Superintending Engineer, EDC, Hapur
Superintending Engineer, EDC, Hapur
Electrification of Indranagar Colony Garh in area of EDD-Garh
2022_PVVNL_732571_1
64(W)/EDCH/2022-23
Open Tender
Electrical Works
Lump-sum
Hapur
enclosed
3 documents required · 3 mandatory
₹1,180
SE, EDC, Hapur
₹2,400
10 Oct 2022
28 Sept 2022
10 Oct 2022
28 Sept 2022
10 Oct 2022
28 Sept 2022
28 Sept 2022 - 10 Oct 2022
Amount
FOR ELECTRIFICATION OF INDRANAGAR COLONY AND OTHER ASSOCIATED WORK, IN DEPOSIT SCHEME, IN THE JURISDICTION OF EDD-GARHMUKTESHWER, UNDER EDC., HAPUR. (All work will be completed as per Sanctioned estimate)
Carriage of line material (like insulator, channel, clmaps, conductor etc.) from Electricity Store Center, Hapur to site of work with loading and unloading at both ends on Kachha Packka road.
Carriage of PCC Pole 8.5 mtrs. Long from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road.
Safe Loading of New 250KVA transformer at JE, Store/CTR/ESC, Hapur, with the help of Crane.
Carriage of New 250KVA transformer from JE Store/CTR/ESC, Hapur to site of work.
Fabrication, erection and fixing of double pole on PCC Pole 8.5 mtr. long with fixing of M.S. Top & Dropper Channel, M.S. S/S Angle, E-Bracket, 11 KV Pin insulator with Pin, Disc Insulator with Disc fitting as per RESPO Drawing/Norms by providing top and dropper clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts.
Erection & fixing of PCC pole 8.5 mtr. in L.T. Line after digging of suitable pits including fixing of all accessories by providing L.T. Pin Clamp made of M.S. Flat of size 50x6mm & Shackle Insulator of size 90x75 mm & proper size nuts and bolts as per RESPO Drawing/Norms.
Laying, Stringing and final sagging of ACSR Weasl Conductor after binding from Insulator, as per RESPO/Drawing Norms.
Laying of ABC (3x50+1x35+1x16)Sqmm, and completion work properly as per RESPO/Norms
Laying of LT ABC (3x95+1x70+1x16)Sqmm, and completion work properly as per RESPO/Norms
Construction of T/F plinth suitable for 250KVA T/F (size of 2 x 2 x 1.5 mt.) as per drawing, cc work in foundation in ratio 1:4:8 (Cement, Sand & Brick ballast). Ist class brick work in side walls cc ratio of 1:4 (cement & fine sand). 12mm thick plaster in ratio 1:4 (cement & fine sand). The RCC work on top of plinth in ratio 1:2:4 after duly filling of brick ballast inside the plinth & ramming the same, including cost of all material & labour.
Safe Unloading of New 250KVA transformer from vehicle, with the help of crane at LT Sub-Station and installing of the same on Double Pole/Plinth.
Connecting of the Jumper of LT & HT side and fixing all required accessories at Double Pole/Plinth.
Erection & Fixing of Distribution Box on pole by provding 02 Nos. D/B Clamps & proper size nut & bolts.
Providing fixing and fabrication of wire mesh fencing around the T/F plinth upto 5 fit height on top of T/F plinth and suitable for 250KVA T/F Plinth, including cost of all material and labour as per drawing
Earthing of supports with MS earth Rod of (20x2500)mm long including excavation of pit and driving M.S. Rod 3.0 M apart from support and 0.5m below the ground level and connection below the earth electrodes with the help of G.I. wire & earthing lugs as per RESPO Drawing/Norms by providing proper size nuts & bolts.
Grouting & fixing of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:4:8 cement, sand, 40mm brick ballast as per drg. Including back filling, proper ramming etc and fixing tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing as per RESPO Drawing/Norms by providing all grouting material and stay clamp made of M.S. Flat of size 50x6mm with proper size bolts & nuts & loops.
Providing and fixing of LT Piercing connector for size of 120/95 as per RESPO/Norms.
Providing and fixing of Dead End Clamp with Eye Hook, as per RESPO/Norms.
Jumpering work properly as per RESPO/Norms.
ARYAN ENTERPRISES
A.A.ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .