Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAdmitted-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON W MUMBAI 400 104 | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹9.9 L | L1 | Admitted-Finance |
| 2 | L2₹10.0 LAdmitted-Finance | ₹10.0 L | L2 | Admitted-Finance |
| 3 | L3₹12.1 LAdmitted-Finance SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | ₹12.1 L | L3 | Admitted-Finance |
| 4 | L4₹12.6 LAdmitted-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | ₹12.6 L | L4 | Admitted-Finance |
| 5 | Rejected-Technical SWAGAT CO OP HSG SOCIETY LTD 22 303 CHATRAPATI SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKTA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | - | - | Rejected-Technical DD not uploaded in favour of GE (NW) Bhandup. |
| Sl No | Description | Qty | Unit | Shree Ayyappa Engineering L1 | sapana enterprises L4 | pk Enterprises L3 | PAUL REFRIGERATION L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Quarterly maintenance of water coolers of any make installed at Naval Depot Area Ghatkopar to check water quality, preventive and breakdown maintenance, lubrication, power supply, repair and replacement of filter candles time to time and the water cooler under contract will be serviced for times during the contract time as per standard checklist, compressor will be checked for its proper functioning. All breakdown calls will be attended to during the contract period.The Blower motor will be checked,the driver set of the blower section wll be inspected but tension adjusted and belts changed. Any defects in the electrical item and control wiring will be attended during contract period. Cost of spare parts/consumeables required shall be borne as per type of contract and shall be applicable to all activities specified under contract etc complete all as specified and directed. | 49 | Each | 4,580 ₹2.2 L | 7,850 ₹3.8 L | 5,025 ₹2.5 L | 4,800 ₹2.4 L |
| 2.00 | Dismantling of existing defective unserviceable compressor of any capacity from window or split AC, Refrigerators, water coolers etc complete all as specified and directed. | 20 | Each | 177 ₹3,540 | 657 ₹13,140 | 654 ₹13,080 | 120 ₹2,400 |
| 3.00 | Supply & Fix in repair new hermetically sealed compresor in split type AC, 1.5/2.0 Ton capacity including initial filling of refrigerant gas to the required pressure, brazing, electric/piping connection etc complete all as specified and directed. | 20 | Each | 10,500 ₹2.1 L | 12,546 ₹2.5 L | 11,425 ₹2.3 L | 9,500 ₹1.9 L |
| 4.00 | Supply & Fix new hermetically sealed compresor in Water Cooler any make 80 Litres capacity. | 10 | Each | 4,000 ₹40,000 | 6,548 ₹65,480 | 4,465 ₹44,650 | 4,000 ₹40,000 |
| 5.00 | Supply & Fix new hermetically sealed compresor in Water Cooler any Make 80/120 Litres capacity and 60/120 Litres capacity.
Note:
(i) The Contractor shall submit original purchase voucher alongwith manufacturer's test certificate and Guarantee Card etc.
(ii) The quoted rates shall also be deeed to include to undertake Guarantee of one year from certified date of completion by the contractor for free replacement of compressor and/or rectification of the same (including charging of gas) all as directed in case any defects are noticed (during Guarantee Period of 01 year) due to any reasons whatsoever may be. | 5 | Job | 4,952 ₹24,760 | 1,548 ₹7,740 | 5,465 ₹27,325 | 5,300 ₹26,500 |
| 6.00 | Taking out split type air conditioner (both indoor and outdoor units) of capacity upto 2 TR of any make/type after disconnecting refrigerant pipes, drain pipe and electric connection and removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda, checking and replacing the spares like relay, capacitors, thermostat, fan motor, blades & blower and including servicing, overhauling and connecting of refrigerant pipe,drain pipe and charging of refrigerant and testing including fixing back in its original location complete all as specified and directed.
Note:
(i) Spares will be measured and paid separately as supply only.
(ii) Refrigerant gas will be measured and paid separately as supply only. | 75 | Each Job | 1,000 ₹75,000 | 980 ₹73,500 | 326 ₹24,450 | 1,100 ₹82,500 |
| 7.00 | Replacement of fan blades of motor for water cooler upto 120 Ltr capacity including testing etc complete all as specified and directed | 30 | Job | 365 ₹10,950 | 980 ₹29,400 | 487 ₹14,610 | 300 ₹9,000 |
| 8.00 | Replacement of fan motor of water cooler up to 120 Ltr capacity including testing etc complete all as specified and directed. | 30 | Job | 740 ₹22,200 | 818 ₹24,540 | 848 ₹25,440 | 600 ₹18,000 |
| 9.00 | Supply only running capacitor of 36/45 MFD complete all as specified and directed. | 30 | Each | 280 ₹8,400 | 325 ₹9,750 | 308 ₹9,240 | 250 ₹7,500 |
| 10.00 | Supply only refrigerent (R-32) gas for top up etc. complete all as specified and directed | 20 | Kg. | 740 ₹14,800 | 818 ₹16,360 | 654 ₹13,080 | 400 ₹8,000 |
Updated dates
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
30 Apr 2026, 6:00 pmClosed
GE (NW) BHANDUP
GE (NW) BHANDUP
REPAIR REPLACEMENT OF SUMMER APPLIANCES AT AT MO (MB) GHATKOPAR UNDER GE (NW) BHANDUP
2026_MES_758652_1
8490/B
Open Tender
Civil Works
270 days
MO (MB) GHATKOPAR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (NW) BHANDUP
₹20,000
Yes
23 May 2026
30 Mar 2026
1 May 2026
30 Mar 2026
30 Apr 2026
13 Apr 2026
30 Mar 2026 - 8 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
Quarterly maintenance of water coolers of any make installed at Naval Depot Area Ghatkopar to check water quality, preventive and breakdown maintenance, lubrication, power supply, repair and replacement of filter candles time to time and the water cooler under contract will be serviced for times during the contract time as per standard checklist, compressor will be checked for its proper functioning. All breakdown calls will be attended to during the contract period.The Blower motor will be checked,the driver set of the blower section wll be inspected but tension adjusted and belts changed. Any defects in the electrical item and control wiring will be attended during contract period. Cost of spare parts/consumeables required shall be borne as per type of contract and shall be applicable to all activities specified under contract etc complete all as specified and directed. | - | Each | - | - | |
Dismantling of existing defective unserviceable compressor of any capacity from window or split AC, Refrigerators, water coolers etc complete all as specified and directed. | - | Each | - | - | |
Supply & Fix in repair new hermetically sealed compresor in split type AC, 1.5/2.0 Ton capacity including initial filling of refrigerant gas to the required pressure, brazing, electric/piping connection etc complete all as specified and directed. | - | Each | - | - | |
Supply & Fix new hermetically sealed compresor in Water Cooler any make 80 Litres capacity. | - | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
TENDERDOCUMENTS.pdf
Tender Documents • 1.37 MB
BOQ_849768.xls
BOQ • 1.05 MB
Download all tender documents and submit your bid