Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.4 LAccepted-AOC COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | ₹47.4 L | L1 | Accepted-AOC ACCEPTED BEING THE LOWEST |
| 2 | L2₹50.2 L+₹2.9 L (6.07%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | ₹50.2 L+₹2.9 L (6.07%) | L2 | Rejected-Finance REJECTED NOT BEING THE LOWEST |
| 3 | L3₹51.1 L+₹3.7 L (7.80%)Rejected-Finance | ₹51.1 L+₹3.7 L (7.80%) | L3 | Rejected-Finance REJECTED NOT BEING THE LOWEST |
| 4 | L4₹52.1 L+₹4.7 L (9.98%)Rejected-Finance NEAR NAMRUP POLICE P O PARBATPUR DISTT DIBRUGARH ASSAM 786 623 | DIBRUGARH | ASSAM | 786623 | ₹52.1 L+₹4.7 L (9.98%) | L4 | Rejected-Finance REJECTED NOT BEING THE LOWEST |
| 5 | L5₹52.9 L+₹5.5 L (11.6%)Rejected-Finance | ₹52.9 L+₹5.5 L (11.6%) | L5 | Rejected-Finance REJECTED NOT BEING THE LOWEST |
| Sl No | Description | Qty | Unit | PURBANCHAL BUILDERS L7 | M/s PRABIR ENTERPRISE L1 | M/S SINGH TRADERS L6 | STANDARD ELECTRIC WINDERS L2 | MANASEE L5 | M/s Mrinal Dowarah L4 | THE SUPPLY AGENCY L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for spray painting of transformer preparation of old painted surfaces of steel body by brushing/cleaning stain, greasy spots with thinner outside of transformer indoor/outdoor type capacity 63 KVA to 160 KVA to match with existing colour complete all as specified and directed. | 7 | EACH JOB | 2,759 ₹19,313 Lowest | 3,000 ₹21,000 | 3,699 ₹25,893 | 3,205 ₹22,435 | 3,454 ₹24,178 | 3,216 ₹22,512 | 3,324 ₹23,268 |
| 2.00 | All as per ser item No 1 above here-in-before but capacity of 200 KVA to 315 KVA | 8 | EACH | 3,779 ₹30,232 | 3,800 ₹30,400 | 4,383 ₹35,064 | 3,495 ₹27,960 | 4,090 ₹32,720 | 3,252 ₹26,016 Lowest | 4,126 ₹33,008 |
| 3.00 | All as per ser item No 1 above here-in-before but capacity of 500 KVA to 630 KVA | 3 | EACH | 4,179 ₹12,537 | 4,500 ₹13,500 | 4,858 ₹14,574 | 4,232 ₹12,696 | 4,475 ₹13,425 | 3,851 ₹11,553 Lowest | 4,584 ₹13,752 |
| 4.00 | All as per ser item No 1 above here-in-before but capacity of 800/1000 KVA | 3 | EACH | 7,419 ₹22,257 Lowest | 8,000 ₹24,000 | 8,584 ₹25,752 | 8,474 ₹25,422 | 7,907 ₹23,721 | 8,515 ₹25,545 | 7,848 ₹23,544 |
| 5.00 | Dehydration of HV grade transformer oil (On line/off line), to achieve dielectric strength 40 KV to 60 KV for HV grade, complete all as specified and directed.
Note - Centrifuging Machine with all T&P & testing eqpt required for dehydration to be arranged by the contractor. | 13,000 | LITRE | 39 ₹5,07,000 | 28 ₹3,64,000 Lowest | 31 ₹4,03,000 | 29 ₹3,77,000 | 31 ₹4,03,000 | 38 ₹4,94,000 | 33 ₹4,29,000 |
| 6.00 | Supply and filling, transformer oil HV grade as per IS-335 of 1993 Part-II for top up / replacment as per direction by Engr-in-Charge. | 2,250 | LITRE | 239 ₹5,37,750 | 200 ₹4,50,000 Lowest | 217 ₹4,88,250 | 215 ₹4,83,750 | 254 ₹5,71,500 | 232 ₹5,22,000 | 225 ₹5,06,250 |
| 7.00 | M & L for rewinding HV/LV coils of transformer of using proper size super enameled copper wire suitable for working voltage 11 KV/0.433 KV including three layerinsulated materials as per eisting size of core including testing & commissioning complete all as specified and directed at site
NOTE :-
i). Oil filtration,supply of new oil will be measured separately.
ii). All petty parts including nut, bolts, gasket minor weldings are deemed to be included the rate quoted.
iii). The rate for taking out,refixing after repair,both side transportation, lifting /unloading of voltage stabilizer/isolation transformer by crane /manual should be deemed to include in the rate quoted. | 90 | KILOGRAM | 2,229 ₹2,00,610 | 1,920 ₹1,72,800 | 2,083 ₹1,87,470 | 1,797 ₹1,61,730 Lowest | 2,040 ₹1,83,600 | 2,074 ₹1,86,660 | 2,141 ₹1,92,690 |
| 8.00 | M & L for 11 kv/0.433 KV HT/LT side transformer coils, removing unsv/burnout insulation materials, and reinsulation with new insulated materials with three layer complete as per existing including heating, varnishing etc complete all as specified and directed. | 70 | KILOGRAM | 699 ₹48,930 | 620 ₹43,400 Lowest | 790 ₹55,300 | 664 ₹46,480 | 732 ₹51,240 | 644 ₹45,080 | 690 ₹48,300 |
| 9.00 | S & F in repairs LT bushing with brass stud, packing ,nut, bolt, washers etc suitable for 200 KVA to 315 KVA 11000/433V complete all as specified and directed. | 2 | EACH | 2,829 ₹5,658 | 2,600 ₹5,200 Lowest | 3,205 ₹6,410 | 2,779 ₹5,558 | 2,995 ₹5,990 | 2,612 ₹5,224 | 2,925 ₹5,850 |
| 10.00 | S & F in repairs LT bushing with brass stud, packing ,nut, bolt, washers etc suitable for 500 KVA to 630 KVA 11000/433V complete all as specified and directed. | 2 | EACH | 3,199 ₹6,398 Lowest | 3,500 ₹7,000 | 4,315 ₹8,630 | 3,741 ₹7,482 | 4,018 ₹8,036 | 3,764 ₹7,528 | 3,937 ₹7,874 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
25 Dec 2025, 6:00 pmClosed
CWE (AF) JORHAT
HQ CWE (AF) JORHAT ROWRIAH 785004
84180/E8 REPAIR AND MAINTEANCE OF POWER TRANSFORMER, DISTRIBUTION TRANSFORMER, HT UG CABLE, VCB AND ALLIED WORKS AT AF STATION CHABUA UNDER GE(AF) CHABUA
2025_MES_742396_1
84180/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE (AF) CHABUA
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) CHABUA
₹98,000
Yes
11 Feb 2026
2 Dec 2025
1 Jan 2026
2 Dec 2025
25 Dec 2025
18 Dec 2025
Amount
M&L for spray painting of transformer preparation of old painted surfaces of steel body by brushing/cleaning stain, greasy spots with thinner outside of transformer indoor/outdoor type capacity 63 KVA to 160 KVA to match with existing colour complete all as specified and directed.
All as per ser item No 1 above here-in-before but capacity of 200 KVA to 315 KVA
All as per ser item No 1 above here-in-before but capacity of 500 KVA to 630 KVA
All as per ser item No 1 above here-in-before but capacity of 800/1000 KVA
Dehydration of HV grade transformer oil (On line/off line), to achieve dielectric strength 40 KV to 60 KV for HV grade, complete all as specified and directed. Note - Centrifuging Machine with all T&P & testing eqpt required for dehydration to be arranged by the contractor.
Supply and filling, transformer oil HV grade as per IS-335 of 1993 Part-II for top up / replacment as per direction by Engr-in-Charge.
M & L for rewinding HV/LV coils of transformer of using proper size super enameled copper wire suitable for working voltage 11 KV/0.433 KV including three layerinsulated materials as per eisting size of core including testing & commissioning complete all as specified and directed at site NOTE :- i). Oil filtration,supply of new oil will be measured separately. ii). All petty parts including nut, bolts, gasket minor weldings are deemed to be included the rate quoted. iii). The rate for taking out,refixing after repair,both side transportation, lifting /unloading of voltage stabilizer/isolation transformer by crane /manual should be deemed to include in the rate quoted.
M & L for 11 kv/0.433 KV HT/LT side transformer coils, removing unsv/burnout insulation materials, and reinsulation with new insulated materials with three layer complete as per existing including heating, varnishing etc complete all as specified and directed.
S & F in repairs LT bushing with brass stud, packing ,nut, bolt, washers etc suitable for 200 KVA to 315 KVA 11000/433V complete all as specified and directed.
S & F in repairs LT bushing with brass stud, packing ,nut, bolt, washers etc suitable for 500 KVA to 630 KVA 11000/433V complete all as specified and directed.
S & F in repairs LT bushing with brass stud, packing ,nut, bolt, washers etc suitable for 800 KVA to 1000 KVA 11000/433V complete all as specified and directed.
S & F in repairs HT bushing with brass stud, packing ,nut, bolt, washers etc suitable for 200 KVA to 315 KVA 11000/433V complete all as specified and directed.
S & F in repairs HT bushing with brass stud, packing ,nut, bolt, washers etc suitable for 500 KVA to 630 KVA 11000/433V complete all as specified and directed.
S & F in repairs HT bushing with brass stud, packing ,nut, bolt, washers etc suitable for 800 KVA to 1000 KVA 11000/433V complete all as specified and directed.
S & f in repair Transformer top cover gasket/cock sheet suitable for 63 KVA to 160 KVA transformer complete all as specified and directed at site.
S & f in repair Transformer top cover gasket/cock sheet suitable for 200 KVA to 315 KVA transformer complete all as specified and directed at site.
S & f in repair Transformer top cover gasket/cock sheet suitable for 500 KVA to 630 KVA transformer complete all as specified and directed at site.
Supply and fixing in repalcement of heavy duty breather assembly of capacity 0.5 kg with silica gel cristal complete all as specified.
Supply and filling silica gel cristal in to breather assembly complete all as specified and directed at site.
Supply and fix in replacement of Marshling box suitable for 7.5 MVA power transformer complete all as specified and directed at site
Supplying and laying synthetic Rubber insulated mats 3 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed at site.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m
Taking out of 11 KV 3 core 95 sqmm HT cable from duct/trench by taking proper electric shut down from AGE E/M (AF) Chabua and making good to the disturbed surface complete all as specified and as directed.
Supply, laying in trenches/through pipes under road, floor/ on wall/on pole or any other indicated place & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)with stranded aluminum conductor, 11000 volts grade, of size 3 core 95 sq mm complete all as specified.
Taking out of 11 KV 3 core 240 sqmm HT cable from duct/trench by taking proper electric shut down from AGE E/M (AF) Chabua and making good to the disturbed surface complete all as specified and as directed.
Supply, laying in trenches/through pipes under road, floor/ on wall/on pole or any other indicated place & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)with stranded aluminum conductor, 11000 volts grade, of size 3 core 240 sq mm complete all as specified and directed at site
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx 180mm x 40mm laid in trenches as cable covers complete all as directed.
Supply and fix in repair of cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE aromoured aluminium conductor cable of size 240 sq mm. complete all as specified and directed at site
Supply and fix in repair of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm. complete all as specified and directed at site
Supply and fix in repair of cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint with jointing material and accessories complete suitable for 3 core XLPE aromoured aluminium conductor cable of size 240 sq mm. complete all as specified and directed at site
Supply and fix in repair of cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE aromoured aluminium conductor cable of size 95 sq mm. complete all as specified and directed at site
Supply and fix in repair of cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint with jointing material and accessories complete suitable for 3 core XLPE aromoured aluminium conductor cable of size 95 sq mm. complete all as specified and directed at site
Supply and fix in repair of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm. complete all as specified and directed at site
Attending of 33/11 KV HT breakdown and finding the fault in transformers, VCBs, CTs,PTs, lighting arrestor, insulator etc by highly skilled mechanic to replace any sparss related breakdown complete all as specified and directed at site. (a) a sum of Rs 4000.00/day will be recovered in case of not attend break down by service Engineer and not rectified defect with in 24 Hrs. (b) Spars will be paid separately under relative items. (c) Labour to be included the quoted rates
Re-stringing Over Head Line ACSR Conductor and earth wire of any size and type on HT poles including disconnection on Existing Lines by un-binding at Each Pin/Shackle Type Insulator, re-fixing the same after stretching Conductor, removing excess Sag, maintaining proper distance between Conductors adjusting line dividers etc and cutting trimming of tree branches upto 2 mtr clear distance from wire, complete all as directed by Engr-in-Charge.
M&L in repair triple pole mechanical operated , mounted on insulator with operating mechanisam isolator worked from ground level for current rating 400 amps amps suitable for 33000 volts complete all as specified and directed.
M&L in repair triple pole mechanical operated , mounted on insulator with operating mechanisam worked from ground level for current rating 400 amps amps suitable for 11000 volts complete all as specified and directed.
Supply and stringing in repair ACSR conductor of any size for HT/LT over head line as directed including fixing to insulators with proper size of binding wire complete all as specified and directed at site
All as per item 42 but GI wire 4 mm dia complete all as specified and directed at site
Supply and fixing, in replacement of 33 KV potentional transformer out door type complete all as specified and directed by engr-in-charge.
Supply and fixing, in repair of 33 KV current transformer out door type complete all as specified and directed by engr-in-charge.
Supply and fix in repair 33 KV Lightning arresters expulsion type with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed at site.
Supply and fix in repair 11 kV Lightning arresters expulsion type with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed at site.
M&L in repair drop out fuse single pole suitable for 11000 volts grade upto 50 amps complete all as specified and directed.
M&L in repair drop out fuse suitable for 33000 volts grade complete all as specified and directed.
M & L in repairs for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of alminum paint over a coat of red oxide primer, complete all as directed.
Disconnecting HT supply and servicing of 33 KV outdoor type VCB by cleaning isolating contacts moving parts removing dust particles from bus bar chamber spout gear mechanism and moving parts, repair to motor charge spring mechanism tightening of nut & bolts and replacement of all unserviceable spares as required and all as directed, testing commissioning and putting on the supply on load complete all as directed by the Engr-in-charge. Note: - (i) Servicing will be done once in every 06 months or as directed by Engr-in-Charge (ii) Spares as required for replacement will be of the same company as of existing make or as recommended by the OEM (iii) Cost of spares will be measured and paid separately under relevant items. (iv)) All Measuring equipments and T&P required shall be arranged by the contractor.
Disconnecting HT supply and servicing of 33 KV indoor type VCB control panel by cleaning isolating contacts moving parts removing dust particles ,tightening of nut & bolts and replacement of all unserviceable spares as required and all as directed, testing commissioning and putting on the supply on load complete all as directed by the Engr-in-charge. Note: - (i) Spares as required for replacement will be of the same company as of existing make or as recommended by the OEM (ii) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound, painting of VCB panels with approved colour all as per existing etc. to put in to the VCBs and panels in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge. (iii) Major spares like Breaker bushings, vacuum interrupter assly, bus bar spout, bus bar spout connections, circuit spout/circuit spout connections/buffer fixed contacts, moving contacts, tank assly/barriers, solenoid spares, dependent/spring mechanism/ motor mechanism, trip unit etc will be measured and paid separately under relevant items of Schedule 'A'. However the rate quoted shall be deemed to include for any other minor spares require replacement.
Disconnecting HT supply and taking out defective trolley of 11 KV VCB of any make and type and servicing of VCB by cleaning isolating contacts moving parts removing dust particles from bus bar chamber spout gear mechanism and moving parts, repair to motor charge spring mechanism tightening of nut & bolts of entire trolley components and replacement of all unserviceable spares as required and all as directed, inserting in trolley, testing commissioning and putting on the supply on load complete all as directed by the Engr-in-charge. Note: - (i) Spares as required for replacement will be of the same company as of existing make or as recommended by the OEM (ii) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound, painting of VCB panels with approved colour all as per existing etc. to put in to the VCBs and panels in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge. (iii) Major spares like Breaker bushings, vacuum interrupter assly, bus bar spout, bus bar spout connections, circuit spout/circuit spout connections/buffer fixed contacts, moving contacts, tank assly/barriers, solenoid spares, dependent/spring mechanism/ motor mechanism, trip unit etc will be measured and paid separately under relevant items of Schedule 'A'. However the rate quoted shall be deemed to include for any other minor spares require replacement.
Supply only Vaccum spout suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model complete all as specified and directed at site
Supply only Busbar Spout suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model complete all as specified and directed at site
Supply only Mechanical Castle interlock assembly with Key suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model complete all as specified and directed at site.
Supply only Tripping coil assembly 24 Volts DC suitable for 11 KV VCB as per existing make and model complete all as specified and directed at site.
Supply only Closing coil assembly 24 Volts DC suitable for 11 KV VCB as per existing make and model complete all as specified and directed at site.
Supply only 11 KV PT HRC fuse AVT type 0.5 to 6 Amp and 2.5 KV to 36 KV as per existing make and model complete all as specified and directed at site.
Supply only Limit switch suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model complete all as specified and directed at site
Supply only Relay suitable for 11 KV VCB of rating 400/630/800 amps complete all as specified and directed at site.
Supply only Relay suitable for 33 KV control panel complete all as specified and directed at site.
Supply only Moving contact block suitable for 11 KV VCB as per existing make and model complete all as specified and directed at site.
Supply only Fixed contact block suitable for 11 KV VCB for rating 400/630/800 Amps as per existing make and model complete all as specified and directed at site.
Supply only MCBs , DP , 240 Volts , 6 to 32 Amps , 10 kA , AC/DC
Supply only LED indication lamp for VCB control panel
Supply only Single unit resin cast type potential Transformer of rating 11 KV, ratio 11KV/ √3/110V/√3 burden 100VA, pistol type
Supply only Single unit resin cast type current Transformer of rating 11 KV, ratio 50-25/5-5A, burden 5P10 for protection and 10VA for metering
Supply only Vacuum interrupter suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model
Supply only Charging motor suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model .
Supply only Tripping push button suitable for 11KV VCB of rating 400/630/800 Amps as per existing make and model
Supply only Digital amp meter (1 Phase) suitable for 11 VCB of rating 400/630/800 amps as per existing make and model .
Supply only Digital volt meter (1 Phase) suitable for 11 KV VCB of rating 400/630/800 amps as per existing make and model . Note for item ser No 54 to 73 : Labour rate for fixing shall be included the quoted rates against item No 51,52 & 53
Material and labour for spreading of graded crashed aggregate 40mm nominal size to a true surface and leveled in layers not exc. 20 cm thick for switch yard complete all as specified and directed by Engr-in-Charge.
Material and labour for painting of eight pole structure consisting of 11m long steel tubular poles including cross arms, clamps of any length and shape, for HT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm dia circle and marking bottom of pole to 1.5m height, complete all as specified and directed.
Material and labour for painting of six pole structure consisting of 11m long steel tubular poles including cross arms, clamps of any length and shape, for HT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm dia circle and marking bottom of pole to 1.5m height, complete all as specified and directed.
Material and labour for painting of four pole structure consisting of 11m long steel tubular poles including cross arms, clamps of any length and shape, for HT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm dia circle and marking bottom of pole to 1.5m height, complete all as specified and directed.
Material and labour for painting of three pole structure consisting of 11m long steel tubular poles including cross arms, clamps of any length and shape, for HT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm dia circle and marking bottom of pole to 1.5m height, complete all as specified and directed.
Material and labour for painting of two pole structure consisting of 11m long steel tubular poles including cross arms, clamps of any length and shape, for HT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm dia circle and marking bottom of pole to 1.5m height, complete all as specified and directed.
Material and labour for painting of HT tubular poles up to 11 mtr long in two coats of aluminium paint and one coat of red oxide as primer including writing of pole nos all as specified and directed at site.
Material and labour for providing vehicle mounted/wheel mounted fault locator machine for finding HT UG Cable fault of Size 95 sqmm to 240 Sqmm x 3 core, finding the accurate fault location complete all as specified and directed. Note :(a) Necessary excvation,returning and filling with making good to disturbed surface up to 1 Cum for finding fault and repairing of cables is deemed to be included in quoted rate. (b) The Rate is also included for taking shutdown from MRS/nearest Sub stations and disconnected cable from HT Panels/feeder panels. (c ) Contractor shall restored the power supply after completion of work. (d) Necessary Road cutting and making good with PCC is deemed to be included in quoted Rate.
Taking down old unsv/rusted/corroded HT junction box and Supply, installing, testing & commisioning outdoor type feeder pillar box suitable for 11 KV HT Bus Bar Chamber, CPRI approved made out of 3.15 mm CRCA mild steel sheet, powder coated, dust and vermin proof with rain water protection, double door type with locking arrangements, size of feeder pillar box not less than 1.0 m x 0.50 m x 1.15 m with provision of HT 11 KV post insulators, 3 Nos. fixed inside with suitable size of aluminium bus bars for cable connections and 11000 volts danger notice board on both sides, All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade, panel to be fixed at 45 cm above ground level on brick masonry plateform including 75 mm thick PCC (1:3:6), type C1 (using 20 mm graded stone aggregates) around the area upto 1.5 Mtr in all directions from the panel all as directed.
Supply and fixing in repair 100 mm bore steel tubes, galvanised "light grade", ISI marked for protection of cable under floor, road and on wall complete all as specified and as directed.
Supply and fixing in repair steel tubes, galvanised, light grade, ISI marked 80 mm bore for protection of cable under floor, road and on wall complete all as specified and as directed.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique/Manual and necessary machine suitable for 80/100 mm GI pipe complete all as specified and directed at site
M&L for replacement of pin type insulator porcelain, votreous, white, brown or green insulator including one galvnised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for working pressure 11000 volts grade complete all as specified and directed.
M&L for replacement of disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type white,brown or green single disc assy for tension with tension clamps for conductors,working pressure 11000 volts complete all as specified and directed.
M&L for replacement of disc type insulator, porcelain, vitreous and socket type white,brown or green single disc assy for tension with tension clamps for conductors,working pressure 33000 volts complete all as specified and directed.
M&L for replacement of pin type insulator porcelain, votreous, white, brown or green insulator including one galvnised mild steel spindle, two galvanised iron washers and one galvanised iron nut, for working pressure 33000 volts grade complete all as specified and directed.
DEDUCT 'TOTAL AMOUNT OF CREDIT' AGAINST 'SCHEDULE OF CREDIT' Bidder(s) shall/ will Quote the EQUAL AMOUNT (as per SCHEDULE OF CREDIT of Tender Documents)
STANDARD ELECTRIC WINDERS (BID ID -3507577)
THE SUPPLY AGENCY (BID ID -3506295)
M/s Mrinal Dowarah (BID ID -3507769)
MANASEE (BID ID -3504780)
M/S SINGH TRADERS (BID ID -3507509)
PURBANCHAL BUILDERS (BID ID -3505359)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
BOQ_831346.xls
BOQ • 0.43 MB
TENDER84180.pdf
Tender Documents • 1.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .