Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹10.2 LAccepted-AOC CHANDRAPUR | CHANDRAPUR | CHANDRAPUR | MAHARASHTRA | 442905 | L-1 | Accepted-AOC Techno commercially eligible L-1 Bidder |
Tender Value
₹15.9 L
EMD Value
₹19,900
Closing Date
24 Oct 2022, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer (E and M)
AGM Office, Majri Area, Post. Shivaji Nagar, Teh. Bhadrawati, Dist. Chandrapur, Maharashtra, 442503
Diversion of 11 kV Kuchana Feeder passing through NMUG to OC mine, Majri Area
2022_WCL_258712_1
ma9511-enm-047-2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Majri
Please refer NIT documents
2 documents required · 2 mandatory
₹19,900
7 Jan 2023
8 Oct 2022
25 Oct 2022
8 Oct 2022
24 Oct 2022
10 Oct 2022
8 Oct 2022 - 15 Oct 2022
Amount
Erecting rolled steel joist (girder) pole 200 x100 mm. (25.9 kg/m) with provided base plate in provided foundation as per specification no. OH-PL/RSJ CSR No. 8-1-10
Making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles) CSR No. 16-3-4
Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.l. stay rod 20 mm x 1.8 m length and pole clamps duly erected in provided cement concrete foundation.CSR No. 8-7-2
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay). CSR No. 16-3-6
Supplying and erecting vee cross arm with ISM channel of 75x40x6mm, for 11kV HTOH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220 mm bent at angle of 60 degree keeping base 305 mm and the total vertical height of V cross arm as 460mm, and fixed on pole with MS clamp of 80x10 mm, nut bolts,washers complete as per specification no. OH-PL/VCACSR No. 8-4-12
Supplying and erecting 75x40x6 mm with 4.4 mm thick web and 7.3 mm thick flange channel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065 mm for 11 kV,1320 mm for 22 kV between insulators for erection of top pin insulators complete as per specification no. OH-PL/VCA CSR No. 8-4-14
Supplying and erecting bracket for guarding of HT OH Line, made from channel iron 1600 mm in length and 75x40x6 mm. erected on pole complete as per specification no. OH-PL/VCA. CSR No. 8-4-15
Supplying & erecting 100 x 50x6 mm with 4.7 mm thick web and 7.5 mm thick flange channel iron cross arm of suitable length for 2.4m wide DP structure and erecting on DP with 50x6 mm clamp as per approved method of construction and complete as per \specification no. OH-PL/BKT. CSR No. 8-4-11
Supplying and erecting pole clamp made from 50 x 6 mm MS flat for pole or pipe, post complete erected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. CSR No. 8-7-10
Supplying and erecting porcelain disc type insulator with necessary hardware suitable for 11kV line, complete as per specification no. OH-INS/DICSR No. 8-6-6
Supplying and erecting porcelain pin type insulator with G.I. pin suitable for 11kV line, complete as per specification no. OHINS/ PNCSR No. 8-6-9
Erecting ACSR conductor of size - 6/1-4.72 mm (Dog) complete. (394 kg/km) as per specification no. OHCON/ ACSR CSR No. 8-5-11
Supplying and erecting ACSR conductor of size 6/1-3.66 mm complete.(Mink) (255 kg/km) as per specification no. OHCON/ACS. CSR No. 8-5-9
Erecting approved make 11 kV outdoor type gang operated air break, triple pole switch 400 A capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of "C" class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp.CSR No. 10-2-2
Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.CSR No. 9-2-5
Supplying and erecting guarding lace for H.T.O.H. line with 8 SWG G.I. wire to protect the H.T. overhead line with binding wire of 20 SWG G.I. wire for 75 mm section on either side.CSR No. 8-7-18
Supplying , erecting & terminating 3 x 70 sq. mm. aluminium 11 kV(E), XLPE armoured cable on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification no. CBHTCSR No. 7-3-1
Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HTCSR No. 7-5-5
Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EAEP. CSR No. 9-1-4
Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. CSR No. 6-1-19
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). CSR No. 16-3-7
Painting of steel tubular / rail / RSJ pole above 6.0 m length along with street light pole brackets, clamps etc by scrapping the existing paint complete. Specification no CW -PTG/PTP. CSR No. 16-4-3
Painting identification number by indelible ink marker / enamel paint on fittings / equipment with the help of ladders if necessary by dismantling and refitting the enclosures, tubes etc if required the same and refitting complete. CSR No. 16-4-14
Supplying and erecting ant climbing devices, fabricated from pole clamps of MS flat 40x5 mm, with drooping spikes 15 cm. in length, welded to it and erected on pole complete.CSR No. 10-2-17
Dismantling the existing overhead line including G.I. wires of all sizes without damaging & making the coils in suitable sizes. CSR No. 8-8-3
Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. CSR No. 8-8-2
Tree branches cutting
Transporting of pole loading and unloading of Area Workshop to UG to OC Mine and dismantling pole shift to Area Workshop.
Total impact of GST for the purpose of CTC
stage.html
html • 0.03 MB
techsummary_267543.pdf
PDF • 0.19 MB
finsummary_267543.pdf
PDF • 0.19 MB
LOA047of22-23.pdf
PDF • 0.35 MB
finance_267543.pdf
PDF • 0.19 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .