| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹7.1 L+₹5,581.59 (0.80%)Rejected-Finance Y 49 Y BLOCK HAUZ KHAS SOUTH WEST DELHI NEW DELHI DELHI 110016 | SOUTH DELHI | DELHI | 110016 | L2 | Rejected-Finance Higher rates | |
| 3 | L3₹7.3 L+₹30,118.76 (4.30%)Rejected-Finance | L3 | Rejected-Finance Higher rates | |
| 4 | L4₹7.7 L+₹69,596.81 (9.94%)Rejected-Finance | L4 | Rejected-Finance Higher rates | |
| 5 | L5₹8.0 L+₹95,659.93 (13.7%)Rejected-Finance 134 BLOCK NO 2 HINDWAN HISAR HISAR | HISAR | HARYANA | 125001 | L5 | Rejected-Finance Higher rates |
Tender Value
₹6.8 L
EMD Value
₹13,500
Closing Date
9 Apr 2021, 5:00 pmClosed
Executive Engineer
Estate Office, CCS HAU, Hisar
Repair renovation of 3 office rooms (situated at 2nd floor) for the Department of Foods and Nutrition in the premises of College of Home Science at CCS HAU, Hisar (including EI work)
2021_HRY_166490_1
3206
Open Tender
Civil Works
Works
60 days
CCS HAU
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
₹13,500
Yes
2 Jun 2021
27 Mar 2021
12 Apr 2021
27 Mar 2021
9 Apr 2021
27 Mar 2021
Amount
Civil work 1 to 16:- Dismantling brick work, tile masonry or tile lining and tile terracing {HSR 8.5(b)} (b) in cement
Dismantling roofing (HSR 8.8(a)} (a) first class mud roffing
Scraping {HSR 8.32(c)} (c) Cement plaster
11.43 cm thick brick wall with every fourth course reinforced with hoop-iron laid in 1:4 cement stone dust (from crusher) mortar in superstructure. (HSR 11.51)
Terracing consisting of tiles 22.86 cm X 11.43 cm X 3.81 cm laid over 87.50 mm mud filling on a layer of 25 mm mud plaster and an other layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65 kg per sqm on top of R.C.C slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc. (HSR 13.13)
Cement concrete 1:2:4 gola 10 cm X 10 cm quadrant along junction of roof with parapet wall finished smooth, where specially specified (HSR 13.64 )
Providing and fixing false ceiling with 12 mm thick Gypsum Board fixed on M.S. steel runners frame including cost of screws angles, cleats, rawel plugs with taping, filling with Gypsum compound and applying priming coat etc. complete in all respects (HSR 13.91)
Providing and fixing mineral fibre false ceilings tiles at all hieghts of size 595 x 595 mm of approved texture, design and pattern, the tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 85%, Thermal Conductivity K = 0.052 (-) 0.057 w/m k, Fire Performance as per (BS 476 pt - 6 & 7) in true horizontal level suspended on interlocking T-Grid of hot dipped all round gavanized iron section of 0.33 mm thick (galvanized @ 120 gsm) comprising of main T runners of 15 x 35 mm of length 3000 mm, cross T of size 600 x 600 mm suspended from celing using galvazied mild steel item (galvanizedd @ 80 gsm) 50 mm long 8 mm outerdiameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85 x 25 x 2 mm, spaced at 1200 mm centre of centre along main 'T'. The suystem should rest on periphery walls/partitions with the heop of GI perimeter wall angle of wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all hieghts, The work shall be carried out as per specifications, drawings and as per directions of the Engineer-in-charge. with or without groves (HSR 13.92)
12 mm thick cement plaster 1:4 on walls (HSR 15.5)
Cement pointing 1:2 flush on flat brick flooring (HSR 15.71)
Painting two coats with synthetic enamel paint in all shades on old wood work or metallic or plastered or concrete surfaces to give an even shade including rubbing down old paint (HSR 16.5)
Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surfaces (HSR 16.25)
Distempering with washable oil bound distemper (of approved manufacture) two coasts excluding priming coat on new work (HSR 16.57)
Providing and applying two coats of white cement based putty over plastered surface and grinding the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc., complete (J.K/ Birla make). (HSR 16.81)
Providing and fixing vitrified tiles of size 600 mm x 600 mm of approved make in flooring, laid in any pattern as specified over base of adhesive of reputed brands such as Pidilite, Laticrete, Ferrouscrete & Valendure as per IS specification 15477-2004 and jointed with white cement slury mixed with pigment to match the shade of tiles.(ns) Notes: i. Tile shall be premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, JOHNSONS, RAK, ORIENT BELL AND SIMPOLO. ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this.
Providing and fixing vitrified tiles of size 600 mm x 600 mm of approved make in skirting/ dado, laid in any pattern as specified over base of adhesive of reputed brands such as Pidilite, Laticrete, Ferrouscrete & Valendure as per IS specification 15477-2004 and jointed with white cement slury mixed with pigment to match the shade of tiles. (NS) Notes: i. Tile shall be premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, JOHNSONS, RAK, ORIENT BELL AND SIMPOLO. ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this.
Electrical work 17 to 55:- MINIATURE CIRCUIT BREAKER AND ISOLATOR: {HSR 31.17(ii)} Supply and erection of miniature circuit breaker/isolator 240/415 V in the existing distribution board including making necessary connections (a) Miniature Circuit Breakers of 9 K.A. breaking capacity (ii)6-32 amp. SP MCB
(ii) 32 amp. TPN MCB
(iii) 63 amp. TPN MCB
Miscellaneous {HSR 31.35(i)(a)} (i) Supply of M.S. Pipe (B-Class) for suspension rod of ceiling fan including threading if required. (a) 15 mm dia
S/E of PVC unsheathed copper conductor cable single core 1100 volt grade in pipe of suitable size excluding cost and erection of pipe {HSR 31.40 (i)} (i) Size 1.5 sqmm(3/0.81mm)
(ii) Size 2.5 sqmm(3/1.05mm)
(iii) Cable size 4 sqmm (7/0.85 mm)
(iv) Cable size 6 sqmm (7/1.05 mm)
S/E of PVC conduit pipe ISI marked (Medium) recessed in wall/ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work (HSR 31.44) (ii) 25 mm dia
Pdg. and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. (HSR 31.56) 10 amp. 1 way switch
20 amp.switch
10 amp. Socket
16 amp. Socket
Bell push
Fan regulator
Call bell ding dong (Monitica)
Blinking plate
Pdg. and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. (HSR 31.57) 1 & 2 Modules
3 Modules
6 Modules
8 Modules
12 Modules
Supply installation testingan commissioning of wall free standing floor mounting dust & vermin proof compartmentalized cubical panel made out of 2 mm thick CRCA sheet required hardware 3 mm thick bakelite sheet providing all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of zinc/Red oxide primer followed by 2 coats of powder cating in grey or required shade after rinsing. the panle having PU/Neoprene rubber gasket of not less than 3 mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipment/ switch wear.Transparent arcylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet 3 mm thick for separately cable alley to BBC from switch chamber Extended solid copper bars up to cable alleys shall be provided for outgoing connection which shall be paid as extra tiems side walls and cable alley compartments shall be haiving bolted type doors with detachable extension type strcture. the panel will be complete with control wiring ( copper) and fuse protection ( only outer area on all sides shall be measured ) (HSR 31.63)
Supply and fixing of copper bus bar duly tinned by means of SMC/DMC type insulator high tensile nuts and bolts spring washers fixing go same in existing panel including bending, cutting in required shape and size and insulation with colour coding heat srinkable PVC insulation complete in all respect. (HSR 31.64)
Supply and erection of module case circuit breaker single pole/4 pole on wall on existing pedestal including bounding to earth and making necssary connection required to complete the job in all respect upto the entire satisfaction of Engineer incharge of the work. (HSR 31.69) (iv) 4 pole MCCB 6 to 63 amp.
(v) 4 pole MCCB 100 amp.
Supply and laying of multicore telephone cable condutor size 0.51 mm bright annealed copper condutor PVC insulated and sealed in existing pipe channel and making necessary coneection complete in all respect up to the entire satisfaction of the Engineer-in chage of the work. (HSR 31.78) (i) 2 Pair telephone wire
S/E/T/C of cat-6 cable in existing PVc conduit /PVc channel complete in all respect with all labour and material required to complete the job in all respect. (HSR 31.80)
Supply, erection of 0.51 mm jelly filled armored telephone cable loose in existing pipe/tranches including testing & commissing charges, complete in all respect with the entire satisfaction of Engineer-in-charge. (Make: Delton/Finolex). (NS) 10 Pair
Supply, erection, laying and testing of D.P. including the cost of krones, base plate, 40mm dia G.I. pipe for incoming and outgoing cable and main box having locking arrangement. (NS) 10 pair DP (Make: Delton/Finolex)
S/E of AC ceiling fan capacitor type complete with shackle, 300mm down rod etc. with rating 5 star . {NS} i) 1200mm sweep. Make: Usha, Orient, Crompton.
S/E of AC ceiling fan capacitor type complete with shackle, 300mm down rod . {NS} i) 1400mm sweep. Make: Usha, Orient, Crompton.
S/E of recessed type 42 Watt full window glare free opal diffuse LED Panel of size 595x595 mm suitable for Armstrong/POP/GB ceiling with M.S. Powder coated white housing. Total system lumen of 42 watt LED should be 4600 or above in cool day light (5600K to 6500K), Power factor >0.95, CRI (Ra) >80, LED Lamp efficiency ≥ 140 lm/w, Average life > 50000 hours, complete with all accessories as required with connections (Industrial) Make: Havells (NS)
S/I/T/C of push ON/OFF type 25 A modular type motor starter switch (white color) for AC's including the cost of petty material required to compete the job upto entire satisfaction of Engineer-in-charge. (NS) Make;- Schneider/Crabtree/Athena
S/E of surface/wall mounted ≤20W integrated LED 4 feet fitting with Epoxy Powder coated white/Grey extruded aluminium channel housing for efficient heat dissipation. Total system lumen of 20 watt LED should be ≥ 2000 or above in cool day light (5700K to 6500K), Power factor >0.95, CRI >80, Average life >50000 hours. Complete with mounting Brackets & accessories as required with connections(Industrial) Make: Philips, Havells, Wipro, Bajaj. (NS)
Providing and installing split type air conditioners, five star rating inverter type with copper coils 2.0 ton capacity ± 10%) fitted with super tropical - DC PAM inverter- return cooled - rotary compressor operating on refrigerant R-410-A suitable for wall mounting confirming to IS : 1391 (part-2)/92 (except power consumption norms) with upto date amendments, suitable for operating on 230 volts, 50 Hz single phase A.C. supply having following specifications:- (i) Cooling coil row -3 Nos. (ii) Air flow (CMH) -1450 cum/ hr. (iii) Sound level (H/M/L)- 41/38/34/25(silent mode) (iv) Louvers swing- 3D + 3D Auto etc. complete in all respect MAKE :- O General/Mitsubishi (Heavy Industries) (five star rating) Model as approved by the Engineer-in-Charge. (NS)
Providing and installation of automatic voltage stabilizer of 5.00 KVA capacity (heavy duty) copper wound 100 up voltatge ofV-Guard make ISI marked complete in all respect. (N.S.)
Providing and fixing extra copper tubing/regrigerent pipe for above split air conditioners (if required) consisting of inlet, outlet pipes, insulation and electric wiring etc. as per requirement, complete in all respect beyond 4.0 metres length. (NS) NOTES :- INSTALLATION OF AIR CONDITIONERS INCLUDES:- 1. Mounting/ fitting indoor and outdoor units at their respective locations 2. Providing & laying refrigerant pipe line of four metres length and beyond (if required) and connecting both the units after drilling holes in the wall, if required. Thickness of the copper tubing shall not less than 0.80 mm. 3. Insulating the suction pipe with expanded polythene pipe tubing. 4. Providing & laying drain pipe to throughout the condensate water being formed in the indoor unit 5. Leak testing entire system 6. Charging refrigerant gas in the unit 7. Electric wiring ; suitable electric wiring and switch should be provided with in 4 metres of the location of the units as per requirement 8. PVC channels for concealing the pipes etc. 9. Refrigerant piping thickness- 18 guage (1 mm) (i) Liquid line :- 6.35mm (1/4") (ii) Gas line:- 15.88mm(5/8") 10. Providing and fixing 2.5 sqmm x 4 core coper wire sheathed for connections and communication between indore unit to outdoor unit. (NS)
Providing and fixing in position powder coated MS stands for outdoor units of air conditioners including suitable nuts & bolts etc. of best quality complete in all respect (NS)
AV Science And Technologies Pvt Ltd
SR Works and Constructions
PRB ASSOCIATES
Ajay Contractor
Suraj Bhan Contractor
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .