REPAIR AND MAINT OF E/M INSTALLATIONS DG SETS SECURITY LIGHTS LT OH LINE AT PATTAN GARRISON UNDER AGE (I) CIF (K)
2020_MES_400108_1
AGE(I) CIF (K)-30/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SHALATENG
REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
AGE I CIF K
₹16,000
Yes
16 Feb 2021
3 Dec 2020
9 Jan 2021
9 Dec 2020
7 Jan 2021
24 Dec 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable and foundation of poles, stays and getting out in any type of soil, complete all as specified and directed by the Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 metre wide and depth exceeding 1.5 metre and not exceedig 3 metre for laying of cable and foundation of poles, stays and getting out in any type of soil, complete all as specified and directed by the Engineer-in-Charge.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and as directed by Engineer-in-Charge.
Sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable, complete all as specified and directed by Engineer-in-Charge. Note: Punned thickness of sand shall be measured.
Common burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other for cable protection, complete all as specified and as directed by Engineer-in-Charge..
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150 Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed in service connections , nominal cross section 10 sq mm, 2 core , complete all as specified and directed by Engineer-in-Charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed in service connections , nominal cross section 16 sq mm, 2 core, complete all as specified and directed by Engineer-in-Charge.
Replacement of existing Moulded Case Circuit breaker with new Moulded Case Circuit breaker of Capacity 100 Amps , 25 KA , 04 Pole, 415 V 50 Hz, complete all as specified and directed by the Engineer-in-Charge.
Replacement of existing Moulded Case Circuit breaker with new Moulded Case Circuit breaker of Capacity 125 Amps , 25 KA , 04 Pole, 415 V 50 Hz, complete all as specified and directed by the Engineer-in-Charge.
Replacement of existing Moulded Case Circuit breaker with new Moulded Case Circuit breaker of Capacity 160Amps , 36 KA , 04 Pole, 415 V 50 Hz, complete all as specified and directed by the Engineer-in-Charge.
Replacement of existing Moulded Case Circuit breaker with new Moulded Case Circuit breaker of Capacity 400 Amps , 36 KA , 04 Pole, 415 V 50 Hz, complete all as specified and directed by the Engineer-in-Charge.
Stay assembly using GI stay rod of 16mm dia complete with accessories as shown in Electrical Plate No.1 of SSR 2009 Part I, including dismantling of existing unserviceable stay assembly, complete all as specified and directed by the Engineer-in-Charge. The stay assembly shall comprising of the following:- i) Necessary excavation and earthwork for pit of size 120 x 60 x 120 cm . ii) PCC (1:3:6) as in foundation concrete for stay assembly. iii) Stay rod 16mm dia , 180 cm long. iv) Stay plate of size 23cm x 23cm x 6mm. v) Stay bow. vi) Stay wire GI stranded of size 7/4mm, not exceeding 7.50m with each stay. vii) Stay clamp at top of pole of MS flat of size 50 x 6mm, including two No's of nut and bolts of size 75 x 15mm . viii) Loop type insulator, porcelain, vitreous, white, brown or green, large size of 90 x 140mm, clearance of hole 25mm.
ACSR Conductor for LT lines on steel tubular poles, streching properly without kinks and bends on insulators and binding with aluminium binding wires, jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between span as per IE Rules etc. including taking down old conductor of any type ,shape and size and removing from site, complete all as specified as directed by the Engineer-in-Charge.
Structural steel work as in Cross Arms, bracing ,supports,clamps and back plates fabricated from structural sections incl nuts,bolts,washers,bending hot or cold ,drilling holes for bolts ,in any shape or size as indicated or directed and applying two coats of aluminium paint over one coat of red oxide primer incl preparation of surfaces complete and dismantling old cross arms and removing from site, complete all as specified and directed by Engineer-in-Charge.
Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade, complete all as specified and as directed by Engineer-in-Charge.
Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation of poles/struts, filling and mass concrete including necessary form work, complete all as specified as directed by the Engineer-in-Charge.
Providing and laying plain cement concrete 1:3:6, type C-1, using 20mm graded crushed stone aggregate, as in coping around poles including necessary form work and fair finishing of exposed surfaces without using extra cement , complete all as specified and as directed by the Engineer-in-Charge.
Steel tubular swaged pole erected to truly vertical or planted as strut complete with 6mm thick cast iron/mild steel base plate continuously welded to pole, finial taper plug, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II as specified type 410 SP–31 (09 metre long) including drilling of holes of required size for fixing of cross arms and applying two coats of bituminous paint internally throughout and externally for embedded portion and with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching/coping externally including taking down old existing pole , complete all as specified as directed by the Engineer-in-Charge. Note: Necessary earth work, PCC foundation and coping will be measured and paid for separately under respective items.
Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.30 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 metre below ground levels with top edge of the earth plate not less than 1.50 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron strip, 32 x 6 mm earth lead by means of bolts, nuts check nuts and washers of galvanised steel and GI pipe light grade 20 mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 of MES Schedule 2009 Part-I connected to earthing test point , complete all as specified and directed by the Engineer-in-Charge. Note:- Earthing to be done for replacement of existing earthing. The materials retrieved from earthing shall be credited to contractor.
Supply and fix lugs or thimbles of size 25 Sqmm to 70 sqmm aluminum, complete all as specified and directed by Engineer-in-Charge.
Supply and fix lugs or thimbles of size 95 Sqmm to 185 sqmm aluminum, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement LT Spacers 4 Ways,made out of PVC material and suitable for 4 wire LT overhead line working on 1100 volts, complete all as specified as directed by the Engineer-in-Charge.
Inspection/annalysing of transformer removed from site of capacity 63 to 200KVA and drain out transformer oil complete at site as per the engineering practice, storing the oil in suitable container to be provided by the contractor to keep in safe custody for reuse , lifting of core assembly from its orginal positon for annalysing, if found fault in winding contractor will arrange transportation for work shop for rewinding and inspecting of viscosity of the oil, if found good the same will be refilled , complete all as specified as directed by the Engineer-in-Charge.
Hiring transportation installation and testing of serviceable transformer of existing capacity or higher in place of unserviceable transformer which is under repair and shifting back to workshop on hire basis for 15 days when ordered, complete all as specified and directed by the Engineer-in-Charge. Note:- (i) Repairing of transformer shall not exceed beyond 15 days from the date of dismantling from original site, (ii) Contractor shall not be allowed to shift hired transformer untill it is replaced by orginal one. (iii) Hired transformer will match with the existing transformer with same voltage, vector group, impendence etc. (iv) Incase the defective/unservicable transformer is not repaired with in liabllity period of 15 days a penalty of Rs 1000/- will be deducted and no extra cost willl be paid to the contractor un less natural calamidity is occured,
Rearranging the top lamination over coils in proper manner including fixing to channels, soldering in between coils as necessary and bazing of delta star connection with /without tap changer for transformer of capacity 63 to 200KVA, complete all as specified and directed by the Engineer-in-Charge.
ON load centrifuging and dehydration including filteration and cleaning for transformer oil by dehydration machine electrically operated without any shutdown of transformer includinjg testing oil sample before and after dehydration and filteration oil complete all as specified and directed by the Engineer-in-Charge. Note:- (i) Transformer oil required for top up shall be measured and paid separtely (ii) Contractor shall arrange the dehydration machine and testing kit from his own resourse with out any extra charges,
Filling /toping up of transformer oil in transforemer/ servo stabilizer having dielectric strength not less than 35KVA at 2.5mm gap high voltage as per IS/IEC specification ofl low viscosity, complete all as specified and directed by the Engineer-in-Charge. Note:- Dielectric test will be carried out before filling of oil in transformer.
Servising of Diesel engine Generating sets of capacity 18.5 to 160 KVA rating to be carried out as per schedule given as under :- B- check :-(Every 100 Hrs or 6 months whichever is earlier) (i)Change lubricating oil (ii) change lubricating oil filters (iii)change fuel filters (iv) Change coolant (v)check Engine wiring for damage (vi) Drain fuel supply tank (vii) Change by pass lubricant filters (viii) Change air filters (ix) Check oil pressure (x)Change fuel water seperator. C- Check :-(Every 1500 Hrs or 1 year whichever is earlier) (i) Adjust valves (ii)Steam clean engine (iii) Replace hoses if required (iv) Check turbo charger mounting nuts (v ) Check engine oil heater (vi) clean rediator (vii) Inspect following parts and replace if required (Alternator,starter etc ) (viii)Clean fuel from inside (ix) Change engine oil. Note :(i) B-check and C check spare parts will be measured and paid separately under supply only items of this BOQ. (ii)Fixing charges included with the servicing of DG set.)
Supply only Bye pass lubricant oil filters cartridge elements with 'O' ring for 18.5 to 160 KVA DG set, complete all as specified and as directed by the Engineer-in-Charge. Make:-Kirlosker/cummins/fleetguard
Supply only air filters cartridge elements with 'O' ring for 18.5 to 160 KVA DG set, complete all as specified and as directed by the Engineer-in-Charge. Make:-Kirlosker/cummins/fleetguard
Supply only fuel oil filter cartridge elements with 'O' ring for 18.5 to 63 KVA DG set, complete all as specified and as directed by the Engineer-in-Charge. Make:-Kirlosker/cummins/fleetguard
Supply only lubricant oil filter cartridge elements with 'O' ring for 18.5 to 160 KVA DG set, complete all as specified and as directed by the Engineer-in-Charge. Make:-Kirlosker/cummins/fleetguard
Supply only fuel water separator filters cartridge elements with 'O' ring for 18.5 to 160 KVA DG set , complete all as specified and as directed by the Engineer-in-Charge. Make:-Kirlosker/cummins/fleetguard
Supply only engine oil 15 W 40 grade in DG Set, complete all as specified and as directed by the Engineer-in-Charge. Make: Castrol/ Servo
Supply only Coolant of DG Set, complete all as specified and as directed by the Engineer-in-Charge. Make: Castrol/ Servo
Supply only V-Belt off sizes as per site requirement , complete all as specified and directed by Engineer-in-Charge. Make:- Fenner or equivalent as approved by AGE(I)
Supply only of Oil pressure gauge ISI marked, complete all as specified and as directed by Engineer-in-Charge.
Supply only of Oil temparature gauge ISI marked , complete all as specified and directed by Engineer-in-Charge.
Supply only of Fuel gauge meter ISI marked operated on 24 V DC complete all as specified and directed by Engineer-in-Charge.
Supply only of high temparature diesel hose pipe of 1000 PSI of size 12.5mm dia for connecting from diesel tank outlet to engine ISI marked complete with banjo bolt and washer, complete all as specified and directed by Engineer-in-Charge.
Supply only of high temparature diesel hose pipe of 1250 PSI of size 10.3mm dia for connecting from diesel tank outlet to engine ISI marked complete with banjo bolt & washer, complete all as specified and directed by Engineer-in-Charge.
Supply only of distilled water for battery, complete all as specified and directed by Engineer-in-Charge.
Dismantling of radiator complete from DG Sets cleaning/scraping of depositing manualy from outside of the radiator, cleaning of all copper tubes of radiator with descaling solution from inside and outside with forged feed method and with water and aircompressor (by using separate chemical pump water pump and compressor) plugging of all leakage in welding, brazing of copper tubes, claining of fins and replacement of gaskets etc, for DG sets of capcity up to 166 KVA, complete all as specified and directed by Engineer-in-Charge.
Dismantling of Exhaust pipe of silencer, cleaning of silencer to remove carbon deposit inside exhaust and refixing including replacement of worn out rubber gasket packing and nut, bolts, complete all as specified and directed by Engineer-in-Charge.
Dismantling of defective alternator/ dynamo from engine supplying and fixing new alternator 24 volts DC including replacement of worn out nuts, bolts mounting clamp etc, complete all as specified and directed by Engineer-in-Charge. Make:- TVC Lucas or equivalent as approved by AGE(I)
Taking down unserviceable battery 12V 180 AH from the DG Set and supply and install 12 V 180AH maintenance free battery including terminal clamps, copper lead of suitable size/ length, battery stand complete testing and commissioning , complete all as specified and directed by Engineer-in-Charge. Make : Exide/Luminous/Tata green/ Amar raja
Taking out Diesel Tank of any capacity carefully including disconnection from system, descaling the diesel tank with water pressure and removing the complete deposited, drying the tank and painting two coat with super enmelled paint out side the tank size, replacement of gate valve and fixing the tank in original location and connection with existing diesel line with replacement GI/MS fittiing replacement of diesel indicator glass/PVC tube with necessary fitting,repair to any leakage,cleaning and testing of fuel line upto FIP inlet including making of locking arrangements complete up to 600 Ltrs capacity, complete all as specified and directed by Engineer-in-Charge.
Replacement of battery lead set of two suitable for 180 AH capacity 1.5 mtr long including GM terminals one end coper lug and other and including 0.5 metre connecting both end with gun metal terminals, complete all as specified and directed by Engineer-in-Charge. .
Supply and fixing on load changeover switch Range 100A, 415V, AC 23A, 4P IEC 60947-3, IS/IEC 60947-3 Conforms to Staggered terminals, Site convertible fuse version for open execution Flip-able handle above 400A Interchangeable dual shaft position with site convertibility along with SS enclosure version require separate cable gland box, complete all as specified and directed by Engineer-in-Charge. Make :- L&T cat part no.CO11000OSOO type CO1-100 or other equivalent approved in Havells/Legrand
Supply and fixing on load changeover switch Range 63A, 415V, AC 23A, 4P IEC 60947-3, IS/IEC 60947-3 Conforms to Staggered terminals, Site convertible fuse version for open execution Flip-able handle above 400A Interchangeable dual shaft position with site convertibility along with SS enclosure version require separate cable gland box, complete all as specified and as directed by Engineer-in-Charge. Make :- L&T cat part no.CO11000OSOO type CO1-63 or other equivalent approved in Havells/Legrand
Taking out unserviceable asbetos rope from the exhaust pipe, cleaning the exhaust pipe and supply and wraping new asbetos rope of suitable size and wrapping with wire mesh and plastering with plaster of paris / white cement for smooth finishing including replacment of gasket and tightening of ll nut and bolts, complete all as specified and as directed by Engineer-in-Charge.
New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 LED street light fitting 40/45 watts with heat resistant toughned glass complete with all accessories and making of electrical connection with and including three core flexible copper conductor cable of suitable size, including taking down existing old unserviceable fitting, complete all as specified and as directed by the Engineer-in-Charge. Make:- Havells Cat part No. ENDURAPEARLNEOSL40WLED 757PASYTOPC or equivalent in Phillips/Bajaj/Crompton
Note :- An amount of Rs. 46,050.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S YATTOO CONTRACTORS
M/S B A Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .