| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 CrAdmitted-Finance | ₹4.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.4 Cr+₹36.1 L (8.84%)Admitted-Finance | ₹4.4 Cr+₹36.1 L (8.84%) | L2 | Admitted-Finance |
| 3 | L3₹5.4 Cr+₹1.3 Cr (31.2%)Admitted-Finance | ₹5.4 Cr+₹1.3 Cr (31.2%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical NON-RESPONSIVE |
| Sl No | Description | Qty | Unit | M/S MOHD ALYASS BHAT GOVT CONTRACTOR L1 | M/S MAGOTRA ENGINEERS and CONTRACTOR L2 | Ravi Kant L3 |
|---|---|---|---|---|---|---|
| 1.00 | Earthwork in excavation by manual means in trenches for foundations, drains, pipes, cables etc (Nit exceeding 1.5Mtr in width) and for shafts, wells, cesspits and like not exceeding 10 sqm on plan, depth upto 1.5 Mtr including disposal of excavated earth upto 1 Mtr from cutting edge, disposed earth is to levelled and neatly dressed in all kinds of soils. | 365.73 | Cum | - | - | - |
| 2.00Providing and laying in position cement concrete of specified grade excluding cost of centring and shuttering - All work upto plinth level. | ||||||
| 3.00 | a) 1:4:8 (1 cement : 4 Coarse Sand : 8 Graded Stone) 40mm size crushed | 116.34 | Cum | - | - | - |
| 4.00 | b) 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm size) crushed | 11.57 | Cum | - | - | - |
| 5.00Centering and shuttering including strutting, propping etc and removal of form for:- | ||||||
| 6.00 | a) Foundation, footings, bases of columns etc for mass concrete | 96.89 | Sqm | - | - | - |
| 7.00 | b) Lintels, beams, plinth beams, girders, bressumer and cantilever. | 786.4 | Sqm | - | - | - |
| 8.00 | c) Suspended floors , roofs, landings, balconies, Shelves & access platform. | 361.79 | Sqm | - | - | - |
| 9.00 | d) Column, Pillars, piers, abutments, posts, struts etc | 446.83 | Sqm | - | - | - |
| 10.00 | e) Spiral staircases (including landing) | 1,007.4 | Sqm | - | - | - |
Tender Value
₹5.5 Cr
EMD Value
₹10.9 L
Closing Date
11 Jun 2020, 2:00 pmClosed
ER. GIRDHARI LAL
Office of the Deputy General Manager, JKPCC Ltd., Unit 2nd, Rail Head Complex Jammu.
Construction of Additional Block of Indira Gandhi Govt. Dental Hospital, Amphalla Jammu by way of Construction of Boundary Wall partition walls, Aluminium Partitions and glazing works, false ceiling, Ramp, Connecting Steel Tubular Bridge, etc.
2020_PWDJK_97161_1
e-NIT NO. 03/2ND of 2020-21 Dt. 20-05-2020
Open Tender
Civil Works
Item Rate
180 days
JAMMU
Please refer Tender documents.
7 documents required · 7 mandatory
₹5,000
Yes
Financial Controller, JKPCC Ltd.
₹10.9 L
Yes
O/o The Managing Director, JKPCC Jammu
30 Jun 2020
23 May 2020
12 Jun 2020
23 May 2020
11 Jun 2020
26 May 2020
5 Jun 2020
Amount
Earthwork in excavation by manual means in trenches for foundations, drains, pipes, cables etc (Nit exceeding 1.5Mtr in width) and for shafts, wells, cesspits and like not exceeding 10 sqm on plan, depth upto 1.5 Mtr including disposal of excavated earth upto 1 Mtr from cutting edge, disposed earth is to levelled and neatly dressed in all kinds of soils.
Providing and laying in position cement concrete of specified grade excluding cost of centring and shuttering - All work upto plinth level.
a) 1:4:8 (1 cement : 4 Coarse Sand : 8 Graded Stone) 40mm size crushed
b) 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm size) crushed
Centering and shuttering including strutting, propping etc and removal of form for:-
a) Foundation, footings, bases of columns etc for mass concrete
b) Lintels, beams, plinth beams, girders, bressumer and cantilever.
c) Suspended floors , roofs, landings, balconies, Shelves & access platform.
d) Column, Pillars, piers, abutments, posts, struts etc
e) Spiral staircases (including landing)
Providing and laying damp proof coarse 40mm thick / levelling coarse with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) crushed.
Providing and laying reinforced cement concrete 1:1.5:3 (1cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20mm nominal size) in suspended floors, balconies, landings and stair case having upto 15º slope excluding cost of centering & shuttering all work upto Floor V level.
Providing and laying in position specified grade of reinforces cement concrete excl. cost of centering shuttering, finishing and reinforcement - All work upto plinth level
a) 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
b) 1: 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Steel work welded in built up sections / framed work including cutting, hoisting, fixing in position and applying a priming coat of approved coat of approved steel primer using structural steel etc as required. In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works
Chequerred precast cement concrete tiles 22mm thick within footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and cleaning etc complete on 20mm thick bed of cement mortar in 1:4.(1 cement : 4 coarse sand). Light shade using white cement.
Reinforcement for RCC work including straightening cutting, bending, placing in position and binding all complete for Thermo Mechanically Treated (TMT) steel bars.
Brick work with common burnt F.P.S bricks of class designation 75 in foundation and plinth in cement mortar 1:6 (1 cement : 6 fine sand)
Brick work with common burnt clay F.P.S (non-modualar) bricks of class designation 75 in foundation and plinth in cement mortar 1:4 (1 cement : 4 fine sand)
Extra for brick work in superstructure above plinth level upto floor V level (Manual means)
Half brick masonry with bricks of class designation 75 in foundation and plinth in cement mortar 1:4 (1 cement : 4 coarse sand)
Extra for half brick masonry in superstructure above plinth level upto floor V level
Cement plaster in fine sand 15mm on rough side of single or half brick wall of mix 1:6 (1 cement : 6 fine sand)
Cement plaster in fine sand 15mm on rough side of single or half brick wall of mix 1:4 (1 cement : 4 fine sand)
Finishing walls with water proofing cement paint of reqd. shade New work (2 or more coats) applied @ 3.84 kgs / sqm
Providing and fixing tiles false ceiling of specified materials of size 595 x 595mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams / sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24 x 38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm centre to centre and cross "T" of size 24 x 25mm made of 0.30mm thick (minimum) sheet 1200 mm long spaced between main "T" at 600mm center to center to form a grid of 1200 x 600mm and secondary cross "T" of length 600mm and size 24 x 25mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200 x 600m panel to form grids of 600 x 600mm and wall angle of size 24 x 24 x 0.3mm and laying false ceiling tiles of approved texture in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings fixtures, smoke detectors etc Main "T" runners to be suspended from ceiling using GIslotted cleats of size 27 x 37 x 25 x 1.6mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8mm spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be prepainted with polyster paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. with 12.5mm thick square edge PVC laminated Gypsum tile of size 595 x 595mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 Part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.
Providing and fixing Aluminium work for Doors, windows, ventilators and partitions with extruded built up standard tubular sections or any other section of approved make conforming to IS:733 and IS:1285, fixed with dash fastener of reqd. dia and size including necessary filling up of gaps at junctions i.e at top, bottom and sides with required EPDM rubber etc Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever reqd., Aluminium snap beading for glazing / panelling, C.P brass / S.S Screws all complete as per directions of Engineer I/c. (Glazing, Panelling to be paid separately)
For shutters of Doors, windows & ventilators including providing and fixing hinges / pivots and making provision of fixing fittings incl. cost of EPDM rubber (fittings shall be paid separately).
Providing and fixing glazing in Aluminium door, window, ventilator shutters and partitions etc with EPDM rubber / neopene gasket etc complete as per architectural drawings and directions of Engineer I/c; with float glass panes 5.50mm thickness
Providing and fixing 12mm thick prelaminated particle boardflat pressed 3 layer or graded wood particle board (Conforming to IS 12823 Grade I type II) in panelling fixed in Aluminium Doors, window shutters and partition frames with C.P brass / S.S screws etc complete (Prelaminated particle board with decorative lamination on both sides)
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS:6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125Kg for Doors including cost of cutting floors, embedding in floors as reqd. and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S Sheet outer box with slide plate complete as per direction of Engineer I/c with stainless steel cover plate minimum 1.25mm thickness
Providing and fixing of Aluminium fittings including necessary screws etc (Fittings shall be ISI marked)
a) Tower Bolt
b) Handles
c) Door Closer (Conforming to IS : 3564)
d) Locks
Steel work of grade 1st 310 MPA in built up tubular (Square or rectangular hollow tubes) trusses etc including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer including welding and bolted with nuts, washers etc complete
Structural steel work of grade E250 as per IS 2062 riveted, bolted or welded in built up section, chequred plate, trusses and framed structure including cutting, hoisting fixing in position and applying a priming coat of approved steel primer all complete
Providing and fixing bolts 750mm long in cement concrete M20 Grade including labour for drilling of holes
Providing and fixing of 0.5mm thick Hi-rib sheets of standard shade and quality with SDS and over lapping complete as per the instruction of Engineer Incharge
Carriage of Materials by Mechanical Transport (M.T)
a) Sand (10 Km)
b) Aggregate (10 Km)
c) Bricks (15 Km)
Labour charges for cast in situ concrete work using brick bat (40 / 20 mm), volumetric batching upto plinth level including curing, hire and running charges of concrete mixer, vibrator, T&P but excluding formm work cost (any mix).
Labour for making brick aggregate of required size 40mm / 20mm and down guage
Labour Charges for fixing vitrified / ceramic floor tiles (available at site) with 10mm / 20mm thick cement mortar and finishing the joints with grout of required shade.
Providing and fixing of vitrified tiles on floor (size 600 x 600mm) with water absorption less than 0.08% and conforming to IS: 15622 of approved make (Kajaria, Somany, RAK or equivalent double charge) of approved colour and shade, laid on 20mm thick cement mortar 1:4 including grouting the joints with while cement and matching pigments etc complete
Labour Charges for fixing ceramic tile on wall (available at site) with 10mm / 20mm thick cement mortar and finishing the joints with grout of required shade.
a) Labour Charges for fixing vitrified tile on wall (available at site) with 10mm / 20mm thick cement mortar and finishing the joints with grout of required shade.
Providing and fixing of vitrified tiles on walls (size 800 x 1200mm) with water absorption less than 0.08% and conforming to IS: 15622 of approved make (Kajaria, Somany, RAK or equivalent double charge) of approved colour and shade, laid on 20mm thick cement mortar 1:4 including grouting the joints with while cement and matching pigments etc complete
Supply of Sand including loading, unloading and duly delivered at site (stack measurement less by 7% moisture content)
Supply of Brick Bats including loading, unloading and duly delivered at site.
Carriage of Materials by Head Load
A) Sand
a) 1st Floor (from dumping ground to 1st floor)
b) 2nd Floor (from dumping ground to 2nd floor)
c) 3rd Floor (from dumping ground to 3rd floor)
d) 4th Floor (from dumping ground to 4th floor)
B) Carriage of Tiles by Head Load
a) 1st Floor (from dumping ground to 1st floor)
b) 2nd Floor (from dumping ground to 2nd floor)
c) 3rd Floor (from dumping ground to 3rd floor)
d) 4th Floor (from dumping ground to 4th floor)
M/S MAGOTRA ENGINEERS and CONTRACTOR
Ravi Kant
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
SBDE03Boundary.pdf
Tender Documents • 0.40 MB
BOQ_184384.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .