PROVISION OF CHANGE OVER SWITCH FOR MRI, ALUMINUM PARTITIONS,RO PLANT FOR CSSD AND CURTAIN PARTITIONS AT AIIMS BIBINAGAR, TELANGANA
2024_AIIBB_801193_2
AIIMS/BBN/SE/09/2023-24
Open Tender
Civil Works - Buildings
Item Rate
180 days
AIIMS Bibinagar Yadadri Bhongiri
As per Tender Documents
2 documents required · 2 mandatory
₹500
Yes
All india Institute of Medical Sciences Bibinagar
₹1.1 L
SE Office, AIIMS Bibinagar
7 May 2024
15 Apr 2024
23 Apr 2024
15 Apr 2024
22 Apr 2024
15 Apr 2024
15 Apr 2024 - 22 Apr 2024
19 Apr 2024
Amount
RO Plant for CSSD
Primary RO Plant: Supply, Installation, Testing and commissioning of 2000 Liters Per Hour capacity Automatic RO Water treatment plant with all necessary fittings and accessories including RAW WATER TANK HDPE (2000L)-2 Nos, FEEDPUMP (1.5 HP) -1No, PRESSURE VESSELS (16 Inch X65 Inch) (for CARBON and SAND) -2Nos, CARBON and SAND Bags as required, MULTIPORT VALVE (MANUAL) -2Nos, MICRON FILTER HOUSINGS (4inch dia 20 inch length) -2No, HIGH-PRESSURE PUMP(4/3HP)-1No, MEMBRANE HOUSING (80X40) - 2Nos, PANEL BOARD -1No, MEMBRANE (8 inch), LINE MOUNT PRESSURE GUAGES, PANEL MOUNT PRESSURE GUAGE, SS SKIDS, ROTA METERS, MICRON FILTERS, PLUMBING, FLOAT SENSOR – 2 Nos, SOLENOID VALVE-2 Nos, DOSING PUMP (6 LPH)-1 No, PLANT WIRING, DOSING TANK(50L), DISTRIBUTION SYSTEM, HDPE WATER TANK (Capacity 2000 L)-1No. The TDS in the filtered water from primary RO (output water) should be preferable below 20ppm and should not be greater 40ppm. The output water is connected to secondary RO Plant as a input source for secondary RO plant in a series. Refer makes and schematic diagram in the tender document. Secondary RO Plant: Supply, Installation, Testing and commissioning of 2000 Liters Per Hour capacity Automatic RO Water treatment plant with all necessary fittings and accessories including RAW WATER TANK HDPE (2000L)-2 Nos, FEEDPUMP (1 HP) -1No, MICRON FILTER HOUSINGS (4inch dia 20 inch length) -2No, HIGH-PRESSURE PUMP(2HP)-1No, MEMBRANE HOUSING (80X40) - 2Nos, PANEL BOARD -1No, MEMBRANE (8 inch), LINE MOUNT PRESSURE GUAGES, PANEL MOUNT PRESSURE GUAGE, SS SKIDS, ROTA METERS, MICRON FILTERS, PLUMBING, FLOAT SENSOR – 2 Nos, SOLENOID VALVE-2 Nos, DOSING PUMP (6 LPH)-1 No, PLANT WIRING, DOSING TANK(50L), DISTRIBUTION SYSTEM, SS TANK with mounting stand (Capacity 2000 L)-1No The TDS in the filtered water from Secondary RO (output water) should be below 1 ppm and should not be greater 2 ppm. Electrical conductivity less than 5
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 20 mm nominal diameter pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
Providing and fixing 20 mm nominal bore ball valve (brass) of approved quality, High or low pressure, with plastic floats complete
Providing and fixing uplasticised PVC 30 cm length 20 mm nominl bore connection pipe with brass unions.
Providing and fixing uplasticised PVC 45 cm length 20 mm nominl bore connection pipe with brass unions.
Supplying and drawing 3 core x 4 sq.mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40A rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply & Installation of Hospital/ICU Partition Curtains with all respect as follows
Track Track Material Made of Aluminium alloy ( 6063-T6), with corrosion resistance properties and Standard white powder coating Track Size (Approximate), Track Gauge 1.7mm,Track Height 25 to 28 mm, Track Width 20 to 22mm, Runner type Wheel Type Roller Runner Runner material Teflon with Stainless steel 202 Hook, Hooks Stainless Steel 202, Bends Tracks are bendable to a radium of 300 mm at 90 degree to cover the whole bed, Track height As per site requirement , Track roof Made of aluminium pipe of more than 12 mm diameter and the Upper Circular Plate made of aluminium with at least 50 mm diameter. These suspenders should be white powder Coated and fixed with the ceiling with anchors, bolts, screws etc. Track wall supports Aluminium white Powder coated, Tack bridge clamp Aluminium white Powder coated, Curtain Removal Point Made of SS for simple loading & unloading of curtains. (Also serves as 11 an end hook Retainer. Curtain Material Polyester Blended, Standard Curtain Size: Curtain Height At least 84 inch or more, Width As per site conditions Mesh(Net) Size At least 16 inch or more from top of the curtain and made of nylon ,Curtains Type:Stain Retardant Cubicle Curtains These Curtains should be of specially coated fabrics which do not allow any bacteria to hold on it. These curtains should be wrinkle free and shrink proof with Anti odor And Anti fungal properties. It should meet the international Antimicrobial Test JISL 1902/ISO 20743 These Curtains should have stain retardant qualities with water repellent Quality with rust proof SS grommets 6" on centers. Designs and colours should be approved by the user department.
Supply & Installation of Change Over switch (manual)
Change over Switch: 630 AMPs 4 pole Changeover switch with panel box
Supply of 3.5 Core X 300 sq mm PVC sheathed / XLPE power cable of 1.1 KV grade
Supplying and making termination with heavy duty single compression brass gland , heavy duty aluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required size of 3.5 Core X 300 sq mm
Supply and laying of GI strip for body earthing
Installation for Change over Switch: 630 AMPs 4 pole Changeover switch with panel box
Charge for disconnecting of Existing connections from 250 Kva AMF Panel
charge for Removing and re laying load cables from 250 Kva AMF Panel to change over switch panel
Laying charges of 3.5 Core X 300 sq mm PVC sheathed / XLPE power cable in existing trenches
Aluminium Partition
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS:733 and IS:185, fixing wirh dash fasterners of required dia and size, including necessary filling up the gaps at junctions, i.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Alumium sections shall be smooth, rust free, straight mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P brass/stainless steel screws, all complete as per architectural drawing and the directions of engineer-in-charge. (Glazing, Paneling and dash fasteners to be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of door, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting whereever required including the cost of EPDM rubber/neoprene gasket required (Fitting shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade-I Type II, in panelling fixed in alluminium doors, windows, shutters and partitions frame with C.P brass/stainless steel screw etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides.
Providing and fixing glazing in aluminium door, window, ventilator shutter and partitions etc. With EPDM rubber/neoprene gasket etc. Complete as per the architectural drawing and the directions of Engineer-in-charge (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS :3564. EMBOSSED ON THE BODY, DOOR WEIGHT UPTO 36 KG TO 80 KG AND DOOR WIDTH FROM 701 MM TO 1000MM), WITH DOUBLE SPEED SPPED ADJUSTMENT WITH NECESSARY ACCESSORIES AND SCREWS ETC COMPLETE.
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc, complete : 300x16 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. Complete : 250x10mm Vide page No CMB
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, witj necessary screws etc. Complete : 125mm
Providing and fixing aluminium hanging fllor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. Complete, single rubber stopper.
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness
Replacement of 70W-80W LED Existing Street light body made of high grade pressure die-cast aluminum alloy with corrosion resistant powder coat, having protective toughened glass cover, Less glare IP 66 (silicon gasket ensures Optical & Electrical compartment are IP66) protected, Universal voltage 100-270V AC, P.F> 0.90, High power LED's having efficiency> 120 Lumens/watt, junction temperature < 75 °C with Ingress protection IP66 Driver surge protection 4KV, & IEC 60598-1, IEC 60529 and ISO certified, size 235mm X 75mm X 365mm (L X W X H) , Max Boom dia 68mm company and fixing of luminair to existing pole setup height of upto 30 feet. Price including scaffolding or Street Light Repairing lift/crane/vehicle charges etc. complete. Make: HPL, Philips, Havells, Wipro.
Replacement of 120-150W LED Existing Pole, body made of high grade pressure die-cast aluminum alloy with corrosion resistant powder coat, having protective toughened glass cover, Less glare IP 66 (silicon gasket ensures Optical & Electrical compartment are IP66) protected, Universal voltage 100-270V AC, P.F> 0.90-0.95, High power LED's having efficiency> 130 Lumens/watt, junction temperature < 75 °C with Ingress protection IP66 Driver surge protection 4KV, & IEC 60598-1, IEC 60529 and ISO certified, company and fixing of luminair to existing pole setup. Price including scaffolding or Street Light Repairing lift/crane/vehicle charges etc., complete. Make: HPL, Philips, Havells, Wipro
VIJAYA REFRIGERATION N ELECTRICALS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .