Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-AOC | L1 | Accepted-AOC Being the lowest and reasonable bidder | |
| 2 | L2₹21.5 L+₹4.1 L (23.6%)Rejected-AOC | L2 | Rejected-AOC Being the other than lowest bidder | |
| 3 | L3₹22.9 L+₹5.5 L (31.8%)Rejected-AOC | L3 | Rejected-AOC Being the other than lowest bidder |
Tender Value
₹22.9 L
EMD Value
₹45,900
Closing Date
2 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Nagrota
HQ CWE Nagrota Co 56 APO
SPECIAL REPAIR TO OVERHEAD CRANE ELECTRIC WIRING, REPLACEMENT OF COMPLETE EXISTING LIGHT TO LED AND VALLEY GUTTER BLDG NO. TS-56 (WKSP REPAIR BAY) OF EME BN AT NAGROTA UNDER GE NAGROTA
2024_MES_639456_1
CWE/NGT-46/2023-24
Open Tender
Civil Works
Item Rate
182 days
Nagrota
As per NIT and tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Nagrota
₹45,900
Yes
25 Mar 2024
29 Jan 2024
9 Mar 2024
29 Jan 2024
2 Mar 2024
12 Feb 2024
29 Jan 2024 - 5 Feb 2024
Amount
Taking down carefully unserviceable Aluminium point wiring complete (light, fan socket, bell or power) with fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings etc. and keeping in safe custody for taking credit complete all as specified and as directed by Engr-in-Charge
Taking down ceiling fan any sweep, removing blades ,cleaning the fan completely for dust and dirt, oiling & greasing and hanging the same back to its original position including connecting with three core flexible copper wire to ceiling rose etc after the completion of the point wiring including replacement of old unserviceable fan hook, rubber pad, nut bolts and washers etc, complete, all as specified and directed by Engr-In-Charge.
M&L for point wiring with PVC insulated unsheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium grade ISI marked not less than 20mm dia ,concealed in wall and surface on ceiling with all conduit fittings & fixing acessories inculding sunken anodised pressed steel terminal box not less than 1.2mm thick covered with 3 mm thick plastic laminated sheet cover of suitable size with brass screws for mounting switches, sockets, regulators with and including 1.5sqmm FRLS multi stranded copper conductor drawing as continuous earth wire connected to main earth and earth dolly complete all as specified for the following;-
(a) One light point/fan point/exhaust fan point controlled by one switch 5 Amp.
All as per srl item No 3 here in before but point wiring with 2.5sqmm FRLS multi stranded copper conductor cable for main circuit and 2.5sqmm cable as earth continuity conductor for one 15Amp socket out let controlled by one 15Amp switch on independat board.
S&F in repair/replacement switch piano flush type 5 Amps single pole one way complete,
S&F in repair/replacement switch socket combination 2 in 1, 5 pin 5 /15 Amps flush type complete.
Supply and fixing in repair/replacement LED flood light 100 watt, 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fixing in repair/replacement LED flood light 170 watt, 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
S&F LED light fitting 1x9W/1X10W bulkhead luminaires including LED lamp 9W with driver and holder including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in repair/replacement sheet metal enclosure distribution board SPN 4 way, 240 V, 50 Hz double door with neutral, Earthing bar and din rail complete all as specified and directed.
Supply and fix in reapir/replacement MCB TP/TPN 50 to 63 Amps, 10 KA, 240 volts "C" series complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 25 Sqmm 4 core mounted with clamps /fixed on wall with suitable size of saddles complete all as specified and directed by Engineer-in-Charge
Repair and Replacemet of Motor, Gear Box, Brake, control panel components and limit switch of EOT crane of capacity 2.0 Tonnes with span of 18.00 meter and hook lift 6.00 metre complete all as specified and directed. Note : The The Crane shall be completely overhauled to make it in working condition including testing with safe working load complete all as specified and directed.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground preferably in vertical position (Earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25×4 mm by means of bolts, nuts, check nuts and washers of galvanised iron including pit of PCC (1:2:4) type B-1, pre cast RCC cover slab of size 550x550x75mm, XPM reinforced not less than 1.60Kg/Sqm with suitable built in handle made from 12mm dia MS round bar, excavation and earth work in any type of soil, 20mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth lead wire upto 5m length, charcol, common salt complete all as shown in electric plate No 5 of SSR 2009 Part I connected to equipment, complete all as specified and testing on completion all as directed.
Supply, laying and testing cable XLPE insulated , screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable ( Heavy duty) 1100 volt grade with stranded aluminium conductor of size 120 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge
Excavation in trenches in any type of soil not exc 1.5m wide and n.exc 1.5m in depth for under ground electric power cables and getting out complete all as specified.
Returning, filling in. including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as specified
Removing excavated surplus material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point.
Sand cushioning to under ground cable laid in trenches for laying of LT UG cable 8 cm depth before laying the cable and 15 cm after laying and punned down to depth of 10 cm as per MES SSR Part -I ( 2009) all as specfied and directed. Note:- Punned thickness shall be measured and paid to the contractor.
Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat all as directed.
S&F in repair/replacement, commissioning and testing of outdoor cubical type LT Feeder piller box as per CPRI approved, IP-54 Protection for outdoor shell suitable for 415V,3 phase, 4 wire 50Hz, AC supply system fabricated from CRCA powder coated totally enclosed,Dust,Weather & vermin proof, 3.15 mm thick for outer shell having TPN aluminium busbar mounted in porcelain insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement and provn for incoming and outgoing cables with suitable glands including control wiring with minimum 2.5 sqmm PVC insulated copper conductor for measuring of voltage, amp with indicators RYB, Powder coated complete all as specified and directed by Engineer-in-Charge. Note:- Feeder piller box shall be mounted on 50x50x6 mm thick angle iron embedded in PCC 1:2:4,type B-I (Using 20mm gradewd stone aggregate) 30 cm deep and 45 cm above ground level. Danger notice plate should also be mounted on panel. angle iron shall be painted with two coat of synthetic enameled paint over a coat of red oxide primer. (a) MCCB 250 Amp 4 pole 35/36 KA Adjustable Thermal & Adjustable Magnetic setting Ics = 100% of Icu - 01 Nos. Make - Havells, /L&T/Seimens/Legrand (b) Onload Change over switch 250 Amp 4 Pole - 01 Nos. Make - Havells, /L&T/Seimens/Legrand (c) Alum bus bar 300 Amp TPN - 01 Set (d) Digital Multifuntional meter Showing V,I, PF , HZ etc with suitable CT ratio (e) Indicator lamp LED type (RYB) complete - 01 set (f) MCCB 4 Pole, 200 Amp, 35/36 KA,Adjustable Thermal & Adjustable Magnetic setting Ics = 100% of Icu - 02 Nos. Make - Havells, /L&T/Seimens/Legrand
Note:- Schedule of credit Rs. 24,504.50 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
Nitika electricals and engineers works
BMMJ TRADERS AND ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .