Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC Bid found in order | |
| 2 | L2₹19.7 L+₹29,925 (1.54%)Rejected-AOC NO 94 OLD NO 100 19TH MAIN ROAD 1ST N BLOCK RAJAJI NAGAR BANGALORE 560 010 | BANGALORE | BANGALORE | KARNATAKA | 560010 | L2 | Rejected-AOC Bid found in order |
Tender Value
Refer Docs
EMD Value
₹39,000
Closing Date
1 Jul 2021, 6:00 pmClosed
SHRI VINEET MODI
CWE AF North Bangalore Bellary Road JC Nagar Post Bangalore 560006
COMPREHENSIVE MAINTENANCE OF LIFTS AT HQTC BANGALORE
2021_MES_447042_1
87429CWEAFNBAN
Open Tender
Civil Works
Item Rate
330 days
GE (AF) BANGALORE
AS PER NIT
6 documents required · 6 mandatory
₹500
GE (AF) BANGALORE
₹39,000
Yes
14 Jul 2021
31 May 2021
3 Jul 2021
31 May 2021
1 Jul 2021
19 Jun 2021
2 Jun 2021 - 11 Jun 2021
Amount
Comprehensive maintenance of microprocesser controlled VVV frequency drive electric driven passenger lift of 884kg carrying 13 passenger with ARD facility from ground plus six floors consisting of examing, adjusting, lubricating, greasing the parts including replacement of following mentioned connected parts such as Relays, Rectifier and Indication display, Main Contactor transformer, Brake liner and Gear oil, Motor Oil and servicing, Gate lock switches Gate levers, Gate beaks, Gate track rollers, contact switches and limit switches, Floor level indication switch and oscillator switch, Car counter weight shoes and door and Gate Shoes, Pit switch and safety switches, landing floor indicator, car bush buttons and switches and Car indicators, Car top INS Panel board. Emergency Alarm Buttons, Up & down indicator cards, Aluminium Brackets,OSG roller and lubrication, Guide lubrication, auto door, Track rollers, and linking rolls, Door locks contact, Door lubrication and oil OSG rope, OSG clips and ,Main rope clips, Rope tension spring, OSG safety switch, RCR coil rewinding and RCR Coil, bolt & nuts, Buffer spring, all door track rollers,Surclips, Travelling cable, LOP & COP buttons with indicators, Door opening buzzer, stop button, door stopper, car & landing door, Door screen sensor, Door screen sensor cable, V3F drive, PC Board, mother board, door opening and closing belt, Door limit switches, Door frames, Main wheel pulley, main brake wheel fill and etc. Main Gear bearing, Main motor bearing, Door motor rewinding/replacement, Cabin car lights (LED), Ventilating fan rewinding and connected parts, cleaning of lifts , Rubber mat for lift of size as specified by the Engr-in-Charge to be replaced and if any connected items missing for satisfactory operation of lift will be assumed included as the rate quoted against item rate. The schedule item operated all as specified and as directed by Engr-in-Charge Make make Johnson bldg No P-317 at Map Accn Pkt-I
All as per item No 1 above but Make : Johnson bldg No P-318 MAP accn Pkt I
All as per item No 1 above but make Johnson bldg No P-319 Map accn Pkt II
All as per item No 1 above but make : Johnson bldg No P-320 Map accn Pkt II
All as per item No 1 above but make : KONE bldg No P-321 Map accn Pkt II
All as per Item No 1 above but make KONE bldg No P-322 Map accn pkt II
All as per item No 1 above but Make : KONE Bldg No P-323 Map Accn Pkt II
All as per item No 1 above but make : KONE Bldg No P-324 Map Accn Pkt II
All as per item No 1 above but make :KONE bldg No P-325 Map Accn Pkt II
Comprehensive maintenance of microprocesser controlled VVV frequency drive electric driven passenger lift of 554 kg carrying 8 passengers with ARD facility from ground plus five floors consisting of examing, adjusting, lubricating, greasing the parts including replacement of following mentioned connected parts such as Relays, Rectifier and Indication display, Main Contactor transformer, Brake liner and Gear oil, Motor Oil and servicing, Gate lock switches Gate levers, Gate beaks, Gate track rollers, contact switches and limit switches, Floor level indication switch and oscillator switch, Car counter weight shoes and door and Gate Shoes, Pit switch and safety switches, landing floor indicator, car bush buttons and switches and Car indicators, Car top INS Panel board. Emergency Alarm Buttons, Up & down indicator cards, Aluminium Brackets,OSG roller and lubrication, Guide lubrication, auto door, Track rollers, and linking rolls, Door locks contact, Door lubrication and oil OSG rope, OSG clips and ,Main rope clips, Rope tension spring, OSG safety switch, RCR coil rewinding and RCR Coil, bolt & nuts, Buffer spring, all door track rollers,Surclips, Travelling cable, LOP & COP buttons with indicators, Door opening buzzer, stop button, door stopper, V3F drive, car & landing door, Door screen sensor, Door screen sensor cable, PC Board, mother board, door opening and closing belt, Door limit switches, Door frames, Main wheel pulley, main brake wheel fill and etc. Main Gear bearing, Main motor bearing, Door motor rewinding/replacement, Cabin car lights (LED), Ventilating fan rewinding and connected parts, cleaning of lifts , Rubber mat for lift of size as specified by the Engr-in-Charge to be replaced and if any connected items missing for satisfactory operation of lift will be assumed included as the rate quoted against item rate. The schedule item operated all as specified and as directed by Engr-in-Charge Make make Johnson bldg No P-317 at Map Accn Pkt-I
All as per item No 10 above but Make : Johnson bldg No P-318 Map accn Pkt I
All as per item No 10 above but make : Johnson bldg No P-319 Map accn Pkt II
All as per item No 10 above but make : Johnson Bldg No P-320 Map accn Pkt II
All as per item no 10 above but Make Kone Bldg No P-321 Map accn Pkt II
All as per item No 10 above but make Kone bldg No -322 Map accn PKt II
All as per item No 10 above but make : Kone bldg No P-323 MAP accn Pkt II
All as per item No 10 above but make Kone bldg No P-324 MAP accn Pkt II
All as per item no 10 above but Make : Kone Bldg No P-325 Map accn Pkt II
All as per item No 10 above but operate in G+3, make Kone Bldg No 101 at HQ TC .
Note For item No 1 to 19:- 1. In addition to items mentioned in item No 1 to 19 comprehensive maintenance of lifts also consist of the following: - (a) At Machine Room :(i) checking of motor oil, Gear Oil, controller all loose connection, Brake sleepage while moving and stopping, main rope condition, Drive condition & resistance loose connection, main switch (ii) Cleaning of Motor Gear Brake and Speed Governer (iii) Greasing of Pedestal, OSG diverted pulley (b) At Hoistway (i) Checking of Gate Locks, Read Switches, Guide rail bolts, Limit switches, RCR, Magnets, Car top reed switch, Main rope clips, thimple rod bolts split pins, safety pin, pit pulley, Car gate switches, Car shoe & counter weight shoe, Final limit switches, All brackets Carsill, Car top, landing sill (ii) Lubrication in pit pulley, for satisfactory operation of lifts as specified and as directed by Engr-in-Charge. 2. Monthly inspection and servicing of lifts shall be done by the original lifts manufacter/ MES Enlisted contractor who is holding the lift maintenance licence from state govt of karnataka and service report duly signed by the authorised company rep shall be submitted every month during the contract period. 3. The item rate quoted againist 1 to 19 as comprehensive maintenance is deemed to inclusive of any spares except those mentioned in schedule items below form 20 to 47 for satisfactory operation of lifts as specified above. 4. Attending lift break down/ rectifying all defects of unserviceable lift : If any lift gets struck/block/unserviceable at site the lift mechanic should attend the complaint within two hours on receipt of complaint and the complaint should be resolved without any futher delay. Incase the problem could not be solved , the matter should be informed to the contractor as well as to the MES authority. Further if the contractor failed to the rectify the fault a recovery @ of Rs 200/- per hour wef the time of lodging the complaint till completion of 24hrs will be recovered from the Contractor dues. Also incase of any lift requires repair for want of spares the contractor should provide the spare parts in time or within 24hrs the Lift should be made serviceable failing which a sum @ of Rs 500/- per hour wef the time after 24hrs should be recovered from the Contractor dues. 5. The Contractor should keep all the spare parts intact for the above mentioned Lifts in the Lift Rooms. The rates should be quoted keeping in mind of the above mentioned expenses of the items from Item ser no 1 to 19 above)
6. A record of repairs carried out in each visit of each lift installation to be maintained separately duly signed by Contarctor, JE and Engineer-in-charge. The maintenance certificate duly signed by contractor and concerned JE E/M and Engineer-in-Charge seperately for each lift every month 7. The lift mechanic to collect the complaint register daily and on completion/rectification of complaint the register will be updated and signed. 8. The firm is responsible to purchace spare parts as required for day to day comprehensive maint shall be procured from Lift original manufacturers/auth distributor/dealer only and the GST vouchers to be submitted to Deptt while claiming payments.
Inspection of lift by govt lift inspector for worthiness certificate during the currency of contract agreement within due dates including load testing as per lift act and submitting the worthiness certificate all as directed and specified by EIC for the lift as per schedule for ser No 1 to 19. Note for item no. 20: Inspection of Lifts shall be carried out by Govt Lift Inspector including load testing as per Lift Act for worthness certificate during the currency of contract agreement within first 5 months or within One year from the last inspection.
M&L for taking out old burnt winding of stator and rotor, cleaning the slots and re-winding of motor 15 HP,3 Phase,415 volts with suitable gauge super enamelled copper winding wire and providing insulation materials such as fibre/ glass, 3 phase motor including necessary transportation to workshop if any and bring back, reassembling/refixing complete all as specified and as directed by Engineer-in-Charge.
All as per item no.21 above but motor 10 HP complete all as directed and specified.
M&L for rewinding of cabin fan in 13/8 passengers lift, single phase, 230 volts
Material and labour for spray painting of motor gear drive 10/15 Hp with synthetic enamel paint to match with exisisting colour including preparation of old painted surface complete all as directed and specified.
Supply & Fix maintenance free dry battery 18 AH, 12 volts for ARD system. Make: Exide /Amarton
S&F ARD battery charging card for 8/13 passenger lift all as specified and as directed. (Make: Toshiba / Jeltron)
S&F of ARD programme card suitable for 8/13 passenger lift all as specified and as directed. (Make: Toshiba / Jeltron)
M&L for opening the control panel door lock taking down old unserviceable and replacing with new serviceable all as directed by Eng-in-Charge.
S & F Auto Rescue Device (ARD) Suitable for 8 passenger lift complete including taking down old unserviceable all as directed. (Make: Toshiba / Jeltron)
Supply and fix switch disconnector 32 Amps side handle operated, open excution type, 230 Volts,50 Hz , AC, and including dismantling existing unserviceable complete all as directed and specified.(Make: Havells /indoasian / legrand)
Supply and fix MCB, SPN 40A , 230 Volts , 50 HZ,and including dismantling existing unserviceable complete all as directed and specified. (Make: Havells /indoasian / legrand)
Supply and fix MCB, TPN 40A , 415 Volts , 50 HZ,and including dismantling existing unserviceable complete all as directed and specified. (Make: Havells /indoasian / legrand)
Supply and fix RCCB 40 A, 4 Pole, 100 MA sensibility, P 20 protection, 50 HZ 415V AC all as specified and as directed. Make: Indoasian Cat Part No: 811725 or equivalent in L&T/ Schneider.
Supply and lay in repair flat lift cable 4x0.75 sqmm copper cable all as directed and specified alll as directed. (Make: Bhansal or equivallent.)
Supply and lay, in repairs, PVC lift floor mat of approved shade complete all as directed and specified by Eng-in-Charge.
Supply and fix in repairs anlog volt meter of size 90mmx90mm , ranging 0-500 volts complet all as directed. Make: Meco/AE
Supply and fix in repairs anlog ammeter of size 90mmx90mm, ranging 0-100A, complete all as directed. Make: Meco/AE
Supply and fix in repairs lift cabin landing floor door lock suitable for 8/13 passenger lift of make Kone/Johnson complete all as directed by EIC
Supply and fix in repair lift cabin fan grill, PVC suitable for existing fan complete all as directed
Material and labour for display board made of white coloured 6.0mm thick foam sheet with vinyl stickering of required colour to indicate symbols/letters as approved/directed by Engr-in-charge for displaying schematic diagrams/letter/directions/any other purpose etc complete including fixing/achoring on wall/wooden or MS doors etc all as specified and directed by Engr-in-charge. Note : The content/symbol of the display boards shall be approved by the Engr-in-charge prior to fabrication.
Suppy, fixing in repairs steel rope 13/10/8mm Usha Martin complete all as specified and directed by Engr-in-Charge
Supply and fix in repair of 10W LED bulkhead fitting complete all as specified and directed (Make: CG Cat No : LBHP-10-CDL or equivalent make in Havells/Philips)
Supply and fix in repair of 3W, cabin mounted LED cool day light fitting complete all as specified and directed (Make: Philips or equivalent )
M&L in replacement of broken glasses in lift cabin with new acrylic mirror along with nuts, bolts and washers duly drilling carefully in lift cabin without disturbing existing equipment, complete all as specified and as directed by engr-in-charge.
Supply and fix sub main wiring with Two single core FRLS PVC insulated cable with copper conductor multistranded 1100 volts grade 2.5 sqmm in and including non-metallic rigid PVC conduits and accessories and fixing arrangements fixed to surface on wall, floor or ceiling etc incl 1x2.5 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC conduit and two run of copper conductor together taken as one length for measuring unit length.
S&F in replacement of PVC conduit 20mm dia along with fixing acessaries in wall/ ceiling etc and inserting the power/ control cables all as specified and as directed.
S&F in replacement of PVC conduit 25mm dia along with fixing acessaries in wall/ ceiling etc and inserting the power/ control cables all as specified and as directed.
Man Elevators Company Pvt Ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .