| Sl No | Description | Qty | Unit | P. M. COOLING AND ENGINEERING CO L3 | M.S. COOLING & ENGINEERING CO. L1 | Shinryo Suvidha Engineers India Pvt. Ltd. L2 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantaling the existing A.C Machine1.5Tr,2Tr,7.5Tr,11Tr[WRAC/SRAC] (including electrical connection) both indoor & outdoor, Copper pipes etc and submit the pwd section office as per direction of EIC. (Total 28 Nos concealed Split AC/WRAC/SRAC) | 1 | Item | 25,000 ₹25,000 | 45,000 ₹45,000 | 6,500 ₹6,500 |
| 2.00 | Erection, testing and commissioning charges for the The Indoor (IDU) and Outdoor(ODU) of 1.5Tr,2Tr,7.5Tr,11Tr concealed Split AC/WRAC/SRAC. as per direction & satisfaction of EIC. | 28 | Nos | 2,500 ₹70,000 | 3,000 ₹84,000 | 600 ₹16,800 |
| 3.00 | Copper Refrigeration pipe line for Liquid Line hard drawn Cu piping (1/4" OD with 0.6 mm thick) & Copper Refrigeration pipe line for Suction Line hard drawn Cu piping (5/8" OD with 0.7 mm thick) with necy supports & brackets as per direction of EIC | 250 | Rmt | 485 ₹1.2 L | 450 ₹1.1 L | 800 ₹2 L |
| 4.00 | Supply & Fixing of Nitrile Rubber tube insulation (make : Twiga) of 9 mm thick on Suction & Liquid Line Copper Pipe including taping. | 250 | Rmt | 145 ₹36,250 | 100 ₹25,000 | 160 ₹40,000 |
| 5.00 | Control Cabling from Condensing Unit to Control Panel, 4 core 2.5 sq.mm. communication Cable (Mk. Finilex / Havell's/ KEI/Gloster) | 250 | Rmt | 225 ₹56,250 | 180 ₹45,000 | 155 ₹38,750 |
| 6.00 | S&charging of R-410 refrigerant | 18 | Kg | 1,025 ₹18,450 | 950 ₹17,100 | 950 ₹17,100 |
| 7.00 | Supply & laying PVC Drain Pipe 25 mm dia with necy claming arrangement as per direction of EIC | 150 | Rmt | 110 ₹16,500 | 100 ₹15,000 | 105 ₹15,750 |
| 8.00 | Supply, Installation, testing & commissioning of Inverter type Concealed type split AC machine (a set of full metal body indoor and outdoor unit) having cooling capacity not less then 7.0 kw with veriable speed rotary/ scroll compressor, refrigerant gas R32/R410 or better, both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments. (Make - Mitsubishi Electric/ Daikin/ Ogeneral/ Hitachi/ Voltas/ Blue Star) | 1 | Nos | 61,000 ₹61,000 | 58,000 ₹58,000 | 69,000 ₹69,000 |
| 9.00Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work) (Rate should be quotated including all taxes and duties) | ||||||
Tender Value
Refer Docs
EMD Value
₹8,100
Closing Date
25 Mar 2026, 1:00 pmClosed
Assistant Engineer, KMC Electrical Sub-Division
Kolkata Medical College Electrical Sub-Division, P.W.Dte.Green Building, MCH Campus 88, College Street, Kolkata-700073.
Through repair and rehabilitation of the distressed/dilapidated condition of inside and out side portion Regional institute of Opthalmology RIO Building under Medical College and Hospital, Kolkata. Work of AC.
2026_WBPWD_1021048_1
WBPWD/AE/KMCESD/NIQ-174/25-26
Open Tender
A/C ORG
21 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹8,100
13 Apr 2026
11 Mar 2026
27 Mar 2026
18 Mar 2026
25 Mar 2026
18 Mar 2026
Dismantaling the existing A.C Machine1.5Tr,2Tr,7.5Tr,11Tr[WRAC/SRAC] (including electrical connection) both indoor & outdoor, Copper pipes etc and submit the pwd section office as per direction of EIC. (Total 28 Nos concealed Split AC/WRAC/SRAC)
Erection, testing and commissioning charges for the The Indoor (IDU) and Outdoor(ODU) of 1.5Tr,2Tr,7.5Tr,11Tr concealed Split AC/WRAC/SRAC. as per direction & satisfaction of EIC.
Copper Refrigeration pipe line for Liquid Line hard drawn Cu piping (1/4" OD with 0.6 mm thick) & Copper Refrigeration pipe line for Suction Line hard drawn Cu piping (5/8" OD with 0.7 mm thick) with necy supports & brackets as per direction of EIC
Supply & Fixing of Nitrile Rubber tube insulation (make : Twiga) of 9 mm thick on Suction & Liquid Line Copper Pipe including taping.
Control Cabling from Condensing Unit to Control Panel, 4 core 2.5 sq.mm. communication Cable (Mk. Finilex / Havell's/ KEI/Gloster)
S&charging of R-410 refrigerant
Supply & laying PVC Drain Pipe 25 mm dia with necy claming arrangement as per direction of EIC
Supply, Installation, testing & commissioning of Inverter type Concealed type split AC machine (a set of full metal body indoor and outdoor unit) having cooling capacity not less then 7.0 kw with veriable speed rotary/ scroll compressor, refrigerant gas R32/R410 or better, both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments. (Make - Mitsubishi Electric/ Daikin/ Ogeneral/ Hitachi/ Voltas/ Blue Star)
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work) (Rate should be quotated including all taxes and duties)
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
technical_2509670.pdf
techsummary_2509670.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
2911_Form.pdf
Tender Documents • 0.50 MB
suspension.pdf
Additional Documents • 2.91 MB
BOQ_2509670.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid