4 Nov 2020, 6:00 pmClosed
GE 881 EWS
GE 881 EWS C/o 56 APO
REPAIRS TO AIR CONDITIONER WINDOW/SPLIT TYPE, WATER COOLER, REFRIGERATOR, DEEP FREEZER AND CONNECTED WORKS UNDER THE AOR OF STN HQ POONCH, KG BG UNDER GE 881 EWS
2020_MES_373034_2
GE/PNH-80/2019-20
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹18,000
Yes
8 Feb 2021
17 Oct 2020
5 Nov 2020
17 Oct 2020
4 Nov 2020
18 Oct 2020
Amount
Complete servicing and repair of Split type AC 1.5/2 Ton capacity including taking down of air conditioner, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections and re-fixing in the same position & testing after servicing, complete all as directed by Engr-in-Charge. Note:-Unsv accessories required for repair / replacement of unsv spare parts will be measured and paid seperately under respective items of BoQ.
Supply only the following items required to incorporate in item No 1.00 above:-
Hermalic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Split AC 2.0 T capacity.
Hermalic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Split AC 1.5 T capacity.
Fan/blower electric motor single phase 230 V complete for inner unit.
Fan/blower electric motor single phase 230 V complete for outer unit.
Stratring capacitor of suitable capacity.
Running capacitor of suitable capacity.
Overload protection of suitable capacity.
Drain pipe for Split unit PVC 20mm dia.
Fan blade of suitable size for outer unit.
Remote control kit complete for Split type AC.
Complete servicing and repair of Window type AC 1.5/2 Ton capacity including taking down of air conditioner, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections etc and re-fixing in the same position & testing after servicing, complete all as directed by Engr-in-Charge. Note:-Unsv accessories required for repair / replacement of unsv spare parts will be measured and paid seperately under respective items of BoQ.
Supply only the following items required to incorporate in item No 3.00 above:-
Hermalic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Window AC 2.0 T capacity.
Hermalic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Window AC 1.5 T capacity.
Capacitor of suitable capacity for Window AC 1.5/2 Ton capacity.
Auto cut thermostate of suitable capacity for window AC 1.5/2 ton capacity.
Operload protection for Window type AC 1.5/2 ton capacity.
Grill for window AC of suitable size/shape /model as required at site.
Fan blade of suitable size for window type AC unit.
Fan/blower electric motor single phase 230 V complete.
Complete servicing and repair of Water Cooler any capacity, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections and re-fixing in the same position & testing after servicing, complete all as directed by Engr-in-Charge. Note:-Unsv accessories required for repair / replacement of unsv spare parts will be measured and paid seperately under respective items of BoQ.
Supply only the following items required to incorporate in item No 5.00 above:-
Hermalic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Water cooler 40/80 Ltrs.
Hermalic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Water cooler 60/120 Ltrs.
Fan/blower electric motor single phase 230 V complete for water cooler 40/80 or 60/120 Ltrs capacity water cooler.
Running capacitor of suitable capacity.
Stratring capacitor of suitable capacity.
Auto cut ther mostate switch for water cooler.
Overload protector for water cooler of any capacity.
Fan blade of suitable size.
Push cock/soft closing tap brass chromium plated of size 15 mm.
PVC connection pipe 600 mm long of required dia, both end screwed for water cooler.
Stop cock both end screwed chromium plated suitable for 15mm bore.
Ball valve PVC 15mm size for water cooler 40/80 ltr capacity
Complete servicing and repair of Refrigerator / Deep Freezer of any capacity, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections, and re-fixing in the same position testing after servicing, complete all as directed by Engr-in-Charge. Note:-Unsv accessories required for repair / replacement of unsv spare parts will be measured and paid seperately under respective items of BoQ.
Supply only the following items required to incorporate in item No 7.00 above:-
Hermalic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Refigerator 165 Ltrs capacity.
Hermalic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Refigerator 286/310 Ltrs capacity.
Auto cut thermostate switch for Refrigerator defrosts type upto 310 ltr capacity.
Overload protectors for Regrigerations upto 310 Ltrs capacity.
Copper strainer filter for Reftrigerator upto 310 ltr capacity.
Relays suitable for Refrigerators upto 310 ltr capacity
Supply only door switch for refrigerator any type.
Supply only door spring for refrigerator any type.
Freezer chest door suitable for 286/310 Ltr capacity.
Magnetised door lock rubber strip 'D' type for regrigerator 286/310 Ltr cacpacity.
Evaporator coil assembly 165 ltrs capacity regrigerator with copper pipe.
Evaporator coil assembly 286/310 ltrs capacity regrigerator with copper pipe.
Fan Motor for chiller unit as per existing make.
Supply and filling gas charging required to the System of suitable type F-12, complete all as specified.
Supply and filling gas charging required to the System of suitable type134a, complete all as specified.
S&F in repair base tray of window type AC 1.5/2 Ton capacity unit including the following 1. Removing of compressor condenser, wiring kit, from base tray 2. Fixing of new base having all fittings/fixtures to accommodate all accessories made out of MS sheet 1.6mm thick duly painted. 3. Carrying out the nitrogen pressure for 24 hrs 4. Carrying out the vaccusising and gas charging to unit. Note:-Gas will be measured and paid seperately under respective items of Sch.
S&F in repair base of water cooler of any capacity unit including the following: 1. Removing of compressor condenser, wiring kit, from base tray 2. Fixing of new base having all fittings/fixtures to accommodate all accessories made out of MS sheet 1.6mm thick duly painted. 4. Carrying out the nitrogen pressure for 24 hrs 4. Carrying out the vaccusising and gas charging to unit. Note:-Gas will be measured and paid seperately under respective items of Sch 'A'.
PVC insulated flexible cable 3 core with multistranded copper conductors round shaped sheathed for 1100 volts grade of size 2.5 Sqmm, complete all as specified.
PVC insulated flexible cable 3 core with multistranded copper conductors round shaped sheathed for 1100 volts grade of size 4.00 Sqmm, complete all as specified.
Supply and fix capallary copper tube for window, split, water cooler , refrigerator, complete all as specified.
Taking down of split AC 1.5/2 T capacity from existing location to refixing in another location incluging both inner and outer units (filling up gas if necessary ) including connected accessories in complete all as directed by Engr-in-Charge.
Submain wiring with two single core PVC insulated, unsheathed, stranded copper conductor cable (FRLS), 1100 volts grade of size 6.0 Sqmm (nominal area) each and one single core 4.0 Sqmm (nominal area) as earth continuity conductor drawn into PVC casing capping complete all as specified and directed. NOTE: (i) Rates for PVC casing capping with accessories are deemed to be included in the unit rate. (ii) Two run of 6.0 Sqmm and one run of 4.0 Sqmm copper cable shall be measured as one length.
Plug & Socket Box, with plastic enclosure for surface mouting, 20 Amps MCB SP complete as specified and directed. Make : Havells (DHDMCSN0251020) or equivalent in Legrand /L&T /C&S
Supply & replacement of switch socket combination flush type 5/15 Amps 3/3 pin universal multipurpose, complete as specified and directed.
Supply and replacement of plug top 3 pin 15 amps ISI marked complete all as specified.
NATIONAL TRADING COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .