Loading…
Loading…
Tender Value
₹13.2 L
EMD Value
₹26,400
Closing Date
5 Aug 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
EL/MTC
3 conditions · 2 needing a document upload
I/we have read the General Conditions of Contract (GCC) with all Correction Slips up to date, NIT, Tender Document, Corrigendum (if issued) carefully and submitted all the relevant documents as per the requirement of Tender Document. I/we understand that if I/we failed to submit any required document, my bid will be liable for summarily rejection.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor has to submit a copy of valid Electrical Contractor License for carrying out installation work of voltage class involved, issued by any State/Central Government along with a supervisor competency certificate as per Regulation 29 of the Central Electricity Authority (Measure relating to Safety and Electric Supply) Regulation 2010 or latest / as per Rules 45 of the Indian Electricity Rules 1956 along with the tender documents, failing which the offer is liable to be rejected.
Electrification work for Provision for additional Store Shed for furnishing items (25x 80 M) in Workshop area RCF Kapurthala.
RCF-EL-MTC-91-ET-26-27
RCF-EL-MTC-91-ET-26-27
Open
Works - General
90 Days
Kapurthala, Punjab
₹0
₹26,400
5 Aug 2026
14 Jul 2026
22 Jul 2026
57 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 13,17,828.2 | ||
| — | 32.00 | — | — | ||
| Supply, erection, testing and commissioning of indoor door/out door Industrial LED roof Light 100 watt luminaries fittings, The installation of fittings includes the supply and providing of all necessary & required accessories for proper fixing, mounting & installation i.e., Brackets, Clamps, Hook, SS and /or Anti-rusted Brass (Electroplated) Fasteners, Nuts, Bolts, Washers and GI bended pipe suitable for hanging or fixing on pillars etc. as required quantity are also in the scope tenderer. The material of mentioned make only | — | — | — | 1,37,600 | |
| — | 16.00 | — | — | ||
| Supply, installation, testing &commissioning of 4 ways Cable Junction Boxes CRCA powder coated with 20 Amp. connector 3 phase with neutral size not less than 180x180x80 mm with cover on truss at required height complete with fixing arrangement and suitable for 4 Core x 16 SQ MM U/A cable. | — | — | — | 4,800 | |
| — | 2.00 | — | — | ||
| Supplying, erecting ,testing & Commissioning of Lighting FDB ,wall/Pillar mounted , made of CRCA sheet steel 1.6 mm, powder coated thickness not less than 40 microns, Incoming 63 Amp SFU front operated with HRC fuses -01nos., Out Going 20 Amp 10 kA SP MCB-10 Nos with suitable DIN rail mounting & Neutral Link Aluminium Bus Bar not less than 15x5mm ,earthing terminals with bolt etc. incoming gland hole for 50Sqmm cable 01 nos at bottom ,Out going Gland hole for 10 sqmm cable 12 nos on top side.(Class of Protection IP-42 ) | — | — | — | 19,934 | |
| — | 1.00 | — | — | ||
| Supply installation testing & commissioning of time light DB with timer. As per explanatory note-4 | — | — | — | 17,000 | |
| — | 250.00 | — | — | ||
| Supply, Laying , fixing , testing & commissioning o f XLPE insulated PVC outer Sheathed aluminum conductor armoured cable 2x10Sqmm suitable for working voltage upto and including 1100 volts conforming to IS: 7098Part-1 )-1988. With amendment number 1&2 &3 reaffirmed 2005.As per Explanatory Note. | — | — | — | 25,000 | |
| — | 200.00 | — | — | ||
| Supply, Laying , fixing , testing & commissioning o f XLPE insulated PVC outer Sheathed aluminum conductor armoured cablesize 4x25Sqmm suitable for working voltage upto and including 1100 volts conforming to IS: 7098Part-1 )-1988. With amendment number 1&2 &3 reaffirmed 2005.As per Explanatory Note. | — | — | — | 41,000 | |
| — | 200.00 | — | — | ||
| Supply, Laying , fixing , testing & commissioning o f XLPE insulated PVC outer Sheathed aluminum conductor armoured cable size 4x50Sqmm suitable for working voltage upto and including 1100 volts conforming to IS: 7098Part-1 )-1988. With amendment number 1&2 &3 reaffirmed 2005.As per Explanatory Note. | — | — | — | 65,000 | |
| — | 20.00 | — | — | ||
| Supplying & making cable End termination of following Aluminium Armoured PVC/XLPE cable. all material required including double compression brass gland , nuts, bolts, PVC tape crimping lugs etc. complete as required for size 2x10Sqmm of aluminum conductor cables. Make as mentioned only. As per Explanatory Note. | — | — | — | 1,400 | |
| — | 6.00 | — | — | ||
| Supplying & making cable End termination of following Aluminium Armoured PVC/XLPE cable. all material required including double compression brass gland , nuts, bolts, PVC tape crimping lugs etc. complete as required for size 4x25Sqmm of aluminum conductor cables. Make as mentioned only. As per Explanatory Note. | — | — | — | 474 | |
| — | 4.00 | — | — | ||
| Supplying & making cable End termination of following Aluminium Armoured PVC/XLPE cable. all material required including double compression brass gland , nuts, bolts, PVC tape crimping lugs etc. complete as required for size 4x50Sqmm of aluminum conductor cables. Make as mentioned only. As per Explanatory Note. | — | — | — | 400 | |
| — | 250.00 | — | — | ||
| Supply, Installation & Commissioning Of 300 MM Wide Cable Tray Made From 35x35x5 MM Angle And Flat Of 25 Mmx5 MM With Painting Two Coats of Smoke Grey. As per explanatory note-7 | — | — | — | 99,500 | |
| — | 2.00 | — | — | ||
| Supply, Installation & Commissioning of Small Tool DB's with IP20 and IK09 degrees of protection having 10Amps- 09 Nos sockets, 20Amp-01 nos , MCB single pole 10Amps- 9Nos& 20Amp.-01 nos ( Industrial Type) and as per technical specification. Drawing approved by RCF with fixing arrangement base plate or u channel angle frame properly with suitable nut bolts or fastener/welding on metal column or RCC wall /pillar as required at site. The material of mentioned makes As per explanatory note-8 | — | — | — | 18,000 | |
| — | 2.00 | — | — | ||
| Supply, Installation and Commissioning of Tap out boxes 300mm widex500 mm longx200mm deep with cover. Powder coated CRCA Sheet thickness shall be 2.5 mm, with aluminium bus bar 50 mm widex5mm thick with DMC insulator base for 3 phase and neutral separately.As per explanatory note-9 | — | — | — | 8,000 | |
| — | 300.00 | — | — | ||
| Supply, wiring, testing and commissioning of light points with 2x2.5sq.mm multi stranded copper conductor, conforming to IS -694-1990, with 1sqmm green multi stranded copper wire as earth). As per Explanatory Note-10 | — | — | — | 17,700 | |
| — | 200.00 | — | — | ||
| Supply & Laying of 8 SWG GI earth wire. as per Explanatory Notes.11 | — | — | — | 2,400 | |
| — | 4.00 | — | — | ||
| Supply, installation and commissioning of single phase 450 mm exhaust fan make : crompton,Bajaj,GEC. As per explanatory note-12 | — | — | — | 21,927.4 | |
| — | 4.00 | — | — | ||
| supply installation testing and comissioning of SPN MCB 32 Amp with enclouser.As per explanatory note-13 | — | — | — | 10,000 | |
| — | 100.00 | — | — | ||
| Breaking of RCC floor / Road and to be given similar finish by providing RCC/bitumin layer as same after laying of Cable as explanatory notes-14 | — | — | — | 29,900 | |
| — | 32.00 | — | — | ||
| Supply of Industrial type Air Circulators ( man cooler ), 610mm Sweep,1440 RPM, rating 1 Hp, 3 phase, 415 V AC, 50 hz, Air delivery not less than 25500 cubic meter/hour at 6 meter, bracket type , IP-44 protection. As per Specification No. RCF/ EL/ MTC/ Mancoolers Dated 8.7.2021 & explanatory Note-15. The material of mentioned make only. | — | — | — | 5,42,204.8 | |
| — | 32.00 | — | — | ||
| Supply installation and commissioning of ( Direct on line) DOL Starter range 1.6 to 2.5 Amperes, Contactor coil voltage 415-440 volt ,Over load relay suitable for 1HP ,3 phase motor in sheet enclosure Make- Siemens,L&Tor BCH only. The material of mentioned make only.As per explanatory note-16 | — | — | — | 44,800 | |
| — | 32.00 | — | — | ||
| Mounting/ Fixing and commissioning of man cooler on wall/pillar by welding of base plate required at site and wiring of man cooler from starter to fan. As per explanatory note-17 | — | — | — | 3,168 | |
| — | 800.00 | — | — | ||
| Supply Wiring , testing and comissioning of Air cirulator with following size of FRLS PVC insulated multi stranded copper conductor FRLS wire size 3x2.5 , conforming to IS-694-1990, in existing MS Conduit 25 mm dia. As per explanatory note-18 | — | — | — | 60,000 | |
| — | 800.00 | — | — | ||
| Supply Wiring , testing and comissioning of Air cirulator with following size of FRLS PVC insulated multi stranded copper conductor FRLS wire size 1x1.5 , conforming to IS-694-1990, in existing MS Conduit 25 mm dia. As per explanatory note-18 | — | — | — | 36,000 | |
| — | 160.00 | — | — | ||
| Supply and Laying of XLPE insulated PVC outer Sheathed aluminum conductor armoured cable 4 x 16Sqmm suitable for working voltage upto and including 1100 volts conforming to IS: 7098Part-1 )-1988. With amendment number 1&2 &3 reaffirmed 2005.As per Explanatory Note-19 | — | — | — | 25,120 | |
| — | 370.00 | — | — | ||
| Supply & providing of MS conduit pipe of 16 SWG 25mm dia ISI marked of mentioned makes only, including bends ,elbows and jn box (conduit pipe shall be clamped at every one meter distance with saddling on ceiling/wall of the area). As per explanatory note-20 | — | — | — | 33,300 | |
| — | 32.00 | — | — | ||
| Supply, installation, testing &commissioning of 4 ways Cable Junction Boxes CRCA powder coated with 20 Amp. connector 3 phase with neutral size not less than 180x180x80 mm with cover on truss at required height complete with fixing arrangement and suitable for 4 Core x 16 SQ MM U/A cable. | — | — | — | 9,600 | |
| — | 4.00 | — | — | ||
| Supply, Installation & Commissioning of DB For Air Circulator, made of CRCA sheet steel 1.6 mm thick, powder coated thickness not less than 40 microns, consisting of(1) Recycling type timer-time setting (sec. to hours) , (2) Single phase preventer ,(3)Power Contactor 3 phase 25 Amp.,(4)MCB TPN 32 Amp/10 KA, internally wired with suitable copper wires. The material of approved make only.As per explanatory note-22 | — | — | — | 39,600 | |
| — | 100.00 | — | — | ||
| Flexible conduit pipe 20sqmm as per Indian Standard as per explanatory notes-23 | — | — | — | 4,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderforStoreshed91.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .