Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 126 JULEDHA SARDHANA SARDHANA MEERUT UTTAR PRADESH 250342 | MEERUT | UTTAR PRADESH | 250342 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹6 L
EMD Value
₹6,000
Closing Date
29 Nov 2021, 12:00 pmClosed
SE
Pallavpuram
REGARDING RUNNING TENDER RUNNING CONTRACT OF MAINTENANCE and REPAIRING HEAD WORK OF 11KV and LT LINES, IN THE AREA OF EDSD-I DAURALA, EDSD-II SARDHANA TOWN, EDSD-III SARDHANA DEHAT IN THE AREA OF EDD-II MEERUT UNDER EDC-2 MEERUT
2021_PVVNL_643205_1
90/EDC-2/MT/2021-22
Open Tender
Electrical Works
Item Wise
90 days
Meerut
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
SE EDC-2
₹6,000
30 Nov 2021
15 Nov 2021
29 Nov 2021
15 Nov 2021
29 Nov 2021
15 Nov 2021
Amount
Cartage of following material from store center Meerut to JE Store including loading & unloading at both ends maximum distance up to 40 Km. :–
A) PCC Pole 8.5 mtr. Long/ST Pole 11 mtr. Long.
B) Line materials such as 33KV/11KV Cross arms, 33KV/11KV Pin, 11KV pin Insulator, 11 KV Disc, Stay rod, Stay wire, ACSR weasel/rabbit/Dog Conductor, GI wire etc.
Cartage of following material from JE store to Site of work Including loading & unloading at both ends maximum distance up to 40 km.:- A) PCC Pole 8.5 mtr. Long/ST Pole 11 mtr. Long.
B) Line materials such as 33KV/11KV Cross arms, 33KV/11KV Pin, 11KV pin Insulator, 11 KV Disc, Stay rod, Stay wire, ACSR weasel/rabbit/Dog Conductor, GI wire etc.
Opening the bindings and removal the conductor including all 11KV/LT line Samagri of damaged broken pole.
Removal and damaged broken PCC/ST pole of 11KV/LT line by digging the pit for required size and depth.
Erection of PCC/ST pole from where damaged pole has been removed after digging a pit for required size and depth 1.6 mtr. in all type of Soil incluiding back filling of the pole with proper ramming after completion of work.
Fabrication and fixing of all 11 KV/33 KV line accessories.
Dismentling of damage section pole including removal of accessories.
Dismentling of damage double pole including removal of accessories & T/F.
Erection of Section pole of PCC/ST Pole from where damaged pole has been removed after digging a pit for size required size and depth 1.6 mtr. in all type of Soil including back filling of the pole with proper ramming after completion of work.
Fabrication and fixing of all 11 KV/33 KV line accessories.
Erection of Double Pole of PCC Pole from where damaged pole has been removed after digging a pit for size required size and depth 1.6 mtr. in all type of Soil including back filling of the pole with proper ramming after completion of work.
Fabrication and fixing of all 11 KV/33 KV line accessories of Double pole.
Mounting of 25 KV to 100 KVA T/F on double pole including making the jumpers of HT side and fixing the cable of LT side.
Erection of Stay rod completion after digging a pit of size 1.20x0.60x1.6 mtr. And grouting the same in block of size 0.60x0.60x0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming.
Laying Lifting stringing of proper sagging of ACSR weasel conductor after jointing the new conductor/repairing the existing conductor for 3 phase, 3 wire 11KV line including binding & jumpering properly.
Laying Lifting stringing of proper sagging of ACSR weasel conductor after jointing the new conductor/repairing the existing conductor of LT ine including binding & jumpering properly.
Replacement of damaged 11 KV MS cross arm with new cross arm by opening the bindings and nut bolts of clamps then rebinding the same after completion of work.
Replacement of damaged and cracked 11 KV disc insulator by opening the jumper and rejumpering the same after completion of work.
Replacement of damaged 11 KV Pin insulator by opening the binding and rebinding the same after completion of work.
Straightening of titled PCC Pole after opening the binding and digging the pit for required depth and refilling the same and rebinding after completion of work.
Resagging of loos sag of 11KV & LT line after opning the binding and strainging the conductor then rebinding jumpering the same after completion of work.
Cutting & chopping tree branches near side of line for making the clearance between line and tree.
Straightening of bended cross arm of 11 KV line after opening the nut bolts and binding from insulator.
Providing & fixing Holding Clamps.
Providing & fixing F Clamps.
Providing & fixing LT Clamps.
Providing & fixing LT Insulator
Providing & fixing Stay Clamps.
Providing & fixing Stay Insulator
Providing & fixing Bolt & nuts.
M/S MOHAMMAD ABBAS
M/S DHARAM DASS & BUDH PRAKASH & CO.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .