Executive Engineer
Municipal Corporation Una
Repair and Renovation of Municipal Corporation building. SH P.F of Wall Panelling, down Ceiling electrical work in new office of the Executive Engineer and Joint Commissioner under Municipal Corporation Una HP
2026_UDDHP_140820_1
MCU/e-tender/2101 dated 07.08.26
Open Tender
Civil Works
Percentage
Municipal Corporation Una
Please refer Tender documents.
3 documents required · 3 mandatory
₹350
Commissioner
₹14,191
21 Aug 2026
12 Aug 2026
19 Aug 2026
12 Aug 2026
18 Aug 2026
12 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | P/F of Wall panelling in pre laminated board 9 mm thick fitting with aluminium Chanel complete in all respects. | 1 | Sqft | 275 | ₹274.73 |
| 2 | P/F of Down Ceiling with sheets 600x600x6mm thick cardboard, Manufacturing frame under aluminium Chanell Size 20mm x 25mm thick including cutting hole of LED lights complete. | 0.2 | Sqft | 250 | ₹50 |
| 3 | P/F of Roller blinds made using 100% Polyster with necessary fitting complete at site. | 0.04 | Sqft | 230 | ₹9.2 |
| 4 | P/F of Curtains using Cloth with 2.70mtr Length, SS rods Brackets, Wall to wall, Fnnel etc Complete. | - | Nos. | 1,200 | - |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required. Makes: - Anchor / Finolex / Polycab :- 2 X 1.50 sq mm | - | Mtrs. | - | - |
| - | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required. Makes: - Anchor / Finolex / Polycab :- 3 X 2.50 sq mm | - | Mtrs. | 311 | - |
| - | Providing Installation, testing and commissioning of ceiling fan with modular step type electronic fan with remote, including wiring the down rods of standard length (up to 30 cm) with 1.5/2.0 mm twin twisted flexible, cotton braided, copper cable etc., as required.Ceiling Fan: 1200 mm sweep, Usha 3 star/Bajaj 3star/Crompton 3 star. | - | Nos. | 12,000 | - |
| - | Providing and installation exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required. Exhaust Fan: Light duty, (Domestic) 300mm sweep, Usha /Bajaj /Crompton | - | Nos. | 2,567 | - |
| - | Providing and Fixing of LED Ceiling lights of reputed Makes: Havells/ Philips/Panasonic | 16 | Nos. | 4,900 | ₹78,400 |
| - | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps: Cat-A.Makes:- L&T/Legrand/Schneider | 2 | Nos. | 426 | ₹852 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.18 MB
BOQ_208934.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .