Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical NEAR RAM MANDIR PATAN ROAD UNDAL JHALAWAR 326023 | JHALAWAR | JHALAWAR | RAJASTHAN | 326023 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical K H NO 24 PP NO 1697 130 Z B NAJAFGARH DELHI INDIA | DELHI | WEST DELHI | DELHI | 110043 | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical 22 BEHIND MODERN PETROL PUMP BEHIND MODERN PETROL PUMP JHALAWAR ROAD KOTA KOTA RAJASTHAN 324007 | KOTA | RAJASTHAN | 324007 | Admitted-Fee/PreQual/Technical |
| 4 | Not Admitted-Fee/PreQual/Technical ROON MARG OLADAN TEHSIL MERTA CITY MERTA CITY NAGAUR RAJASTHAN 341511 | NAGAUR | RAJASTHAN | 341511 | Not Admitted-Fee/PreQual/Technical Others-Submission of EMD fees is late (after EMD submission time and date 15.10.2026) |
Tender Value
₹20.3 L
EMD Value
₹40,680
Closing Date
6 Oct 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
OFFICE OF THE SUPERINTENDING ENGINEER (MM)
KaTPP Near Undal Village Dist Jhalawar Rajasthan
Procurement of Voltage Transformers (PT) and Current Transformers (CT) for River Water System and Construction Supply Panels of unit 1 and 2 at KaTPP, Jhalawar
2026_RRVUN_586458_1
TN-1315(MM)
Open Tender
Electrical Goods/Equipments
Item Wise
KaTPP Near Undal Village Dist Jhalawar Rajasthan
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Sr AO KaTPP
₹40,680
6 Oct 2026
13 Aug 2026
6 Oct 2026
13 Aug 2026
6 Oct 2026
13 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0Voltage Transformers | |||||
| 1 | Voltage Transformers for 33 KV (RWS)
(IS/IEC Standards 3156/1992, Ratio:33000/√3/110√3/110√3 V
Insulation Level: 36/70/170KV FREQ. 50 HZ,
Insulation Class: B VF: 1.2 Cont. & 1.9 for 8 Hours
Type: Phase to Earth
Secondary 1 : 110/√3 V, Class 1, 100VA, 1a-1n,
Secondary 2 : 110/√3 V, 3P,100VA,2a-2n Secondary
Terminal On : P2 Side,
Drawing No. :-RVUN/KaTPP/RWS/BRKP/33 KV PT/(33KV/110V) /01 | 3 | Nos | - | - |
| 2 | Voltage Transformers for 11 KV Incomer Panels (DAM)
(IS/IEC Standards : 3156/1992, Ratio:11000/√3/110√3/110√3 V
Insulation Level: 12/28/75 KV FREQ. 50 HZ, VF: 1.2 Cont. & 1.9 for 8 Hours Type:Phase to Earth, Insulation Class: B Secondary 1 :110/√3 V,
Class:1, 100VA, Term: 1a-1n, Secondary 2 :110/√3 V, Class: 3P, VA/Ph:
100VA,Term:2a-2n
Drawing No. :- RVUN/KaTPP/RWS/INCM & BUS PT/11 KV PT-01 | 3 | Nos | - | - |
| 3 | Voltage Transformers for LT Panel (DAM)
Ratio: 415V/110V, VA: 50 VA
Drawing No. :-RVUN/KaTPP/LTP(DAM)/PT-415V/01 | 2 | Nos | - | - |
| 4 | Voltage Transformer for Construction Supply Panel( 3 Nos in each set)
Ratio: 11KV/110 V Three Phase Three Limb Freq. 50Hz
Burden 100VA/Phase, Acc. Class 0.5 Connection λ-λ IL: 28/75KV SV/HSV: 11/12 KV
Drawing No. :-RVUN/KaTPP/PT-(11KV/110V)/CSP/01 (3 pages) | 1 | Set | - | - |
| 5 | Current Transformers for 33 KV
IS/IEC Standards : 2705/1992, Ratio: 150/1-1-1, Insulation Level:
36/70/170KV FREQ. 50 HZ Insulation Class: B, Core 1 : 150/1A Burden:15VA CL. 1.0 Core 2 : 150/1A Burden:15VA CL. 5P ALF: 20
Core 3 : 150/1A CL. PS, For Core 3 Min. VK 26[RCT+1]
lex: Less than 30mA at VK/4 V SHORT TIME S.T.C: 16 KA FOR 3 SEC
Secondary Terminal On : P2 Side,
Drawing No. :- RVUN/KaTPP/RWS/BRKP/CT (150/1-1-1)/01 (2 Pages) | 3 | Nos | - | - |
| 6 | Current Transformers for LBS Panel (RWS)
IS/IEC Standards : 2705/1992 FREQ. 50 HZ Insulation Level: 12/28/75KV
Ratio: 400/1 A Insulation Class: B Core 1 : 400/1A CL. PS
For Core1 Min. VK (26Rct+1.0) Max Rs. 1.5lex. Less than 30mA at VK/4 V
Secondary Terminal On : P2 Side
Drawing No.:-RVUN/KaTPP/11KV LBSP/Plant/CT-(400/1)/01 | 2 | Nos | - | - |
| 7 | Current Transformer for 11 KV Bus Coupler Panel (RWS)
IS/IEC Standards : 2705/1992 Ratio: 400/1 Insulation Level: 12/28/75KV
FREQ. 50 HZ Insulation Class: B Core 1 : 400/1A Burden:15VA CL. 5P
ALF: 20 SHORT TIME S.T.C: 16 KA FOR 3 SEC Secondary
Terminal On : P2 Side
Drawing No. :- RVUN/KaTPP/11KV BCP/DAM/CT-(400/1)/ 01 | 1 | Nos | - | - |
| 8 | Current Transformer for 11KV Incomer Panel (RWS)
IS/IEC Standards : 2705/1992 Ratio: 400/1-1-1A Insulation Level: 12/28/75
KV FREQ. 50 HZ, Insulation Class: B Core 1 : 400/1A
Burden:15VA CL. 1.0, Core 2 : 400/1A Burden:15VA CL. 5P ALF: 20 Core 3 : 400/1A CL. PS, SHORT TIME S.T.C: 16 KA FOR 3 SEC Secondary Terminal On : P2 Side, For Core3:Min VK: 104 V MAX Rs. 3.0 Lex Less
than 30mA at Vk/4 V
Drawing No. :-RVUN/KaTPP/11KV INCMRP/Dam/CT-(400/1-1-1)/01 | 3 | Nos | - | - |
| 9 | Current Transformers for 11KV Motor Panel & 6.3 MVA Transformer Feeder
IS: 2705/1992 Insulation Level: 12/28/75KV FREQ. 50 HZ Ratio: 50/1-1 A
Insulation Class: B Type: Phase to Earth Core 1 : 50/1A Burden:15VA
CL. 1.0 Core 2 : 50/1A Burden:15VA CL. 5P ALF: 20 SHORT TIME S.T.C: 16 KA FOR 3 SEC Secondary Terminal On : P2 Side
Drawing No. :- RVUN/KaTPP/RWS/MP&TP/CT-(50/1-1)/01 | 3 | Nos | - | - |
stage.html
html • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
TN1315.pdf
Tender Documents • 11.41 MB
BOQ_1041679.xls
BOQ • 0.30 MB
Extension4.pdf
PDF • 0.71 MB
Ext3.pdf
PDF • 0.71 MB
EXT2TN1315.pdf
PDF • 0.71 MB
Ext1315.pdf
PDF • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .