Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 2ND FLOOR PLOT NO E 19 104 155 BLOCK E P NO 19 SECTOR 3 ROHINI NORTH WEST DELHI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance NO 4 24 FIRST FLOOR SHIVAYA NAGAR MAIN ROAD ALAGAPURAM SALEM 636016 TAMIL NADU | SALEM | SALEM | TAMIL NADU | 636016 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
11 Feb 2023, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer
Garrison Engineer (AF) Sulur. MES Kangyampalayam
To carry out soil investigation and Design of building as per plan attached
2022_MES_571804_2
3009/QTN/JOB/04/E3 dated 28 Dec 2022
Open Tender
Job Works
Works
30 days
GE (AF) Sulur
Please refer tender documents
2 documents required · 2 mandatory
₹0
Exempted
13 Feb 2023
28 Jan 2023
13 Feb 2023
28 Jan 2023
11 Feb 2023
28 Jan 2023
Amount
SCHEDULE A BOQ
Name of Wok:- Provision of Qty-02 Additional rooms in existing station Armoury premises at Air force station Sulur & Work sevices for induction of AK-103 Rifles at 43 Wing Airforce Station Sulur Mobilisation of Mechanical drilling equipment on site and shifting of entire arrangement from one bore to another bore hole location and setting of boring/drilling rig as required/directed by Engineer-in-charge.
Boring 150mm dia bore hole up to 12 m depth to collect 100mm dia UDS through following type of strata :-
a) Any type of Soil. No of bore holes = 01 No (Total Depth of bore hole 12 m)
(b) Soft Rock. (c) Hard Rock
Collection of undisturbed soil sample at 1.50 M intervals or at any change of strata in 100mm bore thin walled tube including waxing sealing, packing and transporting to the lab.
Carrying out standard Penetration Test (SPT) including collection of disturbed Soil samples in bore holes at every 1.50 M depth or any change of strata and submit the report with all requisite data.
Conducting necessary tests as per relevants IS codes-1892 / NBC 2005 / SP 36 on all collected samples which include the determination of :- (a) Atterberg Limits (b) Wet and dry density degree of saturation of soil. (c) Unit weight (Bulk density),Natural Moisture content, Liquid limit, plastic limit, Shrinkage limit,plasticity Index Specific gravity. (d) Grain size analysis Identification & classification of soil. Soil particle size distribution using sieve / Hydrometer analysis. (e) Shear perameter (C-Phi Analysis) Tri-axial shear test C-Phi and determination. (f) Shrinkage limit. (g) Consolidation test & permeability test. (h) Specific gravity test for Sand/Rock.
(j) Crushing strength of rock samples, Find out RQD value and degree of weathering (CR Value). (k) Permeability test. (l) Chemical analysis of ground water sample (Water to be obtain from bottom of bore hole) (Min 02 Sample). (m) Differential Free Swelling Index (%) & swelling pressure if Expansive soil encountered. (n) Depth of water table below Ground Level. (o) Presence of loose soil, if any and its depth. (p) If weak soil with lesser N value as specified in Table-1 of IS 1893 (Part-102016 is encounter then evaluation of liquefaction potential shall be assessed and remedial action to be adopted shall be specified. (q) Chemical analysis of soil
Design of building in single storey with minimum height at inner side 3.20 m and 3.85 m from FFL and outer dimension of building as per plan attached in MES standard pattern and as required and directed by Engineer-in-charge (with different height for each room. Plan Elevation attached). (i) Structural Design calculations for the structure are to be provided in hard/soft copy. (ii) All Structural drawing duly marked with reinforcement details and other dimensions are to be submitted in triplicate. (iii) Architectural drawing and Structural drawings of footing, column, Beam, slab etc in A1 size (3 Sets) to be supplied and soft copy shall be submitted (in AUTOCAD and PDF file. Grade of concrete to be mentioned). (iv) The rates are to be including all taxes. (v) In case of design is carried out by private consultant the same shall be vetted from Govt Engineer College/ NIT/IIT. (vi) Any other details required for execution of the work will also be submitted (eg. Schedule of finish). (vii) Brick / PCC block masonry wall with thickness 690 mm, 460 mm, 345 mm as shown in attached plan. (viii) Details of RCC roof slab and fibre grass roof are shown in attached elevation. Note:- Combined floor plan and front elevation is attached for your guidance.
Detailed item rate estimation (BOQ) for single storage building as per MES Standard Pattern (prepricing as per SSR 2020) with soft copy in excel format and 04 set of hard copy shall be submitted by the Consultant.
Submission of report in four sets giving site plan showing test points, sub soil profile, results of field investigations, laboratory test results, calculation of SBC from SPT test, comprehensive type of foundation. Note : (i) Rate includes all items of work necessary for carrying out complete soil exploration work, collection of sample, testing at laboratory and field test results and submission of reports (Four sets). (ii) Rate includes for submission of detailed calculation of Net SBC at 1.5/2.0/2.5/3.0 M depth from shear as well as settlement criteria. SBC shall be calculate based on C-Phi analysis as well as STP value. For calculation formulae given in IS-6403 shall be used. Type of foundation and depth of footing be clearly specified. (iii) In case very weak soil strata is encountered, recommendation about pile foundation i.e Type, Dia, Depth of pile, Safe load carrying capacity and socketing of pile into hard rock shall be clearly given in the report. (iv) Safe bearing capacity shall be worked out based on N value, shear failure and settlement criteria.
(v) The rates are Excluding of all taxes (vi) Four set of report with site plan showing cross reference to each soil investigation bore hole CBR/K value test location. All pages of reort will be serially numbered, stamped and signed by every page by counsultant. Vetting of the report/ reccomendation from IIT/NIIT/IISC Banglore to be done or from any Govt Engg College.
SAKTHI DEVELOPMENTS COY
MEENAKSHI GEOTECH
stage.html
html • 0.02 MB
finance_647238.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .