Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 LAccepted-AOC CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | ₹17.8 L Quoted ₹18.7 L | L1 | Accepted-AOC ok |
| 2 | L2₹18.8 L+₹16,660 (0.89%)Rejected-Finance | ₹18.8 L+₹16,660 (0.89%) | L2 | Rejected-Finance Other than lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
29 Dec 2021, 6:00 pmClosed
GE (AF) UTARLAI
GE (AF) UTARLAI, PB NO 11, BARMER (RAJ) 344001
REPAIR TO CELLING FAN, WALL FAN, EXHAUST FAN, GEYSERS, SOLAR WATER HEATING SYSTEM AT AF STN UTARLAI
2021_MES_491704_1
8246/03/E8 dt 01 Dec 2021
Open Tender
Civil Works
Item Rate
180 days
GE (AF) UTARLAI
As Per NIT
7 documents required · 7 mandatory
₹500
Yes
GE (AF) UTARLAI
₹40,000
Yes
4 Feb 2022
1 Dec 2021
5 Jan 2022
1 Dec 2021
29 Dec 2021
15 Dec 2021
Amount
Taking down ceiling fan of any make & sweep by disconnecting clips,lock nuts etc. from existing position of any height. (Note: Repair & maintenance shall be paid seperately under relevant items.)
Hanging only ceiling fan 1200mm/1400mm sweep and connecting up after repair & maintenance.
M&L for painting of ceiling fan, exhaust fan, wall circulator fans complete, in situ/lying in store with synthetic enamel paint (white colour) by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified.
Dismantling all components of ceiling fan 1200/1400mm sweep, cutting and removing burnt out copper winding from the rotor assy and rewinding with super enamelled copper winding wire of suitable guage and turns with necessary insulation materials, varnishing, reassembling, greasing to bearings, replacing bushes, replacement of capacitor and complete testing all as specified. Note :- (a) The spares like ball bearing, capacitor required for repair the fan will be measured and paid seperetely under respective item. (b) Expendable stores like cotton waste/cleaning materials, grease, lubricants, machine screws, safety split pin, bolt/nuts and transportation to and from site to work place are deemed to be included in rate quoted.
S&F in repair bearing suitable for ceiling fan 1200mm/1400mm sweep ISI marked.
S&F in repairs fan down rod of size 2' (60 Cm) suitable for ceiling fan 1200/1400 mm sweep complete all as specified.
S&F in repairs of rubber shackle and split pin with galvanised clamp complete with nuts, bults washer, complete all as directed by Engr-in-Charge.
S&F in repairs 2 core PVC insulated PVC sheathed flexible copper wire multistranded of size 40/0.0076mm guage from ceiling rose to fan connector complete all as specified.
S&F in replacement canopy made of plastic complete with nut bolt for fixing in position suitable for ceiling fan 1200mm/1400mm sweep
S&F in repairs of PVC top and bottom cover suitable for ceiling fan complete including nut and bolts all as directed by Engr-in-Charge.
S&F in repairs of spindle for ceiling fan of any type and any make complete all as directed by Engr-in-Charge.
S&F in repairs of stator for ceiling fan of any type and any make complete all as directed by Engr-in-Charge.
S&F in repairs of rotor for ceiling fan of any type and any make including accessories complete all as directed by Engr-in-Charge.
S&F in repairs of made of aluminium blade for ceiling fan of any type and any make (size of blade as existing fans) complete all as directed by Engr-in-Charge.
S&F in repair of capacitor 230 volts, 50 HZ, 2.5 mfd ISI marked complete all as directed.
Taking down exhaust fan of any make & size from existing position of any height for repair, maintenance and refixing the same after neccesary repair complete all as directed. Notes (i) The defective parts to be replaced and shall be measured and paid separately under relevant item of Sch . (ii) Cost of minor items i.e. Screws, nut & bolts etc shall be deemed to be included in the above item.
S&F in repair ball bearing (ISI marked) for exhaust fan of 450mm sweep capacities.
S&F in repair ball bearing (ISI marked) for exhaust fan of 300/380mm sweep capacities.
M&L for removing old burnt winding of exhaust fan 450mm sweep motor and rewinding the same with superior quality super enamelled copper wire of suitable size including insulation ,drying after varnishing complete all as directed and specified by Engr-in- Charge. Note:- (i) Cost of dismantling all components of exhaust fan, greasing, re-assembling and complete teshting shall be included in the quoted rate.
M&L for removing old burnt winding of exhaust fan 300/380mm sweep motor and rewinding the same with superior quality super enamelled copper wire of suitable size including insulation ,drying after varnishing complete all as directed and specified by Engr-in- Charge. Note:- (i) Cost of dismantling all components of exhaust fan, greasing, re-assembling and complete teshting shall be included in the quoted rate.
S&F in repairs of capacitor 3.15 mfd ISI marked complete all as directed
S&F in repairs of capacitor 4 mfd ISI marked complete all as directed
Taking down wall fan/ air circulator of any make & size from existing position of any height for repair, maintenance and refixing the same after neccesary repair complete all as directed. Notes (i) The defective parts to be replaced and shall be measured and paid separately under relevant item of Sch . (ii) Cost of minor items i.e. Screws, nut & bolts, mounting bolt & nuts etc shall be deemed to be included in the above item.
S&F in repair ball bearing (ISI marked) for wall fan of 400/450mm sweep capacities.
S&F in repair ball bearing (ISI marked) for wall fan of 600mm sweep capacities.
S&F in repair metal bush for wall fan of any cap/ any size sweep complete.
M&L for removing old burnt winding of wall fan/ air circulator 400/450mm sweep motor and rewinding the same with superior quality super enamelled copper wire of suitable size including insulation ,drying after varnishing complete all as directed and specified by Engr-in- Charge. Note:- (i) Cost of dismantling all components of exhaust fan, greasing, re-assembling and complete teshting shall be included in the quoted rate.
M&L for removing old burnt winding of wall fan/air circulator 600mm sweep motor and rewinding the same with superior quality super enamelled copper wire of suitable size including insulation ,drying after varnishing complete all as directed and specified by Engr-in- Charge. Note:- (i) Cost of dismantling all components of exhaust fan, greasing, re-assembling and complete teshting shall be included in the quoted rate.
S&F in repairs of capacitor 6 mfd ISI marked complete all as directed
Disconnecting of electric connection and dismantling complete solar water heating system FPC/ETC type of capacity 500 ltrs installed at single/double/triple storey building including hot & cold water pipes and hot water tank complete and refixing after servicing/repairing the system fixing back in position and testing complete all as specified and directed by Engineer-in-charge. Note : Rates quoted by the contractor shall deemed to be included for :- (a) Replace the worn out nuts bolts, washers, union, sockets, flanges and screws etc. (b) Descaling/ desludging, cleaning and washing of the solar FPC panel/ ETC pipes, hot water pipes, copper tubes, hot and cold water tanks by using appropriate chemicals and re-assembling the panel.
All as per items No. 30 here in before but of capacity 300 ltrs per day complete all as specified and directed by Engineer-in-charge.
All as per items No. 30 here in before but of capacity 200 ltrs per day complete all as specified and directed by Engineer-in-charge.
All as per items No. 30 here in before but of capacity 100 ltrs per day complete all as specified and directed by Engineer-in-charge.
S&F in repairs gun metal float valve assembly of size 15mm for solar water heater system all as directed by Engr-in-Charge.
S&F in repairs make up tank capacity 10 Ltr made out of stainless steel all as per existing sample & shape, including connection nipple for incoming and delivery as per existing complete for solar water heater all as specified and directed by Engr-in-Charge.
S & F in repairs of heating element suitable for solar water heating system of capacity 2 KW ISI marked as per existing shape all as directed by Engr-in-Charge.
S & F in repairs of heating element suitable for solar water heating system of capacity 3 KW ISI marked as per existing shape all as directed by Engr-in-Charge.
S & F in repairs of thermostat of capacity 0 to 80 degree suitable for upto 3 KW heating element of capacity all as directed by Engr-in-Charge.
Supply and fix as in replacement, solar panel toughened glass having thickness 3.2 mm all as per the existing model of system complete gasket made out of fine rubber to make system air tight, dust and water proof all as specified and directed by Engineer-in-charge.
S&F in repairs hot water storage tank of food grade stainless steel 100 ltr capacity with heat exchanger having thermic fluid / Anti - freeze solution complete suitable ETC (Evacuated Tube Collector) solar water heating system including opening the outer body removing the glass wool, fixing the tank and flling the glass wool as before, re-installing the outer body, connecting the inlet and outlet connection, air vent, replacing the inlet/ outlet nipple complete all as specified and directed by Engineer-in-charge.
S&F in repair hot water storage tank of food grade stainless steel 200 ltr capacity with heat exchanger having thermic fluid / Anti - freeze solution complete suitable FPC (Flat Plate Collector) solar water heating system including opening the outer body removing the glass wool, fixing the tank and flling the glass wool as before, re-installing the outer body, connecting the inlet and outlet connection, air vent, replacing the inlet/ outlet nipple complete all as specified and directed by Engineer-in-charge.
S&F in repair hot water storage tank of food grade stainless steel 500 ltr capacity with heat exchanger having thermic fluid / Anti - freeze solution complete suitable FPC (Flat Plate Collector) solar water heating system including opening the outer body removing the glass wool, fixing the tank and flling the glass wool as before, re-installing the outer body, connecting the inlet and outlet connection, air vent, replacing the inlet/ outlet nipple complete all as specified and directed by Engineer-in-charge.
Supply and fix as in replacement, solar evacuated glass tube including water seal gasket (top and bottom) suitable for 100/200/300 Ltrs Solar water heater complete all as per existing size and shape as specified and directed by Engineer-in-charge.
S&F in repairs of rotational moulded polyethylene water storage tank 500 Ltrs capacity (Cylindrical vertical with closed top) hoisted and fixed in position including fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line including dismantling old PVC storage tank, all as specified. Note:- PVC tank shall be ISI marked & having two layers.
M & L as in repairs submain wiring with two single core cables PVC FRLS insulated unsheathed 2.5 Sqmm stranded copper conductor drawn in existing conduit with and including PVC FRLS insulated 2.5 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge. Note : 2 runs of 2.5 sqmm PVC insulated unsheathed copper conductor and 1 run 2.5 sqmm PVC insulated unsheathed copper conductor shall be measured as single run.
M & L as in repairs submain wiring with two single core cables PVC FRLS insulated unsheathed 4.0 Sqmm stranded copper conductor drawn in existing conduit with and including PVC FRLS insulated 4.0 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge. Note : 2 runs of 4.0 sqmm PVC insulated unsheathed copper conductor and 1 run 4.0 sqmm PVC insulated unsheathed copper conductor shall be measured as single run.
M & L as in repairs submain wiring with two single core cables PVC FRLS insulated unsheathed 4.0 Sqmm stranded copper conductor drawn through rigid run metallic in PVC conduit 'meduim grade' with fitting fixed on walls/ceilings with and including PVC FRLS insulated 4.0 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge. Note : 2 runs of 4.0 sqmm PVC insulated unsheathed copper conductor, 1 run 4.0 sqmm PVC insulated unsheathed and one run of PVC conduit shall be measured as single run.
M & L as in repairs submain wiring with two single core cables PVC FRLS insulated unsheathed 6.0 Sqmm stranded copper conductor drawn through rigid run metallic in PVC conduit meduim grade with fitting fixed on walls/ceiling with and including PVC FRLS insulated 6.0 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge. Note : 2 runs of 6.0 sqmm PVC insulated unsheathed copper conductor, 1 run 6.0 sqmm PVC insulated unsheathed and one run of PVC conduit shall be measured as single run.
S & F in repairs of Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20mm dia. (Minimum weight 20mm-210 gms) complete all as spd.
S & F in repairs of Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 15mm dia. (Minimum weight 15mm-142 gms) complete all as spd.
S&F in repairs of Gun - metal globe or gate valve with iron wheel head, screwed both ends for iron pipes and for unions and fixing including taking down existing unserviceable valves complete all as specified and directed for the size 20mm bore dia complete all as specified.
S&F in repairs of Gun - metal globe or gate valve with iron wheel head, screwed both ends for iron pipes and for unions and fixing including taking down existing unserviceable valves complete all as specified and directed for the size 15mm bore dia complete all as specified.
Fabrication of stand for hot water storage tank /FPC (Flat Plate Collector) panel stand by using 60mmx60mmx6mm angle iron, bracings, supports, fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including dismantling old rusted stand all as directed by Engr-in-Charge
M &L for cement concrete PCC 1:2:4 type B1 (using 20 mm aggregrate) as coping complete all as specified and directed
Taking up or down steel water tubing and connections complete all as specified and directed for the size 20mm bore.
Taking up or down steel water tubing and connections complete all as specified and directed for the size 15mm bore.
Taking up or down steel water tubing and connections complete all as specified and directed for the size 25mm bore.
S&F steel of GI pipe, 'medium grade' ISI marked with all fittings fixed to wall complete all as specified and as directed for the sizes 20mm bore
S&F Steel of GI pipe, 'medium grade' ISI marked with all fittings fixed to wall complete all as specified and as directed for the sizes 15mm bore
S&F Steel of GI pipe, 'medium grade' ISI marked with all fittings fixed to wall complete all as specified and as directed for the sizes 25mm bore
S&F in replacement PVC connection 15 mm bore size with PTMT nuts,rubber washers etc complete of length 450 mm long complete all as specified.
S&F in replacement PVC connection 15 mm bore size with PTMT nuts,rubber washers etc complete of length 600 mm long complete all as specified.
S&F in replacement PVC connection 15 mm bore size with PTMT nuts,rubber washers etc complete of length 900 mm long complete all as specified.
Taking down geysers of any make & size from existing position of any height for repair, maintenance and refixing the same after neccesary repair complete all as directed. Notes (i) The defective parts to be replaced and shall be measured and paid separately under relevant item of Sch . (ii) Cost of minor items i.e. Screws, nut & bolts, indicator lamps, mounting bolt & nut etc shall be deemed to be included in the above item.
S&F in replacement heating element 2.0 KW, ISI marked with gasket, nuts, bolts suitable for the existing triangular/round shape/make of the geyser under repair complete all as specified.
S&F in replacement heating element 1.5 KW, ISI marked with gasket, nuts, bolts suitable for the existing triangular/round shape/make of the geyser under repair complete all as specified.
S&F in replacement thermostat (ISI marked) suitable for existing make of the geyser under repair of cap 50/25 Ltrs complete all as specified.
S&F in replacement geyser safety valve (pressure release valve) for the existing make & capacity of geyser complete all as specified.
M&L for painting of geyser of any cap 25/50 Ltr with 2 coats of synthetic enamelled paint after scraping the existing old painted surface complete all as directed.
S&F in replacement syphon assembly suitable for 25 ltr geyser
S&F in replacement syphon assembly suitable for 50 ltr geyser
S&F in replacement inner tank made up of stainless steel conforming to IS suitable for 25 ltr geyser vertical type including rubber gasket complete all as specified and directed.
S&F in replacement inner tank made up of stainless steel conforming to IS suitable for 50 ltr geyser vertical type including rubber gasket complete all as specified and directed.
S&F in replacement outer body made up of steel duly painted including base cover and indicator assembly suitable for 25 ltr geyser complete all as specified and directed.
S&F in replacement outer body made up of steel duly painted including base cover and indicator assembly suitable for 50 ltr geyser complete all as specified and directed.
S&F in replacement Glass wool filling in between inner tank and outer body of geyser of any make and type complete all as specified and directed.
S&F in replacement 3 core PVC insulated PVC sheathed flexible copper wire multistranded of size 2.5 sqmm complete all as specified and directed.
S&F in replacement plug top 3 pin, 15 Amp rating ISI Marked complete all as specified.
Devi Engineeing
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .