Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (E)
6th floor, NW wing, BSNL Bhavan, 5-9-25, Hill Fort Road, Adarsh Nagar, Hyderabad. -500063
Providing Preventive and breakdown Maintenance of DG Sets up to 40 KVA in various TE/Cell BTS Sites under Khammam SSA
2021_BSNL_77762_1
28/BED-I/HYD/2021-22 dated.15 /05/2021
Open Tender
Electrical Works
Item Rate
90 days
Khammam
Please refer Tender documents.
16 documents required · 16 mandatory
₹590
Accounts Officer (Cash), O/o GMTD, BSNL, Nalgonda,
₹10,762
28 May 2021
20 May 2021
28 May 2021
20 May 2021
27 May 2021
20 May 2021
90 days
Amount
General servicing of following capacity EA sets including draining out the existing oil, filling the new Lubricating oil, replacing the filter kits, adjusting the belt tensions, cleaning the EA set and testing on exchange load as reqd.
a) 10/12.5/15 KVA DG sets
b) 20/21.5 KVA DG sets
c) 30/40 KVA DG sets
Replacement of the following components (when found faulty) i/c removing the faulty one and testing after replacement as reqd
a) Normal duty fuel flexible pipe of length approx.
b) Hour meter electronic type
c) RPM /Hour meter Anologue type without cable
d) Cable for RPM meter
e) V- Belts
f) Hoses for radiator
g) Toping up of Lub oil
h) Water Coolant
i) Oil pressure indicating Meter
j) Fuel tank level pipe (Indication)
k) Flexible Bellow pipes in Exhaust Pipe system up to 40 KVA engines.
l) Carbon brushes
m)Rotating Rectifier diodes
o) 10 Sq.mm copper cable
S/F of Automatic Voltage Regulator (AVR) Suitable for Alternator and necessary wiring i/c connections, testing etc, complete as required.
Supplying and fixing of 12 Volts, 10 Amps rating SMPS based battery Charger suitable for 230 Volts, 1-Phas, 50 Hz AC Supply including charging clips etc. complete as required.
Repairing of self starter of EA set upto 40 KVA i/c transportation, reinstallation, testing and commissioning as reqd
Servicing of radiator of E/A set up to 40 KVA by cleaning the radiator core / fins / tubes with chemicals, arresting the water leakages by copper brazing the cracks, and refixing testing on exchange loads etc, complete as required.
Shifting and ITC of trolley mounted E/A set of 12.5/21.5/40 KVA capacity from available exchange to required exchange within Khammam SSA, including toeing , providing earth connections, neutral connections, cable connections, with available wires/cables, etc., as required. ( Up to 100 Kmtrs range))
Attending to break down complaint of EA set including checking, rectifying the minor faults, testing the EA set on exchange load as reqd
stage.html
html • 0.01 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .