Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L1 | Accepted-AOC Being the lowest tenderer and fulfilling all the criteria | |
| 2 | L2₹32.1 L+₹1.4 L (4.48%)Rejected-Finance NO 6 1 ALAGAR PERUMAL KOIL MAIN STREET VADAPALANI CHENNAI 600 026 | CHENNAI | CHENNAI | TAMIL NADU | 600026 | L2 | Rejected-Finance Not being the lowest tenderer | |
| 3 | L3₹32.7 L+₹2.0 L (6.41%)Rejected-Finance 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L3 | Rejected-Finance Not being the lowest tenderer | |
| 4 | L4₹33.5 L+₹2.8 L (9.20%)Rejected-Finance 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L4 | Rejected-Finance Not being the lowest tenderer | |
| 5 | L5₹39.8 L+₹9.1 L (29.6%)Rejected-Finance 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | L5 | Rejected-Finance Not being the lowest tenderer |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
12 Mar 2022, 6:00 pmClosed
Garrison Engineer Chennai
Garrison Engineer. Fort Saint George, Chennai
REPAIRS REPLACEMENT OF INTERNAL ELECTRIFICATION INCLUDING ALL FITTINGS FIXTURES AND ALLIED WORKS AT ZONE D AREA UNDER GE CHENNAI
2022_MES_507736_1
8556/E8
Open Tender
Electrical and Maintenance Works
Item Rate
213 days
Fort Saint George
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Chennai
₹96,000
Yes
26 May 2022
12 Feb 2022
18 Mar 2022
12 Feb 2022
12 Mar 2022
26 Feb 2022
Amount
BOQ PUBLISED ON 16 FEB 2022
M&L for point wiring complete with 1.5sqmm (nominal area) PVC insulated unsheathed multistranded, (two run for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS -694 drawn through and including new non metallic rigid PVC conduit medium grade, ISI marked, 20mm bore with conduit accessories concealed In wall/ floor and fixed on ceiling/ roof etc. including new pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provn of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly etc., complete all as specified and directed for:-
One light point controlled by one switch.
One fan point controlled by one switch through regulator.
One 3 pin socket outlet, 5amps on the same board with other switches controlled by one switch.
One 3 pin switch socket outlet, 5amps on independent board controlled by one switch.
One light point controlled by two No. 2 way switches.
One bell/ buzzer point controlled by one bell push.
M&L for point wiring complete with 2.5sqmm (nominal area) PVC insulated unsheathed multistranded, (two run for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS-694 drawn through and including new non metallic rigid PVC conduit medium grade, ISI marked, 20mm bore with conduit accessories concealed In wall/ floor and fixed on ceiling/ roof etc, including pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provn of 2.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly complete all as specified for one socket outlet (plug point) three pin 15 Amps controlled by one switch 15 Amps on independent board complete all as specified and directed.
M&L for point wiring complete with 1.5sqmm (nominal area) PVC insulated unsheathed multistranded, (two runs for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS -694 drawn through and including new PVC casing and capping of size 25 x 16mm with accessories fixed on surfaces of wall/ floor and fixed on ceiling/ roof etc, including pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provn of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly complete all as specified and directed for:-
One light point controlled by one switch
One fan point controlled by one switch through regulator.
One 3 pin socket outlet, 5amps on the same board with other switches controlled by one switch.
One 3 pin switch socket outlet, 5 Amps on independent board controlled by one switch
One light point controlled by two No. 2 way switches
One bell/ buzzer point controlled by one bell push
M&L for point wiring complete with 2.5sqmm (nominal area) PVC insulated unsheathed multistranded, (two runs for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS -694 drawn through and including PVC casing and capping of suitable size with accessories fixed on surfaces of wall/ floor and fixed on ceiling/ roof etc. including pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provn of 2.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly complete all as specified for one socket outlet (plug point) three pin 15 Amps controlled by one switch 15 Amps on independent board.
Taking down old unserviceable/ damaged point wiring carefully of any size and description on teak wood batten/ through pipe (light, fan, socket etc) including removal of battens, pipes/ conduits, sockets, switches, shades, ceiling fittings, bulk head fittings ceiling rose etc complete and making good disturbed portion of wall to match with the existing surface all as specified and directed.
Supply and fix switch piano, flush type, single pole, one way, 5 Amps, 230 volts all as specified and directed.
Supply and fix switch piano, flush type, single pole, two way, 5 Amps, 230 volts all as specified and directed.
Supply and fix switch piano, flush type, single pole, one way, 15 Amps, 230 volts all as specified and directed.
Supply and fix bell push, flush type, single pole, 5 Amps, AC, 230 volts all as specified and directed.
Supply and fix call bell of multi music type, single pole, AC, 230 volts including taking down old damaged Call Bell complete all as specified and directed.
Supply and fix socket outlet 2 in 1, 3 pin 5 Amps, 230 volts all as specified and directed.
Supply and fix socket outlet, 3 pin 15 Amps, flush type, 230 volts all as specified and directed.
Supply and fix switch socket combination, 2 in 1, 5 Amps, 230 volts flush type including taking down old damaged switch socket combination any type complete all as specified and directed.
Supply and fix switch socket combination flush type, 2 in 1, 15 Amps, flush type, 230 volts including taking down old damaged switch socket combination any type complete all as specified and directed.
Supply and fix switch socket combination flush type, 3 pin 15 Amps and 3 pin 5 Amps, 230 volts, 5 in 1, multipurpose, universal type including taking down old damaged switch socket combination any type complete all as specified and directed.
Supply and fix electronic ceiling fan regulator, dimmer type, 450 watts including taking down old damaged fan regulator any type complete all as specified and directed.
Supply and fix ceiling rose PVC/ Polycarbonate body 65 x 50mm 2 to 3 terminals 230 Volts, AC Single phase all as specified and directed.
Supply and fix lamp holder insulated body with back plate for batten fittings/ angle holder as required complete all as specified and directed.
Supply and fix modular switches suitable for AC 230V, 6 amps and including taking down of old damaged/ unserviceable switches complete all as specified and directed.
Supply and fix modular sockets suitable for AC 230V, 6 amps and including taking down of old damaged/ unserviceable switches complete all as specified and directed.
Supply and fix modular switches suitable for AC 230V, 16 amps and including taking down of old damaged/ unserviceable switches complete all as specified and directed.
Supply and fix modular power sockets suitable for AC 230V, 16 amps and including taking down of old damaged/ unserviceable switches complete all as specified and directed.
M&L taking down ceiling fan after dis-connecting the electric connection, opening, servicing & greasing, re-assemblig and hanging the same including making connections complete all as specified and directed.
Supply and fix 09 watts LED lamp including taking down fuse lamps complete all as specified and directed.
Supply and fix decorative 4 watt, 230 volts, 50 Hz wall mounting chrome finish fixture with opal glass diffuser complete all as specified and directed. Make: Havells Cat No. LHFOAIC1TZ1IO40 or equivalent of other specified makes.
Supply and fix decorative 9 watt, 230 volts, 50 Hz wall mounting chrome finish fixture with opal glass diffuser complete all as specified and directed. Make: Havells Cat No. LHFOAJE1TZ1IO60 or equivalent of other specified makes.
Supply and fix decorative 9 watt, 230 volts, 50 Hz wall mounting chrome finish fixture with opal glass diffuser complete all as specified and directed. Make: Havells Cat No. LHFOECE1TZ1B014 or equivalent of other specified makes.
Supply and fix decorative 9 watt, 230 volts, 50 Hz wall mounting chrome finish fixture with opal glass diffuser complete all as specified and directed. Make: Havells Cat No. LHFHCHE1TLW020 or equivalent of other specified makes.
Supply and fix 20 watts LED light fitting basic all purpose surface and wall mounted LED batten with aluminium housing and integrated electronic driver fixed on wall or ceiling surface including taking down old fitting complete all as specified and as directed. Make: C&S Cat No. LTTB4F20WLED/ W or equivalent from other makes specified in Particular Specifications.
Supply and fix 10 watts LED light fitting basic all purpose surface and wall mounted LED batten with aluminium housing and integrated electronic driver fixed on wall or ceiling surface including taking down old fitting complete all as specified and as directed. Make: C&S Cat No. LTTB2F10WLED/ W or equivalent from other makes specified in Particular Specifications.
Supply and fix environmental friendly, ultra modern, energy saving, surface mounted 10 Watts LED decorative oval bulkhead edge-lit LED luminaire comprising of high brightness including taking down the old fitting complete all as specified and directed. Make: C&S Cat No. SIRIUS/ 10W or equivalent of other specified makes.
Supply and fix 45 Watts environment friendly, new generation, aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source suitable for 2' x 2' grid ceiling including taking down the old fitting complete all as specified and directed. Make: C&S Cat No. LTCRSLM45WATT2X2 or equivalent of other specified makes. Note for item No. 24 to 32: The new fittings shall bear the CA No. and Year written by Black synthetic enamel paint using stencils or by permanent marker pen and the unit quoted shall be deemed to include the cost of writing these details.
M&L for submain wiring complete with two runs of 4.0 Sqmm single core, multistranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including new rigid non metallic PVC conduit medium grade ISI marked 25mm external dia concealed in wall/ floor along with conduit fittings and accessories, fixed on ceiling with one run of 4.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring with conduit any type complete all as specified. Note: Two runs of 4.0sqmm multistranded cable and one run of 4.0sqmm cable as earth continuity conductor alongwith PVC conduit shall be considered as one unit length.
M&L for submain wiring complete with two runs of 6.0 Sqmm single core, multistranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including new rigid non metallic PVC conduit medium grade ISI marked 25mm external dia concealed in wall/ floor along with conduit fittings and accessories, fixed on ceiling with one run of 6.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring with conduit any type complete all as specified. Note: Two runs of 6.0sqmm multistranded cable and one run of 6.0sqmm cable as earth continuity conductor alongwith PVC conduit shall be considered as one unit length.
M&L for submain wiring complete with four runs of 10 Sqmm single core, multistranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including new rigid non metallic PVC conduit medium grade ISI marked 32mm external dia fixed on walls/ floors/ ceilings etc., alongwith conduit fittings and accessories, with one run of 10 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring with conduit complete all as specified and directed. Note: Four runs of 10sqmm multistranded cable, one run of 10 sqmm cable and one run of PVC conduit shall be considered as one unit length.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 38, SPN, 8 way, 240 Volts, double door, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 13032 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall including taking down the existing one complete all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 38, SPN, 4 way, 240 Volts, double door, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 13032 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall including taking down the existing one complete all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 38, TPN, 8 way, 240 Volts, double door, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 13032 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall including taking down the existing one complete all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 38, TPN, 6 way, 240 Volts, double door, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 13032 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall including taking down the existing one complete all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 38, TPN, 4 way, 240 Volts, double door, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 13032 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall including taking down the existing one complete all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply, fix, connecting and testing isolator TPN, 100 Amps, 415 volts including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCB TPN, 63 Amps, 415 V of rupturing capacity 10kA, C curve type including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCB TPN, 40 Amps, 415 V of rupturing capacity 10kA, C curve type including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCB SPN, 63 Amps, 240 volts of rupturing capacity 10kA, C curve type including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCB SPN, 40 Amps, 240 volts of rupturing capacity 10kA, C curve type including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCB single pole (MCB SP), 40 Amps, 240 volts of rupturing capacity 10kA, C curve type including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCB single pole (MCB SP), 6 to 32 Amps, 240 volts of rupturing capacity 10kA, C curve type including taking down the existing one complete all as specified and directed.
Supply and fix single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 230 Volts including taking down old one complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x 6.0mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.5m below normal ground level, earth plate connected to galvanized iron earth wire of 4mm dia as earthing conductor by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES Schedule (Part I) (2009) connected to earth test point/ main switch/ DB/ Panel board all as specified or indicated including testing on completion with and including 15mm bore light grade GI protection pipe 7.5 meter long for earth strip including PCC (1:3:6), type C-1 pit with 40mm thick precast RCC (1:2:4), type B -1 cover reinforced with 12mm dia MS bars @ 150mm c/c both ways with lifting hooks made out of 12mm dia MS bars, wire mesh funnel with watering pipe 20mm dia light grade, common salt, charcoal filling in layers as specified, necessary excavation and earth work in any type of soil etc., complete all as specified and as directed.
Veera Electrical
RK ENTERPRISES
EVEREST ENGINEERING WORKS
M/s.Sai Agency
GK ENTERPRISES
M/s Jai Ganesh Engineering Solutions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .