| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.2 LAccepted-AOC CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | ₹3.2 L | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹3.3 LRejected-AOC NOT FOUND | ₹3.3 L | L-2 | Rejected-AOC Other than L-1 |
| Sl No | Description | Qty | Unit | Jai Maa Electrical Works L1 | shiv shanker enterprises L2 |
|---|---|---|---|---|---|
| 1.00 | Deployment of manpower/ tools/ machinery/ plant for Dehydration/ filtration of transformer oil of voltage grade 11/ 0.433 KV of transformers, of various capacities installed at different locations by disconnecting plants electrically for re-circulation of existing transformer oil with trolley mounted filtration plant till dielectric strength achieves to min 60 kV when measured at 2.5 mm electrode gap and the acidity brought within the permissible limit complete all as specified and as directed by Engineer-in-charge. | 450 | LITRE | 12 ₹5,400 | 15 ₹6,750 |
| 1.01Note:- (a) Filtration/ dehydration of transformer oil shall be carried out at the location where transformer is installed with trolley mounted filtration plant having pressure gauge, hour meter, temperature gauge including electric supply arrangement to run the dehydration equipment. Rate quoted against the item shall deemed to be included above aspect. | |||||
| 2.00 | Supply and filling of transformer oil for topping up the level of oil/ new filling, having dielectric strength 40-60 KV during filling after initial filteration, conforming to relevent IS-335 (Transformer oil to be supplied in sealed container) complete all as specified and as directed. | 150 | LITRE | 200 ₹30,000 | 150 ₹22,500 |
| 3.00 | Supply and filling of SF6 gas for 11 KV SF6 circuit breaker (including wastage) of capacity 630 Amp complete all as specified and as directed. | 6 | KG | 2,500 ₹15,000 | 5,000 ₹30,000 |
| 4.00 | M&L for leakage detection for 11 KV RMU SF6 circuit breaker and rectification of the same complete all as specified and as directed. | 1 | EACH JOB | 5,000 ₹5,000 | 9,000 ₹9,000 |
| 5.00 | M&L for taking down existing 11 KV SF6 circuit breaker and Servicing, calibration and testing along with control panel and control wiring protection system and relays by primary and secondary injection system including testing of battery bank/ battery charges/ DC system, rectification of fault if any, cleaning and servicing, greasing, oiling of the parts etc., re-assembling the SF6 breaker after overhauling/ servicing and its testing complete all as specified and directed by Engineer-in-charge. | 1 | EACH JOB | 25,000 ₹25,000 | 5,000 ₹5,000 |
| 6.00 | S&F in replacement of flashed out bushing for SF6 circuit breaker complete all as specified and as directed by Engineer-in-Charge. | 3 | EACH | 6,000 ₹18,000 | 7,500 ₹22,500 |
| 7.00 | Repair & servicing of vacuum system of 11 KV SF6 circuit breaker of make CG Lucy complete all as specified and as directed by Engineer-in-Charge. | 1 | EACH JOB | 6,000 ₹6,000 | 7,500 ₹7,500 |
| 8.00 | M&L for Cutting of Gas chamber, intalling new bushing, TIG welding, reinstalling RMU and testing and commisioning complete all as specified and as directed by Engineer-in-Charge. | 1 | EACH JOB | 9,000 ₹9,000 | 7,500 ₹7,500 |
| 9.00 | Repair of outdoor/ indoor power distribution transformer of capacity upto 500 KVA by disconnecting from HT/ LT sides, draining out complete transformer oil & storing the same in suitable containers (to be arranged by contractor), opening the top cover and lifting up the core assembly carefully to check the condition of transformer winding core re-tanking the same after repair, refilling the transformer oil after dehydration and filteration (new transformer oil, dehydration and filteration to be paid separately) including checking of leakage of transformer body and welding works required for making transformer body leak proof transportation of transformer to and from site to work shop and re-installation the same at any site complete all as specified and as directed by Engineer-in-Charge. | 1 | EACH JOB | 8,000 ₹8,000 | 7,500 ₹7,500 |
Updated dates
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
4 Nov 2025, 6:00 pmClosed
CWE Chandimandir
HQ CWE Chandimandir, PIN-134107
CWE/CHD-106/2025-26 REPAIR AND MAINTENANCE OF 11 KV/0.433 KV STEP DOWN TRANSFORMER ALONG WITH SF 6 CIRCUIT BREAKER AT PCDA OFFICE COMPLEX SECTOR 9A CHANDIGARH UNDER GE CHANDIGARH
2025_MES_733688_1
CWE/CHD-106/2025-26
Open Tender
Electrical and Maintenance Works
180 days
GE Chandigarh
Class E, Cate b(ii)
8 documents required · 8 mandatory
₹300
GE Chandigarh
₹10,000
23 Dec 2025
3 Oct 2025
6 Nov 2025
3 Oct 2025
4 Nov 2025
16 Oct 2025
4 Oct 2025 - 10 Oct 2025
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
Tenderdocuments106.pdf
Tender Documents • 0.61 MB
Additional106.pdf
Additional Documents • 0.41 MB
BOQ_821496.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid