Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 CrAccepted-AOC | ₹5.1 Cr | L1 | Accepted-AOC LOWEST QUOTED HENCE ADMITTE |
| 2 | L2₹5.7 Cr+₹54.6 L (10.6%)Rejected-AOC | ₹5.7 Cr+₹54.6 L (10.6%) | L2 | Rejected-AOC NOT LOWEST QUOTED HENCE NOT ADMITTED |
| 3 | L3₹5.7 Cr+₹57.6 L (11.2%)Rejected-AOC 20 1ST A CROSS SAI NAGAR AREHLLI UTTARHALLI BANGALORE 560 061 | BENGALURU URBAN | KARNATAKA | 560061 | ₹5.7 Cr+₹57.6 L (11.2%) | L3 | Rejected-AOC NOT LOWEST QUOTED HENCE NOT ADMITTED |
| 4 | L4₹6.9 Cr+₹1.7 Cr (33.6%)Rejected-AOC | ₹6.9 Cr+₹1.7 Cr (33.6%) | L4 | Rejected-AOC NOT LOWEST QUOTED HENCE NOT ADMITTED |
Tender Value
Refer Docs
EMD Value
₹6 L
Closing Date
25 Mar 2023, 11:00 amClosed
COL MANOJ NEGI
CWE AF North Bangalore Bellary Road JC Nagar Post Bangalore 560006
ADDITION/ ALTERATION TO HQTC BUILDING (P-101) UNDER GE (AF) BANGALORE
2022_MES_565933_2
87470CWEAFNBAN
Open Tender
Civil Works
Item Rate
365 days
GE (AF) BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹3,000
GE (AF) BANGALORE
₹6 L
Yes
10 Apr 2023
28 Feb 2023
27 Mar 2023
28 Feb 2023
25 Mar 2023
8 Mar 2023
1 Mar 2023 - 6 Mar 2023
Amount
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for all as specified and directed. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and directed. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at their cost in accordance with all applicable federal, state, and local regulations.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons incl granite slab in kitchen platform laid, bedded and pointed in any mortar etc all as specified and directed.
M&L cement concrete 1:2:4, type B1 (using 20mm graded stone aggregate) as in padding over floor/ roof all as specified and directed.
M&L for Vitrified tiles double charged/ ultracharged 8-10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.3 Sqm and not exceeding 0.36 Sqm in floors etc. set and jointed in neat epoxy cement slurry and pointed in white or coloured epoxy cement with 3mm to 4 mm thick spacer to match over and including 15mm thick screed bed of CM 1:6 all as specified and directed. Note: Rate shall include for spacer and epoxy etc.
All as per item No 05 but as in skirting over and including 10mm thick rendering on brick work or concrete surface wall as backing coat in cement mortar 1:4 all as specified and directed.
M&L for glazed ceramic coloured/ digital/ stone finish wall tiles in vertical surface 350x250x7mm/ 450x300x7mm/ 600x300x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering on brick work or concrete surfaced wall as backing coat of cement mortar 1:4 all as specified and directed.
M&L for non skid Ceramic tiles coloured 7 to 8mm thick (square/ rectangular) polished, area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm each, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed of CM 1:6 all as specified and as directed
M&L for 20mm thick Granite of any type work (table rubbed and polished) in cooking platform, window cill, step, wall lining and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade granite including 15mm Thick screed in CM 1:6 all as specified and directed.
Resecuring or easing & adjusting without taking down door/ window shutters of any description exc 1 sq. m and n exc 2 sqm all as specified and directed.
Taking down door/ window shutters of any description exc 1 sqm and n exc 2 sqm resecuring or easing and adjusting and refixing in same opening all as specified and directed. Note: Rate included for Butt hinges, Handle etc. new as required for re-fixing in same opening.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations.
Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dresses stonework and precast concrete articles.
M&L for pre-cast cement concrete block type C1 1:3:6 (20mm graded stone aggregate) masonry with solid blocks, exc. 10cm in width and setting in Cement mortar 1:4 complete all as specified and directed.
M&L for providing precast cement concrete solid building blocks type C1 1:3:6 (20mm graded stone aggregate) 10cm thick (with plain or interlocking joints as directed) setting in mortar 1:4 complete in walls all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. all as specified and directed.
M&L Stainless steel wire netting 0.90mm dia and 4-5mm lathing to wood, concrete or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste all as specified and directed
M&L for rendering 15mm thick cement plaster in cement mortar 1:6, on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement all as specified and directed.
M&L for 2 coats of distempering wall with oil emulsion distemper white or tinted over primer over a coat of 3mm thick wall care putty, including preparation of new surface all as specified and directed.
M&L for rendering 15mm thick cement plaster in cement morter 1:4 with water proofing compound, on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement all as specified and directed.. Note: Supply only water proofing compound shall be measured and paid seperately
Supply only Liquid integral water proofing compound
M&L for 2 coats of cement paint over a coat of primer on plastered and other surfaces of wall with alkali resistant priming paint including preparation of new surfaces all as specified and directed.
Rendering 5mm thick cement plaster in cement mortar 1:3, on concrete surfaces as in ceiling, finished even and smooth without using extra cement all as specified and directed.
M&L for 2 coats of distempering on ceiling with oil emulsion distemper white or tinted over a coat of 3mm thick wall care putty, including preparation of new surface all as specified and directed. Note : All Painting/ distempering will be done through mechanical means.
M&L for 2 coats of distempering wall with oil emulsion distemper white or tinted over a coat of 3mm thick wall care putty, including preparation of old surface after complete removal of existing treatment all as specified and directed. Note : All Painting/ distempering will be done through mechanical means.
M&L for preparation of old decorated surfaces as in ceiling including washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of oil emulsion distemper complete all as specified and directed. Note : All Painting/ distempering will be done through mechanical means.
M&L for preparation of old painted surfaces of any description not otherwise described wood and wood based surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. Note : All Painting/ distempering will be done through mechanical means.
M&L for french polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on old works with two or more coats complete all as specified and directed. Note : All Painting/ distempering will be done through mechanical means.
M&L for preparation of old painted surfaces of any description not otherwise described steel and iron surface over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work all as specified and directed.
M&L for form work to sides and soffits of floor or roof beam, beam haunchings, girders, bressumers, lintels, cantilevers, shelves, slab etc. including supports overhangs, etc finished rough in flat surface all as specified and directed.
M&L for reinforced cement concrete 1:2:4 type B1 (using 20mm graded aggregate) as in beams, cantilevers, slab, bressummers, lintels over 1.5m span etc all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutter from the frame ) wooden not exceeding 1.5 Sqm each all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutter from the frame ) wooden exceeding 1.5 Sqm not exceeding 4 Sqm each all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets all as specified and directed.
S&F false ceiling at any height 600mm x 600mm x 15mm Armstrong/ Everest mineral fiber Regular ceiling tiles of type classic lite RH- 99 laid on Armstrong/ Everest prelude XL exposed grid system with 9 mm wide T section flanges color white. The framework comprises of main runner spaced at 1200 mm centre, hanger (GI wire) to be fixed by approved roof plug and screws etc. the last hanger at the end of each main runner should not be greater than 450 mm from the adjacent wall. Flush fitting 1200 mm long cross tees (with double stitching) to be interlocked between main runner at 600mm center from 1200x600mm modules. Cut cross tees longer than 600mm to be supported independently 600mm x 600mm modules to be formed by fitting 600 mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Armstrong/ Everest wall angle secured to walls at 450 mm maximum centers all as specified and directed
S & F 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (Fillets, metal frame work and GI wire mesh paid separately) including cost of two or more coats to give an even shade of plastic paint on ceiling with putty work complete with designer ceiling (with part ply, laminate and cove) all as specified and directed.
Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre all as specified and directed.
S&F Hangers 6 mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed.
S&F Prelaminated medium density fibre particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work all as specified and directed.
S&F Intermat auto closing concealed hinge, Kutchina/Hettich/Hafele make complete all as specified and directed.
S&F 6" premium quality crome finish handle, Kutchina/Hettich/Hafele make complete all as specified and directed.
S&F good quality Telescopic channel for drawer multi-tech high capacity 500 mm long , Kutchina/Hettich/Hafele Make complete all as specified and directed.
S&F 19-20mm wide and 0.80mm thick decorative type PVC beading complete all as specified and directed.
Dismantling structural/ mild/ wrought steel work including doors, gates, grill, grating but excluding framed truss etc. all as specified and directed
S&F framed work such as grills, gratings etc.. with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290 Gde-E-165 all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or including butt welded tubes conforming to IS 1161-1998 grade St-240 all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall or in door, fixed with self tapping screws all as specified and directed.
S&F in repairs second class hardwood as in plain fillets square, rectangular or triangular in section exc 13 & n.exc 25 sqcm, clean sawn, secured with screws or brads all as specified and directed.
S&F in repairs second class harwood teak finish beading/ hand rail decorative antique finish in section exc 13 & n.exc 25 sqcm, clean sawn, secured with screws including french polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats all as specified and directed.
S&F in repairs 4mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers only one face has decorative veneer fixed with nails over 12mm thick plywood, grade BWR, type BB, fixed with screws to timber frame work including French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats all as specified and directed.
S&F second class hard wood plain, solid, straight chowkats and frames wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints all as specified and directed.
M&L 35mm thick flush shutters solid core construction with block board core and plywood face panels, commercial type on both sides all as specified and directed.
M & L 35mm thick plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated all as specified and directed.
S&F 35mm thick 2nd class hard wood glazed and skeleton shutter as in door open rebated and prepared to receive glass, gauge etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers edges of framing plain chamferred or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR part-I, Sec-08, Clause 8.24 (a), kiln seasoned and chemically pressure treated complete all as specified and directed.
M&L for preparation of untreated new wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed.
S&F in repair magic eye ball ultra-clear view with wide angle for all round visibility with ultra clear Lens, superior and antique brass finish with 180 degree great visibility to install over a wide range of door thickness up to 40mm complete all as specified and directed.
S&F in repairs 140mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring all as specified and directed,
S & F in repair mortice latch with two levers (vertical type), brass body and length of the latch is 65 mm complete all as directed
S&F in repairs curtain rod brackets fancy type brackets with rounded fancy type end knobs, with antique finish or coloured suitable for holding 25mm dia single curtain rods fixed to wall with necessary polished wooden piece 20mm thick exc 50 sqcm in section complete all as specified and directed.
S&F in repairs 25 mm dia mild steel powder coated, fancy type curtain rod complete all as specified and directed.
S&F powder coated anodised aluminium grill for bird proofing, frame for doors, windows, ventilators and fixed partition etc with one or more rebates including jointing cleat for fixing etc. complete all as specified and directed.
S&F powder coated anodised aluminium , window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.
S&F sheet glass, of 4.80 mm thick ordinary quality and glazing with oil putty in square exc.0.5 Sqm in each pane all as specified and directed.
S&F sheet glass, of 4.80 mm thick ordinary quality and glazing with oil putty in square n. exc. 0.5 Sqm in each pane all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples all as specified and directed.
S&F in repair rough cast, wired figured glass, 6.4 mm thick and glazing with oil putty in square n. exc. 0.5 Sqm in each pane all as specified and directed.
Demolition mud/ mud phuska in roofs, any thickness, including plastering, tiling and leeping (whether full thickness removed or only a part thereof)
Taking down old damaged existing water proofing membrane of any thickness from roof top complete all as specified and directed.
M&L for cutting holes in circular section for inserting 160 mm dia rain water PVC pipe on vertical stone masonry wall of 400 to 600mm thickness by mechanical means all as specified and directed.
S&F PVC (SWR) pipes 160 mm bore, single socketed, in any length with rubber ring joints, fixed to wall all as specified and directed.
S&F 160mm bore PVC (SWR) bends of any radius all as specified and directed.
S&F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required on vertical stone masonry wall: hooks (stay), heavy for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 all as specified and directed.
S&F mild steel screw bolts, diameter of neck in 16 to 20 mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 10cm and n exc 15cm long all as specified and directed.
M&L for water proofing treatment on horizontal or vertical surfaces by applying oil bound bitumen primer at 0.20 Kg/Sqm and providing 4 mm thick APP modified water proofing membrane weighing not less than 4 Kg/Sqm reinforced with non-woven polyester matt weighing not less than 160 gm/Sqm including minimum 10 cm side lap and 15 cm end lap torch sealed and bonded and applying a coat of blown grade hot bitumen 90/15 over and below the membrane @ 1.20 Kg/Sqm over RCC roof slab/ projection/ parapet after cleaning the surfaces by removing dust, dirt etc as manufacturer's instructions complete all as specified and directed.
S&F in repairs 15 mm two in one bib taps with flange, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixedall as specified and directed of Make: Jaquar Cat No-FON-40041/ORP10041PM or equivalent.
S&F in repairs premium quality 15 mm bib tap with wall flange chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified and directed of make- Jaquar Cat No-FON-40081/OPP5037PM or equivalent.
S&F in repair soap dish all as specified and directed of Make-Jaquar Cat No- CAN-1137/AKP-35731P or equivalent.
S&F in repair Toilet paper roll holder with flap all as specified and directed of Make-Jaquar Code No- AKP-35753P or equivalent.
S & F in repairs single lever basin mixture with popup waste system with 450 mm long braided hose all as specified and directed of Make: Jaquar-LYR-38051B/ORP-10011BPM or equivalent.
S&F in repairs table top basin of size 170x835x455 mm/ 565X425 X140mm of white colour complete all as specified and directed of make-Jaquar Cat No-KUS-WHT 35935/ JDS-WHT-0547 or equivalent.
S&F in repairs 15mm bore hand shower (Health Faucet) with 8 mm dia, 1 metre long flexible tube and wall hook all as specified and directed of make: Jaquar Cat No- ALD -573/ALD 577 or equivalent.
S&F in repair towel rail of 600 mm long all as specified and directed of Make-Jaquar Cat no-AHS-1507 or equivalent.
S&F in repair urinal with electronic sensor, wall hung, back inlet, built in waste outlet with water seal of size 400mmx 330mmx 630mm complete all as specified and directed of Make-Somani(FIGARO) or equivalent.
S&F in repair 8 mm thick curved shape urinal partition with frosted glass chrome finish of size-900mmx450mm all as specified and directed of Make-Jaquar or equivalent.
S&F in repair glass shelf of 600 mm long with CP bracket all as specified and directed of make-Jaquar Cat no-CAN-1171N or equivalent.
S&F rimless single piece WC with UF slim seat cover, hinges fixing accessories and accessories Set, Cistern fitting, size 380mmx670mm x765mm with hydraulic sheet cover and connecting to 'S' trap 300 mm including taking down old WC complete all as specified and directed of Make Jaquar FSS-WHT-29853S300UFSM/ OPS-WHT-0205 or equivalent.
S&F in repairs CP connection 15mm dia and 450mm long with two Nos of brass checknuts and washers complete all as specified and directed of Make Jaquar cat no-ALD-805B or equivalent.
S&F CP gratings size 125 mm dia complete all as specified and directed.
S&F Towel rack without lower hanger of 600 mm long and 03 Nos hook all as specified and directed of Make-Jaquar Code No- AHS-1581 or equivalent.
S&F Towel ring square with round flange all as specified and directed of Make-Jaquar Code No-ACN-CHR-7721 or equivalent.
S&F in repair angle stop cock with wall flange 15 mm dia chromium plated, screwed down, high pressure, screwed both ends for 15mm bore iron pipes or for unions, all as specified and directed of Make-Jaquar Cat no-CON 059KN or equivalent.
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm complete all as specified and directed.
S&F kitchen utensil rack in steel made of premium grade stainless steel highly durable and rust-proof of size not less than 90cmx80cm x20cm complete all as specified and directed.
S&F soap Dispenser with metalic bottle all as specified and as directed of Make-Jaquar Code No- ACN-1137 N or equivalent.
Taking up or down 15mm bore water tubing and connection or cleaning for refixing all as specified and directed.
Taking up or down 20 mm bore water tubing and connection building , or cleaning for refixing all as specified and as directed by Engineer In Charge.
Taking up or down 25 mm bore water tubing and connection building , or cleaning for refixing all as specified and as directed by Engineer In Charge.
M&L for Cutting chases in stone masonry walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth etc complete all as specified and directed.
S&F UPVC 15 mm dia pipe pressure rating 10 Kgf/cm2 with all fittings and fixed to wall /laid in floor complete all as specified and directed.
S&F UPVC 20 mm dia pipe pressure rating 10 Kgf/cm2 with all fittings and fixed to wall /laid in floor complete all as specified and directed.
S&F UPVC 25 mm dia pipe pressure rating 10 Kgf/cm2 with all fittings and fixed to wall /laid in floor complete all as specified and directed.
S& F 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or fixed with floor including necessary fixing cleats/ clamps complete all as specified and directed.
S& F 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall including necessary fixing cleats/ clamps, complete all as specified and directed.
S&F in repairs 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed with wall including necessary fixing cleats/ clamps complete all as specified and directed.
S&F in repairs PVC bend of 110 mm dia complete all as specified and directed.
S&F in repairs PVC bend of 75 mm dia complete all as specified and directed.
PVC (SWR) branch piece of 110 mm dia single (single Y) equal or unequal complete all as specified and directed.
S&F in repair 100 mm bore cast iron soil, waste and vent pipe in any length with or without ears with cement joints laid in trenches or in floor or wall including necessary fixing cleats/ clamps complete all as specified and directed.
S&F in repairs 100 mm bore cast iron soil, waste, branch piece, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel all as specified and directed.
S&F in repairs 100mm bore cast iron soil waste bend of any radius all as specified and directed.
Dismantling water tank, capacity in litres exc 500 & n exc 1000 and removing to store all as specified and directed.
S&F rotational moulded polyethylene water storage tank, of capacity 1000 litres (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I .
S&F ball valve 25 mm dia, high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe and fixed all as specified and directed. (Minimum weight 15 mm-142 gms/ 20 mm - 210 gms/ 25mm-455 gms/ 40 mm - 690 gms).
Disconnecting existing tanks of capacity exc 500 & n.exc 1000 litres, setting aside (or lowering if required) for repairs, cleaning etc. and hoisting if required reconnecting and re-fixing in position including cleaning and removing all scale and dirt etc, from tanks and from mouths of circulating pipes etc all as specified and directed.
Disconnecting existing tanks of capacity exc 250 & n.exc 500 litres setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc all as specified and directed.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe 25mm dia and fixed all as specified and directed.
Removing old dumped junk/ building materials/ debris/ tree roots, trunk, & branches of any size etc. to a distance of 30 Km or beyond, out of premises of metropolitan area, including loading, unloading manually or by mechanical means (JCB) and to be transported through tractor-trolley or tipper and disposal at the destination.
M&L colored chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry with white cement & pigments in floors over 20mm thick screed bed of cement mortar 1:6 all as specified and directed.
Excavation in trenches not exc 1.5m wide and not exc 1.50 m in depth for foundation etc and getting out in hard/ dense soil complete all as specified and directed.
Excavation in trenches exc 1.5m depth and not exc 3.0m in depth for foundation etc and getting out in hard/ dense soil complete all as specified and directed.
M&L PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) in foundation, fillings and mass concrete complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in hard/dense soil all as specified and directed.
Removing excavated material (soil) not exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed.
M&L RCC cover slab type B-1,1:2:4 (using 20 mm graded aggregate) supported on walls, beams and columns, in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like as in man hole cover etc. all as specified and directed.
M&L 2 coats of cement based paint over a coat of priming plastered and other surfaces of wall with alkali resistant priming paint including preparation of new/existing untreated surface wall all as specified and directed.
M&L TMT Bar 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L TMT Bar 6mm dia and over, in stirrups cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F 300 mm dia reinforced concrete pipes, class NP3, laid and jointed complete with collars including necessary fixing cleats/ clamps, complete all as specified and directed.
M & L concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 type C-2 for 300 mm dia pipe complete all as specified and directed. Note: Rate incl for necessary formwork, shuttering and support to concrete for laying bed.
Cutting into existing manholes for connecting new drains 300 mm bore, making good to pipe and rendering cutting out existing banching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar and internal dia of pipe 150 mm complete all as specified and directed.
M&L for 160mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints drain pipe laid in trenches and jointed as specified complete and directed.
M&L concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 type C-2 for 160 mm dia pipe, complete all as specified and directed.
M&L PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in surface channel for man holes and the like including weathering slightly rounded or chamfered angle and throating complete all as specified and directed.
M&L PCC 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in coping and benching and the like including weathering slightly rounded or chamfered angle and throating including formwork complete all as specified and directed.
Dismantling old pressed precast concrete interlocking paver block of any shape and size and refixing the same with grey cement and pigment and including 40mm thick sand cushion all as specified and directed complete.
M&L PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in surface channel and drain for man holes and the like including weathering slightly rounded or chamfered angle and throating complete all as specified and directed.
M&L hard core, broken stone/ boulders of gauge n exc 63 mm complete all as specified and directed.
M&L for pre-polished coloured Machine pressed precast concrete interlocking paver block rubber moulded with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade and including 40mm thick sand cushion all as specified and directed including dismantling the existing paver block.
Removing aluminium partition/ work station or any discription incl fixed type table and refixing the same including necessary drilling and bolting in same place after tilling work complete all as specified and directed.
M&L for 75mm thick Cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in flooring, foot path, hard standing, plinth protection, bases of water tanks etc. all as specified and directed.
Supply and fixing at site TRAY PANEL SCREW type system with aluminium composite panel of approved plain colour or wood grain printed on interior walls, columns, MS structure, ceiling, coping, slab projectons, cable covering, cable duet etc at all heights and elevation over aluminium framework. The aluminium composite panel should be 4 mm thick consisting of 3mm thick thermoplastic core of anti toxidant LDPE sandwiched between 2 skins of 0.5mm thick aluminium alloy sheet making a total panel thickness of 4mm. The external surface shall be finshed with PVDF based coating on the top side and service coating on the reverse side shall be with a polymer paint complete all as specified and directed. NOTE:- The system shall be fitted over aluminium. sub frames, cleats and shall be fixed to the masonry/ RC walls/ MS structure with necessary clamps, galvanized M.S brackets and anchor fasteners. All clamps and brackets shall be Hot dip galvanized minimum 80 microns thick and shall conform to IS: 4759-1996. Any other acessories such as fastening straps, nuts, bolts, rivets, washers, etc. other than anchor system shall be in Indian standard grade. all joints of ACP must be sealed with approved sealent of approved colour. sealant make DOW CORNING 789 weather sealant. Rate shall include to provide open cell polyethylene backer rods, weather sealant etc, all materials and labour complete. (Aluminium section shall be measured and paid separately)
S&F anodised aluminium frame for partition/ fixed type windows, ventilators, wall panelling work with one or more rebates including jointing cleat for fixing, rubber/ snap beading etc. complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including fittings & fixtures such as switches, ceiling rose, pendants, regulators, sockets, ceiling roses, pendants, regulators, light fittings etc. removing materials to store for keeping in safe custody for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Taking down wall mounted fan from walls and refixing the same including connecting up and provision of cable from ceiling rose or connector to fan all as specified and directed.
Taking down ceiling fan from ceiling, dismantling blades & refixing of the same including provision of suitable size of fan down rod as per site requirement for lowering of ceiling fan below the false ceiling height as per the site requirement and connecting up including provision of cable from ceiling rose or connector to fan all as specified and directed.
Taking down Exhaust fan, from walls and refixing the same including connecting up and provision of cable from ceiling rose or connector to fan all as specified and directed.
Point wiring with cable of PVC insulated FRLS copper multistranded conductor 1.5 sqmm 1100 volts grade in and including heavy grade PVC Conduit Pipe ISI marked broken white or of cream colour with all accessories and fixing arrangements on Stone walls / brick masonary walls /ceilings /floors etc. including fixing top cover/ PVC/ MS Modular type junction boxes fixing on stone walls / brick masonry walls surface for housing switches/sockets/regulators etc. with and including 1.5 sqmm PVC insulated multistranded copper earth continuity conductor connecting to the common earth dolly etc complete all as specified and directed for One light controlled by one single pole 5 Amps switch.
All as per item No 155 but one ceiling fan point controlled by one single pole 5 Amps switch.
All as per item No 155 but one Exhaust fan point controlled by one single pole 5 Amps switch.
All as per item No 155 but one wall fan point controlled by one single pole 5 Amps switch.
All as per item No 155 but one 3 pin switch socket out let point 5 Amps on independent board
All as per item No 155 but one 3 pin switch socket out let point 5 Amps on same board with other switches.
All as per item No 155 but two light controlled by one single pole 5 Amps switch.
All as per item No 155 but four light controlled by one single pole 5 Amps switch.
All as per item No 155 but six light point controlled by one single pole 5 Amps switch
All as per item No 155 but one bell Point controlled by one push button 5 Amps switch on independent board
All as per item No 155 but one light controlled by two, way 5 Amps switches.
Point wiring with cable of PVC insulated FRLS copper multistranded conductor 2.5 sqmm 1100 volts grade in and including heavy grade PVC conduit Pipe ISI marked broken white or of cream colour with all accessories and fixing arrangements on stone walls / brick masonry walls/ ceilings / floors surface on wall including top cover/ PVC/ MS modular type junction boxes fixing on stone walls/ brick masonary walls gang box fixing on wall surface for housing switches/ sockets/ regulators etc. with and including 2.5 sqmm PVC insulated multistranded copper earth continuity conductor connecting to the common earth dolly etc for one 15A switch socket combination on independent board all as specified and directed.
Point wiring with cable of PVC insulated FRLS copper multistranded conductor 4.00 sqmm 1100 volts grade in and including heavy grade PVC conduit pipe ISI marked broken white or of cream colour with all accessories and fixing arrangements on stone walls / brick masonry walls/ ceilings/ floors surface on wall including top cover/ PVC/ MS modular type junction boxes fixing on stone walls/ brick masonry walls gang box fixing on wall surface for housing switches/ sockets/ regulators etc. with and including 4.00 sqmm PVC insulated multistranded copper earth continuity conductor connecting to the common earth dolly etc for one 15A switch socket combination on independent board all as specified and directed.
S&F Modular switch, 1 Module single pole one way 10 Amps.
S&F Modular switch, 1 Module single pole one way 16 Amps.
S&F modular socket , 2 Module 6 Amps, 2/3 pin, 240 volts Ac 2/3 pin combined all as specified and directed at site.
S&F modular socket , 2 Module 6/16 Amps, 2/3 pin, 240 volts AC 2/3 pin combined all as specified and directed.
S&F of modular type fan regulator upto 120 watts with 5 step speed control for fans any sweep 1200 mm/1400 mm.
S&F of modular type Bell push 6 A, 1 Module.
S&F of Ding Dong Bell, AC, 230 volts, Single Pole.
S&F Modular switch, 1 Module single pole two way 10 Amps.
S&F of modular white cover plate with frame, 1 module.
S&F of modular white cover plate with frame, 2 module.
S&F of modular white cover plate with frame, 3 module.
S&F of modular white cover plate with frame, 4 module.
S&F of modular white cover plate with frame, 6 module.
S&F of modular white cover plate with frame, 8 module.
S&F of metal flush box 1/2 module.
S&F of metal flush box 3 module.
S&F of metal flush box 4 module.
S&F of metal flush box 6 module.
S&F of metal flush box 8 module.
S&F PVC ceiling rose 65 x 50 mm surface type with 3 terminals all as specified and directed.
S&F rigid PVC trunking white colour of 195mm x 50mm along with bodies & with flexible cover 185 mm as per OEM, LEGRAND fixing on stone walls/ brick masonry walls/ ceilings/ floors etc. for running of all type of service/ miscellaneous cables complete with fitting such as joints/ Tee/ elbow/ coupler etc, including taking down old PVC cable trunking all as specified and directed. Make : LEGRAND, CAT NO.: 010452 ( BODY) and 010526 ( COVER ) or equivalent make.
S&F PVC divider suitable for 195 X50mm trunking including taking down old PVC cable Trunking all as specified and directed. Make : LEGRAND, CAT NO. : 075609 or Equivalent make.
S&F suitable End cap of size 195X50mm trunking including taking down old PVC cable Trunking all as specified and directed. Make : LEGRAND or Equivalent make.
S&F cover joint suitable for 195X50mm trunking including taking down old PVC cable Trunking all as specified and as directed. Make : LEGRAND or Equivalent make.
S&F body joint suitable for 195 X50mm trunking including taking down old PVC cable Trunking all as specified and directed. Make : LEGRAND or Equivalent make.
S&F of Flat angle suitable for 195 X50mm trunking including taking down old PVC cable Trunking all as specified and directed. Make : LEGRAND, or Equivalent makes
S&F RJ 11 telephone sockets (jack type) with shutter, 1 module all as specified and directed. Make: Legrand Cat No. 679331 or equivalent in GEWISS/ INDOASIAN/ L&T.
S&F TV/ Audio Video/ RJ 45 Computer socket, 1 module all as specified and directed. Make: Legrand Cat No. 679332 or equivalent in GEWISS/ INDOASIAN / L & T
S&F LED Light fitting 2 feet, 10 Watts, 220 volts, AC decorative box type with driver, holder including LED tube light connecting up with 2 core flexible copper conductor cable of suitable size from ceiling rose all as specified and directed.
S&F LED Light fitting, 20 Watts, 220 volts, AC decorative box type with driver, holder including LED tube light connecting up with 2 core flexible copper conductor cable of suitable size from ceiling rose all as specified and directed.
S&F LED luminaires surface type 600 x 600 mm, 36 watts, 220 V, AC Surface type with high efficency PMMA diffuser soft glare free light complete with driver. Make : CG, MODEL NO AURA-I, CCR-127-36-57-SL-NWH or equivalent in HAVELLS/ PHILIPS/ BAJAJ/ WIPRO/ POLYCAB
S&F office LED Luminaires type 36 watts, LED 600 x 600 mm grid ceiling including connecting up with PVC sheathed 1.5 sqmm 2 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed. Make : CG, VECTOR -VII, Cat : LCTLRF7 or equivalent make in HAVELLS /WIPRO / POLYCAB /BAJAJ / PHILIPS
S&F round shaped LED 15 watts, 220 V, AC recessed type with high efficency PMMA difuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose all as specified and directed.
S&F Track light systems LED type 220 V, with 3 nos light in one track recessed type with high efficency, complete with driver, holders & LED lamp suitable for roof ceiling/ wall mounting including connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose all as specified and directed.
S&F LED light fitting 9/ 10 Watts bulk head Luminaires including LED light driver holder connecting up with 2 core flexible copper conductor cable of suitable size from ceiling rose all as specified and directed.
Taking down completely existing fire alarm system and refixing the same after completion of wiring work all as specified and directed.
Cutting into or through the stone walls /brick walls built in cement mortar or cement lime mortar and walls of cement concrete suitable size for housing for sunk box using heavy duty stone drilling/cutter machine and making good the disturbed surface all as specified and directed.
Cutting chases, pinning in stone walls/ brick walls etc. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings etc, for concealed conduit wiring into or through the stone walls built in cement mortar or cement lime mortar and walls of cement concrete suitable for housing 25 mm dia conduit pipe using heavy duty stone drilling/cutter machine and making good the disturbed surface all as specified and directed.
S&F Exhaust fan AC single phase 230/ 240 V of size 380 mm sweep, 900 RPM, with louvre including taking down old existing exhaust fan all as specified and directed. Make : BAJAJ, Model no : SUPREME PLUS, CAT NO : 70067 or equivalent in HAVELLS /WIPRO / POLYCAB /CG / PHILIPS
S&F Wall Mounted fan AC single phase 230/ 240 V of size 450 mm sweep including taking down old existing wall mounted fan all as specified and directed. Make : BAJAJ, Model no SUPREME MK II, CAT NO : 250439 or equivalent in HAVELLS /WIPRO/ POLYCAB /CG / PHILIPS
S&F ceiling fan AC single phase 230/ 240 V of size 1200 mm sweep including taking down old existing ceiling fan all as specified and directed. Make : CG, Model no : EXCEL STAR, CAT NO 251083 or equivalent in HAVELLS / WIPRO/ POLYCAB/ BAJAJ/ PHILIPS
S&F sub main wiring with two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 2.5 sqmm in and including non-metallic rigid PVC conduit and accessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including 2.5 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor, one run of PVC conduit and two run of copper conductor shall be one length for measuring unit length.
S&F sub main wiring with two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 4.0 sqmm in and including non-metallic rigid PVC conduit and accessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including 4.00 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor, one run of PVC conduit and two run of copper conductor shall be one length for measuring unit length.
Supply and fix sub main wiring with two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 6 sqmm in and including non-metallic rigid PVC conduit and accessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including 6.00 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor, one run of PVC conduit and two run of copper conductor shall be one length for measuring unit length.
S&F sub main wiring with two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 10 sqmm in and including non-metallic rigid PVC conduit and accessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including 10.00 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC Conduit and two run of copper conductor shall be one length for measuring unit length.
S&F sub main wiring with four single core PVC insulated cable with copper conductor multistranded 1100 volts grade 10 sqmm in and including non-metallic rigid PVC casing and capping and accessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including 2 X 10 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : Two run of earth continuity conductor, one run of PVC conduit and four run of copper conductor shall be one length for measuring unit length.
Taking down carefully existing split Acs and installing, commissioning and testing at new locatioin including core cutting in stone/ brick wall/ any surface etc complete all as specified and directed. Note :- The quoted rate shall be deemed to be included for necessary wiring, copper tube and top up of Gas for the ACs as required.
M&L earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanised iron strip 25 x 4 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
M&L for earth continuity conductor or main earthing lead of size 25 x 4 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed for earthing etc. all as specified and directed.
Taking down cerefully fire alarm control panel with BS EN 54 2 loop panel of capacity of 99 dector and 99 modules and refixing the same including testing & commissioning.
S&F Addressable type multisensor detector with heat and smoke combination including taking down old existing detector all as specified and directed.
Taking down Addressable type multisensor detector with heat and smoke combination and refixing the same with extension of detectors upto false ceiling height including provision of PVC Cable wiring & flexible hose pipes all as specified and directed.
S&F 1.5 sqmm 2 core copper cable for fire detectors communication with PVC conduit duly fixed on stone walls/ Brick walls with connected fittings and accessories complete all as specified and directed.
S&F of sheet metal enclosure for DB's double door TPN 04 ways when MCBs to be used single pole and neutral, deep drawn with 200 Amps rated copper bus bar 415 V including taking down old unserviceable from existing place complete all as specified and directed.
S&F of sheet metal enclosure for DB's double door TPN 8 ways when MCBs to be used single pole and neutral, deep drawn with 200 Amps rated copper bus bar 415 V, including taking down old unserviceable from existing place complete all as specified and directed.
S&F Sheet metal enclosure for DB's double door SPN, 12 ways when MCBs to be used single pole and neutral,deep drawn with 200 Amps rated copper bus bar 240V, including taking down old unserviceable from existing place complete all as specified and directed.
S&F Sheet metal enclosure for DB's double door SPN, 8 ways when MCBs to be used single pole and neutral,deep drawn with 200 Amps rated copper bus bar 240V, including taking down old unserviceable from existing place complete all as specified and directed.
S&F MCB TPN, 63 Amps, 415 V, C- series with breaking capacity of 10KA complete all as specified and directed.
S&F MCB SPN, 40 Amps, 240/415 V, B- series with breaking capacity of 10KA complete all as specified and directed.
S&F MCB SP, 6-40 Amps, 240V, B- series with breaking capacity of 10KA complete all as specified and directed.
Taking down existing VTPN MCB DB double door, repair and refixing of the same all as specified and directed.
Taking down existing TPN MCB DB repair and refixing the same all as directed and specified.
Taking down existing SPN MCB DB enclosure & repair and refixing the same all as specified and directed.
S&F Control Switch unit 25 Amps suitable controlling of AC unit all as specified and directed. Make : INDOASIAN, CAT NO 800194 or equivalent make
Taking down Light sensor completely and refixing the same with extension upto false ceiling including provision of PVC cable wiring & flexible hose pipes all as specified and directed.
S&F Light Sensitive Switch movement detectors for lighting control, IP20 -IP 55 with detection angle of 180 to 360 degree, Dual ceiling switch sensor of 8.5A including taking down old unserviceable from existing place complete all as specified and directed.
S&F rigid PVC trunking white colour of 80 mm x 50mm with a long bodies & with flexible cover 65mm as per OEM, LEGRAND fixing on stone walls/ brick masonry walls/ceilings / floors etc. for running of all type of service/ miscellaneous cables complete with fitting such as joints/ Tee/ elbow / coupler etc, including taking down old PVC cable Trunking all as specified and directed. Make : LEGRAND, CAT NO. : 010452,( BODY) 010521 (COVER ) or Equivalent make
S&F PVC conduit pipe for fire wiring of size 20 mm dia all as specified and directed.
S&F PVC Conduit pipe for fire wiring of size 25 mm dia all as specified and directed.
S&F suitable size of PVC pipe along with suitable size of PVC Copper cable wiring for extension of existing fire detectors fixed on existing roof ceiling and to be lowered below the false ceiling height & refixing the same all as specified and directed.
Taking down completely existing of PVC casing/ capping (for AFNET Cable) of size 32 mm dia and refixing the same after completion of wiring work all as specified and directed.
S&F PVC casing/ capping (for AFNET Cable) of size 40 mm dia inclusive of all accessories and fixing arrangements fixed to surface on wall. Make:- CONA
Supply, install, test, synchronise and commissioning of Roof top solar power plant of capacity 25 KWP, On-grid type complete with following components :- (I) Solar PV Modules with corrosion resistant aluminium frame, inter connecting cables, diodes etc - Qty as required to generate. Note : Following information should be found mentioned on each module :- a. Name of the manufacture of the PV module b. Name of the manufacture of Solar Cells. c. Month & year of the manufacture (separate for solar cells and modules) d. Country of origin (separately for solar cells and module) e. I-V curve for the module Wattage, Im, Vm and FF for the module f. Unique Serial No and Model No of the module g. Date and year of obtaining IEC PV module qualification certificate. h. Name of the test lab issuing IEC certificate. (II) Module Mounting structure (i) It shall be made of Hot dip galvanised MS or aluminium. (ii) Suitable fastening arrangement, grouting and coping to be provided to secure modules against wind. (III) Array Junction Box (AJB) : (i) AJB's shall be made of GRP/FRP with dust, water & vermin proof arrangement with IP 65 protection with transperant covers. (ii) It shall have SPD and Reverse blocking iodes.
(IV) Solar on grid Inverter with MPPT charge controller : (i) It shall be enclosed in weatherproof enclosure with minimum IP 65 protection (ii) It shall have features like wake up, synchronisation, shut down etc (iii) It should have Anti-Islanding protection and also Internal protection arrangement against various electrical faults (iv) Nominal Output power 3 Phase, 415V, AC, 50 Hz (v) THD shall be less than 3% (v) PF more than 0.9 (V) AC Distribution Box (ACDB) : (i) It shall be made of GRP/FRP with dust, water & vermin proof arrangement with IP 65 protection with transperant covers. (ii) It shall have SPDs, control gears etc. (VI) Cabling, wiring and conduiting (i) Interconnections to be provided all as per OEM recommendations complete for AC and DC supply from Solar PV modules to Existing State Grid panel which is existed at site. (ii) All wires / cables must be terminated through cable lugs. (iii) The input & output termination can be made through suitable cable glands. (VII) Independent Lightning Protection System comprising Aluminium Air Termination Rod 12mm dia 300mm length Qty-04 Nos, Aluminium strip 20x3mm from Air Termination rod to Test Point - Upto 20 Rm, Test point-01 No, GI Earthing pit with Earth Resistance Value less than 5 Ohms - 01 No
S & F 12mm thick toughened glass double leaf door (02 leaf per door) with polished/ etching as per approved pattern without frame including cutting/ polishing edges in suitable size fixing for opening in vertical position or for partition etc, complete all as specified and directed. (i) Stainless steel D type handle - 02 Nos/ leaf (ii) Stainless steel Floors base plate - 01 Nos/ leaf (iii) Cleats/ Clams, Hinges etc, as required.
S & F cobble stone 60 to 75 mm thick as approved colour and shape complete incl joint filling with colour cement & pigment all as specified and directed by Engr-in-Charge including demolition of existing surfaces in any thickness as required at site.
S & F in repair PVC floor trap of 100mm dia complete all as directed.
S & F in repair PVC door 'T' 110mm dia complete all as directed.
S & F in repair PVC door 'T' 75mm dia complete all as directed.
Taking down Chowkhat or frame with shutter (with or without taking off shutter from the frame) wooden window/ ventilator of any type/ description area exc 1.5 Sqm each and not exc 4 Sqm and refixing after reducing the width/ length as required in site incl necessary fittings required complete incl two coat or more coats of French polishing after preparation of old surface complete all as directed. Note :- Glass and wire mesh measured and paid separately.
Sai Ram Builders
K. VENKATESH NAIDU
M/s M Munivenkatappa and Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .