| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 CrAccepted-AOC | ₹2.4 Cr | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹2.4 Cr+₹38,335 (0.16%)Rejected-Finance 01 CHANGSARI KAMRUP ASSAM 781101 | KAMRUP | ASSAM | 781101 | ₹2.4 Cr+₹38,335 (0.16%) | L2 | Rejected-Finance NOT THE LOWEST BIDDER |
| 3 | L3₹2.5 Cr+₹6.7 L (2.75%)Rejected-Finance AT ROAD MES TINALI PO CHABUA DISTT DIBRUGARH ASSAM 84 | CHABUA | DIBRUGARH | ASSAM | 786102 | ₹2.5 Cr+₹6.7 L (2.75%) | L3 | Rejected-Finance NOT THE LOWEST BIDDER |
| 4 | L4₹2.5 Cr+₹9.7 L (4.00%)Rejected-Finance | ₹2.5 Cr+₹9.7 L (4.00%) | L4 | Rejected-Finance NOT THE LOWEST BIDDER |
| 5 | L5₹2.6 Cr+₹14.5 L (5.99%)Rejected-Finance 439 D DEFENCE COLONY JAJMAU KANPUR 208010 | KANPUR NAGAR | UTTAR PRADESH | 208010 | ₹2.6 Cr+₹14.5 L (5.99%) | L5 | Rejected-Finance NOT THE LOWEST BIDDER |
| Sl No | Description | Qty | Unit | M/S R G Construction L3 | Anand Construction L5 | M/s Singh enterprises L7 | ASTRA INFRACON L6 | CHETIA CONSTRUCTION L4 | M/s SRI RAM SWARUP YADAV L1 | M/S A K ENTERPRISE L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Total amount of Sch 'A' Part-I Building Works Note :- This schedule is not pre-priced by MES and the rate indicated as "Rs. 0.00" under column 6 signifies this fact only. | ||||||||||
| 2.00 | Design, Fabrication and Construction of OTM ACCN FOR OR in RCC Framed Structure as per Arch Drg No. CWE/DIN/15/25 sheet No. 1/3 to 3/3 dated 20.01.2025 AND CWE/DIN/15/25 sheet No. 1/1 dated 20.01.2025 and revised thereof. Specification given in Sch A Notes and Particular Specifications including complete RCC foundation and plinth, Flooring, Joinery and Finishes complete all as specified. NOTE : Soil investigation report is attached in tender document for refering during design.
(i) Size – As per Arch drawing (ii) Height – as per Drg
(iii) Fdn – To be design as per SBC report with RCC framed construction. (iv) Plinth – Burnt Brick wk in CM 1:6
(v) DPC – 40 mm thick PCC 1:2:4 with WPC
(vi) Super Structure – All RCC structure to be M25 design mix burnt brick wk wall upto ceiling.
(vii) Seismic Zone – Strengthening measures for Zone V
(viii) Roof – 0.50mm thick Pre-painted Galvalume sheet with MS steel frame structure on living area, roof slab with roof treatment - 150 mm thick on ground floor roof verandhah & Bathroom. (ix) Ceiling : False ceiling with powder coated snap grid frame work.
(ix) Internal Plaster – Internal 15 mm thick in CM (1:6)
(x) Mirror polished kota stone on, verandah & non skid ceramic tiles in toilet and bathroom over 15 mm thick screed bed in base of CM 1:6 over a layer of PCC 1:2:4 over sub base of 1:5:10.
(xi) Dado/Skirting – Glazed ceramic tiles over 10 mm thick cement screed in CM (1:3) up to lintel height.
(xii) Joinery – Frames – pressed steel, shutter – Factory made flush door shutter (TD Drg No CESZ/2015/TD/03 Sheet 1/2 & 2/2) & molded / WPC doors in toilet bathroom
(xiii) Joinery Window – aluminum powder coated window with Guard bars/grill (TD Drg No CESZ/2015/TD/07 Sheet No 1R/5, 2R/5, 3R/5, 4R/5 & 5R/5)
(xiv) Stainless steel routing on first floor of verandah & staircase.
(xv) Iron monger – Prefabricated aluminum anodized fittings. (TD Drg No CESZ/2015/TD/03 Sheet 1/2 & 2/2)
(xvi) Plinth Protection – 75 mm thick PCC 1:3:6 over stone hard core. (xvii) Painting – Synthetic enamel paint on steel/wooden surface.
(xviii) Finishes – Internal - 02 coats of oil emulsion distemper incl 1mm thick wall care putty over a coat of primer. External - 02 Coats of weather proof exterior emulsion over one coat of primer. (xix) Antitermite treatment - As per IS-6313 Part-II : 2001 (xx) Mosquito proofing - All external doors & Windows (xxi) 18mm thick granite over CM 1:3 for steps
(xxii) Sanitory Fitting – Vitreous China EWC, WHB ect of approved make including plumbing work (TD Drg No CESZ/TD-38 Sheet No 1/2 & 2/2 and TD Drg No CESZ/TD-31 Sheet No 1/2 & 2/2).
(xxiii) Mosquito Proofing – All external Door and window.
(xxiv) Green marbles on steps & raiser on staircase. | 1 | LUMP SUM | 1,87,50,000 ₹1,87,50,000 Lowest | 2,04,70,358 ₹2,04,70,358 | 2,35,00,000 ₹2,35,00,000 | 2,25,00,000 ₹2,25,00,000 | 2,01,00,000 ₹2,01,00,000 | 1,95,00,000 ₹1,95,00,000 | 1,90,00,000 ₹1,90,00,000 |
| 3.00NOTE: Schedule ‘A’ Part II to VIII are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured. | ||||||||||
| 4.00 | Total amount of Sch ‘A’ Part II (Site Clearance, Site Development & Earthworks) | 1 | LUMP SUM | 3,16,564.5 ₹3,16,564.5 Lowest | 3,17,000 ₹3,17,000 | 4,00,000 ₹4,00,000 | 3,90,918.93 ₹3,90,918.93 | 4,20,000 ₹4,20,000 | 4,00,000 ₹4,00,000 | 3,17,913 ₹3,17,913 |
| 5.00 | Total amount of Sch ‘A’ Part III (Refrigeration and water cooler) | 1 | LUMP SUM | 65,000 ₹65,000 | 41,200 ₹41,200 | 50,000 ₹50,000 | 56,500 ₹56,500 | 48,500 ₹48,500 | 51,000 ₹51,000 | 40,000 ₹40,000 Lowest |
| 6.00 | Total amount of Sch ‘A’ Part IV (Hot Water Supply) | 1 | LUMP SUM | 3,65,104 ₹3,65,104 | 3,41,500 ₹3,41,500 | 2,50,000 ₹2,50,000 | 2,59,992 ₹2,59,992 | 3,00,000 ₹3,00,000 | 1,60,000 ₹1,60,000 Lowest | 3,45,850 ₹3,45,850 |
| 7.00 | Total amount of Sch ‘A’ Part V (Road/Path/Culvert) | 1 | LUMP SUM | 24,62,987 ₹24,62,987 | 22,20,050 ₹22,20,050 | 30,00,000 ₹30,00,000 | 30,20,000 ₹30,20,000 | 22,00,000 ₹22,00,000 | 20,00,000 ₹20,00,000 Lowest | 23,33,248 ₹23,33,248 |
| 8.00 | Total amount of Sch ‘A’ Part VI (Area Drainage) | 1 | LUMP SUM | 12,71,473.93 ₹12,71,473.93 | 10,50,000 ₹10,50,000 | 17,50,000 ₹17,50,000 | 16,35,329 ₹16,35,329 | 9,20,000 ₹9,20,000 | 7,00,000 ₹7,00,000 Lowest | 10,72,290 ₹10,72,290 |
| 9.00 | Total amount of Sch ‘A’ Part VII (External Water Supply) | 1 | LUMP SUM | 62,840 ₹62,840 | 1,10,000 ₹1,10,000 | 60,000 ₹60,000 | 56,686 ₹56,686 Lowest | 62,000 ₹62,000 | 60,000 ₹60,000 | 99,200 ₹99,200 |
| 10.00 | Total amount of Sch ‘A’ Part VIII (External Electrification) | 1 | LUMP SUM | 5,66,000 ₹5,66,000 | 4,10,050 ₹4,10,050 | 5,00,000 ₹5,00,000 | 4,59,935 ₹4,59,935 | 4,50,000 ₹4,50,000 | 3,60,000 ₹3,60,000 Lowest | 3,85,894 ₹3,85,894 |
Tender Value
₹2.8 Cr
EMD Value
₹3.5 L
Closing Date
30 Oct 2025, 6:00 pmClosed
CWE DINJAN
COMMANDER WORKS ENGINEER DINJAN
PROVN OF OTM ACCN FOR OR OF HQ MTN BDE AT LAIPULI UNDER GE DINJAN
2025_MES_733618_1
84517/E8
Open Tender
Civil Works
Lump-sum
365 days
GE DINJAN
AS PER TENDER DETAILS
8 documents required · 8 mandatory
₹2,000
GE DINJAN
₹3.5 L
Yes
4 Feb 2026
3 Oct 2025
6 Nov 2025
3 Oct 2025
30 Oct 2025
25 Oct 2025
Amount
Total amount of Sch 'A' Part-I Building Works Note :- This schedule is not pre-priced by MES and the rate indicated as "Rs. 0.00" under column 6 signifies this fact only.
Design, Fabrication and Construction of OTM ACCN FOR OR in RCC Framed Structure as per Arch Drg No. CWE/DIN/15/25 sheet No. 1/3 to 3/3 dated 20.01.2025 AND CWE/DIN/15/25 sheet No. 1/1 dated 20.01.2025 and revised thereof. Specification given in Sch A Notes and Particular Specifications including complete RCC foundation and plinth, Flooring, Joinery and Finishes complete all as specified. NOTE : Soil investigation report is attached in tender document for refering during design. (i) Size – As per Arch drawing (ii) Height – as per Drg (iii) Fdn – To be design as per SBC report with RCC framed construction. (iv) Plinth – Burnt Brick wk in CM 1:6 (v) DPC – 40 mm thick PCC 1:2:4 with WPC (vi) Super Structure – All RCC structure to be M25 design mix burnt brick wk wall upto ceiling. (vii) Seismic Zone – Strengthening measures for Zone V (viii) Roof – 0.50mm thick Pre-painted Galvalume sheet with MS steel frame structure on living area, roof slab with roof treatment - 150 mm thick on ground floor roof verandhah & Bathroom. (ix) Ceiling : False ceiling with powder coated snap grid frame work. (ix) Internal Plaster – Internal 15 mm thick in CM (1:6) (x) Mirror polished kota stone on, verandah & non skid ceramic tiles in toilet and bathroom over 15 mm thick screed bed in base of CM 1:6 over a layer of PCC 1:2:4 over sub base of 1:5:10. (xi) Dado/Skirting – Glazed ceramic tiles over 10 mm thick cement screed in CM (1:3) up to lintel height. (xii) Joinery – Frames – pressed steel, shutter – Factory made flush door shutter (TD Drg No CESZ/2015/TD/03 Sheet 1/2 & 2/2) & molded / WPC doors in toilet bathroom (xiii) Joinery Window – aluminum powder coated window with Guard bars/grill (TD Drg No CESZ/2015/TD/07 Sheet No 1R/5, 2R/5, 3R/5, 4R/5 & 5R/5) (xiv) Stainless steel routing on first floor of verandah & staircase. (xv) Iron monger – Prefabricated aluminum anodized fittings. (TD Drg No CESZ/2015/TD/03 Sheet 1/2 & 2/2) (xvi) Plinth Protection – 75 mm thick PCC 1:3:6 over stone hard core. (xvii) Painting – Synthetic enamel paint on steel/wooden surface. (xviii) Finishes – Internal - 02 coats of oil emulsion distemper incl 1mm thick wall care putty over a coat of primer. External - 02 Coats of weather proof exterior emulsion over one coat of primer. (xix) Antitermite treatment - As per IS-6313 Part-II : 2001 (xx) Mosquito proofing - All external doors & Windows (xxi) 18mm thick granite over CM 1:3 for steps (xxii) Sanitory Fitting – Vitreous China EWC, WHB ect of approved make including plumbing work (TD Drg No CESZ/TD-38 Sheet No 1/2 & 2/2 and TD Drg No CESZ/TD-31 Sheet No 1/2 & 2/2). (xxiii) Mosquito Proofing – All external Door and window. (xxiv) Green marbles on steps & raiser on staircase.
NOTE: Schedule ‘A’ Part II to VIII are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured.
Total amount of Sch ‘A’ Part II (Site Clearance, Site Development & Earthworks)
Total amount of Sch ‘A’ Part III (Refrigeration and water cooler)
Total amount of Sch ‘A’ Part IV (Hot Water Supply)
Total amount of Sch ‘A’ Part V (Road/Path/Culvert)
Total amount of Sch ‘A’ Part VI (Area Drainage)
Total amount of Sch ‘A’ Part VII (External Water Supply)
Total amount of Sch ‘A’ Part VIII (External Electrification)
SCH 'A PART IX (Miscellaneous B/R and E/M works) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only
Bringing approved earth (as approved by Garrison Engineer) from sources outside defence land including all costs such as royalty if any transportation taxes etc. for area filling/forming including raising earth spreading in layers not exc 30 cm thick each layer, watering, compaction with 8 tonne to 12 tonne power roller and finished to required size and shape etc, any high /depth from EGL Notes: (i) Earth required for the item shall be suppied by contractor out side MOD land of any lead at his own arrangement. (ii) All cost of procurement of earth including cost of transportation, compaction, royalties, tax etc. shall be deemed to be included in the unit rate quoted by the contractor (iii) with reference to clause 3.6 of MES schedule Part-II on serial page no-21 it is clarified that measurement of the above item shall be finished embankment/traverse of filled earth after consilidation/copmaction and 5% deduction shall be made from measured and calculeted volume to allow for increase in bulk. (iv) Total quantity/ partial of earth may not be available in Dinjan area. The contractor shall bring the earth outside area it is advised to quoted the rate considering availability of soil and its lead involved
S&F new PVC cable Junction Box IP66 "halogen free and weather proof" for out door installation size not less than 200 x 150 x 100 mm suitable for street light incoming and outgoing cables up to 10 to 25 sqmm 4 core (with terminal) & inclusive of MCB SP 10 Amp, 60A 04 strip aluminium Bus Bar, including nuts,bolts,cable glands & MS clamps fixed to pole all as directed.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire unarmoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade passed throuh PVC conduit medium grade of size Min 20mm complete all as specified and directed.
Supply, install, testing and commissioning outdoor type LT outdoor panel of size 1.2m x 1.2m x 0.6m having IP 65 rating, factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having magnetic locking arrangement in both front and rear door painted with powder coated paint and Aluminium bus bar 200 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system , including gland packing/bushes for entry/exit of cable from panel and comprising with and including following accesories and mounted on PCC platform all around the panel board complete with the following items:- (Note : Foundation to be included in the quoted price) Incoming :- (a) MCCB, 4 Pole, 100-125A 415 V 36 kA - 01 no With thermal and magnetic release Outgoing :- (a) MCCB, 4 Pole, 63-100A 415 V 36 kA - 02 nos With thermal and magnetic release (b) MCB,TPN, 63A, 420 V, 18 kA - 03 Nos. (c) Phase indicator lamps (RYB) -set of 3 (d) Aluminium bus bar 4 strip - 200 amps (Length should not be less than 0.8m) (e) Internal connection by Aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etc
M&L for horizantal boring/drilling hole mannual under the road in soft/loose soil without cutting/disturbing the existing road and inserting GI pipe 80/50/40/32mm bore for drawing the cables complete all as directed and specified. (Note: (i) Cost of acessories required for making hole/bore deemed to be included in the quoted rate. (ii) GI pipe has been measured and paid separately)
S&F RCC cable route indicator with embrossing mark as LT cable, of size 75 cm x 15cm x 7.5cm complete all as specified and directed.
M&L for Cutting the existing 100mm dia DI pipe line and inserting Tee 100x100x50 mm dia with collars all as specified and as directed.
M&L for brick masonry valve chamber of size 1000 x 1000 x 1000mm (internal dimensions) with 23 cm thick wall in CM 1:6 including excavation, earth work in any strata & PCC 1:4:8 foundation type D-2, 75 mm thick including 20 mm thick PCC 1:2:4 type B1 in & plastering the internal surface with 10 mm thick cement mortar 1:4 providing 3.15 mm MS sheet chamber cover double opening arrangement center lock system with40x40x6mm angle iron frame duly painted with two coat of black bituminous paint over one coat of red oxide primer complete all as specified and directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc all as specified and as directed.
Supply, Installation, testing and commissioning of 60W All-In-One LED Solar Streetlights made up of Aluminum Extrusion housing with high efficiency Monocrystalline Panel fixed on the top side of luminaire housing (Battery, charge controller and LED module should be integrated inside Luminaire). Maintenance free 12.8V/60Ah LiFePo4 battery along with BMS (BIS certification required) with minimum cycle life of 2000 cycles, MPPT Charge controller with Efficiency > 90%. Luminaire should be IP65 & IK08 and have lumen output of greater than 8000 lumens at full power (System Efficacy > 150 Lumens/watt) as LM79 from NABL accredited Lab. The LED chip used should be of Osram, Lumileds, Cree, nischia only with CRI>70 and CCT – 5700K +/- 500K and should be with lenses for effective light distribution. Luminaire must have Green & Red indicator lights for showing charging of battery and low battery voltage respectively. Light fixture must also have protections like Over-Charge protection, Deep-discharge protection, current protection, Short circuit protection, Over voltage protection. The light fixture should come with a PIR sensor for auto dimming of light fixture based on movement and Complete system should be designed to provide 2 days (24 hours) backup in dimming mode. The light fixture should also come with hybrid controller so that light fixture works on AC power if the battery goes down in case of adverse weather conditions. The solar lighting companies must have toll free base service network to provide immediate after sales service networks available in different districts of the state. Certificates to be submitted – LM79 ,LM80,BIS certificate of Battery ,BIS certificate of Solar Panel,IK08 and IP65 certificate
Supply, fixing, installation & testing of monoblock pump of capacity 2 HP single phase suitable for pipe 50 X 50 mm having head range 12-21 m & discharge range 430 – 250 LPM complete all as specified and directed. Note : 1. Foundation for fixing the monoblock pump shall be included in the quoted price to ensure proper installation and stable operation. 2. Galvanised sheet shed of size 1 m × 1 m × 1 m shall be included in the quoted price for providing adequate protection to the motor.
M/S A K ENTERPRISE (BID ID -3498482)
M/S R G Construction (BID ID -3498489)
CHETIA CONSTRUCTION (BID ID -3498235)
Anand Construction (BID ID -3498538)
ASTRA INFRACON (BID ID -3508109)
M/s Singh enterprises (BID ID -3508147)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.22 MB
BOQ_821473.xls
BOQ • 0.32 MB
TenderDocument.pdf
Tender Documents • 1.40 MB
Drgs.pdf
Additional Documents • 2.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .