Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹14.9 L+₹2.7 L (22.5%)Rejected-AOC | L2 | Rejected-AOC Being L2 bidder | |
| 3 | L3₹16.5 L+₹4.3 L (35.6%)Rejected-AOC | L3 | Rejected-AOC Being L3 bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical As agency not submitted the shortfall document | |
| 5 | Rejected-Technical | - | Rejected-Technical As agency not submitted the shortfall document |
| Sl No | Description | Qty | Unit | M/S Renesys Power Systems Private Limited L3 | Naturetech Infrastruture Pvt. Ltd. L2 | INSTANT ELECTRIC SERVICES L1 |
|---|---|---|---|---|---|---|
| 1.10 | Design, supply, installation, testing and commissioning of Rooftop Solar PV Systems Conforming to MNRE Specifications Consisting of Mono Crystalline Silicon Solar Cells, Net metering facility, necessary Protections, Earthing, Mounted on Hot Dip Galvanized Structure of Suitable Strength with Following Components:
i)Solar PV Mono Crystalline half cut module 540 Wp or above capacity, manufactured in India conforming to IS 14286/IEC, 61215, IS/IEC61730-Part-1, IS/IEC 61730-Part-2. Solar photovoltaic module conversion efficiency shall not be less than 16.5%, PV modules use solar power plant must be warranted for their output peak watt capacity which should not be less than 90% at the end off 10 years and 80% at the end of 25 years.
ii)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50°C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. Data Monitoring System complete with accessories.
iii)DCDB & ACDB with Energy Meter & remote monitoring system (Ethernet/Wireless based)
iv) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable: along with glands, lugs and other accessories as required.
v) Galvanized Iron Solar PV Structure suitable for seashore environment (Heavily Corrosive) for Sloppy Sheet metal roof mounted system or as per site requirement.
vi) Lightning and surge voltage protection i/c 2 No. of lightening protection, 2 no. of AC earthing, 4 No. of DC earthing.
vii) AICMC of above said Solar power Plant for 05 years after expiry of DLP 02 years.
viii) Connections & Interconnections by supplying & fixing required size XLPE insulated copper/Al. conductor 1.1 kV grade armoured AC & DC power cable as below-
a.Suitable AC Cable(Inverter to ACDB) & (ACDB to Panel)
b.1x4 sqmm DC Cable including MC4 connector
c.control cables if required
along with supplying & fixing of necessary and other lugs channel/conduit accessories etc. ( As per Annexure "K" Drawing)
ix) Carrying out Glint/Glare Analysis if Required at site for safe flight operations, shadow analysis, clearance/approval from DISCOM, CEA and other statuatory agencies, transportaions & insuarnce of materials etc and all other items/ acessories/ services which are required for successful commissioning of Solar Power plant complete as required as per technical specifications & terms & conditions of the contract.
x) Automatic Solar Panel Cleaning system with spraying Nozzle. ( As per Annexure "L" Drawing) | 30.52 | kWp | 53,900 ₹16,45,028 | 48,700 ₹14,86,324 | 39,750 ₹12,13,170 Lowest |
Tender Value
₹16.8 L
EMD Value
₹50,331
Closing Date
8 Aug 2025, 5:00 pmClosed
JGM(E-E)
Airports Authority of India, Vadodara Airport
Provision of 30.52 KW Roof Top Solar Power System at Diu airport
2025_AAI_241108_1
AAI/WR/EE/SOLAR/DIU/N5/2025-26
Open Tender
Electrical Works
Works
120 days
Diu Airport
Please refer Tender documents.
17 documents required · 17 mandatory
₹1,180
₹50,331
19 Sept 2025
16 Jul 2025
11 Aug 2025
16 Jul 2025
8 Aug 2025
16 Jul 2025
16 Jul 2025 - 6 Aug 2025
Amount
Design, supply, installation, testing and commissioning of Rooftop Solar PV Systems Conforming to MNRE Specifications Consisting of Mono Crystalline Silicon Solar Cells, Net metering facility, necessary Protections, Earthing, Mounted on Hot Dip Galvanized Structure of Suitable Strength with Following Components: i)Solar PV Mono Crystalline half cut module 540 Wp or above capacity, manufactured in India conforming to IS 14286/IEC, 61215, IS/IEC61730-Part-1, IS/IEC 61730-Part-2. Solar photovoltaic module conversion efficiency shall not be less than 16.5%, PV modules use solar power plant must be warranted for their output peak watt capacity which should not be less than 90% at the end off 10 years and 80% at the end of 25 years. ii)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50°C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. Data Monitoring System complete with accessories. iii)DCDB & ACDB with Energy Meter & remote monitoring system (Ethernet/Wireless based) iv) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable: along with glands, lugs and other accessories as required. v) Galvanized Iron Solar PV Structure suitable for seashore environment (Heavily Corrosive) for Sloppy Sheet metal roof mounted system or as per site requirement. vi) Lightning and surge voltage protection i/c 2 No. of lightening protection, 2 no. of AC earthing, 4 No. of DC earthing. vii) AICMC of above said Solar power Plant for 05 years after expiry of DLP 02 years. viii) Connections & Interconnections by supplying & fixing required size XLPE insulated copper/Al. conductor 1.1 kV grade armoured AC & DC power cable as below- a.Suitable AC Cable(Inverter to ACDB) & (ACDB to Panel) b.1x4 sqmm DC Cable including MC4 connector c.control cables if required along with supplying & fixing of necessary and other lugs channel/conduit accessories etc. ( As per Annexure "K" Drawing) ix) Carrying out Glint/Glare Analysis if Required at site for safe flight operations, shadow analysis, clearance/approval from DISCOM, CEA and other statuatory agencies, transportaions & insuarnce of materials etc and all other items/ acessories/ services which are required for successful commissioning of Solar Power plant complete as required as per technical specifications & terms & conditions of the contract. x) Automatic Solar Panel Cleaning system with spraying Nozzle. ( As per Annexure "L" Drawing)
Naturetech Infrastruture Pvt. Ltd. (BID ID -883230)
M/S Renesys Power Systems Private Limited (BID ID -874489)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .