Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 LAccepted-AOC 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹3.2 L+₹10,025 (3.27%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹3.2 L+₹16,075 (5.24%)Rejected-Finance 17 23 K P ROY LANE KOLKATA 700 031 | KOLKATA | KOLKATA | WEST BENGAL | 700031 | L3 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
EMD Value
₹6,157
Closing Date
7 Mar 2024, 12:00 pmClosed
AE/DESD
Old Secretariat Building Eric Banjamin Road, Darjeeling 734101
Supply and Installation of All Weather Split type Room Air Conditioner at The Richmond Hill, Darjeeling in the district of Darjeeling.
2024_WBPWD_675615_1
WBPWD/AE/DESD/e-NIQ- 17 of 2023-24
Open Tender
ELECTRICAL WORKS M/R
Item Rate
14 days
DARJEELING
Please refer Tender documents.
4 documents required · 4 mandatory
₹6,157
2 Jun 2025
28 Feb 2024
9 Mar 2024
28 Feb 2024
7 Mar 2024
28 Feb 2024
Amount
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC.
Supplying & fixing of 250V Wall Mounted Timer Panel fabricated from 3mm. thick M.S. sheet reinforced with 40mm x 40 mm x 6 mm angle iron frame with suitable ventilation, earthing attachment & locking arrangement. The Panel Board should be provided with following accessories etc on din bar complete as required. 2M RCCB 40A of sensitivity 100mA: 1No. 240V DP MCB 16A C Curve: 2Nos. 24 Hour programmable Analogue Time Switch with minimum switching time of 15 minutes: 2Nos. 2Pole Contractor 250V, 40A of AC3 rating: 2Nos.
Supply & delivery of Inverter Hot & cold wall mounted split air conditioner (2.0TR Capacity) fitted with hermetically sealed Compressor, Cooling capacity nominal 4500 Kcal/hr. Cooling Capacity minimum guaranteed 4275Kcal/hr. Minimum room discharge air flow 1120 Cub. m/h EER (w/w) cooling 3.23,Heating-3.61,Star rating-4, incl. all taxes. [OGENERAL-ASGG24LFCD-2 TON]
Installation of Split type Room Air Conditioner by fixing out-door unit on MS angle iron frame made of 40x40x6mm. angle & intermediate with 25x6 mm. flat grouted on wall/roof and in-door unit with suitable fixing arrangement including Protection for the outdoor unit by suitable size MS grill cover with key & looking arrangement incl. painting and allied accessories incl. making holes etc. and mending good the civil damages as per as practicable..
S&F refrigeration copper pipe (5/8" & 1/4") with insulation foam, Electric Cable (3 core 4 Sq.mm. PVC Copper Wire of approved make) as required.
S&F PVC pipe for drainage of water coming out from A.C. as per direction of E.I.C.
Supply & fixing of 2 module GI box consisting of North west(WIPRO make) 25/6A 6 pin plug socket incl. North west (WIPRO make) 25A 3pin plug top opaque on wall as direction by EIC ..
Supply & Fixing 240 V, Electron OLP 3+ Air Conditioner Starter With Digital Display (21 Amps_ For 1.5-2 Tons) and making necy. connections with PVC Cu wire and earth continuity wire etc.
ANAMICA ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .