 100 mm dia (For Hot Water Generator)
Y-strainer
a) 25 mm dia
b) 32 mm dia
c) 40 mm dia
d) 50 mm dia
e) 65 mm dia
f) 80 mm dia
g) 100 mm dia
h) 250 mm dia
M&L for replacement of auto air vent valve of following sizes:-
a) 10 mm dia auto air vent valve
b) 19 mm dia auto air vent valve
c) 25 mm dia auto air vent valve
M&L for replacement of acoustic insulation on four walls & ceiling of AHU Rooms with 50 mm thick fibre glass of density 32 Kg/m³ fixed in square frame box of size 610 x 610 mm, frame made of 24 G GI sheet of size (25 - 50 - 50 - 50 - 25 mm) coverd with fibre glass tissue paper and finally finished with 0.5mm thick perforated aluminium sheet & conforming specification. All vertical & horizontal joints to be sealed with 25 mm wide 1.0 mm thick aluminium beading.
M&L for replacement of multiblade box type Galvanized Sheet Steel construction damper for ducts to be provided with suitable links and quadrants for control of volume of air.
M&L for replacement of multiblade box type Aluminium Sheet construction damper for ducts to be provided with suitable links and quadrants for control of volume of air. (For OT Only)
M&L for replacement of insulated Flexible ducting made of double lamination of Metalized Polyster Film permanentaly bounded to a coated spring steel wire helix & resistant construction to tear & puncture branch & collar wherever suitable & of following sizes:
a) 200 MM Dia.
b) 250 MM Dia.
c) 300 MM Dia.
M&L for replacement of Aluminium sheet metal ducting duly polysulphide sealed complete with Spliter Damper, vanes etc. as required for OT and as per ISI specifications and as per approved shop drawings.
M&L for replacement of acoustic lining of duct with fibre glass rigid board of density 48 Kg/m³ sealed in fibre glass tissue paper and covered with 0.5 mm thick perforated aluminium sheet and conforming to specification given in the tender.
a) 12 mm thick fibre glass rigid board.
b) 25 mm thick fibre glass rigid board.
M&L for replacement of external thermal insulation on ducts with Cross Linked Closed Cell Polyethylene FR-XPE insulation, tape & adhesive (pidilite SR -998) as required of following thickness.
a) 6 mm thick
b) 9 mm thick
c) 13 mm thick
M&L for replacement of Duct / Wall mounted GI Fire Dampers actuated with the help of 24 V electric actuator and as per specifications excluding actuator.
M&L for replacement of Motorised Spring Return Actuator for devices upto 0.8 sq. metre with with control panel & temperature sensor.
M&L for replacement of Immersion Temperature sensor for Chilled water system all as specified and directed.
M&L for replacement of Ultrasonic Type Water flow meter (5,400 USGPM For Header)all as specified and directed.
M&L for replacement of Ultrasonic Type Water flow meter (1800 USGPM For Individual Chillers)all as specified and directed.
M&L for replacement of Ambient air temperature and humidity sensor all as specified and directed.
M&L for replacement of Current relay for pumps all as specified and directed.
M&L for replacement of Differential pressure switch for various vent. fans all as specified and directed.
M&L for replacement of Differential pressure switch for AHU blower status all as specified and directed.
M&L for replacement of Differential pressure switch for AHU pre, fine & hepa filter status all as specified and directed.
M&L for replacement of Temperature sensor for return temperature monitoring all as specified and directed.
M&L for replacement of Digital electronic multimeter all as specified and directed.
M&L for replacement of Pressure Transducer all as specified and directed.
M&L for replacement of ICU pressure monitor system with the following specifications: - High precision ICU pressure monitor system fitted at entrance of the ICU to view positive pressure inside the ICU. Positive and negative pressure cubical shall be fitted with separate ICU pressure monitoring system. Make/Manufacturer :- Western India Electromedical systems pvt. ltd. model No PS-066 or any other equivalent model in Hospedia medicare/Becon Meades/Penlon/CMS.
Supply, Install, testing and commisiong of Hepa filter plenum with Hepa Filter (99.97% particulate efficiency) (Make :- AAF/AIRTECK) 2' x 1' for each bed. HEPA Plenum shall made up of high quality S.S. 304 diffuser grill to secure the unidirectional air flow according to EN ISO 14644. MOC of Plenum & diffuser grill - SS 304, matt polish, sheet thickness 1.2mm, make Jindal or TATA. Make/Manufacturer :- Western India Electromedical systems pvt. ltd./ tanvi enterprises /Alvo/Voks air.
Supply, installation & testing of , Aluminium VCD, DOP tested Hepa filters of efficiency 99.97 % down to 0.3 micron particle size & suitable for operation theatre with all accessories as required & to suit site condition of size 2.4 x 2.7 m²
M&L for replacement of Single Function meter,Three phase Voltmeter accuracy class 1.,0-520VAC,flush mounting 96x96mm Model :WL1310, Make L&T or equivalent as approved by GE.
M&L for replacement for Proportional cooling / heating type digital display type thermostat at air-handler.
Snap Acting digital display type Humidistat at air-handler.
Servicing and overhauling of Air circuit Breaker Model UW1-20 N ,800-2000A,Four pole incl cleaning of Fixed and moving contacts,shut release coil and operating mechanism. Spares reqd for replacement will be measured and paid separately all as specified and directed.
Spares for Air circuit breaker Model: UW1-20N,2000A, Make L&T or equivalent as approved by GE.
Supply only draw out ACB's terminal adapters frame 1,2000A N (vertical/Horizontal) all as specified and directed.
Supply only operation counter all as specified and directed.
Supply only door interlock all as specified and directed.
Supply only Electrical Position indication(EPI) all as specified and directed.
Supply only Microswitch for Ready to close indication(TRC) all as specified and directed.
Supply only micro switch for Common fault Indication (CFI) all as specified and directed.
Supply only micro switch for Shunt release all as specified and directed.
Supply only micro switch for Under Voltage release all as specified and directed.
Supply only micro switch for Common fault Indication all as specified and directed.
Supply only micro switch for Spring Charging Indication all as specified and directed.
Supply only Electrical charging device (ECD) 110VAC/110-125V AC all as specified and directed.
Supply only Closing release (CR) 110VAC/110-125V AC all as specified and directed.
Supply only Shunt Release (SR)110VAC/110-125V AC all as specified and directed.
Supply only Under Voltage Release (UVR) with time delay (0-1-3-5)110VAC/110-125V AC all as specified and directed.
M&L for butt welded joint for joining circumferential pipe to itself, fittings, flanges, Valves, and other equipment all as specified and directed.
M&L for complete robotic cleaning of ducts by using HEPA filtered vaccum unit to create negative pressure in the duct system from AHU to Plenum and return duct to AHU room, by placing the same outside the occupied space by using variety of tools to agitate and loosen the dust, which shall be then drawn into the vaccum unit and contained therein. the cleaning should be done by using robotic tool ,monitored & operated remotely video camera for cleaning the hard to reach areas, which are out of reach for most duct cleaning equipments. Access cutting can be made, if required and shall later be refitted with screw and sealant. All floors and furnishing where the work will be carried on shall be covered and complete care shall be taken to avoid minimum amount of cross- contamination. upon completition of work the system shall be sanitized by fogging the ducts to ensure all mold and bacteria spores and foul smell is eradicated the entire process shall be caried out with Air compressor with bib, pneumatic air whips and power jobs, Rotary brush Drum vaccum wit pipe. Negative machine HEPA and 10" hose pipe and Robo camera with control unit. All clening agents/chemicals used shall be inaccordance with the regulation and shall be certified for use in the respective system .During the inspection process collect particulate samples from the duct interior to provide with a complete laboratory analysis of the particulate content to identify hazards such as asbestos. Microbial samples are also taken to evaluate the duct surface for bacteria and mould growth as directed and specified by Engr-in Charge. : PVC sheets or protective covers for installed medical equipment and accessories reqd for ingress Protection of medical equipments will be arranged by the contractor and its cost is included in unit rate
S&F in replacement MCCB FP,125A Thermal magnetic release 100-125A,breaking capacity 25KAModel DN1-250C Make L&T or equivalent as approved by GE.
S&F in replacement MCCB FP,400A,Thermal magnetic release 320-400A,breaking capacity 25KA Model DN3B-400D Make L&T or equivalent as approved by GE.
S&F in replacement MCCB TP,63A ,Thermal magnetic release 50-63A,breaking capacity 25KA,Model DN0-100C Make L&T or equivalent as approved by GE.
S&F in replacement MCCB TP,40A Thermal magnetic release 32-40A,breaking capacity 25KA Model DN0-100DMake L&T or equivalent as approved by GE.
M&L for replacement of Therml overload relay with current range 8.5A to 12.5A Type RTO-1 suitable for MO contactor Make L&T or equivalent as approved by GE.
M&L for replacement of Therml overload relay with current range 17A to 25.5A Type RTO-1 suitable for MO contactor Make L&T or equivalent as approved by GE.
M&L for replacement of Therml overload relay with current range 47A to 62A with auxillary contacts 2NO+ 2NC Type RTO-3 suitable for MO contactor Make L&T or equivalent as approved by GE.
M&L for replacement of power contactor MO25 CONFIRMING TO IS/IEC 60947-4-1 Make-L&T or equivalent as approved by GE.
M&L for replacement of power contactor MO140 with auxillry contacts 2NO+ 2NC Conforming to IS/IEC 60947-4-1 Make-L&T or equivalent as approved by GE.
M&L for replacement of single phase preventor Model VSP2 Maake Minilec or equivalent as approved by GE.
M&L for replacement of Push button as per sample Make-L&T or equivalent as approved by GE.
M&L for replacement of indicator lamps LED type with holder suitable for panel control functions Make-L&T or equivalent as approved by GE.
M&L for replacement of MCB SP 2A,C-curve,15KA mounting on DIN channel all as specified and directed. Make-L&T or equivalent as approved by GE.
M&L for front mounting add-on aux contact block 2NO + 2NC for MNX contactors all as specified and directed. Make-L&T or equivalent as approved by GE.
M&L for front mounting add-on aux contact block 2NO + 2NC for MO contactors all as specified and directed. Make-L&T or equivalent as approved by GE.
M&L for non metalic PVC conduit 20 mm external dia exclusive of boxes (junction/Terminal) but inclusive of all Tees,Bends,Elbows,reducers,bell mouth tube ends and fixing accessories such as couplers,lock nuts,saddles,pipe hooks etc all as specified and directed.
M&L for non metalic PVC conduit 25 mm external dia exclusive of boxes (junction/Terminal) but inclusive of all Tees,Bends,Elbows,reducers,bell mouth tube ends and fixing accessories such as couplers,lock nuts,saddles,pipe hooks etc all as specified and directed.
M&L for PVC junction boxes suitable for 20mm conduit (1 to 4 Way) all as specified and directed.
M&L for PVC junction boxes suitable for 25mm conduit (1 to 4 Way) all as specified and directed.
Supply only for replacement of power contactor MO45 CONFIRMING TO IS/IEC 60947-4-1 all as specified and directed Make-L&T or equivalent as approved by GE.
Supply only for replacement of power contactor MNX25 confirming to IS/IEC 60947-4-1 Make-L&T or equivalent as approved by GE.
Supply only MCBFP 63A,C Curve, 415V all as specified and directed Model BB40630C make : L&T or equivalent as approved by GE.
Supply only MCBFP 40A,C Curve, 415V all as specified and directed Model BB40400C make : L&T or equivalent as approved by GE.
Supply only MCBSP 6A,C Curve, 230V all as specified and directed Model BB10060C make : L&T or equivalent as approved by GE.
Supply only Variable frequency drive unit complete capacity 7.5KW/10HP, all as specified and directed Model No : 134F2929 Make Danfoss or equivalent as approved by GE.
Supply only power supply unit input 100-240V,1.4A output DC 12V,4.2A all as specified and directed Model: S8JX-G05012CD Make OMRON or equivalent as approved by GE.
Supply Only Isolation Transformer 100VA,50-60Hz all as specified and directed make McQuay International or equivalent as approved by GE.
Supply Only Isolation Transformer 15VA,50-60Hz all as specified and directed make McQuay International or equivalent as approved by GE.
Supply only motor winding sensor (GDB) 24VAC,50/60Hz,Cut off at 4000Ohm, Cut in 700Ohm as per sample all as specified and directed.
Supply only capacitor 60micro farad,440VAC,50Hz all as specified and directed.
Supply only noise Filter ,30A,50/60hZ,250v ,55 degree,25/100/21 Model SUPF-EX30-ER-6 all as specified and directed.
Supply only PLC based unit compressor Controller, input24VAC,50/60Hz/24VDC max power 40VA, all as specified and directed Make DAIKIN or equivalent as approved by GE.
Supply only BAC net Router Model PXG3.L,S55842-Z105-A100 all as specified and directed Make Siemens or equivalent as approved by GE.
Supply only data/Communication Cable 2 core x 1.0Sqmm tinned copper shield unarmoured Cable ,Fusion polymer ,1100V grade all as specified and directed.
Supply only Dinkle assembly DK6N10 gang box Connector for 14 way,8-20AWG,50A,1100V.
Supply only cat 6 UTP PVC FR (with separator) communication Cable 6 core as per sample.
Leo Enterprises
Takshashila electricals
somnath engineering corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .