| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC | ₹20.5 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹22.9 L+₹2.4 L (11.7%)Rejected-AOC SALGAONKAR HOUSE DRIVERS HILL VASCO DA GAMA GOA 403802 | SOUTH GOA | GOA | 403802 | ₹22.9 L+₹2.4 L (11.7%) | L2 | Rejected-AOC Rejected |
Tender Value
₹23.7 L
EMD Value
₹47,340
Closing Date
12 Oct 2021, 5:00 pmClosed
GE GOMANTAK VASCO
GE GOMANTAK VASCO DA GAMA PIN 403802
Provision of Hard Wired Fencing Over Perimeter Wall at Various Places at 2W Det and Provision of Deficient Guard Detention Room at Sagar Gate at 2W Det Goa under GE Gomantak
2021_MES_474207_1
8320/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
VASCO DA GAMA
refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE GOMANTAK
₹47,340
Yes
2 Nov 2021
13 Sept 2021
13 Oct 2021
13 Sept 2021
12 Oct 2021
27 Sept 2021
Amount
Schedule 'A' Part I - B/R PORTION
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out hard/dense soil all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation for laying cables etc. pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/disintegrated rock all as specified and as directed
M&L for Cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete all as specified and as directed.
M&L for TMT bars 10mm dia & over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed
Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed
Use & waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar complete all as specified and directed
Use & waste of formwork to sides of pilars,posts, struts, piers, columns and stanchions, rough finished surfacdes of concrete all as specified
Formwork to sides and soffits of roof beams, beam haunchings, girders, bressummers, including supports, overhangs, etc. also splays between floors and beams, etc.complete all as specified and directed
Use & waste of Formwork to chajjas, incl edges and similar work; not exceeding 200mm thick (Horizontal or sloping) all as specified and directed
Use & waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) all as specified and directed
M&L for RCC (1:1½:3) using (20mm graded stone aggregate) as in foundations footing, plinth beams, bases for columns and basement slab, under reamed piles and mass concrete complete all as specified.
M&L for RCC(1:1½:3) using (20mm graded stone aggregate) as in columns, pillars, posts & struts complete all as specified.
M&L for RCC (1:1½:3) using (20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified.
M&L for RCC (1:1½:3) using (20mm graded stone aggregate) as in chajjs complete all as specified.
M&L for RCC (1:1½:3) using (20mm graded stone aggregate) as in roof slab supported on walls, beams and columns (Horizontal or sloping) complete all as specified.
M&L for Pre-cast cement concrete type C1 (1:3;6) block masonry with solid blocks, exc. 10 cm in width and setting in mortar (1:4) complete all as specified and as directed.
M&L for Pre-cast cement concrete type C1 (1:3;6) block masonry with solid blocks, 10 cm in width and setting in mortar (1:4) complete all as specified and as directed.
Returning filling in including spreading levelling watering and well ramming inlayers n.exc. 25 cm in rocks all as specified and as directed..
Removing excavated materials (soft/dis integrated rockl) to a distance n.exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed
M & L Hard core, broken stone or boulders of gauge n exc 63 mm, diposited, spread and levelled in layers n exc 15mm thick, watered and rammed to a true surfaces complete all as specified and directed.
M&L 75 mm thick cement concrete type, C2 1:3:6 using (40 mm graded aggregate) as in plinth protection finish the surface even and smooth all as specified and as directed.
M&L for PCC (1:4:8) type D-2 (using 40mm graded aggregates) as in sub base floor 75mm thick all as specified & directed
M&L for Vitrified ceramic tiles light shed 10 mm thick (square/rectangular) polished area of each tiles not exceeding 0.36 sqm but in floors etc set & jointed in neat cement slurry & pointed in white or coloured cement with pigment to match including 15 mm thick screed bed (1:4) CM as specified & directed
M&L Screed bed or bedding layer of mortar 15 mm thick for laying floor finish CM: 1:4 all as specified and as directed.
M&L Non - skid colour Ceramic tiles 7 to 8 mm thick quare/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.16 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 20mm thick screed in CM (1:4) complete all as specified and directed.
M & L rendering cement plaster 10 mm thick with CM 1:4 as packing coat to receive tiles on vertical surfaces all as specified and directed.
M & L Glazed ceramic tiles in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match (coloured tiles)all as specified and directed.
M&L rendering cement plaster 1:4 , 15 mm thick on fair faces of brick work or concrete surfaces finshed even and smooth without using extra cement.
M & L 15 ( 10+5) mm thick rendering in two layer on fair faces of concrete in CM 1:4 finish the surface even & smooth without using extra cement complete all as specified and directed ( NOTE : II nd coat 5mm thick with WPC )
M & L 5 mm thick rendering on on soffit of slab in CM 1:3 finish the surface even & smooth without using extra cement complete all as specified and directed
M & L for rendering in CM 1:3, 10 mm thickness on roof slab finishing the surface even and fair with out using extra cement complete all as specified and directed.
Supply only Liquid water proofing compound.
S & F water proofing treatment to the roof slab and chajja using 4mm thick APP modified membrane consisting five layer membrane with features as specified, weighing not less than 4.0 kg/Sqm laid over a coat of cold applied bituminous primer @ 0.2 litre per Sqm on surface provide a layer of APP modified membrane by torching application including sealing the overlap with torching with 150 mm on length side and 100 mm on width side as per manufacturer's instruction including joints and changes in direction be covered with thin cement slurry in CM 1:3 mixed with SBR latex @ 200 ml/bag of cement curved well before laying of membrane all as per manufacturer's instructions and provide a finishing coat with solar reflective bituminous aluminium paint @ 0.10 kg/m2 as prescribed by manufacturer of membrane to the satisfaction of Engineer-in-Charge. Note:- 1. Irrespective of the lap the net covered area will only be measured for payment.
suppling & fixing in opening Solid PVC Door Frame of size 50mm x47mm made out of 5mm plain colourPVC sheet reinforced with M.S. Square tube, suppling & fixing in opening all as specified and as directed.
Supplying & fixing in frame at site Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, as per specification
M&L 2nd class hard wood plain solid straight chowkats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pined joints
M&L 35 mm thick 2nd class HW plain framed pannelled shutter (any number of panels) with panels of timber flat on both sides or of veneered particle board medium density , wood particle board with commercial face veneers , supplied and fitted to chowkats.
M&L for preparation of new untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.
Supply and fix 35mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Sec-tion 8, clause 8.24 (a) complete all as specified and as directed.
S&F 100mm long Stainless steel Butt hinges fixed to door frame.
S&F 200mm long Aluminium anodised, barrel tower bolts of extruded section and fixed
S&F 150mm long Fancy type Aluminium handles, cast type, anodised
S&F 200mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S & F powder coated (50 micron) window or ventilator shutter and frame any type (slidding or openable) with frame or other similar work etc section fabricated by using the JINDAL/ INDAL /HINDALCO /sections including necessary roller,wheel cleat handals locking arrangements also to receive 4.8mm thick glass with aluminum chanel beading and stainless steel scrw including and rubber gasket beading etc complete (the weight of rubber gasket beading will not be measured with the weight of aluminum shuter glass will be measured and paid separately)All scections as approved by GE
S&F 4.8 mm thick Sheet glass, ordinary quality and glazing with oil putty/rubber beading in square/Rectangular n exc 0.5 sq. m in each pane.complete all as specified and directed
S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed
Supply and fixing as in replacement for vitreoues china WHB, white, flat back, of size 550x400mm including CP brackets, CP waste coupling 32 mm bore, PVC waste pipe 32mm dia with and including 15mm bore PVC connection pipe 450mm long with PTMT nuts at both ends complete all as specified and as directed.
S&F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern, flush pipe ) and incl waste pipe Urinal all as specified and as directed
S & F of Vitreous china squatting pan of "Orissa pattern", size 580x440mm white, with integral foot rests, fixed complete all as specified and as directed
S & F PVC valve less, syphonic action type, flushing cistern, 10 litres, low level, white, with inlet, ball valve, float and handle including brackets and connections to pipes complete all as specified and directed
S&F 25mm Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to , ceilings or in floors etc., any type of pipe all as specified and as directed
S&F 15mm Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to conseled in walls walls, ceilings or in floors etc., any type of pipe all as specified and as directed
S & F 15 mm dia Angle stop valve fancy type, chromium plated screwed both ends for iron pipe or for unions.
S & F 15 mm dia pillar taps fancy, chromium plated, screw down high pressure, screwed for iron pipe.
S&F 15mm dia chromium plated Bib taps , screwed for iron pipe. Complete all as directed
S&F Push tap any colour high pressure of PTMT screwed for iron pipe and fixed, suitable for urinals, (Minimum weight 15mm-50gms)
S & F PVC connections 15 mm size with PTMT nuts of length 450m fixed in repairs.
S&F 500 Ltrs Rotational moulded polyethylene water storage tanks sintex (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed
S&F 25mm dia Stop valve of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 25mm- 92gms) complete all as specified and directed
S&F Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms) complete all as specified and directed
S&F Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) complete all as specified and directed
Shower arm 15 mm size, 195mm long with bend of 45 degree with flange of PTMT any colour.(Minimum weight 40gms) complete all as specified and directed
S&F 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and as directed
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement all as specified and as directed
M & L for three coats of white wash on newly plastered celing surfaces all as specified and as directed.
M & L for three coats of white wash on newly plastered wall surfaces all as specified and as directed .
M&L for preparation of new plastered surface & applying two coats of oil bound distemper (OBD) over a coat of white chalktening on wall complete all as specified and directed by Engineer-in-charge.
M & L preparation of new plasterd surfaces on wall and applying two coats of cement base paint over one coat of primer all as specified and directed by Engr in charge.
Sand cushning 50 mm thick spread, levelled, compacted to receive interlocking tiles all as specified and as directed.
Machine pressed pre cast concrete interlocking paver blocks (with grey cement and pigment) any shape and size conforming to IS-15658-2006 of 60 mm thicknes,M-35 grade all as specified and as directed.
M&L Providing precast cement concrete (1:2:4) using 20mm graded stone aggregate , solid blocks of size 400x300x100mm for kerb stone (with plain or interlocking joints as directed) set in CM (1:4) all as specified and as directed.
Excavation in trenches, n.exc. 1.5 m wide and n.exc. 1.5 m in depth, for foundation etc, or manholes etc for laying of GI pipe and cables etc and getting out in hard soil all as specified and as directed...
M&L plain cement concrete in benching (surface channels and drains) type B1 1:2:4 (20 mm graded stone aggregate).all as specified and as directed.
M&L plain cement concrete type B1 1:2:4 (ung 20 mm graded stone aggregate) in coping, incl weathering, slighntly rounded or chamferred angle and throating, as directed.
M&L Providing pre cast cement concrete type B1 1:2:4 (20 mm graded aggregate) in manhole cover slabs set in cement mortar 1:6 including necessary form work all as specified and as directed.
S&F 150 mm dia PVC (SWR) pipes single socketed in any length with rubber rings joints laid in trenches all as specified and as directed..
M & L concrete bed, type C-2, 1:3:6 for drain pipes including packing under and haunching against the des of pipes after they are laid and tested for150mm pipes all as specified and as directed.
S&F 110 mm dia PVC (SWR) vent pipes single socketed in any length with rubber rings joints all as specified and as directed..
S & F 110 mm dia PVC (SWR) vent cowl .
S & F only Septic tank hume pipe 10 users capacity exc. in soft dintegrated rock,pcc filling etc including RFR and disposal of surplus spoil complete.
Construction of Soakage well 1.8m dia and 3.0m deep , Excavation in hard soil/ Soft Rock. Foundation with PCC (1:3:6) , Fly ash brick work in CM (1:4), RCC cover slab incl Precast Manhole cover , and filling with brick bats complete.
Dismantling Concrete of any description and in any position not otherwise specifically provided for cement concrete is reinforced (reinforcement cut as required to facilitate demolition) all as specified and directed by Engr in charge.
Demolition of Brick work or stone/boulder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but excluding ashlarfacings, dressed stonework and precast concrete articles all as specified and directed by Engr in charge.
S&F mild steel work such as in angle iron, flat iron fillets etc for horn, fixing of barbed wire to Angle Iron post, securing wire mesh etc. including all necessary cuttings, drilling, bolting or riveting etc including necessary welding where required, as per site requirement and other similar works complete, conforming to Fe-290 Gde E-165
M&L for PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases)and including necessary form work complete all as specified and directed.
M&L for broken glass coping on top of walls in CM 1:3 @ 10 kg broken glass/Sqm.
M&L for preparation of new steel surfaces of any description over 10 cm in width or girth & applying two coat of synthetic enamelled paint over one coat of red oxide paint complete all as specified.
S&F galvanised 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc as directed. Note :- Each line of horizontal / vertical / diagonal wire to be measured for the purpose of payment.
M&L for Concetrina coil securing or tying incl provn of MS wire stapples or steel pins etc all as specified & directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/ disintegrated rock complete all as specified and as directed.
M & L 10 mm thick rendering on fair faces of concrete in CM 1:6 finish the surface even & smooth without using extra cement coplete all as specified and directed.
S&F TMT bars 8mm dia cut to lengthbent to shape required incl cranking, binding with and including MS wire not less than 0.9mm dia all as specified and as directed.
Removing excavated materials (soft rockl) exc 50m n.exc. 100m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed
M&L for Pre-cast cement concrete block masonary type C1 (1:3;6) (20mm graded stone aggregate) set in cement mortar (1:6) all as specified and as directed.
Schedule 'A' Part I - E/M PORTION
Material and labour for point wiring complete as specified with 1100 V grade 1.5 Sqmm single core PVC insulated unsheathed multistranded copper conductor cable FRLS grade, conforming to relevant IS, drawn through and including PVC conduit with all accessories concealed in wall/ceiling , including sunken pressed steel terminal boxes made out of 2 mm thick MS sheet concealed in walls with 3 mm thick laminated Hylem sheet top cover fixed with brass screws for housing switches, socket, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed mulitistranded copper conductor cable FRLS grade as earth continuity wire connected to common earth and earth dolly including testing complete all as specified and directed by Engr-in-Charge for the following.
(a) One light/fan/exhaust fan point controlled by one switch.
(b) One 5 pin switch socket outlet 5 Amps on independent board controlled by one switch.
Material and labour for point wiring complete as specified with 1100 V grade 4 Sqmm single core PVC insulated unsheathed multistranded copper conductor cable FRLS grade, conforming to relevant IS drawn through andincluding PVC conduit with all accessories concealed in wall/Ceiling including sunk pressed steel terminal boxes made out of 2 mm thick MS sheet concealed in walls with 3 mm thick laminated Hylem sheet top cover fixed with brass screws for housing switches, socket etc including 4 Sqmm single core PVC insulated and unsheathed copper conductor cable FR grade as earth continuity wire connected to common earth and earth dolly including testing complete all as specified and directed by Engr-in-Charge for one 6 pin switch socket outlet 15 Amps on independent board controlled by one switch.
Supply and fix switch piano flush type single pole, one way 5 Amp.
Supply and fix switch socket combination 2 in 1, 5 pin, 5 Amp flush type universal.
Supply and fix switch socket combination 2 in 1, 5 pin, 15 Amp flush type universal.
Supply and fixing LED Batten 25W 4 ft tube complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable . Make : Philips Equivalent in Bajaj/Havells.
Supply and fixing LED Stellar brite linear 10W bulb complete with swivel body action for better focus etc. complete . Make : Philips or Equivalent in Bajaj/Havells.
Supply and fixing lamp holder, PVC/Polycarbonate type with black plate suitable for batten fittings complete all as directed by Engr-in-charge.Make: Anchor
Supply and fix stepped type electronic fan regulator flush type complete as directed.
Supply and fix sheet metal enclosure (DB) for MCB's, 8 way, single pole and neutral, 240 volts, double door with 100 Amp rated Copper bus bar with IP 54- IK 09 complete.
Supply and fix MCB, single pole, 6- 32 Amp, 240 Volts, 'C' Curve 10KA. Make: Legrand ( DX3)/C&S/Schneider
Supply and fix MCB, single pole and neutral, 6-32 Amp, 240 Volts, 'C' Curve 10 KA.Make: Legrand ( DX3)/C&S/Schneider
Supply and fix ceiling rose, surface bakelite, 65x50 mm, two to three terminals complete.
Supply & fixing in repairs Brushless DC Motor (BLDC) ceiling fan 1200mm sweep, 5 star rated (ISI Marked), 230 volts least power consuming fan of 26W, having PCB Housing in the bottom canopy including connection rod as per existing size of length of GI pipe medium grade complete all as per specified and directed. Make : Usha/Havells/Bajaj
S&F exhaust fan (Metal body) AC single phase 230/240 V of size 225/230 mm sweep with louvres and provn of flexible copper cord from ceiling rose to ext fan Complete all as specified & directed by Eng-in charge. Make : Havells/Bajaj/Crompton
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and other end of earth wire connected to main switch board and protected by galvanised iron pipe light grade 15mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover with handle all as specified and shown in elect plate No 3 of SSR Part-I of 2009 complete all as specified and directed. NOTE :- (i) The concrete pit shall be PCC (1:3:6) type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) The unit rate includes the cost of GI pipe medium grade for protection of earth wire and 4mm dia earh lead wire upto 7.5 M. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself.
Supply and fix submain wiring with 2 runs of 6 sqmm, FRLS PVC insulated, unsheathed, single core, multi stranded, 1100 Volts, copper conductor cable drawn in and including suitable size PVC conduit with all accessories such as tees, elbows, junction box, reducers etc concealed in wall as required along with 1 run of 6 sqmm FRLS PVC insulated, unsheathed, single core, multi stranded copper conductor cable as continuous earth wire and connecting to main switch board \ Distribution Board and testing on completion complete all as directed by Engineer-in-charge. Note : 2 runs of 6 Sqmm cable, 1 run of 4 Sqmm PVC insulated, unsheathed, single core, multi stranded copper conductor cable and 1 run of PVC conduit of suitable size shall be measured as single run. Make: Finolex/ Havells/polycab
Supply & Fixing integrated LED Bulk Head fitting surface/ceiling mounted round/square type with LED 10 watts ,IP 65 complete Make : Philips/Wipro/Bajaj/Havells
Supply, Laying, joining & testing LT XLPE Insulated & sheathed armoured electric cables with multistranded aluminium conductor cable 1100 volts grade, laid in trenches/ ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes & aluminium lugs for connection for cross- sectional area 25 Sq mm 2 Core complete all as specified and directed.
M & L for fine river sand for cushioning in layers of sand 8 cm before laying of cable & 15 cm after laying of cable (total 23 cm ) in trenches, duly punning to a thickness of 18 cm for cable protection complete all as directed and specified. Note:- Thickness after punning shall be measured for payment
Supply and lay PCC cable cover class LV type 1 flat size 250mmx150mmx40mm for protection cover to under ground cable.
Supply and fix GI tubing (light grade) with all fittings,laid in trenches, or fixed along with walls /poles,bore of pipe 50mm.
Supply and laying GI tubings medium grade dia ISI Mark with all fittings such as elbow, bends, sockets, nipples and union etc and fixed complete laid in trench/wall for the 25 mm dia all as specified and directed by Engr-in-charge :- (Make : TATA/JINDAL/Prakash Suriya as Equvailent)
All as per item No 118 here in above but for 20mmdia GI pipe.
Supply and Fixing Gun metal Globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed in 20 mm dia pipe complete all as specified & directed by Eng-in-charge.
Tara Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .