Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. Annual Contractual Turnover Data for the Previous 3/4 Years should be submitted as per Annexure-IX.(AnnexureVIB of Tender Documents)
Technical Eligibility Criteria: (a)The tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. (b) (i)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed any of the following during last 07 seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(i): Separate completed works of minimum required values for each component shall also be considered for fulfillment of technical eligibility criteria. ( c) Similar nature of Work is defined as "Similar nature of Work is defined as "Supply, installation, testing and commissioning of any LT/HT Electrical Work. ." Note: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of opening of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Similar nature of Work is defined as "Supply, installation, testing and commissioning of any LT/HT Electrical Work".
39 conditions · 9 needing a document upload
Check List: The tenderer(s) would fill up the check list, as per Annexure-XXIII to ensure that they are submitting the complete tender offer.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Electrical Work for Replacement of old/dilapidated quarters by construction of: (i) Type-II Quarters (20 units) at CRGN Colony; (ii) Type-II Quarters (20 units) at CKDE Colony; (iii) Type-III Quarters (16 units) at Barbari Colony; (iv) Type-II Quarters (20 units) at Gabrupathar Colony (CKW end); (v) Type-III Quarters (16 units) at Dibrugarh Colony; (vi) Type-II Quarters (20 units) at Gabrupathar Colony (DBRT end); (vii) Type-II Quarters (20 units) at Dibrugarh Colony; (viii) Type-II Quarters (20 units) at Shankar Dev Colony; (ix) Type-II Quarters (20 units) at Kadamoni Colony; and (x) Type-II Quarters (20 units) at Barbari Colony, at TSK Division.
LV-T-14-TSK-965~NFR
LV-T-14-TSK-965
Open
Works - General
12 Months
Tinsukia, Assam
₹0
₹5.4 L
28 Sept 2026
28 Sept 2026
6 Oct 2026
328 items across 10 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 26,93,270 | ||
| Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type wiring of light point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A, ceiling rose, GI box with suitable modules for fixing switches. | — | — | — | 1,56,960 | |
| Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type wiring of Fan Point/Exhaust fan point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A, ceiling rose, Modular GI metal box with suitable modules for fixing switches and 1.0 sq mm multistrand FRLS copper Cable in green for earth contuinity wire. | — | — | — | 1,13,400 | |
| Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type wiring 5 A plug point from main/sub-main board to the points by 1.5 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 5 A,GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire. | — | — | — | 77,040 | |
| Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type wiring 15 A plug point from main/sub-main board to the points by 4 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 15 A , GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire. | — | — | — | 2,21,400 | |
| Supply, fitting, fixing , testing & commissioning of wiring materials for concealed type call bell points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with , GI box with suitable bell push switch 6 amps, bell & ceiling rose and suitable modules for fixing switches. | — | — | — | 14,520 | |
| Supply, fitting, fixing of Wiring materials for Concealed type Geyser point wiring from DB/ sub main board to the points by 4 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 16 A , 3 Module Plate, GI metal flush box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable with 16 A DP MCB C series with DP enclosure in green colour for earth continuity wire. | — | — | — | 77,460 | |
| Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type wiring for AC point from main/sub-main board to the points by 6 mm sq single core multi-strand FRLS copper cable through heavy duty PVC conduit pipe including 16 Amps, AC MCB protected Power point having starter, socket with top & MCB and 1.0 mm.sq. unsheathed copper cable in green colour for earth continuity wire. | — | — | — | 1,08,600 | |
| Supply, fitting, fixing of 5 Step Modular Fan Regulator 2 Module 100W | — | — | — | 25,020 | |
| Supply, fitting, fixing, testing and commissioning of wall mounted type 16 way double door MCB DB having IP 43 protection, Shrouded Neutral Bar & Bus Bar, Cement Spill Protector & Door Earthing with the following domestic switchgears:- (i) RCBO 40 Amps Two pole (2 Module) Conforms to IEC 61009 breaking capacity 10kA, Sesitivity(In)=100mA = 1 No. ii) 40 Amps. DP MCB 'C' series, 240/415 V, 50 Hz, 10 kA BC (In accordance with IS/IEC 60898-1) =1 No. iii) 32 Amps. SP MCB "C" series (In accordance with IS/IEC 60898-1) 240V, 50Hz,10kA =3 Nos. iv) 10 Amps. SP MCB "B" series (In accordance with IS/IEC 60898-1) 240V, 50Hz,10kA =3 Nos V) 25 Amps MCB (DP) "C" series (In accordance with IS/IEC 60898-1) 240V, 50Hz,10kA =3 Nos | — | — | — | 2,75,500 | |
| Supply, fitting, fixing, testing and commissioning of 4 way Double Door SPN MCB DB with IP-43 protection, Door earthing,Neutral Bar,earth bar and bus bar provided with the following MCBS:- (i)MCB DP 63 Amps C series 10KA BC= 2 Nos | — | — | — | 52,400 | |
| Supply, drawing and connection of single core 2.5 sq. mm PVC insulated & unsheathed multistrand FRLHS copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site through walls/surface as required. | — | — | — | 1,17,000 | |
| Supply, drawing and connection of single core 4 sq. mm PVC insulated & unsheathed multistrand FRLHS copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site through walls/surface as required. | — | — | — | 1,11,150 | |
| Supply, drawing and connection of single core 6 sq. mm PVC insulated & unsheathed multistrand FRLHS copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site through walls/surface as required. | — | — | — | 91,800 | |
| Supply, fitting, fixing of Bus Bar Chamber 3 phase and Neutral (4P) with Copper Busbar 63 Amps, 4 way .The busbar chamber to be fabricated using sheet steel (CRCA) of 1.6mm thickness and epoxy powder coated to give superior & lasting finish. The bus bar sections to be made of ETP grade copper & dull tin plated and the bus bar supports are made of DMC (Dough moulding compound). The neutral bus bar to be fully rated. The Bus Bar Chamber should conform to IS:8623/IEC 60439 (Panel sub assemblies) IS: 2147/IEC60529 (Degree for protection) | — | — | — | 48,375 | |
| Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner Sheathed, Armoured Stranded Aluminium Conductor Cable Size 16 Sq. mm, 2 Core, having Galvanized Steel Strip Armour, Extruded PVC Type ST2 Sheathed, 650/1100V Grade as per IS 7098 (Part 1):1988. For cable laying, excavation of earth depth 0.75 Mtrs. and breadth 0.58 Mtrs. below ground level, with a layer of coarse sand of 7.5 cm thickness below and above the cable. The bottom of cable trench shall be levelled and cleared of sharp materials. Above the layer of coarse sand, 3-inch size brick shall be provided for protection of cable. Cable route markers shall be provided at intervals not exceeding 50 Mtrs. All conditions shall be fulfilled as per DRG No. PCEE/ELG/DRG/2024/2 dated 04.10.2024, including laying through building with proper clamping as per supervisor in-charge. | — | — | — | 1,28,100 | |
| Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner Sheathed, Armoured Stranded Aluminium Conductor Cable Size 25 Sq. mm, 2 Core, having Galvanized Steel Strip Armour, Extruded PVC Type ST2 Sheathed, 650/1100V Grade as per IS 7098 (Part 1):1988. For cable laying, excavation of earth depth 0.75 Mtrs. and breadth 0.58 Mtrs. below ground level, with a layer of coarse sand of 7.5 cm thickness below and above the cable. The bottom of cable trench shall be levelled and cleared of sharp materials. Above the layer of coarse sand, 3-inch size brick shall be provided for protection of cable. Cable route markers shall be provided at intervals not exceeding 50 Mtrs. All conditions shall be fulfilled as per DRG No. PCEE/ELG/DRG/2024/2 dated 04.10.2024, including laying through building with proper clamping as per supervisor in-charge. | — | — | — | 1,43,400 | |
| — | — | — | 44,695 | ||
| — | — | — | 27,610 | ||
| — | — | — | 87,080 | ||
| Supply , Fixing and testing of vertical type wall mounted storage Geyser of Capacity 25 Ltrs BEE 5 Star rated , 240V, 50Hz with Maximum power consumption of 2KW , dry powder fero glass line coating technology for inner tank with incoloy heating element with minimum 2 years warranty , ABS outer body , 2 units of PVC connector pipe with length of 450mm length for hot and cold water supply with complete accessories including external knob for temp control and Earth Leakage Circuit Breaker(ELCB). | — | — | — | 2,41,260 | |
| — | — | — | 26,93,270 | ||
| Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type wiring of light point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A, ceiling rose, GI box with suitable modules for fixing switches. | — | — | — | 1,56,960 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocumentTSK965.pdf
ATTACHMENT
AnnexuresSectionVII.pdf
ATTACHMENT
GCCAPRIL2022WITHALLACS.pdf GCC 2022 WITH ACS
ATTACHMENT
GCCAPRIL2022WITHALLACS.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .