E.E E-400 KV S/S DIVISION-I MURADNAGAR
E.E E-400 KV S/S DIVISION-I MURADNAGAR
Supply of Different type ( of material at 400 KV S/S Division-I Muradnagar
2026_UPTCL_1190015_1
T-02/E400KVSSDI/M/2026-27
Open Tender
Supply of Materials
Fixed-rate
30 days
E-400 KV S/S DIVISION-I MURADNAGAR
AS PER PQR
2 documents required · 2 mandatory
₹590
AS PER NIT
Exempted
25 Sept 2026
25 Sept 2026
19 Oct 2026
25 Sept 2026
19 Oct 2026
25 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply of silica gel, blue color, 5-8 mm beads, in crystal form and a self indicating desiccant crystal suitable for power transformers use . | 75 | Kg. | - | - |
| 2 | Supply of thermal overload relay , 3 pole, range 4-6 A with 1 NO and 1 NC auxiliary contact suitable for the motor of air compressor of 400 kv sf-6 CGL make circuit breaker as per sample & Indian standard. | 5 | No. | - | - |
| 3 | Supply of thermal overload relay , 3 pole, range 14-23 A suitable for the motor of jockey pump of E-mulsifier system as per sample & Indian standard. | 4 | No. | - | - |
| 4 | Supply of power contactor, 3 pole, rated operational current 9 A, thermal current 25 A, coil voltage 415 volt, 50 hz AC with 1 NO and 1 NC auxiliary contact suitable for the motor of air compressor of 400 kv sf-6 CGL make circuit breaker as per sample & Indian standard. | 5 | No. | - | - |
| 5 | Supply of dol starter control panel complete with analog voltmeter and ammeter, thermal bimetallic relay for protection against overload/ unbalanced load, single phase preventer and power contactor suitable for 5 hp, 3-ph., 415 volt, 50 hz motor pump set of sump pump. | 2 | No. | - | - |
| 6 | Supply of dol starter control panel complete with analog voltmeter and ammeter, thermal bimetallic relay for protection against overload/ unbalanced load, single phase preventer and power contactor suitable for 7.5 hp, 3-ph., 415 volt, 50 hz submersible motor pump set of e-mulsifier system . | 1 | No. | - | - |
| 7 | Supply of dol starter control panel complete with analog voltmeter and ammeter, thermal bimetallic relay for protection against overload/ unbalanced load, single phase preventer and power contactor suitable for 10 hp, 3-ph., 415 volt, 50 hz submersibble motor pump set . | 1 | No. | - | - |
| 8 | Supply of Female contact assambly suitable for 245 kv , 1250 amp. Electrolyte make isolator. The contact assembly shall be fabricated with 06 no. of electroytic copper fingers, having silver plating with steel springs provided between the fingers alongwith all necessary fixing arrangements as per sample. | 6 | No. | - | - |
| 9 | Supply of male contact assambly suitable for 245 kv , 1250 amp. Electrolyte make isolator. The contact assembly shall be fabricated with 02 no. of electroytic copper, cylindrical in shape , having silver plating alongwith all necessary fixing arrangements as per sample. | 5 | No. | - | - |
| 10 | Supply of VSP D2 phase failure relay, supply- 3-ph,380-440 volt AC, 50 hz, phase unbalance setting- adjustable 30-70 volt, aux. supply - 415 volt AC as per sample and Indian standard. | 2 | No. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
TENDERFORMBl.pdf
Tender Documents • 0.21 MB
BOQT2.xls
Additional Documents • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .