Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.7 L+₹4.9 L (27.2%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹23.9 L
EMD Value
₹47,840
Closing Date
14 Jun 2021, 6:00 pmClosed
GE(U) E/M Meerut Cantt
GE(U) E/M Meerut Cantt
TENDER FOR ITEM RATE CONTRACT FOR PROVN OF LED STREET LIGHTS ALONG WITH STEEL TUBLAR POLE FROM 33 MRS SHIVAJI LINE TO 32 INF BDE UNDER GE(U) MEERUT CANTT
2021_MES_436103_1
8328/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
Meerut Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE(U) E/M Meerut Cantt
₹47,840
Yes
11 Aug 2021
15 May 2021
21 Jun 2021
15 May 2021
14 Jun 2021
31 May 2021
15 May 2021 - 22 May 2021
Amount
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundations etc. or for shafts, well cess pits, manholes,pier holes, laying of pipe and cables etc. but not exceeding 10 sqm on plan including dressing/trimming sides and levelling/grading & ramming bottom of excavation and getting out in soft/loose soil complete all as specified.
Returning ,filling in , including spreading , levelling , watering and well ramming in layer not exceeding 25 cm thick in soil complete all as specified.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Material and labour river sand for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . ( Note: Punned thickness shall be measured for the purpose of payment)
M&Lfly ash old size bricks , straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 25 sqmm 4 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 16 sqmm 4 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
S&F pole mounting type junction box factory made of size 350x250x150mm of CRCA sheet duly powder coated with front openable hinged door , locking arrangements, with 4 Nos aluminium bus bars 40 Amps rating mounted on porcelain insulator, cable glands and lugs consisting DIN type rails for fixing MCB SP 6/10 Amps, 10 kA suitable for domestic loading , -01 no. including mild steel flat iron clamp made out of 40x4mm FI, nuts, bolts and washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.(MCB shall not be measured and paid separately and shall deemed included in the unit rate)
S&F PVC insulated wire copper conductor 3 core 2.5 sqmm 1100 volt grade for connection junction box to street light including PVC rigid conduit 20 mm external dia. Rigid non metallic PVC conduit medium grade, exclusive of boxes ( Junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers , lock nuts, saddles, pipe hook, etc. complete all as specified and directed.
S&F Energy saving & environment friendly LED street light made out of pressure die cast anodised aluminium housing with polycarbonate or flat glass optical cover, system power euqal to less than 90 watt to achieve B1 class road illumination as per IS: 1944 and as per national lighting code each LED >1 watt and <3 watt , Luminous of efficiency of LED >= 135 Lumens/Watt, ,CRI >70, CCT > 5000K to 6500 K with LED life span at 70% of light output >50000 hours (L70) with suitable driver 140V to 270V universal type, with bult in surge protection >5KV, 50 Hz +/- 3% , pf 0.95, THD <10% with system efficiency >85 lumens/ Watt and power efficiency >=90% and overall IP 65 or better , , driver and luminaire shall comply LM-79/IS:16106 including 32mm nominal bore light grade GI pipe brackets made out of 1.5m long GI pipe, bent to shape, and fixed to poles/ walls with 2 Nos MS mild steel FI brackets of 40x6mm, comprising 4 Nos MS hexagonal head bolts of 12mm dia, 75mm long with washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and making connections with cable complete all as specified and directed. and making connections complete all as specified and directed by EIC.
Supplying and fixing 50mm nominal bore Galvanised mild steel pipe /tubing, light grade for protection of earth lead / passing cable complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified (Excavation & Earth work , Mild steel clamps, bolts , nuts and washers shall be measured and paid separately)
M&L for auguring of hole suitable for passing 40mm to 100mm bore pipe in true horizontal position under road, PCC paths etc., by means of mechanical ring/ auger after doing ultrasound to prevent any damage to existing cables pipe line specified and directed coming in the route not exceeding 1.5 m in depth below existing surface level of road and not excd 30M in length complete all as specified. Note: Pipe shall be measured and paid separately under appropriate items and any damage to existing cables of anytype shall be made good by the Bidder without any extra cost to department.
M&L earthing complete with galvanised steel earth plate electrode 600x600x6.3 mm thick, burried directly in to ground ( earth pit) not less than 2.25 metres deep below GL with top edge of earth plate ot less athn 1.50 m below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to GI earth strip 32x6mm thick (7.5M LONG) soldiered and rivetted to earth plate and protected by the GI pipe light grade 40 mm nominal bore(7.5 m long) and watering pipe medium grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel , wiremesh, etc complete including necessary earth work and excavation in any type of soil , PCC 1:3:6 type C1 earth pit and Precast RCC 1:2:4 type B1 cover 50 mm thick duly reinforced with 6 Nos 8 mm dia. TMT bars ,with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I
Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron / Mild steel base plate, CI finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work in soft/ loose soil , PCC 1:3:6 type C2 in foundation and around poles and PCC 1:2:4 type B1 as in plinth block duly finished even and smooth without using extra cement, disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting exposed surafces steel tubular poles with two coats of aluminium paint over one coat of red oxide primer and and black bituminous paint on steel surafces embedded in concrete and providing 300 mm wide bands (5 bands/ straps with fluorescent synthetic enamel paint in alternate colour of black and white from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and shown in drg No.TD/EM/1and directed.
S&F 40 mm nominal bore GI pipe brackets made out of light grade pipe of required length not less than 1.20 M consisting adapter to suit the opening of street light on one end alongwith integrated fabricated adaptor round cup type with 4 Nos studs on outer side to fix the bracket on top of existing steel tubular pole two way with necessary MS clamps with one coat of red oxide and two coats of aluminium paint upon fabricated adopter including nuts, bolts and washers complete all as specified .
S&F 40mm nominal bore GI pipe brackets made out of light grade pipe of required length not less than 1.5M duly bended and fabricated to 120 degree to shape consisting adapter (where required) to suit the opening of street light fitting, mounting brackets made out of 350mm long or higher mild steel FI 40x6mm required shape (Two Nos per GI pipe bracket) duly fitted with 4 Nos Mild Steel bolts 10mm dia, 50mm long with nut and washers or providing reducers and GI pipe of size suitable for existing top fixed bracket duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, and making connection with cable complete all as specified and directed to poles etc.
M&L for cutting the existing bitumenous /PCC road / pavement / foot path upto 0.30 Metre depth and 0.20 Metre width and gettingb out excavated material and making good the damaged portion by filling mass concrete in PCC 1:2:4 type B2 using 40 mm graded crushed stone agregate upto existing level of road/pavement/footpath as specified and directed.
Supplying and fixing automatic operation street light timing switch having lighting control (ON-OFF) through Astronomical Calculation of Sun rise/ sun set by setting date, time and degree of longitude and latitude without separate light sensors and prewired with suitable size of copper conductor single core PVC insulated and sheathed cable and all mechanism fitted into panel, outdoor type , pole mounted with FI 25x4mm clamps , nuts, bolts and washers dully painted, connecting and testing factory made , epoxy powder coated, Three Phase street light panel, digital 24 hrs, suitable for 5KW (max) complete with under and over volt protection relay, 16Amps FP Contactor, and 20 Amps SPN MCBs , 415V and fixed on pole/ wall/ feeder pillar complete all as specified and directed.
Supply installation testing and commissioning of 3 Phase 5KVA, GCMS (Group control management system) central LT Panel with on off of contactor for collective control, with input and output MCB 3 phase panel meter, remote data monitoring, notification of faults, suitable for surge protection, rotary switch for mannual operation, 2mm, MS sheet enclosure with proper earthing arrangements complete all as specified and directed- Note- The GCMS should have following features- (a) Input to GCMS shall be 3 phase control/1 phase grid power input and with 3 phase (Common phase /individual phase control/1 phase output for load with option to switch on and off the load (b) GCMS shall be able to measure voltage , current, power factor, Active power, apparent power, metering cumulative active energy , metering cummulative apperent energy (c) Time scheduling which could be defined from the GUI running locally in smart device (d) Communication-GPRS commuication between GCMS and cloud server street lights for futuristic expansion (e) Wireless local control for field staff to on/off GCMS in case of GSM failure.
M/S JPS Electrical Engineer & Contractor
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .