| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.2 LAccepted-AOC | L1 | Accepted-AOC Accepted. Being the L1 bidder. | |
| 2 | L2₹38.9 L+₹3.8 L (10.7%)Rejected-AOC 64 A JASRAJ MANSION 1ST FLOOR OLD HANUMAN LANE KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L2 | Rejected-AOC Rejected as not being the lowest bidder. | |
| 3 | L3₹39.7 L+₹4.5 L (12.8%)Rejected-AOC FLAT NO A 402 SHANKAR HEIGHTS NEAR CHETANA SCHOOL HAJI MALANG ROAD KALYAN EAST THANE MUMBAI 421 306 | THANE | MAHARASHTRA | 421306 | L3 | Rejected-AOC Rejected as not being the lowest bidder. | |
| 4 | L4₹40.8 L+₹5.7 L (16.1%)Rejected-AOC BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L4 | Rejected-AOC Rejected as not being the lowest bidder. | |
| 5 | L5₹46.8 L+₹11.6 L (33.1%)Rejected-AOC | L5 | Rejected-AOC Rejected as not being the lowest bidder. |
| Sl No | Description | Qty | Unit | AGRAWAL ASSOCIATES L4 | Radha Engineering Services L5 | Shree Ayyappa Engineering L6 | M/s Mukesh Engineers L2 | GUPTA ENTERPRISES L3 | PAUL REFRIGERATION L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets and tube light fittings etc, removing materials from site or for reuse refixing and making good distrubed surface of wall, floors etc complete all as specified and directed. | 20 | Point | 5 ₹100 | 50 ₹1,000 | 20 ₹400 | 10 ₹200 | 10 ₹200 | 1 ₹20 Lowest |
| 2.00 | Taking down carefully copper/alumunium Sub main wiring from the position and removing materials from site or for reuse refixing and making good distrubed surface of wall, floors etc all complete all as specified and directed. | 760 | RM | 5 ₹3,800 | 10 ₹7,600 | 20 ₹15,200 | 10 ₹7,600 | 25 ₹19,000 | 1 ₹760 Lowest |
| 3.00 | M & L for point wiring complete with proper colour coding using 1100 volts grade, 1.5 Sqmm, PVC insulated, FRLS,unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked, drawn Completely in and including PVC casing caping fixed on the surfaces of Walls/RCC slab/ ceiling/columns/beams etc with all accessories, fittings, also inclduifng 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts mutli-stranded copper conductor green colour as continous earth wire connected to common earth dolly all as specified and diretced for one light point/fan point controlled by one one way switch, complete all as specified and directed. | 10 | point | 550 ₹5,500 | 750 ₹7,500 | 730 ₹7,300 | 700 ₹7,000 | 450 ₹4,500 Lowest | 500 ₹5,000 |
| 4.00 | M&L for point wiring complete with 1.5 sqmm PVC insulated unsheathed 1100 volts grade FRLS cable stranded copper conductor single core partly concealed in wall through Existing/Laying new PVC conduit(as directed by Engr-in-charge) and concealed accessories and partly surface on ceiling, beams and cloumns through casing caping and accessories of size 20/25mm complete with 1.5 sqmm PVC insulated copper conductor earth wire and connected to earth dolly for one light/Fan point controlled by one switch complete all as specified and directed. | 10 | Point | 1,000 ₹10,000 | 800 ₹8,000 | 800 ₹8,000 | 800 ₹8,000 | 650 ₹6,500 | 600 ₹6,000 Lowest |
| 5.00 | Supply and fix in replacement of switch modular type 6 amp single pole one way 230 V complete all as specified and directed. | 30 | Each | 35 ₹1,050 Lowest | 75 ₹2,250 | 160 ₹4,800 | 160 ₹4,800 | 35 ₹1,050 Lowest | 100 ₹3,000 |
| 6.00 | Supply and fix in replacement of switch modular type 16 amp single pole one way 230 V complete all as specified and directed. | 20 | Each | 90 ₹1,800 | 175 ₹3,500 | 210 ₹4,200 | 210 ₹4,200 | 60 ₹1,200 | 30 ₹600 Lowest |
| 7.00 | Supply and fix in replacement of ceiling rose surface backelite three terminal complete all as specified and directed. | 20 | Each | 35 ₹700 | 50 ₹1,000 | 50 ₹1,000 | 50 ₹1,000 | 25 ₹500 Lowest | 30 ₹600 |
| 8.00 | Supply & fixing Modular white cover plate with frame 8 Module complete all as specified and directed. | 10 | Each | 165 ₹1,650 | 300 ₹3,000 | 290 ₹2,900 | 290 ₹2,900 | 120 ₹1,200 Lowest | 200 ₹2,000 |
| 9.00 | Supply & fixing Modular white cover plate with frame 6 Module complete all as specified and directed. | 10 | Each | 125 ₹1,250 | 240 ₹2,400 | 260 ₹2,600 | 260 ₹2,600 | 80 ₹800 Lowest | 200 ₹2,000 |
| 10.00 | Supply & fixing Modular white cover plate with frame 3/4 Module complete all as specified and directed. | 15 | Each | 100 ₹1,500 | 180 ₹2,700 | 220 ₹3,300 | 220 ₹3,300 | 60 ₹900 Lowest | 200 ₹3,000 |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
28 Jan 2025, 6:00 pmClosed
GE (NW) BHANDUP
GE (NW) BHANDUP, MUMBAI
SPECIAL REPAIRS FOR REPLACEMENT OF LT UG CABLES AND UNSERVICEABLE LED LIGHT FITTINGS AND EARTING ALUMINIUM WIRING AT BLDG No P-24, P-106, P-151, P-153, P-161 AND P-209 AT INS HAMLA UNDER GE (NW) BHANDUP
2024_MES_688778_2
8369/B
Open Tender
Civil Works
Item Rate
180 days
HAMLA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (NW) BHANDUP
₹89,000
Yes
9 Sept 2025
8 Jan 2025
29 Jan 2025
8 Jan 2025
28 Jan 2025
14 Jan 2025
8 Jan 2025 - 10 Jan 2025
Amount
Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets and tube light fittings etc, removing materials from site or for reuse refixing and making good distrubed surface of wall, floors etc complete all as specified and directed.
Taking down carefully copper/alumunium Sub main wiring from the position and removing materials from site or for reuse refixing and making good distrubed surface of wall, floors etc all complete all as specified and directed.
M & L for point wiring complete with proper colour coding using 1100 volts grade, 1.5 Sqmm, PVC insulated, FRLS,unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked, drawn Completely in and including PVC casing caping fixed on the surfaces of Walls/RCC slab/ ceiling/columns/beams etc with all accessories, fittings, also inclduifng 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts mutli-stranded copper conductor green colour as continous earth wire connected to common earth dolly all as specified and diretced for one light point/fan point controlled by one one way switch, complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated unsheathed 1100 volts grade FRLS cable stranded copper conductor single core partly concealed in wall through Existing/Laying new PVC conduit(as directed by Engr-in-charge) and concealed accessories and partly surface on ceiling, beams and cloumns through casing caping and accessories of size 20/25mm complete with 1.5 sqmm PVC insulated copper conductor earth wire and connected to earth dolly for one light/Fan point controlled by one switch complete all as specified and directed.
Supply and fix in replacement of switch modular type 6 amp single pole one way 230 V complete all as specified and directed.
Supply and fix in replacement of switch modular type 16 amp single pole one way 230 V complete all as specified and directed.
Supply and fix in replacement of ceiling rose surface backelite three terminal complete all as specified and directed.
Supply & fixing Modular white cover plate with frame 8 Module complete all as specified and directed.
Supply & fixing Modular white cover plate with frame 6 Module complete all as specified and directed.
Supply & fixing Modular white cover plate with frame 3/4 Module complete all as specified and directed.
Supply & fixing modular Plastic Surface PVC box 6/8 Module complete all as specified and directed.
Supply & fixing modular Plastic Surface PVC box 3/4 Module complete all as specified and directed.
M&L in repairs for sub main wiring two run of size 2.5 sqmm PVC insulated electric power FRLS cable (heavy duty) 1100 volts grade with stranded copper conductor with 2.5 sqmm PVC insulated copper conductor earth wire in PVC casing caping of suitable size (three run of 2.5 sqmm cable and one run of PVC conduit / casing caping will be measured as one unit) including dismantling of existing unserviceable submain wiring complete all as specified and directed.
M&L in repairs for sub main wiring two run of size 4 sqmm PVC insulated electric power FRLS cable (heavy duty) 1100 volts grade with stranded copper conductor with 4.0 sqmm PVC insulated copper conductor earth wire in casing caping of suitable size (three run of 4 sqmm cable and one run of PVC conduit / casing caping will be measured as one unit) including dismantling of existing unserviceable submain wiring complete all as specified and directed.
M&L in repairs for sub main wiring two run of size 6 sqmm PVC insulated electric power FRLS cable (heavy duty) 1100 volts grade with stranded copper conductor with 6 sqmm PVC insulated copper conductor earth wire in casing caping of suitable size (three run of 6 sqmm cable and one run of PVC conduit / casing caping will be measured as one unit) including dismantling of existing unserviceable submain wiring complete all as specified and directed.
M&L in repairs for sub main wiring Four run of size 10 sqmm PVC insulated electric power FRLS cable (heavy duty) 1100 volts grade with stranded copper conductor with 10 sqmm PVC insulated copper conductor earth wire in casing caping of suitable size (Five run of 10 sqmm cable and one run of PVC conduit / casing caping will be measured as one unit) including dismantling of existing unserviceable submain wiring complete all as specified and directed.
Supply and fixing in replacement surface mounting slim/Box type LED flat panel 2' x 2' LEDs 36/40 watts Inlcuding Replacement of Unserviceable LED Drivers and Multistrip LEDs Suitable to Fitted on False ceiling by cutting to complete all as specified and directed.
Supply and fixing in replacement of LED lamp with acrylic cover 14 watt Pin or Threaded CW/WW colour type complete all as specified and difected.
Supply and fixing in replacement round/Square shape 12 watt 230 volts AC recessed type down light with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. NOTE : Item must have 02 Years of onsite replacement warranty.
Supply and fixing in replacement round/Square shape 15/18 watt 230 volts AC recessed type down light with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. NOTE : Item must have 02 Years of onsite replacement warranty.
Supply and fixing in replacement 100 watt 230 volts AC High bay light with high efficiency having minimum 120 lumen/watt complete with drivers, suitable connection for hanging on ceiling with including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Note: Contractor must have arrange ladder for light installation.
Supply and fixing integrated sleek extruded LED channel with acrylic cover 20 watt LED Tube light fittings rated voltage 140V to 270V AC Driver efficiency 88% Lumen Efficiency 110 Lm/W, starting voltage 90V, THD < 20, colour rendering index > 80, colour Temperature 6500K, in built surge protection 2.5KV, Isolation 3.75 KV etc all as directed including with driver and prewired complete including 0.5 sqmm 3 core flexible wire connecting from ceiling rose complete all as specified and directed.
Supply and fixing integrated sleek extruded LED channel with acrylic cover 10 watt LED Tube light fittings rated voltage 140V to 270V AC Driver efficiency 88% Lumen Efficiency 110 Lm/W, starting voltage 90V, THD < 20, colour rendering index > 80, colour Temperature 6500K, in built surge protection 2.5KV, Isolation 3.75 KV etc all as directed including with driver and prewired complete including 0.5 sqmm 3 core flexible wire connecting from ceiling rose complete all as specified and directed.
Supply and fixing round shape 15 watt 230 volts AC recessed type down light with high efficiency PMMA diffuser soft glare free light rated voltage 140V to 270V AC Driver efficiency 88% Lumen Efficiency 100 Lm/W, starting voltage 90V, THD < 20, colour rendering index > 80, colour Temperature 6500K, in built surge protection 2.5KV, Isolation 3.75 KV etc complete all as specified and directed including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing round shape 18 watt 230 volts AC recessed type down light with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Suuply and fix in replacement of Exhaust fan Metal Lower (Flip cover outside) suitable for Exhaust fan 300 mm size 450 mm size over the out side surface of kitchen/ bathroom wall on building complete all as specified and direted. Note: The rate quoted by the contractor shall arrange ladder for fixing the lower at any height of floor of the building with necessary manpower.
Supply and fixing LED light fitting 2x20 watt flame proof, CMRI certified reccommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and direted.
S & F in replacement of U/s switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and direted.
Material and labour for earthing complete with GI earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground lavel) with top edge of the plate not less than 1.5mtr below normal ground lavel connected to GI earth strip 25 x 4 mm by mean of bolts, nuts, check nuts and washer of brash all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit and CI cover fullel with watering pipe, wire mess and copper lugs etc GI protection pipe 40 mm dia medium grade including testing on complete all as specified and directed.
Material and Labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe Connection with the existing earth chamber etc. with 25x4 mm size galvanised iron strip complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil for removing/laying of cables complete all as specified and as directed.
Returning, filling in including spreading , leveling , watering and well ramming in layers n.exc 25 cm with soil complete all as specified and as directed.
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for dry fine sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm thick after laying, stretching and testing the cable complete all as specified and directed. Note : [Punned thickness 18 cm shall be measured & paid]
Supply and laying DWC (Double Wall Corrugate) HDPE pipes of pressure rating 6 Kg/Cm sq of size 40 mm outer dia 32 mm inner dia minimum IS: 16205(Part 24) : 2018 laid in trenches complete all as specified and directed.
Supply and laying DWC (Double Wall Corrugate) HDPE pipes of pressure rating 6 Kg/Cm sq of size 50 mm outer dia 38 mm inner dia minimum IS: 16205(Part 24) : 2018 laid in trenches complete all as specified and directed.
Supply and laying un-reinforced pre cast concrete cable cover, class LV type 1 with flat size 250mm x 150mm x 40mm complete all as specified and direted.
Supply and laying GI pipe 50 mm, light grade for the protection of the cable passing through road crossing, etc complete all as specified and direted.
Supply and laying GI pipe 80 mm, light grade for the protection of the cable passing through road crossing, etc complete all as specified and direted.
Supply and laying in repairs cable LT XLPE insulated and screened PVC bedded, galvanised steel strip armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of size 95 Sqmm 3.5 Core complete all as specified and directed including taking down existing u/s LT cable. Note: It include cost of removing the old cable and fixing the new cable in panel/ required location with all lugs/cable clamp saddling if required e.t.c as directed.
All as per item No.40 above but for 70 sqmm 3.5 core
All as per item No.40 above but for 50 Sqmm 3.5 Core.
All as per item No.40 above but for 35 Sqmm 3.5 Core.
All as per item No.40 above but for 25 Sqmm 3.5 Core.
All as per item No.40 above but for 16 Sqmm 4 Core.
All as per item No.40 above but for 10 sqmm 2 core
Supply and fix in repairs LT cable route indicator made out of cast iron 10cm dia duly engraved with letters 'LT CABLE 1100 volts' fixed in 20mm x 20mm equal angle 60cm long including provision of PCC block of 20cm length x 20cm width x 30 cm depth complete all as specified and directed.
M & L for Premix Ready mix road repair patching Compound for repairs to damage road any depth,including sweeping free from dust and mud or water,scouring sunken surfaces in roads,paths etc,cutting around edges to at least 25 mm in depth,filling in screened and graded road metal,watering and well ramming etc complete all as specified and directed.(For Road Cutting Repair)
Material and labour for PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) for filling the disturbed road opening for cable crossing include levelling with road surface and smooth finishing complete all as specified and directed. ( for Road Cutting Repair)
Deduct Credit for Demolished/ Dismantled material Rs. (-) 2,17,046.65 (Minus) as listed in Schedule of Credit Note1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items.
M/s Mukesh Engineers (BID ID -3220730)
GUPTA ENTERPRISES (BID ID -3218795)
AGRAWAL ASSOCIATES (BID ID -3220419)
Radha Engineering Services (BID ID -3220541)
Shree Ayyappa Engineering (BID ID -3220600)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .