CE SHILLONG ZONE
HQ CE SHILLONG ZONE, SPREAD EAGLE FALLS, SHILLONG, MEGHALAYA
CONSTRUCTION OF KLP ACCN PHASE I AT RANGAPAR UNDER GE 868 EWS
2026_MES_747713_1
89882/RANG/E8
Open Tender
Civil Works
2745 days
Rangapahar
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,000
GE 868 EWS
₹15 L
9 Jan 2026
9 Jan 2026
12 Jun 2026
9 Mar 2026
10 Jun 2026
25 May 2026
NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
PHASE I
Lumpsum price workedout by the tenderer for BUILDING & STRUCTURE WORKS as listed in Schedule ‘A’ Part-I(A)
Schedule ‘A’ Part-I(B)(MINOR BRIDGE WORK) Construction of bridge 35.00 m span with PSC girder including retaining walls, abutments with pile caps, eartnfilling and excavations, approach paths etc complete all as shown on drawings. Note: (i) Boring of pile and cast-in-situ of pile including its concrete and reinforcement shall be measured and paid separately under relevant Schedule. (ii) Cost of pile cap including RCC, reinforcement and form work & its earthwork are included in the quoted amount of bridge.
Lumpsum price workedout by the tenderer for CAST-IN-SITU PILE as listed in Schedule ‘A’ Part-I(C)
Lumpsum price worked out by the bidder/ tenderer for SITE CLEARANCE, DEVELOPMENTS AND EARTH WORKS as listed in Schedule 'A' Part-II.
Lumpsum price worked out by the bidder/ tenderer for INTERNAL WATER SUPPLY as listed in Schedule 'A' Part-III.
Lumpsum price worked out by the bidder/ tenderer for ROAD, PATH AND CULVERT as listed in Schedule 'A' Part-IV.
Lumpsum price worked out by the bidder/ tenderer for SEWAGE DISPOSAL as listed in Schedule 'A' Part-V.
Lumpsum price worked out by the bidder/ tenderer for COMPOUND WALL AND GATE as listed in Schedule 'A' Part-VI.
Lumpsum price worked out by the bidder/ tenderer for AREA DRAINAGE as listed in Schedule 'A' Part-VII.
Lumpsum price worked out by the bidder/ tenderer for RETAINING WALL as listed in Schedule 'A' Part-VIII.
Lumpsum price worked out by the bidder/ tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule 'A' Part-IX.
Lumpsum price worked out by the bidder/ tenderer for AC AND REFRIGERATION as listed in Schedule 'A' Part-X.
Lumpsum price worked out by the bidder/ tenderer for LIFT as listed in Schedule 'A' Part-XI.
Lumpsum price worked out by the bidder/ tenderer for TELEPHONE AND INTERCOM as listed in Schedule 'A' Part-XII.
Lumpsum price worked out by the bidder/ tenderer for ENGAGEMENT LIGHT as listed in Schedule 'A' Part-XIII.
Lumpsum price worked out by the bidder/ tenderer for DG SET as listed in Schedule 'A' Part-XIV.
Lumpsum price worked out by the bidder/ tenderer for EXTERNAL WATER SUPPLY as listed in Schedule 'A' Part-XV.
Lumpsum price worked out by the bidder/ tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule 'A' Part-XVI.
Lumpsum price worked out by the bidder/ tenderer for FIRE ALARM SYSTEM as listed in Schedule 'A' Part-XIV.
Lumpsum price worked out by the bidder/ tenderer for FIRE FIGHTING SYSTEM as listed in Schedule 'A' Part-XVIII.
Lumpsum price worked out by the bidder/ tenderer for DEMOLITION AND DISMANTLING as listed in Schedule 'A' Part-XIX.
Sch 'A' Sec-XX (Miscellaneous Items) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Supply, laying, jointing and testing GI tubing of 65 mm bore, medium grade with and including all medium grade galvanished iron fitting and fixing ISI Marked accessoiries such as Tees, elbows, bend, sockets unions, plugs and sockets, short pieces connector and back nuts, deminishing pieces, cap plugs etc fixed to walls and ceilings or laid in floors complete all as specified and directed
S&F two way bib cock with wall flange quarter turn (Low-Flow) 16 mm dia complete all as specified and directed.
S&F 15 mm bore push cock for urinal for iron pipe complete all as specified and directed.
S&F Gun-metal, globe or gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe of 65 mm bore complete all as specified and directed
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including connections and fixed in position with 1 mtr, flexible pipe 15 mm bore (braided tube) & hook, complete all as specified and directed.
Felling of 151 Nos of tree exc 30 cm girth including cutting of trunk and branches, stacking of all material and taking out from MoD land. The details of trees are as per BOO and pricing done by Divisional Forest Officer as below : No of Trees = 151 Nos Royalty Payable = Rs.36731.00 Amount for timber and firewood = Rs. 352764.00 Total amount = Rs. 389495.00
S&F 2 mm thick translucent corrugated UV stabilized fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts of 8 mm dia complete all as specified and directed.
S&F SFRC Manhole cover complete all as specified and directed.
S&F 150 mm wide PVC Water Bar complete all as specified and directed
S&F Modular type 3 pin 20 A Socket with one No. of MCB single pole conforming to IS 1293 : 2005 as specified in IS 732 : 2019 complete all as specified directed. (for AC & Geyser Point)
S & F of LED low bay light fitting of 40 Watt system wattage, high-quality group control enabled intgrated LED high bay light with a minimum system lumen of min 5600 lm with a nominal system efficacy of 140 lumen/watt. The LED used shall have CCT of 5700K, and CR≥70. The luminaire should be designed for operations under diverse environment from - 10ºC to 50ºC. The luminaire should be beam angle of light source 30º/60º/90º as per requirement. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminium, to withstand extreme environments. The spigot shall be part of "Single Piece Pressure Die-cast housing" & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. The luminaire LED shall have declared Lifetime of 50 Khrs (L70B5O @ Ta 45ºC). The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP65 & impact resistance shall be IK08. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 6KA SPD duly bolted in the Luminaire. The LED used in the luminaire shall be SMD type only & shall be from either Lumineds, Osram, Nichia, Cree & APT Electronics make or equivalent. The Driver should be asphalt potted & should be a BIS approved driver.
Continued Serial item No. 20.012 The driver shall have operating voltage of 120V to 270V, PF≥0.95 @ full load, THD≤10% @ full load, Current ripple <10%. The driver should be capable of withstand voltage stress of 440V for 8 hrs., should have an auto shutdown @ 325V (±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2. The luminaire driver & it's SPD shall be of the same make / manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with sample approval. The LED Luminaire & it's driver both should be BIS registered. The contractor shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete all as specified and directed.
Supply, Installation, testing & commissioning of LED Engagement light fitting (Red & Green), 220 V, luminaire made of CRCA housing and PC diffuser (Diffuser-Non yellowing type). The luminaire should have a LEDs with colour consistency SDCM ≤ 5, CRI ≥ 80 and CCT of 6500K. Luminaire shall be designed system lumens at a system efficacy of at-least 100 lumen/watt. Power consumption should not be more than 10W (± 5%). The Life of fixture (Including Driver):50000 burning Hrs. @ L70B50 Lumen maintenance @ design ambient temp 45 deg C. The electronic driver used shall have a power factor 0.95 and THD ≤10%, suitable for an operating voltage range of 140-270V AC, Current Ripple ≤ 5%, Internal surge protection should be minimum 2 KV, electrical insulation class should be Class I & driver should be of Class B serviceability. The luminaire shall be IP20 & IK02 compliant. The luminaire driver shall be of the same make / manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The Contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it's driver both should be BIS registered. Contractor shall submit the following reports before supply of material for approvals LM79 issued by NABL accrediated lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accrediate lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete all as specified and directed.
S&F Surge Protection Device (SPD) single phase and neutral, T2 -limb, Imax 20 KA per pole fixed in distribution board and making connections complete all as specified and directed
S&F Surge Protection Device (SPD) Three phase and neutral, T2 -limb, Imax 20 KA per pole fixed in distribution board and making connections complete all as specified and directed
S&F Modular Telephone socket RJ 11 suitable for housing modular frame plate complete all as specified and directed
S&F modular type TV socket. RJ46, 1 module complete all as specified and directed.
Supply, Installation, Testing and Commissioning of White LED strip light IP68, CB and CE certified sealed with anti-UV polyurethane along with accessories such as driver, mounting clips, connectors, etc. as required for straight or curved surfaces and recessed applications with housing of Extruded silicone, wattage not exceeding 65W/ 5 M with lumen output of not less than 5000/ 5 M . Luminaire has a choice of beam angles of 120° degree. Fixture should run on input voltage of 24VDC. Lifetime should be at least 30000 burning hours at L50 at 25 degree centigrade with total IP66 protection should be provided. Controlled through DMX/Ethernet protocol complete all as specified and directed Note : [i] Luminaire uminaire should be BIS certified and [ii] CRS No. for both luminaire and driver along with LM79 report from NABL accrediated LAB should be submitted.
Supply, Installation, testing and commissioning of exterior rated LED linear luminaire of 1000mm with dedicated optics for architectural lighting. Beam angles option of A11: 20x30° Beam Angle deg Beam Angle . Wattage of 15W 24V DC powered and should be able to produce light by LED Channels of 3000K and DMX 512 based controller. The luminaire should have Electrostatically applied polyester powder coating die cast AL housing and clear tempered glass and Anti-aging and anti-UV high optical efficiency PMMA lenses. The system lumen should be more than 985 lm full light output. The luminaire can be connected to direct AC mains connection via junction box. The operating voltage range is 220-240V AC, 50Hz. The luminaire should be IP 66 and IK 06 type luminaire. Operating temperature from 0 to 50 deg Centigrade, Class I electrical insulation, with CRI>=80. Lumen maintenance of at least L70 @ 50000 hours at 35 degree complete all as specified and directed Notes : [i] Maximum weight of the luminaire should be 2.5kgs. [ii] Luminaire should be BIS certified.
Supply, Installation, testing and commissioning of Extruded aluminum with die-cast aluminum end caps Electrostatically applied polyester powder coating Dark Grey (RAL7012) modular, rectangular shaped exterior rated LED floodlighting luminaire with dedicated optics for architectural lighting. Beam angles of 3°, 10°, 30°, 45°, 60°. Wattage of 300W and should be able to produce light by LED Channels RGBNW (4000K) and DMX 512 based controller. The luminaire should have Electrostatically applied polyester powder coating die cast AL housing and clear tempered glass and Anti-aging and anti-UV high optical efficiency PMMA lenses. The system lumen should be more than 15000 lm full light output. The luminaire can be connected to direct AC mains connection via junction box. The operating voltage range is 220-240V AC, 50Hz. The luminaire should be IP 66 and IK 06 type luminaire. Operating temperature from 0 to 50 deg Centigrade, Class I electrical insulation, with CRI>=80. Lumen maintenance of at least L50 @ 50000 hours at 35 degree complete all as specified and directed Note : [i] Maximum weight of the luminaire should be 16kgs. [ii] Luminaire should be BIS certified.
Supply, Installation, testing and commissioning of exterior rated LED linear luminaire of 1000mm with dedicated optics for architectural lighting. Beam angles option of 16x 35 deg 25x40°, 30°, 40°, 50°. Wattage of 36W and should be able to produce light by LED Channels of RGBNW (4000K, neutral white) and DMX 512 based controller. The luminaire should have Electrostatically applied polyester powder coating die cast AL housing and clear tempered glass and Anti-aging and anti-UV high optical efficiency PMMA lenses. The system lumen should be more than 1200 lm full light output. The luminaire can be connected to direct AC mains connection via junction box. The operating voltage range is 220-240V AC, 50Hz. The luminaire should be IP 66 and IK 06 type luminaire. Operating temperature from 0 to 50 deg Centigrade, Class I electrical insulation, with CRI>=80. Lumen maintenance of at least L70 @ 50000 hours at 35 degree complete all as specified and directed Note : [i] Maximum weight of the luminaire should be 4.0 kgs. [ii] Luminaire should be BIS certified.
Supply, Installation, testing and commissioning of Extruded aluminum with die-cast aluminum end caps Electrostatically applied polyester powder coating Dark Grey (RAL7012) modular, rectangular shaped exterior rated LED floodlighting luminaire with dedicated optics for architectural lighting. Beam angles of 10°,30,° 45°, 60°. Wattage of 150W and should be able to produce light by LED Channels RGBNW (4000K) and DMX 512 based controller. The luminaire should have Electrostatically applied polyester powder coating die cast AL housing and clear tempered glass and Anti-aging and anti-UV high optical efficiency PMMA lenses. The system lumen should be more than 7500 lm full light output. The luminaire can be connected to direct AC mains connection via junction box. The operating voltage range is 220-240V AC, 50Hz. The luminaire should be IP 66 and IK 06 type luminaire. Operating temperature from 0 to 50 deg Centigrade, Class I electrical insulation, with CRI>=80. Lumen maintenance of at least L50 @ 50000 hours at 35 degree complete all as specified and directed Note : [i] Maximum weight of the luminaire should be 7.5 kgs. [ii] Luminaire should be BIS certified.
Supply, Installation, testing and commissioning of Extruded aluminum with die-cast aluminum end caps Electrostatically applied polyester powder coating Dark Grey (RAL7012) modular, rectangular shaped exterior rated LED floodlighting luminaire with dedicated optics for architectural lighting. Beam angles of 3 Deg Wattage of 100W and should be able to produce light by LED Channels RGBNW (4000K) and DMX 512 based controller. The luminaire should have Electrostatically applied polyester powder coating die cast AL housing and clear tempered glass and Anti-aging and anti-UV high optical efficiency PMMA lenses. The system lumen should be more than 7500 lm full light output. The luminaire can be connected to direct AC mains connection via junction box. The operating voltage range is 220-240V AC, 50Hz. The luminaire should be IP 66 and IK 06 type luminaire. Operating temperature from 0 to 50 deg Centigrade, Class I electrical insulation, with CRI>=80. Lumen maintenance of at least L50 @ 50000 hours at 35 degree complete all as specified and directed Note : [i] Maximum weight of the luminaire should be 7.5 kgs. [ii] Luminaire should be BIS certified.
Supply, Installation, Testing and Commissioning of intelligent and compact master DMX controller that is developed for small and medium sized applications. It can control up to 8 DMX512 universes, playback scenes and animations stored in its SD card and it can be used for offline scenes scheduling, setting brightness, white balance and playback speed adjustments complete all as specified and directed
Supply, Installation, Testing and Commissioning of ethernet switch with all accessories for Façade lighting system complete all as specified and directed
Supply, Installation, Testing and Commissioning of ethernet based Stand-alone wall-mounted controller that triggers up to six shows at the touch of a button that Supports 10/100 Mbps full- or half-duplex from any PoE- or IEEE 802.3af-compliant Ethernet switch. PoE injector required for use with non-IEEE 802.3af-compliant switches; maximum 3W, made up of Medium matte white plastic enclosure; suitable for RJ45 Port, shielded Cat. 5e or better data cable; IP20, operating from -5ºC to 50ºC, 0 – 90%, non-condensing complete all as specified and directed
Supply, installation, testing and commissioning of Surface / Dinrail mountable DMX Spilitter and booster device suppoting bidirectional communication for discovery,addresing and control of DMX enabled light fixtures. Device should be capable of taking incoming DMX/RDM signal and splits the signal into six separate output channels.The output terminals should be electronically isolated from the input & RDM-through port and should share a common ground reference. All six output ports should have an independent output driver to boost the DMX/RDM signal.Maximum Power Consumption of device should be 4.5W complete all as specified and directed
Supply, Installation, Testing and Commissioning of Programming and commissioning of Facade lighting system with all necessary hardware and softwares complete as per design approved by Accepting Officer complete all as specified and directed
Supply, Installation, Testing and Commissioning of JV BOX Voltage Stabilizer DMX Power Cable with all accessories as required for complete operation of Façade lighting system complete all as specified and directed
VRF OUTDOOR UNIT Supply, installation, testing and commissioning of following VRF / VRV outdoor units, having R410A / R407C refrigerant, multiple Nos. of inverter, digital scroll compressors, air cooled condenser fan with motor, microprocessor control panel, starter controls for all scroll compressors and condenser fan motors along with internal control and power wiring, cooling coil with internally interconnected refrigerant pipes for interconnecting various capacity modules, charging port and all other required accessories, & hardware, first charge of refrigerant and all other required accessories, hardware like T joints etc., all enclosed in an enclosure with weather resistant powder coating paint for withstanding all ambient conditions for continuous outdoor operation, suitable to operate on 3-Phase, 380-415 V, 50 Hz AC power supply complete all as specified and directed NOTES: [i] The VRF/ VRV system shall be provided with mounting base and antivibration pad(s). All the accessories, hardware, software, consumables etc. whether specifically mentioned or not but required to put the VRF / VRV System into service up to the satisfaction of the Engineer-in-charge including testing, commissioning as per specifications, site constraints shall be deemed included in the scope of the work. [ii] Nothing extra shall be payable for these systems under any circumstances. All the consumables including first charge of refrigerant (R410A / R407C) and oil for the proposed VRF / VRV system shall be deemed inclusive in the scope of work. The topping of refrigerant and oil shall also be included in the scope of work for arresting leakages if any. The unit shall be lifted using crane / sufficient manpower and installed on suitable pedestal / MS rail / bots & nuts etc, all complete as requirement of site conditions.
(a) VRF / VRV outdoor units of min. 18 HP combined heating + cooling capacity at site conditions
(b) VRF / VRV outdoor units of min. 20 HP combined heating + cooling capacity at site conditions
REFRIGERANT COPPER PIPING Supply, installation, testing and commissioning of refrigerant copper piping (duly insulated with 19 mm thick closed cell elastomeric nitrile rubber tubular insulation) of hard drawn / soft drawn copper pipe, laid on walls / roof / ceiling well supported at specific intervals with metallic supports and screwed with anchor fasteners and necessary accessories, jointing / brazing etc., including connection between outdoor unit to indoor units as required complete all as specified and directed NOTES: [i] The sizing of refrigerant copper piping shall be confirmed / vetted by the OEM. [ii] All piping inside the ceiling shall be properly supported using necessary clamps and all externals refrigerant lines shall be properly protected using necessary PVC (HDPE) pipes with accessories to suit the site conditions. [iii] The quantity of these items of works shall be measured as per actuals requirements of site conditions. The vendor shall accept the accepted rate as per the actual measured quantities.
(a) 5/8" (15.9 mm) (Liquid)
(b) 1 1/8" (28.6 mm) (Gas)
Supply, installation, testing and commissioning of variable refrigerant flow distribution Ref-nets joint (Y-joint) in the gas and liquid lines for outdoor unit complete all as specified and directed
M&L for 25 / 32 / 40 mm dia .PVC drain water pipe including bends, collars & elbow etc, and duly insulated with 9 mm thick tubular insulation of closed cell elastomeric nitrile rubber as required complete all as specified and directed.
M&L for square / rectangular / round neck 525 mm X 525 mm rectangular neck 4-way discharge ceiling supply diffuser having neck velocity ≤ 600 ft/min, throw ≥ 26' @ 150 ft/min velocity NC ≤ 37 for air flow ≥ 1450 ft3/min ceiling Supply diffuser for fixed, horizontal discharge pattern consisting of an outer frame assembly with a square / rectangular inlet being an integral part thereof, an inner core assembly consisting of fixed deflection louvers, heavy gauge steel volume control damper operable from the face of the diffuser by removing the spring-loaded inner core assembly, throw reducing vanes, anodic acrylic paint finish, etc. and tested as per ANSI / ASHRAE standard 170-1991 complete all as specified and directed (AIR TERMINAL)
M&L for square / rectangular / round neck 450 mm X 450 mm rectangular neck 4-way discharge ceiling supply diffuser having neck velocity ≤ 600 ft/min, throw ≥ 26' @ 150 ft/min velocity NC ≤ 37 for air flow ≥ 1450 ft3/min ceiling Supply diffuser for fixed, horizontal discharge pattern consisting of an outer frame assembly with a square / rectangular inlet being an integral part thereof, an inner core assembly consisting of fixed deflection louvers, heavy gauge steel volume control damper operable from the face of the diffuser by removing the spring-loaded inner core assembly, throw reducing vanes, anodic acrylic paint finish, etc. and tested as per ANSI / ASHRAE standard 170-1991 complete all as specified and directed
M&L for square / rectangular / round neck 375 mm X 375 mm rectangular neck 4-way discharge ceiling supply diffuser having neck velocity ≤ 600 ft/min, throw ≥ 26' @ 150 ft/min velocity NC ≤ 37 for air flow ≥ 1450 ft3/min ceiling Supply diffuser for fixed, horizontal discharge pattern consisting of an outer frame assembly with a square / rectangular inlet being an integral part thereof, an inner core assembly consisting of fixed deflection louvers, heavy gauge steel volume control damper operable from the face of the diffuser by removing the spring-loaded inner core assembly, throw reducing vanes, anodic acrylic paint finish, etc. and tested as per ANSI / ASHRAE standard 170-1991 complete all as specified and directed
M & L for square / rectangular / round neck 300 mm X 300 mm rectangular neck 4-way discharge ceiling supply diffuser having neck velocity ≤ 600 ft/min, throw ≥ 26' @ 150 ft/min velocity NC ≤ 37 for air flow ≥ 1450 ft3/min ceiling Supply diffuser for fixed, horizontal discharge pattern consisting of an outer frame assembly with a square / rectangular inlet being an integral part thereof, an inner core assembly consisting of fixed deflection louvers, heavy gauge steel volume control damper operable from the face of the diffuser by removing the spring-loaded inner core assembly, throw reducing vanes, anodic acrylic paint finish, etc. and tested as per ANSI / ASHRAE standard 170-1991 complete all as specified and directed
M&L for square neck 525 mm X 525 mm rectangular neck 4-way discharge ceiling return diffuser @ 150 ft/min velocity NC ≤ 25 for air flow ≥ 830 ft3/min ceiling return diffuser for fixed, horizontal discharge pattern consisting of an outer frame assembly with a square / rectangular inlet being an integral part thereof, an inner core assembly consisting of fixed deflection louvers, throw reducing vanes, anodic acrylic paint finish, etc. and tested as per ANSI / ASHRAE standard 170-1991 complete all as specified and directed
M&L for square neck 450 mm X 450 mm rectangular neck 4-way discharge ceiling return diffuser @ 150 ft/min velocity NC ≤ 25 for air flow ≥ 830 ft3/min ceiling return diffuser for fixed, horizontal discharge pattern consisting of an outer frame assembly with a square / rectangular inlet being an integral part thereof, an inner core assembly consisting of fixed deflection louvers, throw reducing vanes, anodic acrylic paint finish, etc. and tested as per ANSI / ASHRAE standard 170-1991 complete all as specified and directed
M&L for square neck 375 mm X 375 mm rectangular neck 4-way discharge ceiling return diffuser @ 150 ft/min velocity NC ≤ 25 for air flow ≥ 830 ft3/min ceiling return diffuser for fixed, horizontal discharge pattern consisting of an outer frame assembly with a square / rectangular inlet being an integral part thereof, an inner core assembly consisting of fixed deflection louvers, throw reducing vanes, anodic acrylic paint finish, etc. and tested as per ANSI / ASHRAE standard 170-1991 complete all as specified and directed
M&L for square neck 300 mm X 300 mm rectangular neck 4-way discharge ceiling return diffuser @ 150 ft/min velocity NC ≤ 25 for air flow ≥ 830 ft3/min ceiling return diffuser for fixed, horizontal discharge pattern consisting of an outer frame assembly with a square / rectangular inlet being an integral part thereof, an inner core assembly consisting of fixed deflection louvers, throw reducing vanes, anodic acrylic paint finish, etc. and tested as per ANSI / ASHRAE standard 170-1991 complete all as specified and directed
M&L for CBRI certified 16-gauge GI fire damper, at least of 120 minutes fire-rating, spring activated on melting of fusible link having melting point 67.13° C complete with smoke detector / thermistor, fusible link etc. and actuator as required for operation, located in the SA / RA ducts, at all fire rated crossovers (shafts, walls, etc.) along with control panel (located in such a way that the reset may easily be done), interlocked with the building management system for the fire detection or HVAC to trip / close in the event of fire / smoke in the respective zone and tested as per UL-555 complete all as specified and directed The fire dampers shall meet the following criteriaon: [i] Bare fire dampers with 400 mm sleeve [ii] Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position [iii] Interconnection wire for the fire detection & alarm system with the AHU and the smoke dampers [iv] Sealing any openings around the sleeve of the fire dampers with approved fire sealant as per the specification & recommandations of the manufacturer.
(a) Motorized, spring return type, combination fire and smoke damper
(b) Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position.
Supply, installation, testing and commissioning of high performance airfoil class 1A leakage rated GI volume control damper having galvanised steel hat channel frame reinforced with corner braces, galvanised steel airfoil shaped blades (double skin construction) of 14 gauge thicknes, neoprene blade edge seals, flexible metal compressible jamb seals, stainless steel sleeve, linkage concealed in frame, etc. tested as per AMCA Standard 500-D-98 complete all as specified and directed
S & F of FM approved flexible pre-covered self-extinguishing thermal insulation made of flexible insulation foam based on synthetic rubber with polymeric covering reinforced with polyester scrim, for insulation of air conditioning ductwork both indoor and outdoor conditions to prevent condensation, reduce energy losses, prevent scratches, mechanical damage and frost on pipes, tested for maximum +85 ᵒC & minimum 0 ᵒC service temperature in conformance with EN 14706, EN 14707 & EN 14304; tear strength > 38 kN/m & tensile strength > 1.5 MPa in conformance with DIN ISO 34-1 & DIN EN ISO 1978; thermal conductivity (λ) ≤ 0.035 W/mK @ 0 ᵒC, ≤ 0.037 W/mK @ 24 ᵒC & ≤ 0.039 W/mK @ 40 ᵒC temperature in conformance with EN 12667 & EN ISO 8497; water vapour diffusion (μ) ≥ 7000 in conformance with EN 12086 & EN 13469; water absorption by volume ≤ 0.2% in conformance with ASTM C 1763; Class O with dura fire performance in conformance with BS 476 Part 6: 1989; Class 1 surface spread of flame in conformance with BS 476 Part 7: 1997; HB, V-0 flammability in conformance with UL-94; UV & moisture in conformance with EN ISO 4892-2 method A & B and having zero ozone depletion potential & zero global warming potential, no risk of galvanic corrosion, good UV resistance, good resistance to mechanical impact, etc., in pre-covered self-adhesive sheets with self-seal and other necessary accessories complete all as specified and directed
(a) 19 mm thick thermal insulation (for supply air ducting)
(b) 13 mm thick thermal insulation (for return air ducting)
Supply, install, testing and commissioning of Variable Air Volume (VAV) unit to match duct size with pressure independent (AHRI certified) with cross flow sensor of amplification factor 2 to 3 for accurate measurement with pressure signals, consisting of BACnet/MSTP communicable DDC controller (fully controllable BTL certified) damper actuator, low pressure velocity transducer and temperature sensor (with digital room thermostat), VAV shall be dynamically calibrated and tested in factory on live test bed as per 500-1000 CFM, each unit shall be supplied with LCD display room thermostatic controller with 10mtr suitable communicable wire complete all as specified and directed.
Supply, install, testing and commissioning of Variable Air Volume (VAV) unit to match duct size with pressure independent (AHRI certified) with cross flow sensor of amplification factor 2 to 3 for accurate measurement with pressure signals, consisting of BACnet/MSTP communicable DDC controller (fully controllable BTL certified) damper actuator, low pressure velocity transducer and temperature sensor (with digital room thermostat), VAV shall be dynamically calibrated and tested in factory on live test bed as per 1000-1300 CFM, each unit shall be supplied with LCD display room thermostatic controller with 10mtr suitable communicable wire complete all as specified and directed.
Supply, install, testing and commissioning of Variable Air Volume (VAV) unit to match duct size with pressure independent (AHRI certified) with cross flow sensor of amplification factor 2 to 3 for accurate measurement with pressure signals, consisting of BACnet/MSTP communicable DDC controller (fully controllable BTL certified) damper actuator, low pressure velocity transducer and temperature sensor (with digital room thermostat), VAV shall be dynamically calibrated and tested in factory on live test bed as per 1300-1800 CFM, each unit shall be supplied with LCD display room thermostatic controller with 10mtr suitable communicable wire complete all as specified and directed.
Supply, install, testing and commissioning of Variable Air Volume (VAV) unit to match duct size with pressure independent (AHRI certified) with cross flow sensor of amplification factor 2 to 3 for accurate measurement with pressure signals, consisting of BACnet/MSTP communicable DDC controller (fully controllable BTL certified) damper actuator, low pressure velocity transducer and temperature sensor (with digital room thermostat), VAV shall be dynamically calibrated and tested in factory on live test bed as per 2000-2600 CFM, each unit shall be supplied with LCD display room thermostatic controller with 10mtr suitable communicable wire complete all as specified and directed.
Supply and installation of refrigerator, electric driven (single phase), capacity 195 Litres, BEE 5 star rated complete all as specified and directed.
Supply, install, testing and commissioning of voltage stablizer for automatic operation, single phase, naturally air cooled, indoor type, designed for input variation between 170V to 250V with stablized output voltage at 230V with accuracy of ±2.5% and of capacity 1.0 kVA complete all as specified and directed.
Supply, install, testing and commissioning of voltage stablizer for automatic operation, single phase, naturally air cooled, indoor type, designed for input variation between 170V to 250V with stablized output voltage at 230V with accuracy of ±2.5% and of capacity 0.50 kVA complete all as specified and directed.
Supply, Install, Testing and commissioning of a remote annunciator / Repeater Panel with supervised wireless link to the FACP, showing Alarm / Supervisory / Fault with zone / device text. Polling interval ≤10s; loss-of-comms trouble ≤60s. Back - lit LCD, LEDSs (Alarm, Supervisory, Fault, Power, Link), internal buzzer (≥75 dB @ 1 m) with silence key as permitted. Power 230 V AC with charger and batteries sized for ≥ 24 h standby + 30 min alarm. Enclosure IP54 for indoor brigade room. Provide mounting hardware, pairing, signal survey, labels, and commissioning records complete all as specified and directed. (to be placed at Fire Station / Guard Room)
S&F Data line Surge Protection Device (SPD) suitable for RS-485, two stage, replaceable Modules, single phase and neutral, T2 -limb, Imax 20 KA per pole complete fixed in FACP & Repeater Panel and making connections complete all as specified and directed
Supply, installation, testing and commissioning of UL listed (fire fighter's) addressable Telephone Jack mounted to a single - gang electrical back box with suitable interface module for two way communication with the Central Fire Fighter Telephone Console complete as specified and directed
Supply, installation, testing and commissioning of UL listed Fire Fighters Telephone Handset for two way communication with the Central Fire Fighter Telephone Console complete as specified and directed
M & L for transparent FR PVC insulated, twin core copper conductor flexible Speaker Cable haivng stranded annealed tinned copper conductor, PVC insulated cores twisted to form pairs, shielded for interference rejection, unarmoured PVC sheathed 1.1 kV grade in conductor size 2 X 1.0 mm² including laying, termination and ferruling complete as specified and directed
S&F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure COշ gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. ccomplete as specified and directed
S&F 4.5 kg light-weight squeeze grip COշ type fire extinguisher, conforming to IS 15683: 2006, with COշ gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed
Supply, Installation Testing & Commissioning of Autimatic fire extinguishers - ceiling mounted clean agent (HFC236fa) capacity of agent 6 Kg, filling tolerance by mass 6-5%, Certification Standard - PED BSU Tested, Dia of Shell - 240mm, Total Height with base (Approx) -341mm, MOC or Shell - Steel CR2 , Test Pressure- 35 Bar, Service Pressure - 10 Bar, Type of operation - Automatic, Type of Pressure Gauge - Magnetic Bourdon tube type, Min Discharge time - 4 to 9 Sec, Operating temp range -30 ºC to +60 ºC complete all as specified and directed. (to be placed at Utility Room & Telephone Exchange)
S&F the following type of Signages made out of 3 mm thick opaque PVC foam board with computer cut. PVC non - reflective self adhesive vinyl painted foarm board, complete with mirror fasteners complete as specified and directed
(a) Signage having size 300 mm X 150 mm reading "EXIT" in 12.5 mm block letters in Green and white background, self illuminated properly spaced to provide good legibility located directly in corridor near to each staircase and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level.These lights shall emit the maximum light required even during the electricity supply or in Black out period with high energy efficiency manufactured using superior quality Aluminium Extrusion body raw material complete as specified and directed
(b) Signage having size 500 mm X 500 mm, indicating the "Floor Number" in bold type and at 75 mm high numerals in red and white background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non - reflective self adhesive vinyle painted foam board, posted and maintained within each stair enclosure on every floor, securely attached to the stair side of the door in a way that the bottom of the sign is not above 1.5 m from the finished floor level complete as specified and directed
(c) Signage having size of 450 MM X 150 MM reading "FIRE EXTINGUISHER" in 12.5 mm block letters in White and Red background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non - reflective self adhesive vinyle painted foam board, properly spaced to provide good legibility located directly in corridor near to each Manual call point/Fire Extinguisher and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level complete as specified and directed
(d) Signage having size of 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the "STAIRCASE" by an alphabetical letter in bold type and at 75 mm high letters in red and white background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board,securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level complete as specified and directed
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor, cubical compartmental type "Motor Control Center" (MCC) of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 54 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed. The MCC shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of Aluminimum / Copper busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] Circuit Breaker (a) 250 A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz, FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload) - 01 No.
Serial item No. 20.062 continued... [iii] Necessary control and switching devices to execute the switching and control logic shall be deemed inclusive of the scope of supply irrespective of them being specified/not specified above or in the SLD. [iv] The Panel / Switchboard shall be tested to withstand vibration caused by an earthquake in accordance with IEC 60068-3-3:2013 or IS 1893 Zone V. [v] The Panel shall be purchased from the original equipment manufacturer (OEM) authorised franchises only. [vi] All the necessary noble components (viz., structural, Door noble like hinge, Bush, Door alignment guage and Bus bar noble - Bus bar support, Close profile structure - horizontal & vertical) of the Panel shall be supplied by the OEM. [vii] The Contractor shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerances, typical GADs, etc. to the engineer-in-charge for approval of the MEP Consultant and thereafter A.O./representative. [viii] The Contractor shall intimate the Engineer-in-charge of the routine tests in the OEM factory in presence of a representative nominated by the Engineer-in-Charge before dispatch.
M&L for low smoke zero halogen (LSZH) fire survival control cable with circuit integrity conforming to BS 7846 and rated for 600 V, having plain annealed stranded copper conductor with fire - resistant mica tapes covered by an extruded layer of cross - linked polyethylene, extruded layer of thermoplastic low smoke zero halogen (LSZH) compound. single layer of galvanized steel wires and thermoplastic (LSZH) compound sheath, suitable for operating temperature range -40ºC to +90ºC and minimum bending radius being 12 times the overall cable diameter, including laying, clamping, termination and ferruling complete as specified and directed .
(a) 2 core, 2.5 mm² (for instrumentation)
(b) 3 core, 2.5 mm² (for auto start/stop panel)
(c) 12 core, 2.5 mm² (for diesel engine pump)
M&L for 1.1 kV grade fire survival cable with fire rating FS (950/FWS) conforming to IS17505-1: 2021, and having electrolytic annealed plain / tinned copper (Class 1/2) conductor conforming to IS 8130: 2013, mica tape layer (s) primary insulation, cross linked PE (XLPE) / cross linked HFFR secondary insulation, thermoplastic HFFR inner sheath, glass fibre heat barrier tape, galvanized round wire armour, thermoplastic HFFR (HFS-TP 90) / Cross Linked HFFR (HSF-XL 90) outer sheath including necessary clamping / dressing with cable ties and termination complete as all specified and directed
(a) 3 core, 35 mm² FS (950 / FWS) Cable
(b) 3 core, 4 mm² FS (950 / FWS) Cable
S&F perforated hot dipped galvanized iron Cable tray of size 300 mm x 50 mm x 1.60 mm having galvanization thickness not less than 50 microns and perforation not more than 17.5% including fittings viz, joints, bends, tees, etc, in convenient sections of length complete including cable tray supports and associated accessories complete all as specified and directed.
S&F perforated hot dipped galvanized iron Cable tray of size 150 mm x 50 mm x 1.60 mm having galvanization thickness not less than 50 microns and perforation not more than 17.5% including fittings viz, joints, bends, tees, etc, in convenient sections of length complete including cable tray supports and associated accessories complete all as specified and directed.
S&F perforated hot dipped galvanized iron Cable tray of size 100 mm x 50 mm x 1.60 mm having galvanization thickness not less than 50 microns and perforation not more than 17.5% including fittings viz, joints, bends, tees, etc, in convenient sections of length complete including cable tray supports and associated accessories complete all as specified and directed.
M&L for PN 1.6 rated 200 mm NB polypropylene Vortex inhibitor suction lift, conforming to BS 4504 with stainless wire mesh, bolts, nuts and washers, etc. complete all as specified and directed
S&F 25 mm dia Ball Valve, designed & manufactured as per IS:9890 (1981) and tested as per BS 6755 Part - I, having floating type three piece design, CS body, SS-304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed.
S&F 40 mm dia Ball Valve, designed & manufactured as per IS:9890 (1981) and tested as per BS 6755 Part - I, having floating type three piece design, CS body, SS-304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed.
S&F 80 mm dia Ball Valve, designed & manufactured as per IS:9890 (1981) and tested as per BS 6755 Part - I, having floating type three piece design, CS body, SS-304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed.
M&L for FM approved and UL listed 25 mm NB compact 3 position ball valve with drain orifice (Test and drain valve) to test and drain water flow through sprinkler systems having OFF-TEST-DRAIN position, integral sight glass, rated pressure 300 psi, orifice size 15 mm and K factor 5.6, conforming to NFPA 13, along with necessary accessories complete as specified and directed
S&F orirface plate made out of 6 mm thick SS 304 with oriface of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm³ complete as specified and directed
Supply, installation, testing and commissioning of automatic Air-vent valve with 20 mm end connections, brass body and cover, plastic float, brass cap etc. suitable for maximum operating pressure of 16 bar and maximum operating temperature 100° C respectively, installed on all high points in the water piping system to automatically remove the trapped air complete all as specified and directed.
S&F modular telephone / computer socket (RJ-11) with MS box, inner plate and outer plate complete all as specified and directed.
Supply, installation, Testing and commissioning of 8 mm Aluminum Round Conductor as specified in drawing and meets the requirements along with necessary accessories as recommended by OEM / Manufacturer complete all as specified and directed
Supply, installation, Testing and commissioning of Polyamide Roof conductor holder for fixing of aluminium conductor on parapet with M8 female thread or diameter 7mm, M8 Screw having weather and temperature withstand resistant from -35 to +90 degree Celsius tested, by fixing holder @ 1 meter distance along with necessary accessories as recommended by OEM / Manufacturer complete all as specified and directed
Supply, installation, Testing and commissioning of Polyamide roof cable holder for flat roof conforming DIN:48829 form B1 closed form with bottom, filling weight 1 Kg (frost resisant concrete), sleeve from polyethylene, black. Conductor holder @ 1 meter distance along with necessary accessories as recommended by OEM / Manufacturer complete all as specified and directed
Supply, installation, Testing and commissioning of 3 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305 part-3 Nominal size Ø 10/16 mm aluminium rod, semi hard (E-AlMgSiO5 corresponds to DIN 48801) suitable to withstand high wind load complete with necessary accessories as recommended by OEM / Manufacturer complete all as specified and directed
Supply, installation, Testing and commissioning of wall fixing cross bar clamp for conductor upto 16mm dia using hot dip galvanised steel complete with necessary accessories as recommended by OEM / Manufacturer complete all as specified and directed
Supply and fixing alumiium conductor 8mm dia conductor with air termination rod upto 16mm with complete accessories as recommended by OEM / Manufacturer complete all as specified and directed
Supply, installation, Testing and commissioning of cross universal connector for T cross & parallel connections to route vertical down conductor / mesh formation using hexagonal bolt M10X30 of hot dipped galvanised iron etc as required conforms to the requirements according to IS-IEC 62305 complete as recommended by OEM / Manufacturer all as specified and directed
Supply, installation, Testing and commissioning of cross universal connector for T cross & parallel connections with expansion joint 02 Nos per joint using hexagonal bolt M10X30 of hot dipped galvanised iron etc as required conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305) complete as recommended by OEM / Manufacturer all as specified and directed
Supply, installation, Testing and commissioning of expansion piece with connector for equalising temperature related length changes, in the conductors at every 20 meters length for round conductor 8mm rod along with necessary accessories as recommended by OEM / Manufacturer complete all as specified and directed
Supply, installation, Testing and commissioning of Copper coated round conductor 10mm dia with 100 micron copper coating along with necessary accessories as recommended by OEM / Manufacturer complete all as specified and directed
Supply, installation, Testing and commissioning of Copper coated round conductor 10mm dia with 100 micron copper coating along with necessary accessories for Vertical Column Riser as specified in drawing & Meets the requirements of IS/IEC 62305 complete all as specified and directed.
Supply of clamp for connection with reinforced steel of diameter 16-40mm and with 8mm dia conductor with all fixing accessories as specified in drawing & meets the requirements of OEM standards complete all as specified and directed.
Supply, installation, Testing and commissioning of connectors for T cross and parallel connections with hexagonal bolt M10X30 high-grade hot dip galvanised according to DIN VDE 0185-305 (IS-IEC 62305) along with necessary accessories as recommended by OEM / Manufacturer complete all as specified and directed
Supply, installation, Testing and commissioning of earth fixed point, made of Stainless Steel grade 316L, connection to earthing systems, air terminals and reinforcement using contact plate of 79 mm diameter, made of rustproof stainless steel (V4A), clamping bolt 10mm diameter, rustproof (V2A), with plastic cover complete all as specified and directed
Supply, installation, Testing and commissioning ofconnector with 8−10 mm with pressure trough with 1 fix contact clamping screw, nut and serrated washer including pre-mounted pressure sump, steel conforms to the requirements according to IEC 62305 complete all as specified and directed.
S&F LED 0.50 Watt green lamp complete all as specified and directed.
S&F LED 0.50 Watt red lamp complete all as specified and directed.
Supply, Installation, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 250 kVA (200 kW), 415 Volts (AC three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Rangapahar (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features conforming to IS 10002: 1981 and latest CPCB-IV+ guidelines and comprising of followings:- (i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection, 3 cylinders, four stroke, radiator cooled, performance class of generator set ISO 8528-5 G2, turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 250 kVA (200 kW) at outdoor atmospheric conditions at Rangapahar, (Taking all derating factor into consideration), 12/24 Volt (as per manufacturer recommendations) electric battery start incl suitable size battery, complete withy fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc .
Serial item No. 20.093 continued.... Testing : (i) All routine test certificates from the manufacturer in respect of the diesel engine, alternator and the control panel will be made available by the contractor. (ii) The Generating set shall be run for a period of 12 hours, of which at least 6 hours shall be at the rated load and for a period of one hour at 10% over load in above 12 hours running. (iii) All instruments, equipments, materials including DHPP and Engine oil and labour required for testing will be made available by contractor at his own cost and unit rate in Sch 'A' will be deemed to be included for testing to the entire satisfaction of Engr-in-Charge :- (a) Insulation resistance test on the alternator and control panel. (b) High voltage test as per BS-2613 clause 33 on the alternator when still hot. (c) Efficiency test at rated load and over load. (d) Testing of sound level should carried out at the site in presence of Engineer-in-Charge (e) All test as described above under testing clause shall be carried out in presence of officer nominated by accepting officer.
All as per serial item No. 20.093 above but for 160 KVA (128 KW) capacity of DG Set.
M&L for Cutting existing DI pipe 250mm dia for insertion of reducer DI Tee, size 250x250x100mm including all alterations or additions, fittings and jointing materials complete all as specified and directed.
Supply, install, testing & commissioning of Air release valve, Cast iron, double air outlet, flanged ends, 100 mm connected to 100mm dia main line, ISI marked conforming to IS 14845 including making new flanged joints with 3 mm thick rubber gasket with necessary bolts, nuts, washer etc of suitable size complete all as specified and directed.
S&F Flat Three Core weather proof PVC Insulated & PVC Sheathed Industrial Cable for Submersible pump, multi stranded copper conductor 1100V, 4 sqmm conforming to IS:694 for connection from starter to pump sets complete all as specified and directed.
S&F MCB TP 16 Amps,415 Volts,10 KA, "C" series complete all as specified and directed.
Supply, install, testing and commisioning of factory made pump controller in Galvanised steel sheet enclosure of IP55 protection, with DOL starter suitable for motor rating upto 7.5 HP, AC 3 duty, 415 V (Coil Voltage - 200-400 V), 50 Hz, 3 Phase, relay range 9-14 A complete with specifications :- Contactor : Heavy duty 4 Pole Contactor Digital Ammeter : 0-50A R-Y-B Digital voltmeter : 0-500V RY-YB-BR Overload protection & Under load Protection Over voltage & under voltage protection Single phase preventer : with current and voltage sensing Switch : Auto-Manual Power and control wiring : Copper Output : Terminals LED Indicating lamp : Motor ON & Trip indication, R-Y-B Push button : ON/OFF
M&L for construction of brick masonary in cement mortar (1:4) valve pit of internal dimension 1200 mm x 1200 mm x 1200 mm including 3.15 mm thick MS Sheet cover, angle iron frame made out of 50 mm x 50 mm x 6 mm MS angle iron, hinges, locking arrangement , 15 mm thick plaster in cemrnt mortar (1:4) internally, 20 mm thick plaster in cement mortar (1:6) externally up to 15 cm depth fro the ground level, two coats of black bituminous paint over a coat of red oxide primer on MS cover both internally and externally, 150 mm thick PCC (1:3:6) type C2 using 40 mm graded crushed stone aggregate at bottom with 100 mm clear projection from the outer face of brick wall all round, including necessary earth work complete all as specified and directed.
S&F Ultrasonic type water level sensor for 01 for UG sump, with dead band of less than 0.6 meter, IP 66 protection, accuracy of 0.25% of /f.S and RS485 Modbus RTU communication protocol, capable for working in ambient temperature of 0 degrees to 75 degrees centrigrade, non-condensing at 25 degree centrigrade and humidity up to 95% with response time of less than 1 sec with 230 V AC to 24 V DC, 50 HZ power supply LCD display type, vertical type mounting on water tank with all connections and fixing including clamp, nits, bolts complete of size all as. The spcified level sensor shall be equipped with QR codes designed for geo-tagging purposes. These QR codes shall integrate with an asset management system, allowing for efficient tracking and management of the level sensor. By scanning the QR code, userrs should be able to access derailed information about the asset's location, usage history, maintenance schedules, and performance data. This system shall enhance the visibility and control over the assets, ensuring the are effectively monitored and maintined. Geo-tagging via QR codes should provide a streamlined solution for asset tracking, improving operational efficiency and reucing the risk of asset loss or mismangement complete all as specified and directed.
Supply, Installation, Testing & Commissioning of Magnetic Float Operated Pivoted Level Switch (FPS) high, low or intermediate point level switching and ideal for over head tanks with inaccessible tops or bottoms complete with following Specifications :- Installation : Normally slide / Top for special applications Enclosure X Cable entry : Cast AI IP66 x PG 11 Gland MOC : SS316 Float Dia x Min SG : Ø50/Ø60 x SS (≥0.7 SG) Process Connection : Flanged or srewed Magnetic Switch Assembly : Micro switch in hermetically sealed casing (SPDT) 5A, 250VAC / 24 VDC Switching Differential : Fixed : 15 ± 5 mm Adjustable : between 40 & 300 mm depending upon float, trim length & cam positioning for SS MOC Repeatability / Accuracy : ± 1 mm / ± 2 mm Load / Insulation : Resistive / 150 M Ohm at 500 VDC (Min) Temperature Range : Standard Finish : Regular
S&F SCADA ready actuated electri butterfly valve for 100 NB size water supply systems, with open area installation line pressure maximum-7 Bars , Ends-wafer, Duty -on/off, 230 V AC/24 V DC, IP 67, enclusore, insulation class F, complete with travel switch and torque switch of size 100 NB (may reduce as per site). The specified butterfly valve shall be equipped with QR codes designed for geo-tagging purposes. These QR codes shall integrate with an asset management system, allowing for efficient tracking and management of the level sensor. By scanning the QR code, userrs should be able to access derailed information about the asset's location, usage history, maintenance schedules, and performance data. This system shall enhance the visibility and control over the assets, ensuring the are effectively monitored and maintined. Geo-tagging via QR codes should provide a streamlined solution for asset tracking, improving operational efficiency and reucing the risk of asset loss or mismangement complete all as specified and directed.
Supply, Installation, Testing and Commissioning of pressure transmitters in the water supply lines. The Pressure Transmitter needs to be with proper wiring including necessary with following specification complete all as specified and directed:- Pressure Range: 0 bar to 16 bar Enclosure : Weather proof IP 65 Ambient temperature : -40 TO 70 Deg C Accuracy : 0.5 % Must have RS485 Modbus enabled communication
Supply installation and commissioning of RS485 Communication cable, two pairs stranded copper, (7*32) tinned copper conductors, polyethylene insulation, twister pairs, aluminium / polyster 100% coverage, Tinned copper braid shield 90% coverage, 24 AWG strained tinned copper drain wire, armoured, PVC jacket with the following specifications: (i) Outer jacket : Polyvinyl Chloride, 0.34 in (ii) Conductor DCR : 24 Ω/100 ft (iii) Nominal outer shleid DCR : 2.2 Ω/100 ft (iv) Nominal capacitance conductor to conductor : 12.8mF/ft (v) Nominal capacitance conductor to other conductor to shield 23 mF/ft (vi) Nominal capacitance conductor to conductor : 12.8mF/ft (vii) Frequency : 1 Mhz (viii) Nominal insertion loss : 0.6 DB/100m
Supply, installation, Testing and commissioning of UPS of suitable capacity with adequate battery back up consisting of sealed maintenance free batteries with weatherproof enclosure and locking arrangement complete including electric connection from tapping and to PLC based control panel with armoured copper wire including isolation transformer and surge protection device complete all as specified and directed. Note : - (i) The scope of work includes intergrating the UPS with PLC based panel so as to ensure that the PLC based panel, communication panel and the motorised valves, sensor, electromagnetic flow meter are functional even in case of power failure for a mimimum of 30 Min. (ii) UPS shall be provided at Pump House
Supply, Installation Testing & Commissioning of Indoor type PLC (Programmable Logic Controller) / RTU (Remote terminal Unit) based Automation, Protection Panel for UG & O/H Service cum Fire tank, Pumps & Valve operation, energy monitoring with feature of wireless Dual SIM Card based communication, suitable for control and monitoring of 2 Nos. openwell Pumps, 1 No. Motorized Butterfly Valve, 01 No Ultrasonic level sensor, 01 No Techtrol Magnetic Float Operated Pivoted Level Switch, 1 No pressure transmitters, 01 Nos. electromagnetic Flow Meters. The panel should be of suitable size front opening type, fabricated from 2.00 mm thick CRCA Sheet & mounting channel 40x40x5mm made out of Angle iron with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLSH cable of adequate size. The Panel should have the following functionalities complete all as specified and directed:- (a) Protection Panel for Borewell monitoring & Control. (b) Automatic Pump On/Off, Automatic Priming and Air Release (if reqd) (c) Automatic Operation of Motor Actuated Butterfly Valves & level control of semi-UG sump (d) Automatic Toggling of Pumps (e) Auto Change Over in Case of Pump Failure (f) Pressure Gauges / Transmitters shall be installed in piping systems to measure drop across. (f) Single Phasing Prevention, phase sequence corrector (g) Online UPS with battery system of adequate capacity. (h) Manual Mode Operation (all connected sub systems at filtration plant) from the RTU/ PLC based Control Panel.
Supply, Install, Testing and Commissioning of 11kV 630 Amps 21 KA for 3 Sec.SF6 insulated, both side extensible, outdoor duty Ring main unit, fully motorized, in combination of 2 Nos. Load Break Switch as incomer, 01 Nos VCB module as Outgoing, 1 No. LBS as Bus - Sectionalizer (CSLVC), consisting of copper busbar in SF6 insulated 304 (Non - Ferrite Non - Magnetic Grade) stainless steel enclosure of thickness 2.5 mm with manometer fixed on the tank. The Breaker shall have mechanical ON/OFF indicator with hand trip device and spring charging, spring release coil. The HV switchgear and control gear should be confirming to IEC - 62271-1,100,200. The RMU gas tank should be internal arc tested for 21 KA for 1 second with IAC - AFLR classification for gas tank. The complete RMU mimic and cable chamber should be covered by a single door to have ingress protection of minimum IP54. The RMU design should support site replaceable HT cable bushing and VI of VCB should be RMU Manufacturer's own make. RMU should have following: - 1 No, microprocessor based self powered numerical relay with Over Current / Earth fault & short circuit protection (with Rs 485 port and modbus protocol) in each VCB feeder, Relay should display each phase current. - 3 Nos, Protection CT shall be of Burden 2.5 VA, ratio 200 - 100/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB outgoing feeder.
Serial item No. 20.113 continued..... OUTGOING:- (a) MCCB 4 P 400A, 36 kA, Miroprocessor based electronic release with LSIG protection - 02 No (For Bldg Non-DG load & Utility 250 kVA DG AMF panel) (b) MCCB 4 P 250A, 36 kA, Miroprocessor based electronic release with LSIG protection - 02 No (01- 160kVA DG AMF panel, 01 Spare) (c) MCCB 4 P 125A, 25 kA, Thermal Magnetic based, adjustable range 0.7 to 1 In - 02 No (01-Solar, 01-Spare) (d) Intelligent panel meter to measure voltage, current frequency, power factor, kWH, etc with all connected CTs -01set (e) LED indicating lamps with colour R,Y,B - 01 set
Serial item No. 20.115 continued..... INCOMING:- MCCB 4 pole, 250 Amps, 36 kA, Miroprocessor based electronic release with LSIG protection - 01 No. OUTGOING:- (a) MCCB 4 P 63A, 16kA, Fixed Thermal Magnetic release - 06 No (Each at one floor + 01 Spare) (b) MCB 4P 6-32A, 16 kA 'C' curve - 03 Nos (01-Bldg faccade lighting, 01-Security light, & 01-Spare) (c) Intelligent panel meter to measure voltage, current frequency, power factor, kWH, etc with all connected CTs -01set (d) LED indicating lamps with colour R,Y,B - 01 set
S&F Cast iron cable route indicator width 4" with embossing mark as HT/LT cable, shall be directly burried into the ground and having withstand capacity in all type of weather conditions and physical impact and painted with bright colour. complete as specified and directed
S&F street light junction box mistral IP 65 thermoplastic enclousers with transperent door 4mm thick in 4 modulus in single row of size 52 x 202 x 117 with SP 0.5 Amp MCB and including clamp of size 25x3 mm thick of flate iron with bolt, nut etc required in mounting in steel tubular pole 9.0 mtr long complete all as specified and directed.
M&L for connection of junction box to street light luminaire using wiring with two runs (P-N) of single core 1.5 Sqmm (nominal area) FR PVC insulated and unsheathed multi-stranded copper conductor cable 1100 volts grade and one run of FR PVC insulated and unsheathed multi-stranded copper conductor of size 1.5sqmm single core as earth continuity wire drawn through PVC conduit (Heavy grade) and tightening/fastening the same by aluminium strip with the pole complete all as specified and directed. Notes :- Two run of single core 1.5 Sqmm wire and one run of single core 1.5 Sqmm earth conductor wire and one run of PVC conduit all together shall be measured as one unit.
Supplying and laying of DWC HDPE pipe ISI marked of size 120mm m dia (OD-120 mm & ID-103 mm nominal) along with all accessories like socket, bend, couplers etc. conforming to IS:14930, Part Il with fitting and cutting, jointing etc. in the existing trench as required complete all as specified and directed.
Supplying and laying of DWC HDPE pipe ISI marked of size 90mm m dia (OD-90 mm & ID-76 mm nominal) along with all accessories like socket, bend, etc. conforming to IS:14930, Part Il with fitting and cutting, jointing etc. in the existing trench as required complete all as specified and directed.
M&L for construction of platform of size 3.00 x 3.00 x 2.00 m high from GL for plinth mounting of transformer of capacity 500 KVA, including excavation in trenches not less than 1 mtr, PCC (1:5:10) type E2 for foundation, brick work in cm (1:6), PCC (1:2:4) type B1 in copping, plaster 10 mm thick in cm (1:6) on brick / concrete surface, 75 mm thick PCC (1:4:8) type B1 as in sub base , 100 mm thic PCC (1:2:4) type B1 as in floring using extra cement, returning filling and removal on surplus soil, chain link fencing 1.8 m high made out of 4 mm dia of GI wire 150x100mm mesh, MS angle iron 50x50x6mm as fencing post in embeded in brick /PCC at 2 mtr interval each side as approved 1 No steel gate (3.5m clear) span with locking arrangement made out of 15 mm dia ms rod & 50x50x6 mm angle iron frame, painting with 2 coats of aluminium paint over a coat of red oxide primer and 3 coats of white washing on cement work including 2 Nos ISMB 100 mm chanel for fixing transformer including ramp of suitable size mounting of transformer and suitable size of steps/ stairs over plate form complete all as specified and directed.
Boring for bored cast-in-situ piles 600 mm dia. in any type of soil using DMC (Direct Mud Circulation) method of boring and getting out and disposal of spoil out side MD land complete all as specified and as shown on drawings and as directed.
Boring for bored cast-in-situ piles 1200 mm dia. in any type of soil using DMC (Direct Mud Circulation) method of boring and getting out and disposal of spoil out side MD land complete all as specified and as shown on drawings and as directed.
M&L for Reinforced cement concrete (design mix) M-30 grade design mix as in Cast-in-situ piles etc., complete all as specified and as directed. Note: Pile shall be casted as mentioned in drawings. However, for payment purpose the length of pile shall be measured up to cut off level only. The unit rate quoted shall be deemed to included this aspect.
M&L for Reinforced cement concrete (design mix) M-35 grade design mix as in Cast-in-situ piles etc., complete all as specified and as directed. Note: Pile shall be casted as mentioned in drawings. However, for payment purpose the length of pile shall be measured up to cut off level only. The unit rate quoted shall be deemed to included this aspect.
Carrying out initial pile load tests for 600 mm dia pile as per IS: 2911- Part 4 with carrying out necessary calibrated measuring devices like load/pressure guage, hydraulic jack, dial gauges and magnetic stands, submitting all the test reports to GE with proper presentation complete all as specified and directed.
Carrying out initial pile load tests for 1200 mm dia pile as per IS: 2911- Part 4 with carrying out necessary calibrated measuring devices like load/pressure guage, hydraulic jack, dial gauges and magnetic stands, submitting all the test reports to GE with proper presentation complete all as specified and directed.
Conducting low strain integrity test on 600mm diameter RCC cast-in-citu piles, data analysis and submission of report. (min 10 piles per visit) complete all as specified and directed.
Conducting low strain integrity test on 1200mm diameter RCC cast-in-citu piles, data analysis and submission of report. (min 10 piles per visit) complete all as specified and directed.
Carrying out routine pile load tests for 600 mm dia pile as per IS: 2911- Part 4 with carrying out necessary calibrated measuring devices like load/pressure guage, hydraulic jack, dial gauges and magnetic stands, submitting all the test reports to GE with proper presentation complete all as specified and directed.
Carrying out routine pile load tests for 1200 mm dia pile as per IS: 2911- Part 4 with carrying out necessary calibrated measuring devices like load/pressure guage, hydraulic jack, dial gauges and magnetic stands, submitting all the test reports to GE with proper presentation complete all as specified and directed.
PHASE II (COMPREHENSIVE MAINTENANCE WORK)
Comprehensive Maintainance of 2 x 18 HP and 2 x 20 HP VRF AC plant with AHU ducted air distribution system by OEM/ Authorised dealer of OEM including preventive maintainance services and attending all call breakdowns.Checking, maintaining and ensuring smooth function of the Air conditioning system equipments without any abnormalities in noise, temperature,pressures and current drawn by the motors and carrying out rectification/repair/replacement of defective parts.The key inclusion in the contract are maintaince and repair/replacement of following components in Air conditioning system:- (a) VRF outdoor unit (b) Refrigeration circuit (c) AHU (d) Ducted air distribution unit with complete control unit (e) All the electrical components /sensors/control panel/Remote Monitor units connected to OEM control panel. The scope of work under AMC inclusive the following:- (a) 04 (Four) routine services in a year on quarterly basis includes:- (i) Checking of cooling efficiency and tunning of system for its efficient operation. (ii) Checking of motors, control circuits & panels, communication unit. (iii) Cleaning of evaporator and condenser coils, blowers & fans, AHUs, duct system, diffusers, dampers, etc (iv) Checking tightness of regular operational units like motor, pump, belt and other units to ensure its smooth operation.. (b) Immediate attendance of breakdown, if any. (c) Repairing of leakage, Refrigerant gas charging, if necessary.
(a) Comprehensive annual maintenance of complete VRF AC unit held at Admin Bldg, 3 Corps, RMS for first year after defect liability period complete all as specified and directed.
(b) Comprehensive annual maintenance of complete VRF AC unit held at Admin Bldg, 3 Corps, RMS for second year after defect liability period complete all as specified and directed.
(c) Comprehensive annual maintenance of complete VRF AC unit held at Admin Bldg, 3 Corps, RMS for third year after defect liability period complete all as specified and directed.
(a) Comprehensive annual maintenance of lift held at Admin Bldg, 3 Corps, RMS for first year after defect liability period complete all as specified and directed.
(b) Comprehensive annual maintenance of lift held at Admin Bldg, 3 Corps, RMS for second year after defect liability period complete all as specified and directed.
(c) Comprehensive annual maintenance of lift held at Admin Bldg, 3 Corps, RMS for third year after defect liability period complete all as specified and directed.
(a) Comprehensive annual maintenance of 250 KVA held near 3 Corps substation, RMS for first year after defect liability period complete all as specified and directed.
(b) Comprehensive annual maintenance of 250 KVA held near 3 Corps substation, RMS for second year after defect liability period complete all as specified and directed.
(c) Comprehensive annual maintenance of 250 KVA held near 3 Corps substation, RMS for third year after defect liability period complete all as specified and directed.
(a) Comprehensive annual maintenance of 160 KVA held near 3 Corps substation, RMS for first year after defect liability period complete all as specified and directed.
(b) Comprehensive annual maintenance of 160 KVA held near 3 Corps substation, RMS for second year after defect liability period complete all as specified and directed.
(c) Comprehensive annual maintenance of 160 KVA held near 3 Corps substation, RMS for third year after defect liability period complete all as specified and directed.
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.35 MB
BOQ_837334.xls
BOQ • 0.67 MB
maindrgs1.pdf
Additional Documents • 18.86 MB
maindrgs2.pdf
Additional Documents • 28.57 MB
TDDRAWINGS.pdf
Additional Documents • 13.89 MB
tender.pdf