Loading…
Loading…
Tender Value
₹2.1 Cr
EMD Value
₹2.6 L
Closing Date
29 Jan 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
SIGNAL
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less, where: - V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case the balance sheet of the previous year is yet to be prepared/audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. Client certificate from other than Govt Organization should be duly supported by Form 16A/26AS generated through TRACES of Income Tax Department of India.
Tenderer must have successfully completed any of the following during last 07 (SEVEN) years, ending last day of month previous to the one in which tender is invited. One Similar work, each costing not less than the amount equal to 60% of the advertised value of the tender. (OR) Two Similar works, each costing not less than the amount equal to 40% of the advertised value of the tender. (OR) Three Similar works, each costing not less than the amount equal to 30% of the advertised value of the tender. Work experience certificate from a Private individual shall not be considered. However, in addition to work experience certificates issued by any Govt Organisation, the work experience certificate issued by Public Listed Company has an average annual turnover of Rs. 500 Crores and above in last 3 Financial Years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least five years prior to the date of opening of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public Listed company to issue such certificates.
SIMILAR NATURE OF WORK: For satisfying eligibility criteria for the subject tender, similar nature of work means "Any signal interlocking works involving EI or RRI or PI or IBS or IBH or LC Gate or Yard modification or UFSBI or Track circuit (AFTC or DC TC) or Axle Counter (SSDAC or MSDAC or HA-SSDAC) or Automatic signaling" Special conditions of contract: a. Submission of 'Undertaking by the tenderer' that the equipment shall be procured from RDSO approved sources and installation, testing and commissioning of equipment shall also be done from the same source including after sales support required during the warranty period. b. After the award of the contract, MOU with RDSO approved source covering supply, installation, testing and commissioning of equipment by the same RDSO approved source including after sales support required during the warranty period, before supply of equipment is undertaken. c. In the MoU, original equipment manufacturer shall: (i) Offer technical support for supply, installation and commissioning of the equipment. (ii) Undertake certification of Factory Acceptance Test. (iii) Undertake verification and certification of pre- commissioning checklist as per RDSO guidelines. (iv) Sign on the Application for Technical System approval by RDSO wherever applicable to ensure that the installation is as per the RDSO stipulations. v) Impart training to Railway officials at their factory premises and at site. (vi) Offer Warranty for equipment as per the condition laid in the tender document and RDSO specification for a period of one year from the date of commissioning. (vii) Guarantee to supply spares for a minimum period of 7 years after the expiry of the warranty period. (viii) Support Railways for entering into AMC/ARC if any on later date after the expiry of warranty period
33 conditions · 9 needing a document upload
Undertaking that the item will be procured from RDSO Approved firm.
Statement of Deviation
Power of Attorney
Certificate to be submitted / uploaded by tenderer along with the tender documents (Annexure V), Part I of GCC.
Annexure-V(A), Part I of GCC (This certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV)/Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc.)
(Bid Security) Bank Guarantee Bond from any scheduled commercial bank of India (Annexure VI(A)
EMD Submitted
List of personnel, organization available on hand and proposed to be engaged for the subject work.
List of plant & machinery available on hand (own) and proposed to be inducted (own and hired to be given separately) for the subject work.
List of works completed in the last three financial years giving description of work, organization for whom executed, approximate value of contract at the time of award, date of award and date of scheduled completion of work. Date of actual start, actual completion and final value of contract should also be given
List of works on hand indicating description of work, contract value, approximate value of balance work yet to be done and date of award.
Copy of PAN card
Documents for Turnover for financial eligibility criteria
Documents for technical eligibility criteria - Performance certificates for single similar nature of work
NEFT Details
GST Registration Certificate Copy
Bid Security Declaration in lieu of EMD Submitted
Organization details
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Power of Attorney
Annexure-V(A), Part I of GCC (This certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV)/Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc.)
(Bid Security) Bank Guarantee Bond from any scheduled commercial bank of India (Annexure VI(A)
NEFT Details
Copy of PAN card
Organization details
GST REGISTRATION/ A CERTIFCATE FOR NON-APPLICABILITY OF GST REGISTRATION
Bid Security Declaration in lieu of EMD Submitted
Replacement of existing Mechanical Lifting Barrier by Provision of Electrically Operated Lifting Barriers and Emergency Sliding Booms at Interlocked LC gates in Arakonnam (AJJ) - Renigunta (RU) section in Chennai Division of Southern Railway
M-SG-2026-493-ELB-AJJ-RU~SR
M-SG-2026-493-ELB-AJJ-RU
Open
Works - General
8 Months
Chennai, Tamil Nadu
₹0
₹2.6 L
29 Jan 2026
6 Jan 2026
15 Jan 2026
45 items across 1 schedule · ₹68,43,487.23 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | "Submission of all relevent final 'As mades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. Onapproval 8 copies shall be made for As- made circuit diagrams also as mentioned above" | Sheet | 140.00 | 382.12 | 53,496.8 |
| 2 | Supply o f earth electrodes (GI) a s p e r Drg no SG/CN/02/13 | Numbers | 70.00 | 1,618.75 | 1,13,312.5 |
| 3 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 70.00 | 1,707.55 | 1,19,528.5 |
| 4 | S u p p l y o f Transformer o f C a p a c i t y 230V A C / 1 1 0 V A C , 1 0 0 0 V A a s p e r RDSO Specifications RDSO/SPN/165 /2012 Ver 3.0 or latest or IRS: S-72 | Numbers | 28.00 | 8,996.32 | 2,51,896.96 |
| 5 | S u p p l y o f 1 2 C x 1 . 5 S Q M M P V C insulated Armoured, unscreened underground Railway Signalling copper cable a s p e r IRS: S-63/2014 REV.4 | Metre | 4000.00 | 215.92 | 8,63,680 |
| 6 | Supply of RCC cable markers (Supply of RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. T h e lettering o n the cable marker shall be "SIG" / "TELE" / "OFC" as per t h e instructions o f Railway representative at site.) as per drawing enclosed | Numbers | 140.00 | 262.65 | 36,771 |
| 7 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule) | Metre | 6000.00 | 64.1 | 3,84,600 |
| 8 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by ram m ing a n d consolidating i t a s p e r the instructions of Railway representative at site a f t e r l a y i n g o f D W C / RC C p i p e s . During excavation of trench, it has to be ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall be from t h e bottom o f sleepers for track crossings. Laying of cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 84.00 | 385.45 | 32,377.8 |
| 9 | Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating it and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply o f DWC/RCC pipes w ith couplers/collars is not included in this schedule). | Metre | 84.00 | 501.03 | 42,086.52 |
| 10 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre | 168.00 | 208.54 | 35,034.72 |
| 11 | Provision of GI pipes (50/100mm dia) for cable laying in hard rocky area with off sets at both ends duly supported by concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).[Stone jelly of size 20/25mm, bricks, sand, cement, a n d a l l o t h e r miscellaneous materials required f o r t h e w o r k s h a l l be supplied by the Contractor]. | Metre | 280.00 | 182.87 | 51,203.6 |
| 12 | Laying o f signaling/power/ telecommunication cables a s p e r cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply o f cables i s n o t included i n this schedule). | Metre | 15400.00 | 18.18 | 2,79,972 |
| 13 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of c a b l e s , a n d consolidating t h e t r e n c h by ramming and levelling." | Metre | 6000.00 | 15.4 | 92,400 |
| 14 | "Digging of pit to a depth of 800mm of size 300mmX300mm, c a s t i n g o f concrete foundation o f s i z e 300mmX300mmX300mm and Placing of RCC cable markers on top of the f o u n d a t i o n a n d r e fi l l i n g t h e p i t and consolidating it by ramming. The cable markers shall b e provided a t a n interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout t h e cable route, diversions and also at every track/road crossing." | Numbers | 140.00 | 123.35 | 17,269 |
| 15 | Excavation o f c a b l e c o i l p i t t o a s i z e of 1.5mx1.5m and depth as instructed by Railway representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus cases etc. The work includes coiling the underground cables and placing closely one layer of country bricks o f size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling. [Country bricks of size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor]. | cum | 7.00 | 949.05 | 6,643.35 |
| 16 | Supply of Relay, Non-AC Immune, plug-in type , Style 'QN1',DC neutral line, 24V, 8F.8B contacts front and back contacts metal to carbon with plug board , retaining clip & connectors confirming to BRS:930, IRS:S 34& IRS:S 23 or latest. The interlocking code for this unit shall be ABDEF. | Numbers | 60.00 | 4,366.63 | 2,61,997.8 |
| 17 | Supply of Relay, AC Immune, plug-in-type, Style 'QNA1', DC Neutral line, 24V, 8F.8B contacts, front and back contacts metal to carbon, with plug board, retaining clip and connectors confirming to BRS:931A, IRS:S 60, IRS:S 34 and IRS:S 23 or latest. The interlocking code for this unit shall be ABDGH. | Numbers | 68.00 | 4,639.03 | 3,15,454.04 |
| 18 | Supply of lamp proving relays(QECX-61) for a)LED aspects with plug boards, connectors and retaining clips with necessary inspection as per specification/ | Numbers | 32.00 | 5,901.5 | 1,88,848 |
| 19 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f plug boards, relays, r e s i s t o r s and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars.[Wire PVC copper, 3/0.75mm and 16/0.2mm c o p p e r , Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, M S fl a t s 2 5 m m x 6 m m brass bolts a n d nuts, paints, soldering materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) | Set | 10.00 | 4,945.51 | 49,455.1 |
| 20 | Supply of powder coated FTOT of 210 capacity | Numbers | 4.00 | 41,627.08 | 1,66,508.32 |
| 21 | Concreting and erection o f cable termination r a c k 500/210/140 Terminals capacity on teakwood base frame of size 50mmx150mm of suitable length and width with rectangular slot in the centre for taking in t h e c a b l e s and painting a s p e r standard practice.(Supply of cable termination racks are not included in this schedule).[Foundation b o l t s a n d n u t s with washers, cement, sand, stone jelly, teak wood base frame 50mmx150mm of suitable length and breadth, p a i n t , varnish a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. a)Concreting and erection of cable termination rack 140/210 capacity | Numbers | 4.00 | 9,752.74 | 39,010.96 |
| 22 | Fixing o f P B T terminal block/ P B T fuse block, rubber grommets, clamping of cables using teakwood c a b l e c l a m p s a n d base planks, termination o f cables, provision of ND type fuses of required capacities, provision of copper bus bar for supply terminals, wiring, provision of termination particulars diagram board using plywood of thickness 12mm - teakwood finish of size 1800mm x 1 2 0 0 m m w i t h Aluminium grooved channel frame i n the relay room. The blank spaces over the top of the cable termination rack shall be covered with phynolic sheet of thickness 3mm wherever required. The termination and cable core particulars shall be painted o n t h e PVC/ nylon sleeves. T h e work a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply of PBT terminal blocks 25mm & 60mm centers a n d P B T Fuse blocks i s not covered in the schedule) [Wire P V C 3/0.75mm copper, brass bolts and nuts a n d washers, f o r fi x i n g PBT terminal/Fuse B l o c k , o t h e r fi x i n g b o l t s and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus b a r s , teakwood 5 0 m m x 50mm for cable c l a m p s , 2 5 m m x 1 0 0 m m f o r base planks, phynolic sheet 6 m m thick o f size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) | Per Unit | 700.00 | 167.99 | 1,17,593 |
| 23 | Fixing o f P B T terminal block/ P B T fuse block, rubber grommets, clamping of cables using teakwood c a b l e c l a m p s a n d base planks, termination o f cables, provision of ND type fuses of required capacities, provision of copper bus bar for supply terminals, wiring, provision of termination particulars diagram board using plywood of thickness 12mm - teakwood finish of size 1800mm x 1 2 0 0 m m w i t h Aluminium grooved channel frame i n the relay room. The blank spaces over the top of the cable termination rack shall be covered with phynolic sheet of thickness 3mm wherever required. The termination and cable core particulars shall be painted o n t h e PVC/ nylon sleeves. T h e work a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply of PBT terminal blocks 25mm & 60mm centers a n d P B T Fuse blocks i s not covered in the schedule) [Wire P V C 3/0.75mm copper, brass bolts and nuts a n d washers, f o r fi x i n g PBT terminal/Fuse B l o c k , o t h e r fi x i n g b o l t s and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus b a r s , teakwood 5 0 m m x 50mm for cable c l a m p s , 2 5 m m x 1 0 0 m m f o r base planks, phynolic sheet 6 m m thick o f size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. b)Termination using PBT fuse block in cable termination rack (Per Unit = Per Fuse Block) | Per Unit | 98.00 | 201.27 | 19,724.46 |
| 24 | Concreting and erection of Relay racks- 168/56 relay capacity using 'J' type bolts and painting of relay rack as per the instructions of Railway representative at site.(Supply o f relay rack is not covered in this schedule).['J' type bolts and nuts with washers, nylon bushes, concreting materials, paint a n d all other miscellaneous materials required for the w o r k s h a l l be supplied b y the Contractor]. b)Concreting and erection of relay rack - 56 capacity | Numbers | 4.00 | 3,015.04 | 12,060.16 |
| 25 | Fixing o f plug boards, 5 0 w a y terminal blocks with 2BA terminals, and wiring of relays as per t h e approved circuit diagram using w ire PVC 16/0.2mm coppe r. Suitable wire supporting tray with cover made of PVC shall b e provided horizontally a n d vertically in the relay racks.. While running the wires on the aluminium ladder proper care shall be taken t o provide smooth materials like rubber beading in the openings on Phynolic sheets, to avoid damage to wires. The work also includes w i r i n g of contacts for data logger and terminating them i n t a g blocks, provision of relay index board. (Supply of relays, plug boards, connectors and retaining clips is not covered i n this schedule). [Wire P V C 16/0.2mm copper, t a g blocks, 2BA terminals, hard w oo d plank o f size 600mmx 900mmx25mm with decolum finish, M S angles o f size 25mmX25mmX6mm, relay fixing bolts and nuts, teakwood plank 25mm thick for fixing resistors and condensers, phynolic sheet 6 m m t h i c k o f s i z e 1200mmX1800mm with aluminium grooved channel f r a m e f o r relay i n d e x b o a r d , p a i n t s , s o l d e r i n g materials, b u n c h i n g t h r e a d , w i r e w o u n d resistance, condenser, wire supporting tray with cover of suitable size made of PVC, paint, varnish and a l l other miscellaneous materials required for the work shall be supplied by the Contractor]. | Per Relay | 132.00 | 1,045.76 | 1,38,040.32 |
| 26 | Fi x i n g o f additional p l u g boards, 5 0 ways terminal blocks and wiring o f additional relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC shall b e provided wherever required. Alterations to Relay particulars shall be incorporated in the relay Index board.(Supply o f r e l a y s , plug boards, connectors and retaining clips a n d 50 w a y terminal boards i s n o t covered i n this schedule).[Wire PVC 16/0.2mm copper, 2 BA terminals, teakwood p l a n k 2 5 m m t h i c k for fi x i n g r e s is t o r s a n d condensers, soldering m a t e r i a l s , b u n c h i n g t h r e a d , w i r e wound resistance, condenser, w i r e supporting tray with cover of suitable size made of PVC, paint, varnish a n d a l l other miscellaneousmaterials required for the work shall be supplied by the Contractor ] | Per Relay | 20.00 | 726.5 | 14,530 |
| 27 | Carrying out alterations to the existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire PVC 16/0.2mm copper. T h e work includes painting alterations a n d releasing the unwanted wires carefully without disturbing the existing wiring. [ W i r e P V C 1 6 / 0 . 2 m m c o p p e r , soldering m a t e r i a l s , b u n c h i n g t h r e a d s , condensers, resistances and teakwood plank for fixing them and all other miscellaneous materials required f o r t h e w o r k s h a l l b e s u p p l i e d by the Contractor]. | Per Relay | 140.00 | 695.67 | 97,393.8 |
| 28 | Supply o f B I S listed Semi-automatic Stainless Steel preventive device with UL approved clean gas with Auto manual Reverse Stainless Steel v a l v e ' N A S A 400 MAR' or similar having capacity of 4kg, and made o f stainless steel 304 grade with Indian Railway logo put on each unit. | Per Unit | 28.00 | 35,219.46 | 9,86,144.88 |
| 29 | Supply o f D o u b l e w a l l e d corrugated p i p e - 1 0 3 . 5 m m i n n e r d i a & 1 2 0 m m o u t e r dia conforming t o specification N o . IS 14930(Part 2): 2001 with one coupler for every 6m of pipe as per Technical specification | Metre | 168.00 | 365.19 | 61,351.92 |
| 30 | Supply of GI pipes - 100mm dia-4.5mm thick as per Technical specification | Metre | 448.00 | 1,119.16 | 5,01,383.68 |
| 31 | Supply o f PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre. | Numbers | 1428.00 | 61.44 | 87,736.32 |
| 32 | Supply o f PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre. | Numbers | 252.00 | 93.02 | 23,441.04 |
| 33 | Supply o f PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse | Numbers | 117.00 | 103.84 | 12,149.28 |
| 34 | Supply of apparatus cases (full/ half/ quarter size) to suit Southern Railway standard with necessary inspection a s p e r specification/ drawing/ description enclosed in this document a)Supply of apparatus case - Full size | Numbers | 14.00 | 18,821 | 2,63,494 |
| 35 | Excavation o f pit, casting concrete foundation and erection of apparatus case full size a s per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this schedule).[Foundation bolts & nuts, 'E' type locks, cement, M sand, stone jelly of size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fi x i n g b o l t s & n u t s a n d a l l other miscellaneous materials required f o r thework shall be supplied by the Contractor.] | Numbers | 14.00 | 11,333.1 | 1,58,663.4 |
| 36 | Termination o f n e w main/tail cables o n the existing terminals/ fuse blocks in apparatus c a s e s / b a t t e r y b o x e s / C T b o x e s / cable termination r a c k s a s p e r approved circuit diagram. T h e terminal particulars a r e to be repainted /corrected on the doors of apparatus cases/ battery boxes/ cable termination boxes and FTOT index board as instructed by Railway representative at site. This w o r k includes closing t h e opening created f o r entry o f new cables i n the apparatus cases w i t h masonry b r i c k work and sealing t h e b o t t o m o f the apparatus cases/ cable termination racks with cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm copper, s e a l i n g compound, bricks, cement, M sand and all other required miscellaneous materials shall b e supplied by the contractor].(Per Unit = Per Terminal block) | Per Unit | 210.00 | 73.59 | 15,453.9 |
| 37 | Termination of main, tail, Signaling and power cables a n d internal wiring on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood i t e m s , fi x i n g of terminals/ fuse blocks o n t h e terminal board, drilling of necessary h o l e s , termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as per approved circuit diagram a n d cable plan, painting o f particulars o n sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, the side openings o f apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand u p t o base level and the bottom surface shall be sealed with sealing compound.(Supply of PBT terminals and Fuse blocks is not c o v e r e d i n t h i s schedule)." a)Termination on 25/60mm PBT terminals (new location)(Phynolic sheet)(Per Unit = Per Terminal block) | Per Unit | 700.00 | 172.14 | 1,20,498 |
| 38 | Termination of main, tail, Signaling and power cables a n d internal wiring on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood i t e m s , fi x i n g of terminals/ fuse blocks o n t h e terminal board, drilling of necessary h o l e s , termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as per approved circuit diagram a n d cable plan, painting o f particulars o n sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, the side openings o f apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand u p t o base level and the bottom surface shall be sealed with sealing compound.(Supply of PBT terminals and Fuse blocks is not c o v e r e d i n t h i s schedule)." b)Termination on PBT fuse block (new location) (Phynolic sheet)(Per Unit = Per Fuse block) | Per Unit | 98.00 | 209.93 | 20,573.14 |
| 39 | Termination of main, tail, Signaling and power cables and internal wiring b y fixing additional terminals/ fuse blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as per approved circuit diagram a n d cable plan, painting o f particulars o n sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings o f apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand u p t o base level and the bottom surface shall be sealed with sealing compound. a)Termination o f c a b l e s on 25/60mm PBT terminals (existing location)(Per Unit = Per Terminal block) | Per Unit | 280.00 | 151.09 | 42,305.2 |
| 40 | Termination of main, tail, Signaling and power cables and internal wiring b y fixing additional terminals/ fuse blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as per approved circuit diagram a n d cable plan, painting o f particulars o n sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings o f apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand u p t o base level and the bottom surface shall be sealed with sealing compound. b)Termination of cables on PBT fuse block (existing location)(Per Unit = Per Fuse block) | Per Unit | 56.00 | 188.86 | 10,576.16 |
| 41 | Providing the services of Computer oriented technical manpower t o carryout w o r k s like D r a w i n g , computation, w r i t e u p e t c . , using computer, using software like AUTOCAD, MS O ffi c e etc., f o r 08.00 h r s i n a d a y w i t h all expenses of transportation, accommodation, f o o d , consumables e t c . , w i t h a l l ascents, descents, t a x e s , octro i, c e s s , f e e s , duties, duties with contractors cost etc., as per special conditions/ specifications/ regulations and as directed by Engineer-in-charge. Note: The person engaged for providing the services shall b e c o n v e r g e n t w i t h computer working knowledge in above software. | Man- Days | 140.00 | 913.28 | 1,27,859.2 |
| 42 | Protection adjustments and re-instating of S&T gears by deputation of Helpers/Unskilled Labour for executing additional S&T portion of t h e w o r k s . The work can involve fixing, releasing, dismantling, replacement,excavation, clearing of vegetation, loading and unloadingof material and assisting skilled persons etc as per instruction of Railway representative. | Man- Days | 560.00 | 847.59 | 4,74,650.4 |
| 43 | Transportation o f Signalling materials by road a s p e r t h e instructions o f Railway representative a t site. T h e work also includes l o a d i n g a n d u n l o a d i n g o f the materials a)Transportation o f Signalling materials upto 100kms | MT-Km | 2800.00 | 22.75 | 63,700 |
| 44 | Transportation o f Signalling materials more than 100km | MT-Km | 2800.00 | 13.91 | 38,948 |
| 45 | Engaging mechanical excavators like JCB or other machineries for regarding and levelling t h e form atio n, dismantling a n y infringing structures, clearing a n d removing debris etc., with all leads and lifts etc., complete and as per t h e instruction o f Railway representative at site. | Hour | 28.00 | 1,202.5 | 33,670 |
| Schedule total | ₹68,43,487.23 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .