Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC AIRPORT ROAD SKALZANGLING LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹33.2 L+₹4.8 L (16.9%)Rejected-Finance NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹35.9 L+₹7.5 L (26.4%)Rejected-Finance 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹35.9 L+₹7.5 L (26.4%)Rejected-Finance BUDOOBAGH NOWPORA 0 KHANYAR SRINAGAR JAMMU KASHMIR 190003 | SRINAGAR | JAMMU AND KASHMIR | 190003 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹47.1 L+₹18.7 L (66.0%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹47.8 L
EMD Value
₹95,600
Closing Date
3 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CDR, HQ 138 WE
HQ 138 Works Engineers PIN-914138 C/O 56 APO
REPAIR/ REPLACEMENT AND MAINT OF CENTRAL HEATING PLANT AND HOT WATER PLANTS WITH CONNECTED WORKS INSTALLED AT OTM ACCN OF GH, FSH AND CHARLIE MESS UNDER AGE E/M-II OF GE 865 EWS LEH
2024_MES_664365_1
138WE/L-42/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 865 EWS
Refer tender documents
6 documents required · 6 mandatory
₹500
GE 865 EWS
₹95,600
Yes
16 Nov 2024
6 Jul 2024
10 Sept 2024
6 Jul 2024
3 Sept 2024
20 Jul 2024
Amount
Dismantling of burner assembly of CHS and remvoing of side cover and repairing the same by removing the old burnt fire refractory cement plastering, replastering the same as per existing with fire refractory cement for boiler capacity 3-4 lakh kilo cal/hr and complete servicing the boiler by removing the complete carbon/oil deposits with suitable coil shine chemical including repair to coil assembly by welding if there is any leakages found or any other repair required at site and reassembling/ testing the same, (4 Months after again service) complete all as specified and directed by Engr-in Charge.
Dismantling of burner assembly of CHS and remvoing of side cover and repairing the same by removing the old burnt fire refractory cement plastering, replastering the same as per existing with fire refractory cement for boiler capacity 1-2 lakh kilo cal/hr and complete servicing the boiler by removing the complete carbon/oil deposits with suitable coil shine chemical including repir to coil assembly by welding if there is any leakage found or any other repair required at site and reassembling/ testing the same, (4 Months after again service) complete all as specified and directed by Engr-in Charge.
S&F temp controller digital TC513A/TC513AX/TC533AX 85 to 270 Volt AC/DC 50/60 Hz 5 VA type/ (DTC 304-2) with sensor suitable for 3-4 lakh kilo Cal/hr & Oil fired incinator including burner rod assembly (As per sample), complete all as specified and directed by Engr in Charge.
S&F in replacement of photo cell as per existing suitable for 3-4 lakh kiloCal/hr burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F in replacement of burner nozzle suitable for 3-4 lakh KCal/Hr complete all as specified and directed by Engr in charge.
S&F in replacement of Electrode suitable for burner of capacity 3-4 lakh KCal/Hr complete all as specified and directed by Engr in charge.
S&F in sequence controller suitable for 3-4 lakh kilo Cal/hr with burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F in replacement of ignition rod suitable for 3-4 lakh kiloCal/hr burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F in sequence controller suitable for 1-2 lakh kilocal/hr with burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F in replacement of ignition rod suitable for 1-2 lakh kiloCal/hr burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F in replacement of ignition Transformer electronic type suitable for 1-2 lakh kilo/Cal/hr burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F temp controller digital TC513A/TC513AX/TC533AX 85 to 270 Volt AC/DC 50/60 Hz 5 VAtype DTC 503 with sensor suitable for 1/2 lakh kiloCal/hr LAL 2.25 burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F in replacement of photo cell as per existing suitable for 1-2 lakh kiloCal/hr burner rod assembly, complete all as specified and directed by Engr in Charge.
S&F in replacement of burner nozzle suitable for 1-2 lakh K Cal/Hr complete all as specified and directed by Engr in Charge.
S&F in replacement of Electrode suitable for burner of capacity 1-2 lakh K Cal/Hr complete all as specified and directed by Engr in Charge.
M & L for Servicing of Air Handling Unit capacity 26000 CFM including repair to coil assy by welding if there is any leakage found and testing the same, replacement bearings of motor capacity 7.5 HP/10HP, reassembling/ testing the same including painting of AHU with two coats of aluminium paint over a coat of red oxide primer and cleaning of AHU room complete all as specified and directed by Engr-in-Charge.
Labour only for attending of break down/day to day complaint or call on attending any break down or maint work in CHS located in GH OTM,FSH and "C" Mess and MTF checking the serviceability of fan coil unit of any capacity for having continuous sreviceability of FCU for any number of time as desired by Engr-in-Charge including replacement of minor spare part like Gasket, Teflon tape, flare nut, tightening of any loose glycol line connections, shifting FCU from one place to another place if required, heating up the freezed glycol line any where about the premices to have continuous flow of glycol fluid, repairing the insulation of pipe line of any size by providing shallow tape / GI wire as deemed fit, for fastening the insulation with pipe line, stopping any kind of leakage from any size of pipe line, tightening the loose electrical connections as related with FCU / Heating system, cleaning the air filter including radiator of FCU to the entire satisfaction of Engineer-in- Charge complete all as directed at site.
S&F in replacement of pressure gauge 0 to 20 Kg/Sqcm as per existing,complete all as specified and directed by Engineer-in-Charge.
S &F in replacement of Bridge rectifier complete all as specified and directed by Engr in Charge.
S &F in replacement of hooter round type complete all as specified and directed by Engr in Charge.
S&F in replacement of thermostate assembly tail type as per existing suitable for 0 to 30 degree centrigrade temperature, complete all as specified and directed by Engr in Charge.
M&L for repair of exaust pipe by welding, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of auto air pressure valve 3/8" as per existing, complete all as specified and directed by Engr in Charge.
S&F in replacement of High pressure fuel pipe 1.5 mtr as per existing,complete all as specified and directed by Engr in Charge.
Material and labour for taking down and Re fixing the same after rewinding of electric motor 3 phase 415 volts of capacity 7.5/10 HP with superior quality super enameled copper winding wire of appropriate size and gauge as per existing including varnishing , cotton tape, PVC sleeves etc, complete all as specified and directed by Engr-in-Charge.
Material and labour for taking down and Re fixing the same after rewinding of electric motor 3 phase 415 volts of capacity 5.0 HP with superior quality super enameled copper winding wire of appropriate size and gauge as existing including varnishing , cotton tape, PVC sleeves etc, complete all as specified and directed by Engr-in-Charge.
Material and labour for taking down and Re fixing the same after rewinding of electric motor 3 phase 415 volts of capacity 3.0 HP with superior quality super enameled copper winding wire of appropriate size and gauge as existing including varnishing , cotton tape, PVC sleeves etc, complete all as specified and directed by Engr-in-Charge.
Material and labour for taking down and Re fixing the same after rewinding of electric motor single phase 240 volts of capacity 1-2 HP with superior quality super enameled copper winding wire of appropriate size and gauge as per existing including varnishing , cotton tape, PVC sleeves etc, complete all as specified and directed by Engr-in-Charge.
M&L for replacement of bearing of capacity 7.5 HP monoblock motor (as per sample) complete all as specified and directed by Engr-in-charge
M&L for replacement of SS impeller of capacity 7.5 HP monoblock motor (as per sample) complete all as specified and directed by Engr-in-charge
M&L for replacement of mechanical seal for monoblock motor of capacity 7.5 HP (as per sample) complete all as specified and directed
M&L for tail end cooling fan for monoblock motor of capacity 7.5 HP non metalic (as per sample) complete all as specified and directed
M&L for base frame for monoblock motor of capacity 7.5 HP (as per sample) complete all as specified and directed
M&L for pump sleeve for monoblock motor of capacity 7.5 HP (as per sample) complete all as specified and directed
M&L for replacement of bearing of capacity 5 HP monoblock motor (as per sample) complete all as specified and directed by Engr-in-charge
M&L for replacement of SS impeller of capacity 5 HP monoblock motor (as per sample) complete all as specified and directed by Engr-in-charge
M&L for replacement of mechanical seal for monoblock motor of capacity 5 HP (as per sample) complete all as specified and directed
M&L for tail end cooling fan for monoblock motor of capacity 5 HP non metalic (as per sample) complete all as specified and directed
M&L for base frame for monoblock motor of capacity 5 HP (as per sample) complete all as specified and directed
M&L for pump sleeve for monoblock motor of capacity 5 HP (as per sample) complete all as specified and directed
M&L for replacement of bearing of capacity 3 HP monoblock motor (as per sample) complete all as specified and directed by Engr-in-charge
M&L for replacement of SS impeller of capacity 3 HP monoblock motor (as per sample) complete all as specified and directed by Engr-in-charge
M&L for replacement of mechanical seal for monoblock motor of capacity 3 HP (as per sample) complete all as specified and directed
M&L for tail end cooling fan for monoblock motor of capacity 3 HP non metalic (as per sample) complete all as specified and directed
M&L for base frame for monoblock motor of capacity 3 HP (as per sample) complete all as specified and directed
M&L for pump sleeve for monoblock motor of capacity 3 HP (as per sample) complete all as specified and directed
M&L for servicing to the glycol pump and motor of capacity 3.0 HP, 2870 RPM including replacement of bearings, oil seals or any other spares / work required for smooth functioning of pump, complete all as specified and directed by Engr in Charge.
M&L for servicing to the glycol pump and motor of capacity 5.0 HP, 2870 RPM including replacement of bearings, oil seals or any other spares / work required for smooth functioning of pump, complete all as specified and directed by Engr in Charge.
M & L for disconnecting the all connection in existing panel board complete and re-fixing the same after removing the burnt lugs/thimbles complete including replacing the U/S MCCBS, Contactors, relay, bus bar indicator lamps etc., all as specified and as direcrted by Engr-in-Charge. Note- MCCBS, Contactors, relay, indicator lamps, S/Switches, voltmeter, Ammeter are to be measured and paid seperately.
Supply and fix diesel flexible pipe of size 25 mm for glycol pump complete all as specified and directed by Engr-in-Charge.
Supply and fix contactor type 3 TF 33, 415 volts complete all as specified and directed by Engr-in-Charge. Make- Siemens, L & T , Havells
Supply and fix contactor type ML 1.5, 220 volts, complete all as speified and directed by Engr-in-Charge. Make- Siemens, L & T , Havells
Supply and fix over load relay 8 to 12.5 Amps for contactor matching ser No 48 series 3 TF 33 complete all as specified and directed by Engr-in-Charge. Make- Siemens, L& T , Havells
Supply and fix over load relay 1.25 to 2 Amps for contactor matching ser no 49 series 3 TF 33 complete all as specified and directed by Engr-in-Charge. Make- Siemens, L& T , Havells
Supply and fix in replacement of digital type volt meter 0-500 volts, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of digital type Amp meter complete with suitable CTs 0-300 Amps, complete all as specified and directed by Engr-in-Charge.
Supply and fix replacement of indicating lamps RYB as per existing complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of rotary type ON/OFF switches, 22mm dia as per existing, complete all as specified and directed by Engr-in-Charge.
Supply fix in replacement of push button switch in RED or GREEN colours, 22mm dia as per existing, complete all as specified and directed by Engr-in-Charge.
Supply and fix MCCB with current rating 160 Amps 415 V 4 Pole 36 KA with thermally adjustable complete all as specified and as directed by Engr-in-Charge.
Supply and fix MCCB with current rating 200 Amps 415 V 4 Pole 36 KA with thermally adjustable complete all as specified and as directed by Engr-in-Charge.
Supply and fix MCCB with current rating 100 Amps fixed type 415 V 3 Pole 16 KA complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of PVC flexible copper multistrand wire 3 core of 6 sqmm as per existing, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of PVC flexible copper multistrand wire 3 core of 4 sqmm as per existing, complete all as specified and directed by Engr-in-Charge.
M & L for Insulation of MS Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of size of 80 mm dia of pipe, complete all as specified and directed by Engr in Charge.
M & L for Insulation of MS Pipe with PUF slab 30 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of size of 50 mm dia of pipe, complete all as specified and directed by Engr in Charge.
M&L for welding the leakage portion of MS pipe line including all T&P and materials required for welding the pipe line of size 25 mm to 200 mm including testing on full pressure complete all as specified and directed by Engr in Charge.
S&F in replacement of gun metal butterfly control valves of 65 mm bore as per existing, complete all as specified and directed complete all as specified and directed by Engr in Charge.
S&F in replacement of gun metal butterfly control valves of 80 mm bore as per existing, complete all as specified and directed complete all as specified and directed by Engr in Charge.
S&F in replacement of gun metal butterfly control valves of 50 mm bore as per existing, complete all as specified and directed complete all as specified and directed by Engr in Charge.
S&F in replacement of gun metal butterfly control valves of 40mm bore as per existing, complete all as specified and directed complete all as specified and directed by Engr in Charge.
Supply and replcement of MS pipe (ERW) heavy duty including fittings complete of size 100 mm dia complete all as specified and directed by Engr in Charge. (Note- The rate include cutting to any levels/shapes like elbows,teesbends etc welding joints wherever necessary as per the site requirement)
Supply and replcement of MS pipe (ERW) heavy duty including fittings complete of size 80 mm dia complete all as specified and directed by Engr in Charge. (Note- The rate include cutting to any levels/shapes like elbows,teesbends etc welding joints wherever necessary as per the site requirement)
Supply and replcement of MS pipe (ERW) heavy duty including fittings complete of size 50 mm dia complete all as specified and directed by Engr in Charge. (Note- The rate include cutting to any levels/shapes like elbows,teesbends etc welding joints wherever necessary as per the site requirement)
Supply and replcement of MS pipe (ERW) heavy duty including fittings complete of size 40 mm dia complete all as specified and directed by Engr in Charge. (Note- The rate include cutting to any levels/shapes like elbows,teesbends etc welding joints wherever necessary as per the site requirement)
Supply and replcement of MS pipe (ERW) heavy duty including fittings complete of size 25 mm dia complete all as specified and directed by Engr in Charge. (Note- The rate include cutting to any levels/shapes like elbows,teesbends etc welding joints wherever necessary as per the site requirement)
Supply and replcement of MS pipe (ERW) heavy duty including fittings complete of size 20 mm dia complete all as specified and directed by Engr in Charge. (Note- The rate include cutting to any levels/shapes like elbows,teesbends etc welding joints wherever necessary as per the site requirement)
S&F in replacement of FCU connection flexible pipe 20/16 mm as per existing, complete all as specified and directed by Engr in Charge.
S&F in replacement of FCU connection copper pipe 20/16 mm with check nut at both side as per reqd length, complete all as specified and directed by Engr in Charge.
Supply and fix switch socket combination of 5 Amp flush type complete all as specified and directed by Engr in Charge.
S&F in replacement of plug top 3 pin of capacity 5 Amp complete all as specified and directed by Engr in Charge.
M&L for Electrical Control Wiring for FCU of any size including electronic display complete as per sample all as specified and directed by Engr in Charge.
Dismantling the existing radiator unit of capacity from 3000 to 6500 K Cal per hour, taking it to nearest workshop cleaning the complete unit with coil shine chemical, detecting the leakage protion by applying nitrogen gas pressure, brazing the leakage protion, refixing the same unit from dismantled location including testing on load complete all as directed at site by Engineer-in- Charge.
Supply and fixing radiator unit of FCU including connecting with the unit and making it leak proof of consisting of copper coils covered with aluminium finshing as per existing size of capacity 3000 K Cal / Hour including dismantling the existing unserviceable.
Supply and fixing radiator unit of FCU including connecting with the unit and making it leak proof of consisting of copper coils covered with aluminium finshing as per existing size of capacity 4500 K Cal / Hour including dismantling the existing unserviceable.
Supply and fixing radiator unit of FCU including connecting with the unit and making it leak proof of consisting of copper coils covered with aluminium finshing as per existing size of capacity 6000 K Cal / Hour including dismantling the existing unserviceable.
Supply and fix in replacement of needle valve 3/8 inch BSP as per existing complete all as specified and directed by Engr in Charge.
S&F in replacement of ring 'O' Clip of flexible pipe of existing size complete all as specified and directed by Engr in Charge.
Supply and fix Inlet/outlet forged brass ball valve 20 mm with Y stainer for FCU, hot water for 25 to 90 degree temperature as per existing, including supply and fixing of GI nipple of size 3/4 inch including welding work cutting the existing rusty unserviceable MS/GI nipple complete including taking out existing unserviceable valve complete all as specified and directed.
Supply and fix Inlet/outlet forged brass ball valve 15 mm with Y stainer for FCU, hot water for 25 to 90 degree temperature as per existing, including supply and fixing of GI nipple of size 3/4 inch including welding work cutting the existing rusty unserviceable MS/GI nipple complete including taking out existing unserviceable valve complete all as specified and directed.
Supply and fix in replacement of fan Coil unit of capacity 3000 Cal/Hr with mounting arrangement on wall including all connected accessories complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of fan Coil unit of capacity 4500 Cal/Hr with mounting arrangement on wall including all connected accessories complete all as specified and directed by Engr-in-charge
S&F in replacement of Oil Pressure pump 7276-3D67A Complete all as specified and directed by Engr-in-Charge
S&F in Repair/Replacement of fan coil unit parts, dual shaft electric motor of capacity 30 Watt 930 RPM, 3 speed as per existing complete all as specified and directed by Engr-in-Charge
Supply and replacement of PP-R pipe with fitting of 40 mm dia complete all as specified and directed by Engr-in-Charge
Supply and replacement of PP-R pipe with fitting of 32 mm dia complete all as specified and directed by Engr-in-Charge
Supply and replacement of PP-R pipe with fitting of 25 mm dia complete all as specified and directed by Engr-in-Charge
Supply and replacement of PP-R pipe with fitting of 20 mm dia complete all as specified and directed by Engr-in-Charge
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for foundation , laying of pipes , cables etc. or for manholes pier holes poles not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in hard /dense soil complete all as specified and directed by engr in Charge. Note: Excavation for rectifying the Leakage for CHS Pipe of any dia .
Returning filling in soil including spreading levelling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed by Engr in Charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 above the starting point including spreading and levelling complete all as specified and directed by Engr in Charge.
S&F in replacement Temp controller regulator type complete (as per sample) all as specified and directed by Engr-in-Charge
S&F in replacement of lagging all around with 150mm thick sections bonded material wool of density 144 Kg/cum conforming to IS 9842 for heating circulation pipe lines 150 MM over chicken wire mess complete all as specified and directed by Engr-in-Charge Note: Retrived glass wool to be disposed off by the contractor
S&F in replacement of lagging all around with 100mm thick sections bonded material wool of density 144 Kg/cum conforming to IS 9842 for heating circulation pipe lines 100 MM over chicken wire mess complete all as specified and directed by Engr-in-Charge Note: Retrived glass wool to be disposed off by the contractor
S&F in replacement of lagging all around with 80mm thick sections bonded material wool of density 144 Kg/cum conforming to IS 9842 for heating circulation pipe lines 80 MM over chicken wire mess complete all as specified and directed by Engr-in-Charge Note: Retrived glass wool to be disposed off by the contractor
S&F in replacement of lagging all around with 65 mm thick sections bonded material wool of density 144 Kg/cum conforming to IS 9842 for heating circulation pipe lines 65 MM over chicken wire mess complete all as specified and directed by Engr-in-Charge Note: Retrived glass wool to be disposed off by the contractor.
S&F in replacement of lagging all around with 50/40 mm thick sections bonded material wool of density 144 Kg/cum conforming to IS 9842 for heating circulation pipe lines 50/40 MM over chicken wire mess complete all as specified and directed by Engr-in-Charge Note: Retrived glass wool to be disposed off by the contractor
M&L for Galvanised Iron Pipe Medium grade of size 50 mm dia complete with all fitting and fixed complete to walls and ceillings or laid in floors complete all as specified and directed by engr in Charge.
M&L for Galvanised Iron Pipe Medium grade of size 40 mm dia complete with all fitting and fixed complete to walls and ceillings or laid in floors complete all as specified and directed by engr in Charge.
M&L for Galvanised Iron Pipe Medium grade of size 25 mm dia complete with all fitting and fixed complete to walls and ceillings or laid in floors complete all as specified and directed by engr in Charge.
M&L for Galvanised Iron Pipe Medium grade of size 20 mm dia complete with all fitting and fixed complete to walls and ceillings or laid in floors complete all as specified and directed by engr in Charge.
S&F in replacement of complete burner assembly including all connected accessories suitable for 1-2 lakh kilo/Cal/hr including installation, testing & commissioning (As per Sample) complete all as specified and directed by Engr in Charge.
S&F in replacement of complete burner assembly including all connected accessories suitable for 3-4 lakh kilo/Cal/hr including installation, testing & commissioning (As per Sample) complete all as specified and directed by Engr in Charge.
S&F in replacement of ignition Transformer electronic type suitable for 3-4 lakh kilo/Cal/hr burner rod assembly, complete all as specified and directed by Engr in Charge.
Supply and fixing and replacement of chilled/hot water fan coil unit (FCU) vertical type floor mounting 2.5 TR capacity complete all as specfied and directed by Engr-in-charge. Make: Carrier/Zeco or equivalent ISI marked make as approved by GE
Supply and fixing and replacement of chilled/hot water fan coil unit (FCU) wall mounting 2.0 TR capacity complete all as specfied and directed by Engr-in-charge. Make: Carrier/Zeco or equivalent ISI marked make as approved by GE
Supply and fixing and replacement of wall mounted (ECO Panel) convector heater 2.5 KW/Hrs two heat out put set up with auto control and LED temperture display. Dimension - width 1200 mm, height 450 mm ,depth 90mm with complete fixing accessories complete all as specified and as directed. (Note : Old U/S converter heater to be deposited in MES store Yard
Supply and laying cable XLPE Insulated screened PVC bedded galvanized steel strip or wire armored, electric power cables (heavy duty) 11000 Volts grade with standed aluminium conductor of following sizes 95 sqmm 3.5 Core laid in trenches or passing through pipes ducts or fixed to walls/poles including taking down old cable complete all as specified and directed.
Supply and laying cable XLPE Insulated screened PVC bedded galvanized steel strip or wire armored, electric power cables (heavy duty) 11000 Volts grade with standed aluminium conductor of following sizes 120 sqmm 3.5 Core laid in trenches or passing through pipes ducts or fixed to walls/poles including taking down old cable complete all as specified and directed.
Supply, connection and testing of thermal heater wires on water supply pipe lines (GI/MS/PPR) FOR HEATING OF WATER THROUGH MINIMUM 25 Watt per meter in spiral/ straight line shape above outer diameter of pipe with aluminium tape insulation to preserve heat, fiber glass layer, second layer of aluminium tap to hold fiber glass by glass wool minimum 40mm thick with essential tapes, complete all as specified and directed by Engr-in-Charge.
M&L for Cleaning of MS diesel storage tanks (day to day tank) of capacity up to 1000 ltrs by removing of sludge from tanks and scrapping the side walls by means of wire brush or emery paper and wash the same with castic soda and clear water and painting the internal wall with two coats of black rubber emulsion paint and painting the complete tank with two coats of synthetic enamel paint, complete all as specified and directed by Engr-in-Charge.
M&L for Cleaning of MS diesel storage tanks of capacity up to 10000 ltrs by removing of sludge from tanks and scrapping the side walls by means of wire brush or emery paper and wash the same with castic soda and clear water and painting the internal wall with two coats of black rubber emulsion paint and painting the complete tank with two coats of synthetic enamel paint, complete all as specified and directed by Engr-in-Charge.
M&L for Cleaning of MS over head circulation tank of capacity 1000 ltrs of all type of T&P and chemical reqd the same , including welding work to lekage surface including opeaning and refixing the existing insulating material to the externalal surface including painting the complete tank from out side with two coats of synthetic enamel paint, complete all as specified and directed by Engr-in-Charge.
S S BUILDERS (BID ID -3076716)
EESSI (BID ID -3074683)
Top Mind Industries Pvt Limited (BID ID -3076088)
national engineering (BID ID -3078528)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .