| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAccepted-Finance 39 288 THANGAMAPURIPATNAM METTUR DAM 2 METTUR DAM 636 406 | METTUR DAM | SALEM | TAMIL NADU | 636406 | L1 | Accepted-Finance L1 | |
| 2 | L2₹4.7 L+₹25,371.18 (5.65%)Accepted-Finance 2 206 C PONNAGAR METTUR DAM 636 401 SALEM DISTRICT | SALEM | TAMIL NADU | 636401 | L2 | Accepted-Finance L2 |
| Sl No | Description | Qty | Unit | mettursrikrishna enterprises L1 | SARVESWARASAMY AND CO L2 |
|---|---|---|---|---|---|
| 1.00 | Charges for removal of local pressure gauges/ temperature gauges and refixing them after calibration in Turbine & Generator areas. | 50 | Nos | 448 ₹22,400 Lowest | 470 ₹23,500 |
| 2.00 | Charges for removal of pressure/ Vacuum/flow switches and refixing them after calibration in Boiler, Turbine and Generator areas. | 50 | Nos | 448 ₹22,400 Lowest | 470 ₹23,500 |
| 3.00 | Charges for removal of existing transmitters including disconnecting the control cables, removal of clamps and manifold and refixing after calibration in Boiler, Turbine and Generator areas. | 25 | Nos | 448 ₹11,200 Lowest | 470 ₹11,750 |
| 4.00 | Charges for dismantling, cleaning & replacement of gaskets and re-fitting of level switches. | 25 | Nos | 2,237 ₹55,925 Lowest | 2,348 ₹58,700 |
| 5.00 | Charges for removing and refitting of accessories in pneumatic control valves & dampers such as E/P converters, air lock relay, air regulators, positioners and position feedback transmitters sending to lab for testing and receiving the tested instruments from lab. | 54 | Nos | 1,867 ₹1,00,818 Lowest | 1,960 ₹1,05,840 |
| 6.00 | Charges for Replacement of HAD/CAD cylinder (8" Boreand 8 " stroke)which involves following works.i) Removal of existing pneumatic cylinder and its accessories with copper tubings from its location to pocket store.ii) Loading, transporting and unloading of new/serviced pneumatic cylinder from store to field location.iii) Fixing the new/serviced pneumatic cylinder and refixing the accessories such as air regulator, I/P converter with SS tubings. | 2 | Nos | 5,722 ₹11,444 Lowest | 6,000 ₹12,000 |
| 7.00 | Charges for Replacement of burner tilt cylinder(10" Bore and 16 " stroke) which involves following works.i) Removal of existing pneumatic cylinder and its accessories with copper tubings from its location to pocket store.ii) Loading, transporting and unloading of new/serviced pneumatic cylinder from store to field location.iii) Fixing the new/serviced pneumatic cylinder and refixing the accessories such as air regulator, I/P converter with SS tubings. | 2 | Nos | 6,988 ₹13,976 Lowest | 7,337 ₹14,674 |
| 8.00 | Removing the terminal connections, Replacing the broken Terminal Blocks and reconnecting the terminal connections and checking in Various Junction boxes at Boiler and mill area. | 300 | Nos | 48 ₹14,400 Lowest | 51 ₹15,300 |
| 9.00 | Charges for rectification and welding of broken doors in junction boxes. | 5 | Nos | 595 ₹2,975 Lowest | 625 ₹3,125 |
| 10.00 | Charges for opening and cleaning of ½” impulse lines and catch pots in mills, Flue gas, primary and secondary air paths. | 110 | Nos | 400 ₹44,000 Lowest | 420 ₹46,200 |
Tender Value
Refer Docs
EMD Value
₹3,300
Closing Date
15 Sept 2026, 2:00 pmClosed
CHIEF ENGINEER/MTPS-I
CHIEF ENGINEER/MTPS-I
MTPS-I ES Circle CI UnitIII Removal and refixing of Pressure gauges Temperature gauges Switches Transmitters after calibration Replacement of Pneumatic cylinders and gaskets for all level switches Cleaning of impulse lines and catch pots, etc during
2026_EB_699397_1
CE-MTPSI-SE-ES-CI-OT12-26-27
Open Tender
Electrical Works
Works
15 days
MTPS-I/METTURDAM
As per tender specification
4 documents required · 4 mandatory
₹0
₹3,300
Yes
17 Sept 2026
29 Aug 2026
16 Sept 2026
29 Aug 2026
15 Sept 2026
29 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Charges for removal of local pressure gauges/ temperature gauges and refixing them after calibration in Turbine & Generator areas. | 50 | Nos | - | - |
| 2 | Charges for removal of pressure/ Vacuum/flow switches and refixing them after calibration in Boiler, Turbine and Generator areas. | 50 | Nos | - | - |
| 3 | Charges for removal of existing transmitters including disconnecting the control cables, removal of clamps and manifold and refixing after calibration in Boiler, Turbine and Generator areas. | 25 | Nos | - | - |
| 4 | Charges for dismantling, cleaning & replacement of gaskets and re-fitting of level switches. | 25 | Nos | - | - |
| 5 | Charges for removing and refitting of accessories in pneumatic control valves & dampers such as E/P converters, air lock relay, air regulators, positioners and position feedback transmitters sending to lab for testing and receiving the tested instruments from lab. | 54 | Nos | - | - |
| 6 | Charges for Replacement of HAD/CAD cylinder (8" Boreand 8 " stroke)which involves following works.i) Removal of existing pneumatic cylinder and its accessories with copper tubings from its location to pocket store.ii) Loading, transporting and unloading of new/serviced pneumatic cylinder from store to field location.iii) Fixing the new/serviced pneumatic cylinder and refixing the accessories such as air regulator, I/P converter with SS tubings. | 2 | Nos | - | - |
| 7 | Charges for Replacement of burner tilt cylinder(10" Bore and 16 " stroke) which involves following works.i) Removal of existing pneumatic cylinder and its accessories with copper tubings from its location to pocket store.ii) Loading, transporting and unloading of new/serviced pneumatic cylinder from store to field location.iii) Fixing the new/serviced pneumatic cylinder and refixing the accessories such as air regulator, I/P converter with SS tubings. | 2 | Nos | - | - |
| 8 | Removing the terminal connections, Replacing the broken Terminal Blocks and reconnecting the terminal connections and checking in Various Junction boxes at Boiler and mill area. | 300 | Nos | - | - |
| 9 | Charges for rectification and welding of broken doors in junction boxes. | 5 | Nos | - | - |
| 10 | Charges for opening and cleaning of ½” impulse lines and catch pots in mills, Flue gas, primary and secondary air paths. | 110 | Nos | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.78 MB
BOQ_840775.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .