Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.4 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹41.7 L+₹8.3 L (24.8%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹44.6 L+₹11.1 L (33.3%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹97,280
Closing Date
28 Sept 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR AND MAINT OF ROOF LINTEL CHAJJAS AND REPAIR TO RCC STRUCTURE COMPONENTS OF BLDGS UNDER AGE BR I OLD NAVYY NAGAR COLABA MUMBAI
2022_MES_547360_1
8257/E8
Open Tender
Civil Works
Item Rate
270 days
GE (NW) Navy Nagar, Colaba
Class D Category a (i)
8 documents required · 8 mandatory
₹500
Yes
GE NW NAVY NAGAR COLABA MUMBAI
₹97,280
26 Nov 2022
24 Aug 2022
29 Sept 2022
24 Aug 2022
28 Sept 2022
15 Sept 2022
24 Aug 2022 - 21 Sept 2022
Amount
Demolition of damaged / cracked / lose concrete / plaster of ceiling / wall / chajja to expose the sound and hard concrete using a suitable mechanical device or by hammer and chisel, etc. The chipping shall be carried out to such depths that the rods are fully exposed to the best possible.complete all specified and directed by Engineer-in-charge.
M&L for applying cement based waterproofing coating with high negative hydrostatic, good adhesion to substrate and enhanced durabiltiy on concrete or masonry walls. The waterproofing coating should have adhesion to substrate of 1.3 Mpa after 28 days, elasticity modulus of 14000 - 16000 N/mm2 after 28 days and average water/ powder demand of 0.24 to 0.26 for fluid consistency. complete all specified and directed by Engineer-in-charge
M&L for a CO^2 diffusion barrier system with end OH group system with following properties: System Properties:UV resistance (ASTM G 154): No Change in colour, IR Spectrum (IR Spectrometer standards): Acrylic polymer with end OH groups shall be present, Adhesion (ASTM D 4541): >3.25MPa, Dry Film Thickness, (Primer +two coats) Solid Content (By mass) as per IRC SP80 (IS-354): >67%, Water vapour permeability (ASTM D 1653): <2.20 gm/sqm/day at 75% RH at 25°C, Flexibility (Standard Bend test) ¼ Inch Mandrel (ASTM D 522): No cracks shall develop, Water Penetration test (DIN-1048): Shall pass, AC Impedance test in 3% NaCl (ASTM G 106): Initial: >9.0x109 ; After 30 days: >1.5x107, Diffusion Resistance against CO2 (DIN 53122 Part 1): 2.28 g/m2xd (typical), Diffusion equivalent air layer thickness (SD) (DIN 53122 Part 1): >100m, Diffusion resistance number (DIN 53122 Part 1): 43µ (typical), Water proofing characteristics: >50 % reduction in flux Electrochemical Polarization test (Accelerated corrosion test) a.Rebar weight loss method : Efficiency Factor – 20 (typical), b.Chloride penetration : Efficiency Factor – 14 (typical), Resistance to alkali (IS 5411): Should have No blistering, No popping, No change in colour, Fungal Resistance (IS 5411): Should have No fungal growth, No blistering, No popping, No change in colour, Elongation (ASTM D 2370): >100%., at all levels to achieve an even shade including all labour, materials, consumables, scaffolding, equipment, handling, transportation, protection and cleaning etc. complete all specified and directed by Engineer-in-charge.
M&L for providing and applying a blend of Portland cement, graded fillers and chemical additives which impart controlled expansion, should be ready to use and can fill convoluted voids and cracks , it should componsates shrikage at both plastic and Hardened states. W/P ratio of 0.18. Strength of 1 day to be 20N/mm2. Time of expansion to start after 20min of mixing and finish in 120 min of mixing epoxy bonding agent having mix density of 1.45 to 1.5 kg/ltr, compressive strength (BS-6319 PT 3)-25 Mpa at 7 days bond strength (ASTM C 881)-11 N/mm2 at 7 days, including all tools and tackles as per accepting officer, complete all as specified and directed by Engr-in-Charge.
M&L for single component, homogenous pre-mixed powder blend of hydraulic cement and other fillers to achieve a certain PSD/gradation, with additives to compensate shrinkage, free flowing which is to be used to restore sections where the thickness is more than 50 mm. The maximum W/P ratio is 0.14. Once hydration starts, the initial setting of the mix should not be less than 120 mins. Epoxy bonding agent conforming to ASTM C 881 and having a long tackfree time of 120 mins at 30°C should be appiled to the substrate prior to pouring to achieve sufficeint stress transfer. The strength at 24 hours and 7 days should be 10 MPa and 40 MPa respectively.complete all specified and directed by Engineer-in-charge.
M&L for providing and applying three component system based on BPA and having a mix proportion of 2PBW:1PBW:15-17PBW. The compresive strength shall be minimum 50 Mpa. Subsequent layers may be applied after 24 hours. The mixture should be non shrink , high mechanical strength, strong in flexural, compressive and bond strength.complete all specified and directed by Engineer-in-charge.
Providing and Applying corrosion inhibiting, single component, fibre reinforced, thixotropic, dual shrinkage compensated, thixotropic pumpable mix which should conform to JIS Z 1535. The mortar should have a compressive strength of not less than 40 N/mm2 after 28 days curing. The W/P ratio by weight should be 0.165 and the mass density should be in the range of 1750-1850 Kg/m3 and it should be suitable for vertical and overhead application . The application should be done up to thickness of 20 mm in one layers which is suitable for all structural elements and also repairs of structural members subjected to static/dynamic loading and repairs to core members of industrial structures.Cement and sand can be used for finishing the surface even and smooth Rate should inclusive of material, labour, scaffolding, tools and tackles,complete all specified and directed by Engineer-in-charge.
M&L for drilling holes at the location of cracks upto a depth of 75 -100 mm and a dia of almost 14-20 mm and cleaning those holes prior to application. nipples should be fixed in these holes which are to spaced at 1m c/c. A high strength polymer based on BPA and having viscosity less than 200 cps at 25°C and a 7 days compressive strength of minimum 70 MPa.complete all specified and directed by Engineer-in-charge.
M&L for providing and fixing welded MS wire mesh weighing not less than 1Kg/Sqm of size on the prepared surface & surface should be cleaned and be removed from dirt, fungus and all foreign material complete all as specified and directed by Engineer in Charge.
M&L for providing and applying one part alkaline based material, with corrosion inhibitors and dispersing agents for exposed steel after cleaning to loose scale or oxidized chips from bars, having bulk density 1.25. The material to be applied to the rusted metal with brush for complete wetting of rusted metal surface and allowed to react for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal / steel for about 5-7 days. Before applying protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth, etc.Complete all as specified and directed by Engineer-in-charge.
M&L for applying curing of the surface using water based acrylic emulsion which incorporate specially for its water retention properties. It shoud be non-penetrating continuous film complying with the internationally recognized ASTM C309-90 standards @ 250gms/Sqm. Product should have daylight Reflectance of 70% as per ASTM E-1347 Specific Gravity of 1-1.01 curing efficieny greater than 70% Minimum application temperature 10°C.complete all specified and directed by Engineer-in-charge.
M&L for applying two coats of Epoxy Resin Based Concrete Bonding Agent for proper bonding between old surface with micro-concrete/new surface.The bonding agent shall be a two component solvent free epoxy supplied as ready to use at site. The product shall have a minimum pot life of 120 Min at 35°C and an open time of atleast 4-6 Hours @ 30°C up to which new concrete can be poured. It shall develop a minimum compressive strength of 40 MPa and a bond Strength of 11 MPa.complete all specified and directed by Engineer-in-charge.
M&L for providing and applying two coats of one part alkaline based material, with corrosion inhibitors and dispersing agents for exposed steel after cleaning to loose scale or oxidized chips from bars, having bulk density 1.25. The material to be applied to the rusted metal with brush for complete wetting of rusted metal surface and allowed to react for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal / steel for about 5-7 days. Before applying protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth, etc.Complete all as specified and directed by Engineer-in-charge.
M&L for drilling hole chemical anchoring of reinforcement on existing surface with Hilti HIT-HY 70 or equivalent, minimum hole depth 150mm, steel bar 10mm dia and drill bit dia 12mm, complete all as specified and directed. Make: HT-V-R- M12x150 of Hilti Chemical anchoring polyester resin grout having compressive strength of 20N/mm2 @ 3 hours and an ultimate compressive strength of 70N/mm2 in 7 days (50mm x 50mm x 50mm)when tested as per BS 6319 Part 2 : 1983, complete all specified and directed by Engineer-in-charge.
M&L for external/internal Plastering of Surface using Fiber reinforced polymer modified repair mortar.The product shall be a single component thixotropic fiber reinforced polymer modified repair mortar needing only addition of water at site which can be applied by trowel. It is reinforced with specially designed bean shaped, alkali resistant synthetic fibers for exceptional resistance to cracking. It is recommended for repair situations requiring application of mortar up to 15-20mm thickness in one layer.Cement and sand can be used for finishing purpose. The product shall achieve a compressive strength of 11 MPa in 1 day & 30 MPa in 28 days and a minimum flexural strength of 6 MPa @ 7 days. It shall have a tensile strength of minimum 2 MPa. It shall have a minimum bond strength of 2 MPa. complete all specified and directed by Engineer-in-charge.
M&L for Sprinkling sand particles on the final layer of saturant making mechanical key, over which applying Single component, fiber reinforced cementitious repair mortar which is reinforced with specially designed bean shaped, alkali resistant synthetic fibers for exceptional resistance to cracking for a thickness of 10 mm.cement and sand can be used for finishing the surface smooth and even ,water ratio of which shall be 0.16, 28 days compressive strength shall be 30 MPa,mixed density shall be 2.18 kg/ltr, flexural strength shall be 6 MPa for 7 days and tensile strength for 7 days shall be more than 2MPa.Its adhesion bond strength shall be greater than 2 MPa with creep strain reduction of 8%. The modulus of elasticity of this product shall be 23-26 KN/mm². complete all specified and directed by Engineer-in-charge.
M&L for treating the existing pipe penetrations using non-shrink, free flowing, cementitious grout .The compressive strength of the grout must exceed 50 N/mm2 at 7 days and 60 N/mm2 at 28 days. The flexural strength of grout must exceed 9N/mm2 @ 28 days. Fresh wet density of the mixed grout must exceed 2150 kg/m3. Further flashing the area using solvent based UV resistant polyurethane based waterproofing material having minimum tensile strength on 4 N/mm2 and minimum elongation of 800%. Complete all as specified and directed by Engineer-in-charge.
M&L for applying Polyster Resin based Anchoring material in concrete before fixing nozzle it should typically attains a compressive strength in excess of 20N/mm @ 3 hours and and ultimate compressive strength of 70N/mm in 7 days (50mm x 50mm x 50mm)when tested as per BS 6319 Part 2 : 1983. complete all as specified and directed by Engr-in-charge.
M&L for providing and fixing of heavy grade nipple 15 mm dia,100 mm long for injection grouting using grouting polymer having low viscosity, high molecular weight, thermosetting to reach very deep pores, voids, cracks and honeycomb in the concrete, specific gravity of which shall be 0.95, pH of 2-4,viscosity of 20-25 sec by B/4 ford cup and having curing time of 30-90 minutes in all area by suitable gun/pump at required pressure (100 bar to 150 Bar, including cutting of nipples after curing etc and sealing the nozzles with three component agent exhibiting greenish yellow finish on curing solvent free thyxotropic having 100% solid content epoxy resin base density up to 1.68 gm/cc having seven day compresive strength of 50MPa, pot life 40 minutes at 25°C,drying time 8 hrs at 25°C and applicable with minimum temperature of 10°C. Recoatable time 24 hrs after finishing in line and level with existing concrete surface etc complete all as specified and directed by Engineer in Charge.
M&L for form work to sides and soffits of lintels, beams, columns, shelves, chajjas including overhangs etc for fair finished flat surface, complete all as specified and directed by Engr-in-charge
M&L for MS TMT bars 8mm dia and over as in reinforcement cut to length, bent to shape required including cranking bending spirally for hooping for columns, hooking ends & binding with and including MS annealed wire not less than 0.9mm dia complete all as specified and directed by the Engineer-in-Charge
Note: (a) The work for item Sr No. 1 to 22 to shall be executed directly by company or their authorized applicator. Application shall be authorized in writing by company and guarantee/responsibility of work executed shall be owned by Contractor in writing for 5 years. (b) Quoted rate shall be inclusive of material all labors tools and plants scaffolding and working upto 15 mtr height. (c) Adoption of necessary safety arrangement like safety belts. ropes. helmets, netting etc. which are required for safety of working at height etc. which are required for safety of working at height exceeding 3 to 25 mtr height shall be mandatary and deemed to be inclusive on quoted rates.
M/s Raghav Traders
M/s R.D. Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .