| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAdmitted-Finance AH BLOCK AH157 NEW NO 6 3RD STREET ANNA NAGAR CHENNAI TAMIL NADU 600040 | CHENNAI | TAMIL NADU | 600040 | L1 | Admitted-Finance | |
| 2 | Rejected-Technical 16 2 GROUND FLOOR MUKUND LAL KATIYAL MARG ASHOK NAGAR WEST DELHI DELHI 110018 UDYAM DL 05 0005536 06AAECI7879J1ZY B 07AAECI7879J1ZW R 06AAECI7879J1ZY M MII STATUS AS NOT VERIFIED | WEST DELHI | DELHI | 110018 | - | Rejected-Technical Rejected | |
| 3 | Rejected-Technical | - | Rejected-Technical Rejected |
| Sl No | Description | Qty | Unit | GENETECHNOLOGIES L1 |
|---|---|---|---|---|
| 1.00Gel Documentation System | ||||
| 1.01 | 1. Versatile system to support wide range of applications like Fluorescence, Colorimetry/densitometry & Gel documentation.
2. The Gel Imaging System should support the following dyes – SYBR Green, SYBR Safe, Ethidium Bromide, Stain Free Gel, Coommassie Blue, Zinc Stain, Flamingo, Oriole, Silver Stain, Coommassie Fluor Orange, Sypro Ruby, Krypton & Colorimetric Blots
3. The Gel Imaging System should feature touch screen of size 9.7" or more which is Multitouch capable & offer a Display resolution of 1,024 x 768 pixels., 4. The Gel Imaging System should offer Smart Tray Technology that automatically recognizes your application-specific tray and adjust imaging parameters and software options accordingly, 5. The Gel Imaging System should offer precalibrated focus for any zoom setting or sample height. , 6. The Gel Imaging System should have a high-resolution scientific grade 16-bit CMOS camera, a light-tight compact darkroom & a Slide-Out UV Transilluminator., 7. Maximum image area - 21 x 14 cm (W x H). 8. Pixel density (gray levels) - 65535, 9. Dynamic range - >3.5 orders of magnitude, 10. Emission filter -535–645 nm, 11. Data output -16-bit or 8-bit: SCN, TIFF, JPEG image files, 12. The Gel Placement door should be drawer type allowing access to Gels from either direction for facilitating easy/clutter free gel excision applications., 13. The Imaging System should offer a camera resolution greater than 6.3 megapixels & carry a pixel size of 2.4 μm x 2.4 μm , 14. The Instrument should offer Trans-UV (B) and Epi White as Standard Illumination. White Light Trans Illumination should be included, 15. Appropriate flat fielding correction should be automatically and consistently applied to image data for every application.
Specifications of the Image Analysis Software:
1. Automated lane and band identification, molecular weight or base pairs evaluation, band sizing, and quantitation based on a reference band or quantity standards, 2. Snapshot tool to copy images, lane profiles, and graphs, 3. Allow Publishing resolution (dpi) and publishing dimension to be specified with a one-click image export for publication. Provides functionality to produce image at user-defined dpi and dimension, 4. No requirement of license for registration. The full version software should be installable in large number of computers. Lifetime free upgrades of Software & Firmware should be available, 5. Mac and PC compatible software, 6. 16-bit and 8-bit tiff images with a one-click export option, 7. Software should produce customizable reports with data organized as desired, including, Lane and band identification, molecular weight or base pair evaluation. Band sizing and quantification are based on a reference band or quantity standards., 8. Software should offer live update of results with any change of analysis parameters., 9. Local/Global background subtraction for individual bands' 10. Tools for compliance with U.S. FDA 21 CFR Part 11 regulations.
Warranty: Three years , Suitable Computer i5 processor, 8GB / 512GB SSD/Windows 11 Pro/USB Keyboard & Mouse | 1 | No | 5,08,474 ₹5,08,474 Lowest |
Tender Value
Refer Docs
EMD Value
₹11,800
Closing Date
17 Aug 2026, 3:00 pmClosed
The Registrar
Bharathiar University, Coimbatore
Equipment
2026_HE_689967_1
C7/CRTD/Bioinfor/DRDO/2284
Open Tender
Electrical Goods/Equipments
Supply
Bharathiar University
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹11,800
Yes
9 Oct 2026
31 Jul 2026
18 Aug 2026
31 Jul 2026
17 Aug 2026
31 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Gel Documentation System | |||||
| 1.01 | 1. Versatile system to support wide range of applications like Fluorescence, Colorimetry/densitometry & Gel documentation.
2. The Gel Imaging System should support the following dyes – SYBR Green, SYBR Safe, Ethidium Bromide, Stain Free Gel, Coommassie Blue, Zinc Stain, Flamingo, Oriole, Silver Stain, Coommassie Fluor Orange, Sypro Ruby, Krypton & Colorimetric Blots
3. The Gel Imaging System should feature touch screen of size 9.7" or more which is Multitouch capable & offer a Display resolution of 1,024 x 768 pixels., 4. The Gel Imaging System should offer Smart Tray Technology that automatically recognizes your application-specific tray and adjust imaging parameters and software options accordingly, 5. The Gel Imaging System should offer precalibrated focus for any zoom setting or sample height. , 6. The Gel Imaging System should have a high-resolution scientific grade 16-bit CMOS camera, a light-tight compact darkroom & a Slide-Out UV Transilluminator., 7. Maximum image area - 21 x 14 cm (W x H). 8. Pixel density (gray levels) - 65535, 9. Dynamic range - >3.5 orders of magnitude, 10. Emission filter -535–645 nm, 11. Data output -16-bit or 8-bit: SCN, TIFF, JPEG image files, 12. The Gel Placement door should be drawer type allowing access to Gels from either direction for facilitating easy/clutter free gel excision applications., 13. The Imaging System should offer a camera resolution greater than 6.3 megapixels & carry a pixel size of 2.4 μm x 2.4 μm , 14. The Instrument should offer Trans-UV (B) and Epi White as Standard Illumination. White Light Trans Illumination should be included, 15. Appropriate flat fielding correction should be automatically and consistently applied to image data for every application.
Specifications of the Image Analysis Software:
1. Automated lane and band identification, molecular weight or base pairs evaluation, band sizing, and quantitation based on a reference band or quantity standards, 2. Snapshot tool to copy images, lane profiles, and graphs, 3. Allow Publishing resolution (dpi) and publishing dimension to be specified with a one-click image export for publication. Provides functionality to produce image at user-defined dpi and dimension, 4. No requirement of license for registration. The full version software should be installable in large number of computers. Lifetime free upgrades of Software & Firmware should be available, 5. Mac and PC compatible software, 6. 16-bit and 8-bit tiff images with a one-click export option, 7. Software should produce customizable reports with data organized as desired, including, Lane and band identification, molecular weight or base pair evaluation. Band sizing and quantification are based on a reference band or quantity standards., 8. Software should offer live update of results with any change of analysis parameters., 9. Local/Global background subtraction for individual bands' 10. Tools for compliance with U.S. FDA 21 CFR Part 11 regulations.
Warranty: Three years , Suitable Computer i5 processor, 8GB / 512GB SSD/Windows 11 Pro/USB Keyboard & Mouse | 1 | No | 100 | ₹100 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 11.00 MB
BOQ_829405.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .