Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹30.0 L+₹35,747.90 (1.21%)Rejected-Finance | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹30.0 L+₹44,435.90 (1.50%)Rejected-Finance | L3 | Rejected-Finance Higher bid value |
Tender Value
₹30 L
Closing Date
3 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 868 EWS
GE 868 EWS PIN- 913 868 C/o 99 APO
REPAIR AND CLEANING OF SEWAGE LINE, SEPTIC TANK, SOAK WELLS AND CONNECTED ITEMS IN SOUTH WEST ZONE AT RMS.
2021_MES_473641_4
8354/E8
Open Tender
Civil Works
Item Rate
180 days
RANGAPAHAR
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
GE 868 EWS
Exempted
26 Jan 2022
14 Dec 2021
5 Jan 2022
14 Dec 2021
3 Jan 2022
20 Dec 2021
60 days
Amount
Demolition and breaking up drain pipes(salt glazed,stoneware, AC or reinforced concrete) set in cement 'mortar 150 mm dia fixed in position
Demolition of cement concrete in ground floors and pavings n.exc 15 cm thick above or below ground level.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches etc complete
Demolition of reinforced cement concrete in ground floors and pavings n.exc 15 cm thick above or below ground level.(Reinorcement cut as required to facilitate demolition)
Taking down cement plaster and raking out joints, hacking for key,scrubbing down with water built in cement mortar.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed by Engineer-in-charge.
DWCPE (SN8) 180 (OD)/163(ID) mm diameter Pipes laid on 150 mm thick bed with excavation depth( 0.70m – 1.65 m) in any type of soil, including manholes/drop manhole of standard size made of Brick masonry/ RCC/Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functional.
Supply & fix in repair PVC (SWR) pipes single socketed in any length with rubber ring joints,but bore of pipe 150 mm dia laid in trenches or floors.
All as per item No 8 hereinbefore above but bore of pipe 110 mm dia .
All as per item No 8 hereinbefore above but bore of pipe 75 mm dia .
Supply & fix in repair PVC (SWR) pipes single socketed in any length with rubber ring joints,but bore of pipe 150 mm dia fixed to walls.
Supply and fixing as in replacement 100mm dia grating doom with waste hole of PTMT (minimum weight 25gms) complete all as specified and as directed by the Engr-in-Charge. Make: Prayag / Polytuf
Supply and fixing in repair 110/150 mm bore stack clamps out of 25mm by 3mm flat iron and round iron stays, including bolts and nuts and securing ends of stays to wall or roof for nominal bore.
S & F in repair PVC (SWR) bends any radius 110 mm dia
S & F in repair PVC (SWR) bends any radius 75 mm dia
S & F in repair 110mm dia PVC (SWR) branch piece, single (single Y equal or unequal) complete all as specified and directed.
All as per item No 16 herein before above but bore of pipe 75 mm dia.
S & F in repair 75mm dia, PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
S & F in repair PVC Gully trap 125/110mm, setting and jointing with solvent cement
Material and labour for brick work in cement mortar1:6 with sub class `B' bricks straight or curved on plan exceeding 6m mean radius.
M & L for rendering in 10 mm thick in cement mortar1:6 onfair faces of brick work, finished even and smooth without using extracement complete all asspecified.
M&L for cement concrete 1:2:4 type B1 using 20 mm graded stone aggregatre as in copings including necessary formwork.
Material and labour for deformed steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking endsand binding with mild steelwire (annealed) n.less than 0.9mm dia complete all as specified.
All as per item No 23 herein before above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
M & L for precast RCC 1:2:4 type B-1 using 20 mm graded aggregate as in manhole cover set in CM 1:4 including necessary form work complete.
M&L for plain cement cement concrete (1:5:10 type E-2) using 40mm graded stone aggregate as in foundation filling and mass concrete all as specified.
M&L for cement concrete 1:3:6 type C-2 using 20 mm graded stone aggregatre as in surface channels and drains including necessary form work complete.
M & L 75 mm thick PCC 1:3:6 type C2 (using 40 mm graded aggregate) as in plinth protection finished even and smooth without using extra cement.
Extra for forming fair finished surfaces of drain or channels, innergirth 30 cms, using extra cement including forms, moulds mitred/ stoppedends etc complete.
Cleaning of Blockage IWC,EWC, Wash basin, gully trap, floor trap etc either by hand pump or by rodding or by any other means untill clear flow is observed all as specified and as directed by Engr in charge.
Carrying out opening of manholes,sewer line of any type and any depth removing the sludge/solid content from the manhole/sewer line by manual/ mechanical method and also cleaning the sewage line of any dia and at any depth either by water pressure or by any other flushing or roding and other suitable means at the discretion of the contractor at his own arrangements so as to remove the blockage and making the sewer lines and manhole fully functional to the entire satisfaction of Engineer-in-Charge also to remove the sludge/solid contents out of defence land including covering with a layer of earth and repositioning of the RCC/CI cover slab all as directed by the Engineer-in-Charge in SW Zone under. The complaint shall be cleared/rectified to the complete satisfaction of Engineer-in-Charge .
Desilting of septic tank/soakage pit of any size, type and any depth and removing the sludge/solid content from the septic tank/soakage pit by manual/ mechanical method or any other suitable means at the discretion of the contractor at his own arrangements and make the septic tank/soakage pit fully functional to the entire satisfaction of Engineer-in-Charge also to remove the sludge/solid contents out of defence land including covering with a layer of earth and repositioning of the RCC/CI cover slab all as directed by the Engineer-in-Charge in Sw Zone.
Cutting into exisiting manholes for connecting new drains, making good topipes and rendering ,cutting out existing benching and forming branch channel, halfround or 3/4 section in cement concrete1:2:4 type B smooth finished and reforming benching as required, internal dia of pipe150mm
Excavating in trenches not exceeding 1.5m wide and n.exceeding 1.5m in depth; for foundation , etc not exceeding 10sq.m on plan and not exceeding 1.5m in depth and gettingout insoft/ loose soil all as specifed.
Excavation over areas, n.exc 1.5m deep,and getting out for foundation, etc. soft/loose soil.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm In soft/ loose soil.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point,in soils.
S&F in repairs vitreous china water closet (squatt pan) orrisa pattern 580x440 mm size pan white with front or back inlet with integral 'foot rests including provn of lime concrete bedding including connections to 'flushing cistern/pipe complete all as specified and directed including 100mm CI 'P' trap.
Supply and fixing as in replacement vitreous China wash down water closet pan (pedestal pattern) with ‘P’ or ‘S’ trap, front or back inlet, fixing bolts, with coloured PVC seat cover. Make: Parryware Cat No C0278 for water closet, Cat No C8071 EWC Standard for PVC seat cover or equivalent approved make.
M&L Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc.
M&L for Brushing neat cement slurry with 3.0 Kg of cement per Sq meter.
Material and labour for non skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm coloured in floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles over and including 15mm thick screed bed in CM (1:4) complete all as specified and as directed.
Material and labour for non skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm coloured in floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles over and including 15mm thick screed bed in CM (1:4) complete all as specified and as directed.
Material and labour for glazed ceramic coloured tiles of size 300x200x7mm thick as on vertical surfaces, set and jointed in neat cement slurry and pointed in white cement with pigment to match with the shade of tiles laid over and including 10mm thick cement plaster in CM (1:4) complete all as specified and as directed.
SK SINGH
m/s chakraborty enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .