Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.4 LQualified Make: NUMERIC
Model: Numeric 5KVA Onfiniti G T ROAD AMRITSAR PUNJAB 143105 | AMRITSAR | PUNJAB | 143105 | Make: NUMERIC
Model: Numeric 5KVA Onfiniti | L1 | Qualified | |
| 2 | L2₹1.4 L+₹35 (0.03%)Qualified Make: NUMERIC
Model: NUMERIC ONFINITI 5.0KVA 118 118 BHAYANDER SHOPPING CENTRE OPP POLICE STATION STATION ROAD BHAYANDAR WEST BHAYANDER MAHARASHTRA 401101 | THANE | MAHARASHTRA | 401101 | Make: NUMERIC
Model: NUMERIC ONFINITI 5.0KVA | L2 | Qualified | |
| 3 | L4₹1.4 L+₹103 (0.07%)Qualified Make: NUMERIC
Model: NUMERIC ONFINITI 5.0KVA 01 TIWARI BAZAAR GONDA ROAD TIWARI BAZAAR GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | Make: NUMERIC
Model: NUMERIC ONFINITI 5.0KVA | L4 | Qualified | |
| 4 | Qualified Make: NUMERIC
Model: NUMERIC ONFINITI 5.0KVA | Make: NUMERIC
Model: NUMERIC ONFINITI 5.0KVA | - | Qualified | |
| 5 | L3₹1.4 L+₹83 (0.06%)Disqualified Make: microtek
Model: MICROTEK MAX SERIES 5 KVA NEAR SUKH CHAIN HOTEL JALANDHAR PUNJAB 144001 INDIA | JALANDHAR | PUNJAB | 144001 | Make: microtek
Model: MICROTEK MAX SERIES 5 KVA | L3 | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
5 Nov 2018, 4:00 pmClosed
Online UPS
Line Intractive UPS with AVR Experience with Gov. Required 5 Year (s) MSME Exemption For Years Of Experience And Turnover Yes Online UPS ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA * Technology IGBT-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer
IGBT- PWM with inbuilt isolation transformer
IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave
50Hz single phase 160V - 260V sinewave
50Hz
Three phase 300 V - 450V sinewave
50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz
3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz 1/6 Backup time (Minutes) 30 15
30
60
90
120
180
240 Minimum VAH (VAH) 6240 400-640000 Warranty for UPS (Years) 2 1
2
3
4
5 Movable trolly for Batteries Without trollery but with rack With
Without
Without trollery but with rack Warranty for battery 2 1
2 Degree of Protection IP20 IP21
IP20 Cabling 5 meters for input and out put With With
Without Paralleling kit for synchronising Without With
Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage
Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage
Output AC Volt age
Current
Frequency
Battery Voltage and Yes * 2/6 Current Indicators for mains presence
Battery charging and discharging
Output Over Load
Low Battery Voltage Yes * REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C
two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. NTH(SR)/EL(C)/2014/00 413D * Type Test Certificate date 02/12/2014 * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 3/6 1 Ankush Rana 143201
Mech Bde Beas Military Station Beas 1 90 Line Intractive UPS With AVR ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/168 * Technology MOSFET-PWM MOSFET-PWM
IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 Rated Output (Volt) Single phase sinewave 230v AC
50Hz Single phase sinewave 230v AC
Single Phase Quasi-Sin-wave 230 V AC
50 Hz Degree of protection IP 20 IP-21
IP 20 Inverter Efficiency (%) >/= 60% >/= 60%
>/= 70% Warranty for the battery from the date of delivery 1 year 1 year
3 Years Warranty for Line Interactive UPS 1 Year 1 Year
2 Years
5 Years
3 Years Installation and commissioning instructions Yes * CONSTRUCTIONAL Type of enclosure ABS * AC out put for printer (not through inverter) No Yes
No Inverter out put socket AC out put for printer (not through inverter) Not applicable 2 Three pin
3 Three pin
Hard wiring
Not applicable FUNCTIONAL Total harmonic distorsion (%) * Input (Volt) Single phase sinewave(160-280v) * Switching over time (Mili sec) Maximum 10 milli seconds * 4/6 Overload Time (Minutes) >/= 10 minutes * Load power factor >/= 0.6 * Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%
50 +/-3 Hz * Overload (%) >/=10% * Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% * Variation on output frequency in battery mode (Hz) =0.5 * PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 * Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts
the system shall switch over to battery mode Yes * Protection against short circuit of UPS Yes * Protection for over voltage and over load Yes * REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree
RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes * Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes * Cold Test as per IS:9000 pt-2/sec-4 Yes * Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes * Type Test certificate no. and date - * Name Of Lab - * 5/6 Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ankush Rana 143201
Mech Bde Beas Military Station Beas 1 90
786269
GEM/2018/B/110263
Online UPS,Line Intractive UPS with AVR
90 days
Punjab; Amritsar
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Online UPS | - | - | - |
| Line Intractive UPS with AVR Experience with Gov. Required 5 Year (s) MSME Exemption For Years Of Experience And Turnover Yes Online UPS ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA * Technology IGBT-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer | - | - | - |
| IGBT- PWM with inbuilt isolation transformer | - | - | - |
| IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave | - | - | - |
| 50Hz single phase 160V - 260V sinewave | - | - | - |
| 50Hz | - | - | - |
| Three phase 300 V - 450V sinewave | - | - | - |
| 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz | - | - | - |
| 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz 1/6 Backup time (Minutes) 30 15 | - | - | - |
| 30 | - | - | - |
| 60 | - | - | - |
| 90 | - | - | - |
| 120 | - | - | - |
| 180 | - | - | - |
| 240 Minimum VAH (VAH) 6240 400-640000 Warranty for UPS (Years) 2 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 Movable trolly for Batteries Without trollery but with rack With | - | - | - |
| Without | - | - | - |
| Without trollery but with rack Warranty for battery 2 1 | - | - | - |
| 2 Degree of Protection IP20 IP21 | - | - | - |
| IP20 Cabling 5 meters for input and out put With With | - | - | - |
| Without Paralleling kit for synchronising Without With | - | - | - |
| Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage | - | - | - |
| Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage | - | - | - |
| Output AC Volt age | - | - | - |
| Current | - | - | - |
| Frequency | - | - | - |
| Battery Voltage and Yes * 2/6 Current Indicators for mains presence | - | - | - |
| Battery charging and discharging | - | - | - |
| Output Over Load | - | - | - |
| Low Battery Voltage Yes * REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C | - | - | - |
| two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. NTH(SR)/EL(C)/2014/00 413D * Type Test Certificate date 02/12/2014 * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 3/6 1 Ankush Rana 143201 | - | - | - |
| Mech Bde Beas Military Station Beas 1 90 Line Intractive UPS With AVR ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/168 * Technology MOSFET-PWM MOSFET-PWM | - | - | - |
| IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 Rated Output (Volt) Single phase sinewave 230v AC | - | - | - |
| 50Hz Single phase sinewave 230v AC | - | - | - |
| Single Phase Quasi-Sin-wave 230 V AC | - | - | - |
| 50 Hz Degree of protection IP 20 IP-21 | - | - | - |
| IP 20 Inverter Efficiency (%) >/= 60% >/= 60% | - | - | - |
| >/= 70% Warranty for the battery from the date of delivery 1 year 1 year | - | - | - |
| 3 Years Warranty for Line Interactive UPS 1 Year 1 Year | - | - | - |
| 2 Years | - | - | - |
| 5 Years | - | - | - |
| 3 Years Installation and commissioning instructions Yes * CONSTRUCTIONAL Type of enclosure ABS * AC out put for printer (not through inverter) No Yes | - | - | - |
| No Inverter out put socket AC out put for printer (not through inverter) Not applicable 2 Three pin | - | - | - |
| 3 Three pin | - | - | - |
| Hard wiring | - | - | - |
| Not applicable FUNCTIONAL Total harmonic distorsion (%) * Input (Volt) Single phase sinewave(160-280v) * Switching over time (Mili sec) Maximum 10 milli seconds * 4/6 Overload Time (Minutes) >/= 10 minutes * Load power factor >/= 0.6 * Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9% | - | - | - |
| 50 +/-3 Hz * Overload (%) >/=10% * Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% * Variation on output frequency in battery mode (Hz) =0.5 * PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 * Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts | - | - | - |
| the system shall switch over to battery mode Yes * Protection against short circuit of UPS Yes * Protection for over voltage and over load Yes * REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree | - | - | - |
| RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes * Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes * Cold Test as per IS:9000 pt-2/sec-4 Yes * Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes * Type Test certificate no. and date - * Name Of Lab - * 5/6 Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ankush Rana 143201 | - | - | - |
| Mech Bde Beas Military Station Beas 1 90 | - | - | - |
Exempted
5 Nov 2018
26 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_786269.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .