Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹18.9 LAccepted-AOC R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | 1 | Accepted-AOC L1 | |
| 2 | 2₹21.0 L+₹89,076.26 (4.44%)Rejected-Finance WARD NO 16 HOUSE NO 66 SALLIAN TALAB UDHAMPUR 182 101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | 2 | Rejected-Finance OTHER THAN LOWEST QUOTED | |
| 3 | 3₹21.9 L+₹1.9 L (9.30%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | 3 | Rejected-Finance OTHER THAN LOWEST QUOTED | |
| 4 | 4₹22.7 L+₹2.7 L (13.3%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | 4 | Rejected-Finance OTHER THAN LOWEST QUOTED | |
| 5 | 5₹24.8 L+₹4.7 L (23.4%)Rejected-Finance | 5 | Rejected-Finance OTHER THAN LOWEST QUOTED |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
7 Feb 2022, 6:00 pmClosed
GE AF Udhampur
AF STATION UDHAMPUR
CERTAIN REPAIRS TO VOLTAGE STABILIZER TRANSFORMER AND ALLIED LT ELECTRICAL WORKS AT AF STATION UDHAMPUR
2022_MES_500690_1
GE/AFU-46/2021-22/E8
Open Tender
Miscellaneous Works
Item Rate
334 days
GE AF Udhampur
Please refers tender documents
8 documents required · 8 mandatory
₹500
GE AF UDHAMPUR
₹70,000
25 Apr 2022
10 Jan 2022
9 Feb 2022
10 Jan 2022
7 Feb 2022
24 Jan 2022
11 Jan 2022 - 17 Jan 2022
Amount
Dismantling the defective stabilizer of capacity upto 50 KVA from incoming and out going cables and opening the stabilizer for services charge checking the defects for repairs at site, including connecting and testing complete, all as specified and as directed by Engineer-in Charge.
Dismantling the defective stabilizer of capacity 50 to 150 KVA from incoming and out going cables and opening the stabilizer for services charge checking the defects for repairs at site, including connecting and testing complete, all as specified and directed by Engineer-in Charge.
Supply and filling voltage stabilizer oil low viscosity type conforming to IS 335 for topping up of stabilizer, complete, all as specified and as directed
S&F micro switches, complete, all as specified and as directed . Make :- Kaycee/ESSAN/Volina/as per existing parts
S &F Auto manual switches, complete, all as specified and as directed . Make :- Kaycee/ESSAN/Volina/as per existing parts
S&F high and low voltage indicators, complete, all as specified and as directed Make :- VAISHNO/HARRY/Volina/as per existing parts
S&F panel indicator lamp for main ‘ON’ indication,complete, all as specified and as directed. Make :- VAISHNO/HARRY/Volina/as per existing parts
S&F push button switch, complete, all as specified and as directed . Make :- Kaycee/ESSAN/Volina/Volina/as per existing parts
S&F Volt meter, complete, all as specified and as directed . Make:- ABB/HPL/L&T/Havells/Meco/AE/Premier/Volina/as per existing parts
S&F Electronic sensing card (PCB), complete, all as specified and as directed . Make :- AE/VINTEC/VOLINA/BLUEHILL/Volina/as per existing parts
S&F microprocessor based control card for each phase, complete, all as specified and as directed Make: AE/VINTEC/VOLINA/BLUEHILL/Volina/as per existing parts
S&F rotary switch for voltmeter RY-YB-BR-OFF-RN-YN-BN, complete, all as specified and as directed Make :- KAYCEE/RICO/Volina/as per existing parts
S&F rotary switch for ammeter RY-YB-BR,complete, all as specified and as directed Make :- KAYCEE/RICO/Volina/as per existing parts
S&F servo motor 3 Kg torque,complete, all as specified and as directed Make :- AE/Volina/UNISTER/Volina/as per existing parts
S&F servo motor 10 Kg torque, complete, all as specified and as directed Make :- AE/Volina/UNISTER/Volina/as per existing parts
S&F RC network for servo motor 3Kg/10 Kg, complete, all as specified and as directed Make :- AE/Volina/UNISTER/Volina/as per existing parts
S&F carbon bush any size , complete, all as specified and as directed Make :- AE/Volina/UNISTER/Volina/as per existing parts
S&F dimmerstate unit of capacity 10 to 60 Amps for 10 KVA to 150 KVA, complete, all as specified and as directed Make :- AE/Volina/Green Dot/as per existing parts
S&F Buck and booster transformer(Main Transformer) 10 KVA to 150 KVA complete, all as specified and as directed Make :- AE/Volina/Vintek Electronics./as per existing parts
Taking down shutdown, disconnecting existing primary/secondary repairable transformer of capacity upto 630 KVA indoor /outdoor type removing/ taking down for repair from existing cable and including earth wire all as specified and directed by Engr-in-Charge. NOTE :-The contractor shall return the transformer duly repaired with in 20 days other wise a penalty of Rs 1000/- per day will be recovered from the firm.
M&L for Shifting including loading unloading and transporting of transformer 11 KV of size 50 to 630 KVA capacity with suitable arrangement after complete repair and satisfactory restoring from contractor’s workshop or work site including reconnecting with existing primary power cable and secondary power cable side & earthing of transformer after taking shut down and including testing & commissioning on existing load in the presence of officer nominated and Engr-in-Charge by contract complete all as specified and directed by Engineer-in-Charge. Note :-(i) Winding wire and other items/spares and new transformer oil mentioned in above will be measured and paid separately. (ii) Placing /removing standby transformer in the place of defective transformer under repair including loading /unlaoding, shifting including transportation and make the system/line function will be the responsibility of the contractor, contractor quoted rates shall be inclusive of all these factors.
Material & Labour for Winding the transformer 50 KVA to 630 KVA suitable for secondary original size copper wire complete with all required insulation/ varmishing materials complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Winding the transformer 50 KVA to 630 KVA suitable for primary original size copper wire complete with all required insulation/ varnishing materials complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Winding the transformer 50 KVA to 630 KVA suitable for secondary original size aluminium wire complete with all required insulation/ varnishing materials complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Winding the transformer 50 KVA to 630 KVA suitable for primary original size aluminium wire complete with all required insulation/ varnishing materials complete all as specified and directed by Engineer-in-Charge .
Supply and fixing LT stud bush of brass of brass complete with nuts bolts and washers of brass for 50 to 630 KVA Transformer complete all as specified and directed by Engineer-in-Charge including taking down old .
Supply and fixing HT stud bush of brass of brass complete with nuts bolts and washers of brass for 50 to 630 KVA Transformer complete all as specified and directed by Engineer-in-Charge including taking down old
Supply and fixing synthetic rubberized cord sheet 8 mm thick with suitable holes including replacement of defective nuts and washer of per existing size for 200 to 400 KVA Transformer complete all as specified and directed by Engineer-in-Charge.
Supply and fixing cast iron wheel complete with solit pin etc for transformer 50 to 630 KVA complete all as specified and directed by Engineer-in-Charge.
Temperature gauge circular dia type of standard size and suitable for indoor/outdoor type transformers upto 630 KVA capacity complete, all as specified and as directed
S&F in replacement breather assembly CI of standard size filled with silica-gel for transformer upto 630KVA complete all as directed and specified.
Winding temperature indicator type of standard size and suitable for indoor/outdoor type transformers upto 630 KVA capacity complete, all as specified and as directed
Material and Labour for Dehydration/centrifuging of Transformer oil as per standard procedure upto strength level 60 KV all including Oil topping up etc complete all as specified and directed by Engineer-in-Charge.
Supply and filling of new transformer oil of ISI marked having electric strength not less than 60 KV for topping up complete all as specified and as directed. Make : power/ sweta/ eqt.
Supply and fixing complete gaskit bush/washers for bushing side of transformer complete all as specified and as directed by Engineer-in-Charge including taking down old.
Supply and fixing complete gaskit sheet for bushing side of transformer complete all as specified and as directed by Engineer-in-Charge including taking down old.
Supply and fixing of suitable size of nut bolts/ washers complete all as specified and as directed including taking down old. Make : TVS or equivalent as approved by GE.
Taking down old unserviceable of Transformer insulator ,Supply and fixing of primary bush insulator of transformer complete all as specified and as directed by Engineer-in-Charge.
Taking down old unserviceable of Transformer insulator ,Supply and fixing of secondary bush insulator of transformer complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches in any type of soft / hard soil, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation / laying of pipes and getting out.complete, all as specified and as directed
Returning, filling in any type of soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm.complete, all as specified and as directed
Removing excavated material (soils) not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.complete, all as specified and as directed
Sand cushioning for 8 cm before laying the cable and then after laying the cable 15 cm width of trenches for protection of cables including punning down complete, all as specified and as directed . Note :- Thickness of sand cushioning shall be the thickness after punning down.
Supply and fixing of Brick tiles; common burnt clay building /ducts bricks’ sub-class `B’ Designation 75 (230mmx115mmx75mm) complete, all as specified and as directed
S&F 80 mm dia GI tubing,light grade,for protection of cable passing across the road,under floor etc,complete all as specified and directed.
S&F 50 mm dia GI tubing,light grade,for protection of cable passing across the road,under floor etc,complete all as specified and directed.
M&L for XLPE insulated ,screened,PVC bedded,galvanised steel strip or wire armoured,electric power cable (heavt duty) with aluminium conductor,1100 volts,grade cross sectional area 95 sqmm 3.5 core complete all as specified and directed by Engineer-Charge.including taking down old
M&L for painting of the transformer complete by removing old paint by scraping and providing spary painting with approved synthetic enamelled paint of capacity 63 KVA to 630 KVA all as directed by Engineer-in-charge
M&L for taking down oil from conservator in seperate oil container and taking out unserviceable oil level indicator and replacement of new oil level indicator as per existing size/type/make/model and refilling the same oil and testing etc complete as specified and directed.
Disconnecting the all electrical componant from transformer and opening the top cover after taking out the bush/stud and replacement the all gasket and oil seal of bushing and top cover and rectify the leakage of transformer oil in all respect as directed by Engr-in-charge of capacity 63 to 630 KVA transformer. Note :- All spare parts required during maintenance shall be measured and paid separately).
Renewal of existing GI plate earthig/Cu plate/Chemical earthing with provision of new layers of charcoal, salt and addiing earth enhance material for decreasing the resistance value upto less than one ohm all as specified and directed by Engineer-in-Charge, including cleaning of existing earth plate, strip/wire etc and connecting with new bolts, nuts and washers complete and testing on completion in all respect as directed. Note: - Excavation, PCC for earth pit and cover, watering pipe, funnel with wire mesh, earth lead and protection pipe shall deemed to be included in the quoted rates
S&F galvanised iron strip as earth continuity conductor or main earthing lead fixed to walls or burried in ground of size 32x6 mm complete all as specified.
M&L for earthing with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 metre deep below ground level) vertically, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to galvanized iron wire 32x6mm dia by means of nuts, bolts, washers of GI steel all as shown on electrical plate No 3 of MES Schedule Part I connected to earthing test point and testing on completion with and including necessary excavation and earth work, earth electrode, earthing lead from electrode to equipment/substation, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover, reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 15 mm dia GI light grade earth lead protection pipe, complete all as specified and directed. Note : (i) Main earthing lead from earth plate electrode to test point upto length of 7.50 mtr shall deem to be included in the unit rate quoted by the tenderer against this item. (ii) GI protection pipe and earthing strip beyond 7.5 mtr long shall be measured and paid seperatly . (iii) Test result should be less than 1 ohms or satisfaction of user. (iv) Material should not be less than 60 Kg Coal and 100 Kg Salt in each earthing.
Cleaning the sub station/transformer/two/foul pole structure around 5 m radious in every month duly taking down unwanted material/grass/vegetable roots/small tree etc complete, all as specified and as directed
Preperation of old painted surface of chainlink fencing, angle iron and ms flat of sub station including painting with one coat of synthetic enamel paint of asian make etc complete, all as specified and as directed
S&F in replacement tap changer assembly complete for transformer rating upto 63 KVA to 160 KVA, including connecting up with HT coil and testing for varying voltage complete all as directed and specified by Engr-in-Charge.
Description all as per srl item No 75 here-in-before but for transformer of capacity 200 KVA and upto 315 KVA.complete, all as specified and as directed
Description all as per srl item No 75 here-in-before but for transformer of capacity 400 KVA to 630 KVA. complete, all as specified and as directed
S&F in replacement dry, blue colour silica gel crystal impregnated with cobalt suitable for transformer breather complete, all as specified and directed by Engr-in-Charge.
Precast unreinforced concrete cable cover class HV, TYPE 2, flat, size 450mmx180mmx40mm conforming to IS-5820 (1970), for protection of HT under ground cable over the duct alongwith provision of 02 nos iron handle , complete all as specified and as directed by Engr-in-Charge.
M&L for construction of plinth of size 1.8 x1.8 x 1.2 M (LXBXH) with pcc 1:3:6 type C2 using 40mm graded aggregate incl brick works with old sub class B bricks straight or curved on plan exc 6 m means radius build in CM 1:6 incl rendering for mounting of transformer over all height 2.1 M(0.60m below the ground level and 1.8 m over the ground level) suitable for upto 630 KVA Transformer complete as directed. Note- Drg will be approved by Engr-in-charge
Hiring of cable fault detector machine to detect exact position of faulty XLPE /PVC HT cable, 11000 Volts grade heavy duty aluminium conductor of any size and any length including excavation , relaying of protection cable cover, & removing and earth filling etc complete as specified and directed. Note : If any defect occurred at any place of Udhampur Air Force area, the contractor will provide machnic & fault locator with material with in one hours for rectification of defects. If the contractor not provide the machanie and material with schedule time, the amount will be deduct 1000/hrs after receiving phone/massage/ watsup /email etc complete as specified and as directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE/PVC armoured aluminium conductor cable of size 50 to 95 sqmm complete, all as specified and as directed by Engr-in-Charge.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE/PVC armoured aluminium conductor cable of size 120 to 185 Sqmm complete, all as specified and as directed by Engr-in-Charge.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE/PVC armoured aluminium conductor cable of size 50 to 95 sqmm complete, all as specified and as directed by Engr-in-Charge.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE/PVC armoured aluminium conductor cable of size 120 to 185 Sqmm complete, all as specified and as directed by Engr-in-Charge.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE/PVC armoured aluminium conductor cable of size 50 to 95 Sqmm complete, all as specified and as directed by Engr-in-Charge.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE/PVC armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete, all as specified and directed by Engr-in-Charge.
Material and Laying 40mm graded mechanically crushed stone aggregates, loose filling around distribution transformer yard after scarification and stacking the existing aggregate, complete all as specified and as directed by Engr-in-Charge. Note: The payments shall only be allowed for the new aggregate brought and filling in the yard.
10mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
M & L for Brazing/Welding work with copper brazing/Welding alloy rod with the help of oxygen and LPG cylinder using required copper strip of size 20 mm x 3 mm /25 mm x 3 mm upto 30 cm length along with cleaning work of strip with descaling solution/emery paper all as specified and directed by Engineer-in-Charge.
M & L for Brazing/Welding work with copper brazing/Welding alloy rod with the help of oxygen and LPG cylinder using required copper strip of size 32 mm x 6 mm upto 30 cm length along with cleaning work of strip with descaling solution/emery paper all as specified and as directed by Engineer-in-Charge.
M & L for Brazing/Welding work with GI brazing/Welding alloy rod with the help of oxygen and LPG cylinder using required Galvanised Iron of size 20 mm x 3 mm upto 30 cm length along with cleaning work of strip with descaling solution/emery paper all as specified and directed by Engineer-in-Charge.
M & L for Brazing/Welding work with GI brazing/Welding alloy rod with the help of oxygen and LPG cylinder using required Galvanised Iron of size 32 mm x 6 mm upto 30 cm length along with cleaning work of strip with descaling solution/emery paper all as specified and directed by Engineer-in-Charge.
Supply and fixing plate of Cu strip of size 50 x 6 with GI Nut, Bolt and washer for LT bushing side of transformer complete all as specified and as directed by Engineer-in-Charge.
M & L for MS plate made of 1.6 mm thick of size 30 cm x 30 cm fixed with suitable size ms flat iron with nut, bolt & washer and painted with red colour synthetic enamelled paint and write 8 cm height letter in white colour (feeder Name) complete, all as specified and as directed
M&L for Chain link fencing any type and size as reqd at site (measrured solid), including all mould-ings excluding frame complete all as specified and as directed.
M&L for frame work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete, drilled for fixing of steel sheeting or other covering doors etc. to be prepared for hanging or sliding with and including either hook and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe-290 (Gde E-165) complete all as specified and directed.
M&L 60 mm thick PCC interlocking tiles, rubber moulded using grey cement and pigment of size and shape as approved, including 50mm thick bed with PCC (1:3:6) type C1 with 20 mm graded stone aggregate and including layer of dry sand not less than 40 mm thick, interstices filed in floors/pathway including locking the tiles on all four sides with PCC complete all as specified and as directed.
M&L for type D2 1:4:8 (40 mm graded aggregate) cement concrete in foundation and mass concrete for bricks foundation etc complete as specified and directed
M&L for bricks works with sub class B bricks straight or curved on plan exc 6m means radius built in cement mortar 1: 6 etc complete as specified and as directed
M&L for type B1 1:2:4 (20 mm graded aggregate) for providing cement concerte in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courese strin course, lacing course string courses lacing courses, parapets, and railings upto 60 cm in height copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed .
M&L for disconnecting burnt end or portion of 25 sqmm to 185 sqmm 3 ½ core cable removing the cable from loop including necessary excavation, earthwork, removing brick protection and relaying the same, and reconnecting the cable by removing burnt portion of cable and preparing fresh terminals of LT/HT cable to transformer/panel/pole etc complete all as specified.
Supply & fixing of end termination heat shrinkable joint including sleeves suitable for LT XPLE underground aluminium conductor cable 1000 Volt of grade 25 Sqmm to 50 Sqmm x 3.5 Core cross sectional area including testing after jointing as in replacment after disconnecting the cable from Panel / Pole/Transformer, preparing the end for jointing including all earth work,complete all as specified and directed by Engineer-in-Charge.
Supply & fixing of end termination heat shrinkable joint including sleeves suitable for LT XPLE underground aluminium conductor cable 1000 Volt of grade 70 Sqmm to 150 Sqmm x 3.5 Core cross sectional area including testing after jointing as in replacment after disconnecting the cable from Panel / Pole/Transformer, preparing the end for jointing including all earth work,complete all as specified and directed by Engineer-in-Charge.
Supply & fixing of end termination heat shrinkable joint including sleeves suitable for LT XPLE underground aluminium conductor cable 1000 Volt of grade 185 Sqmm to 200 Sqmm x 3.5 Core cross sectional area including testing after jointing as in replacment after disconnecting the cable from Panel / Pole/Transformer, preparing the end for jointing including all earth work,complete all as specified and directed by Engineer-in-Charge.
Supply & fixing of straight through heat shirankable joint including sleeves suitable for LT XPLE underground aluminium conductor cable 1000 Volt of grade 25 Sqmm to 50 Sqmm x 3.5 Core cross sectional area including testing after jointing as in replacment after disconnecting the cable from Panel / Pole, preparing the for jointing including all earth work,complete all as specified and directed by Engineer-in-Charge.
Supply & fixing of straight through heat shirankable joint including sleeves suitable for LT XPLE underground aluminium conductor cable 1000 Volt of grade 70 Sqmm to 150 Sqmm x 3.5 Core cross sectional area including testing after jointing as in replacment after disconnecting the cable from Panel / Pole, preparing the for jointing including all earth work,complete all as specified and directed by Engineer-in-Charge.
Supply & fixing of straight through heat shirankable joint including sleeves suitable for LT XPLE underground aluminium conductor cable 1000 Volt of grade 185 Sqmm to 240 Sqmm x 3.5 Core cross sectional area including testing after jointing as in replacment after disconnecting the cable from Panel / Pole, preparing the for jointing including all earth work,complete all as specified and directed by Engineer-in-Charge.
Note : Total amount of Schedule of Credit for retrieved material mentioned on General summary of Tender documents in PDF format will be deducted offline during acceptance of Tender
LUXMI ELECTRONIC WORKS
MOHAN LAL AND SONS
DAVINDER SINGH
proach associates
KARAN TRADERS
PAWAN KUMAR GOVT. CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .