Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | ₹1.4 Cr Quoted ₹1.5 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹1.5 Cr+₹7.0 L (4.81%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹1.5 Cr+₹7.0 L (4.81%) | L2 | Rejected-Finance Other than being lowest |
| 3 | L3₹1.5 Cr+₹8.7 L (5.96%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹1.5 Cr+₹8.7 L (5.96%) | L3 | Rejected-Finance Other than being lowest |
| 4 | L4₹1.6 Cr+₹13.0 L (8.91%)Rejected-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | ₹1.6 Cr+₹13.0 L (8.91%) | L4 | Rejected-Finance Other than being lowest |
| 5 | Rejected-Technical 1446 ELITE ENTERPRISES NORTH SOLAPUR NEAR SUSHIL MARATHI SCHOOL SOLAPUR MAHARASHTRA 413004 | SOLAPUR | MAHARASHTRA | 413004 | - | - | Rejected-Technical Three Class below |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
22 Jul 2022, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIRE RELACEMENT OF HT LT PANEL BOARD HT LT CABLES REPAIR TO CAPACITIRS AND OVER HAULING CALIBRATION FILTRATION OF HT AND LT EQUIPMENT AND REPAIR AND MAINTANCE OF DG SET IN MD ACCN OUTLAYING AREAS AND MANNING AND OPERTAION OF AND ROUTING MAINTENANE
2022_MES_530367_1
8723/CWE (NW) Mumbai/ E8
Open Tender
Civil Works
Item Rate
330 days
GE (NW) NOFRA
Class B
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) NOFRA
₹2.2 L
Yes
16 Sept 2022
11 Jun 2022
25 Jul 2022
11 Jun 2022
22 Jul 2022
15 Jul 2022
11 Jun 2022 - 13 Jul 2022
Amount
Testing of dielectric strength of transformer oil of indoor type transformer, 11KV/433 volt, filteration of transformer oil by passing through filtration plant to remove moisture, impurities and improving di-electic strength to above 40 KV for 1 minute including new transformer oil for toping up & testing after filtration complete as specified. (Note: Transformer oil will be measured & paid seperately.)
M& L for Removing old burnt Transformer oil and Supply and toping of transformer oil with 50KV di-electric strength complete all as specified.
M&L for Dismantling of Damaged Breather and Supply and fixing in repair of breather with 500 Grams celica gel of indoor type transformer 300KVA/400/500 KVA, all as specified and directed by Engineer-in-Charge.
M&L for Dismantling of Damaged thermometer and Supply and fixing in repair of thermometer(oil temperature gauge) for indoor type transformer, all as specified and directed by Engineer -in -Charge.
Material and labour for Spray Painting of Transformer of following capacity,indoor type with Two coats of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities complete and all as specified and directed by Engineer-in-charge.
Transformer 500KVA ,11KV/433Volt
Transformer 400KVA ,11KV/433Volt
Transformer 300KVA/200KVA ,11KV/433Volt.
Material and labour for Servicing/Repairing of Transformer by disconnecting of LT and HT cable carefully from Transformer and draining out transformer oil, dismantling transformer top cover and dismantling of 4Nos LT bushing and 3Nos of HT bushing including necessary tools and plant for removal of sediments,carbon deposits at bottom of transformer tank, on core,on winding etc cleaning with new transformer oil including cleaning of oil tank and attending leakage problem with oil seal and all gaskets and re assembling complete all as specified and directed. (Note : New Transformer oil and spare parts will be measured and paid separatley excluding oil seal)
Transformer 500KVA ,11KV/433Volt
Transformer 400KVA ,11KV/433Volt
Transformer 300KVA/250KVA ,11KV/433Volt
Material and labour for replacing Burnt out Studs and bushing with nuts of any material by providing new copper alloy stud with nut,washers and bushing on HT Side complete all as specified and directed for following capacity transformers:-
Transformer 500KVA ,11KV/433Volt
Transformer 400KVA ,11KV/433Volt
Transformer 300KVA/250KVA ,11KV/433Volt
Material and labour for replacing Burnt out Studs and Bushing with nuts of any material by providing new copper alloy stud with nut,washers and bushing on LT Side complete all as specified and directed for following capacity transformers:-
Transformer 500KVA ,11KV/433Volt
Transformer 400KVA ,11KV/433Volt
Transformer 300KVA/250KVA ,11KV/433Volt
Dismantling of old damaged Cooling Fins and supply and fix in repair cooling fins of transformer of capacity 400/500 KVA as per manufacturer's specifications and standard practice complete all as specified and directed.
Material and labour for loading into truck of faulty Transformer of capacity 250 KVA to 500 KVA with the help of Crain and shifting from site to factory premises and unloading complete all as specified and directed.
Material and labour for loading into truck of Transformer capacity 250KVA to 500KVA after carying out the repair with the help of Crain and shifting from factory premises to site and unloading and shifting it inside the sub station and connecting all HT and LT cable connections and earthing connections complete all as specified and directed.
Material and labour for Dismantling the Core and taking out along with windings and cleaning oil tank of transformer 250 to 500KVA, 11KV/415Volts and removing sludges from tank, manufacturers specifications and standard practice complete all as specified and directed. (Note: Transformer Oil will be measured and paid seperately).
Material and Labour for Dismantling the faulty HV winding carefully from transformer of any type and capacity11KV/433Volts from core and rewinding the HV winding with suitable size of insulated copper wire as per manufacturers specifications and standard practice complete all as specified and directed.
Material and Labour for Dismantling the faulty LV winding carefully from transformer of any type and capacity,11KV/433Volts from core and re winding the LV winding with suitable size of insulated copper wire and as per manufacturers specifications and standard practice complete all as specified and directed.
Material and labour for reinsulating the HV winding with DPC insulation and as per manufacturers specifications and standard practice complete all as specified and directed.
Material and labour for reinsulating the LV winding with DPC insulation and as per manufacturers specifications and standard practice complete all as specified and directed.
Material and labour for refixing the core and windings assembly with insulating material and hardware of Transformer of any capacity and type,11KV/433Volts in to the oil tank with suitable fixing arrangements and re connecting HV and LV internal connections to HV and LV bushings and replacing gaskets of bushings,bottom and top valve, top cover, conservator and replacing celica gel breather and fixing top cover with conservators and reassembling all parts respect to original position and refilling of new transformer oil and filler to achieve the BDV Values and testing as per manufacturers specifications and standard practice complete all as specified and directed. (Note: transformer oil will be measured & paid seperately)
Disconnecting and dismantling the existing indoor type, 11 KV horizontal draw out type OCB trolly of rupturing capacity 250 MVA, 400 Amps from location and repair /overhauling and carrying out with the following activities as mentioned below complete all as specified and directed by Engineer-in-Charge. (Note: spare parts and new transformer oil shall be measured & paid seperatly) .
(i) Inspecting/overhauling of spring drive mechanism by checking mechanism, hold on catch assembly,trip bridge, z srew, Cam U, Aluminum trip bridge, Main trip lever assembly and apply multi grease lubricant to function smoothly. (ii) Inspecting / overhauling of OLTLF assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system. (iii) Inspecting / overhauling / cleaning and inspecting insulators, moving contacts ,fixed contacts,arcing chamber by carbon cleaner solution and apply dry graphite conductive sealant for contacts to avoid carbon deposits on contact surfaces. (iv) Inspecting/Cleaning of oil tank inside and out side surface by CRC throughly and replacement of transformer oil (60 litre for each OCB) and apply heavy duty grease for tank raising/lowering guide. (v) Assembling all items/components parts to the respective position & testing the breaker with High Voltage and Meggering before and after high voltage test complete.
Material and labour for painting of HT OCB capacity 250/350MVA,11KV, 400Amps, with one coat of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities for out side surface and in side surface of OCB all as per specified and as directed by Engineer-in-charge.
Disconnecting and dismantling the existing indoor type, 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350 MVA, 400/630/800 Amps from location and repair /overhauling and carrying out with the following activities as mentioned below complete all as specified and directed by Engineer-in-Charge. (Note: spare parts will be measured & paid seperately.)
(i) Inspecting / overhauling of manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly swich assembly and apply multi grease lubricant to function smoothly. (ii) Inspecting / overhauling of tripping assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system. (iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interuptors by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces. (iv) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC) and meggering before and after high voltage test complete.
Material and labour for painting of HT VCB capacity 250/350MVA,11KV, 400/630/800Amps, with one coat of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities for out side surface and in side surface of OCB and all as specified and as directed by Engineer-in-charge.
Material and labour of Opening the bus -bar chamber,CT chamber, PT Chamber and Meter chamber of HT 11KV, panel board and carry out following activities as mentioned below complete all as directed and specified by Engineer-in-Charge. (Note: spare parts shall be measured & paid seperately.) :-
M&L for Testing /Overhauling and secondary injection of over current earth fault relays/release on each multiple setting readjustment by artificial load complete all as specified including testing complete.
Dismantling, overhauling and testing Potential transformer capacity 11 KV / 110 volts AC and replacement of worn out spares such as contacts, bushing, control wiring fibre plates, gaskets , transformer oil and applying multi grease to the mechenical parts & dry graphite conductive sealant to contacts etc & re-assembling the same and commissioning complete all as specified and directed by Engineer-in-Charge. (Note : Spare parts and oil will be measured and paid seperately)
Material & Labour for repairs/ Overhauling/Servicing to Existing LT electric panels Indoor type of each Transformer by taking shut down from appropiate authority including following activities (i) Tightning the loose connections and cleaning inside/out side complete replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors ,providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting (silver colour) / powder coating and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge complete all as specified and directed . (Note : MCCB,ACB, measured and paid separately under relevant items of this schedule.)
(i) Cleaning inside the panel and all incoming and out going feeders i.e incling MCCB/SFU/Changeover switches/Contactors/ ACB,s thoroughly with help of Vaccum Cleaner. (ii) Checking the loose connections of incoming and out going feeders and rectifify the same with help of new GI nut bolts and washers. (iii) Replaceing the burnt out coluor coated PVC Sleeve of main and fedders bus with appropriated size of New PVC heat shrinkable sleeves -01Job. (iv) Replacing Burnt out Voltmeters/Ammeters/Indicating Lamps/Hrc Fuses.(Note: New items will be measured and paid separatly)-01Job. (v) Replacing burnt out contrle wiring of Ammeter/Voltmeter/Indicating lamps and CT'switch 2.5/1.5Sqmm copper sinhel core,1100V grade copper conductor cable- 01Job. (vi) Replacing Burnt out Bus Bar of incomming and out going feededs with approprieted size new bus bar (Copper/Aluminum) -01Job( Note : Bus Bar will measured and paid separately) (vii) Replacing Burnt out Insulators of incomming and out going feededs with approprieted size new Insulators -01Job( Note : Insulators will measured and paid separately)
Material & Labour for repairs/ Overhauling/Servicing to Existing LT electric FBB Out door type of each Transformer by taking shut down from appropiate authority including following activities (i) Tightning the loose connections and cleaning inside/out side complete replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors ,providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting (silver colour) / powder coating and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge complete all as specified and directed . (Note: The tenders quoted rate per unit shall deemed to be inclusive of taking out burnt ACB/ MCB/MCCB/Voltmeter /Ampermeter/CT/LED lamps of any type and discription etc and refixing the same,which shall be measured and paid as supply only under relevant items of this schedule.)
(i) Cleaning inside the panel and all incoming and out going feeders i.e incling MCCB/SFU/Changeover switches/Contactors/ ACB,s thoroughly with help of Vaccum Cleaner. (ii) Checking the loose connections of incoming and out going feeders and rectifify the same with help of new GI nut bolts and washers (iii) Replaceing the burnt out coluor coated PVC Sleeve of main and fedders bus with appropriated size of New PVC heat shrinkable sleeves -01Job (iv) Replacing Burnt out Voltmeters/Ammeters/Indicating Lamps/Hrc Fuses.(Note: New items will be measured and paid separatly)-01Job (v) Replacing burnt out contrle wiring of Ammeter/Voltmeter/Indicating lamps and CT'switch 2.5/1.5Sqmm copper sinhel core,1100V grade copper conductor cable- 01Job (vi) Replacing Burnt out Bus Bar of incomming and out going feededs with approprieted size new bus bar (Copper/Aluminum) -01Job( Note : Bus Bar will measured and paid separately) (vii) Replacing Burnt out Insulators of incomming and out going feededs with approprieted size new Insulators -01Job( Note : Insulators will measured and paid separately) (viii) Re welding of Doors with new Injus
Supply & fixing Aluminium Bus Bar strips, of any size, for extention of MCCB terminals for cable terminations, inside the cable alley of LT panel board, duly supported on the FRP / DMC support insulators including necessary drilling / bending to obtain required shape and size complete all as specified and as directed . Note :- (a) Size of the strip shall be determined depending upon the current carrying capacity of the individual outgoing MCCBs. (b) Overall length of the strip shall be measured and paid after necessary conversion into weight. (c) Cost of drilling / bending / Grinding of the strips at site as required shall be included in the unit rate quoted. No extra payment shall be admissible on that account. (d) Bolts, Nuts etc shall be measured and paid separately under respective items.
Supply & fixing Copper Bus Bar strip, of any size, for extention of MCCB terminals for cable terminations, inside the cable alleoy of LT panel board, duly supported on the FRP / DMC support insulators including necessary drilling / bending to obtain required shape and size complete all as specified and as directed . Note :- (a) Size of the strip shall be determined depending upon the current carrying capacity of the individual outgoing MCCBs. (b) Overall length of the strip shall be measured and paid after necessary conversion into weight. (c) Cost of drilling / bending / Grinding of the strips at site as required shall be included in the unit rate quoted. No extra payment shall be admissible on that account. (d) Bolts, Nuts etc shall be measured and paid separately under respective items.
Supply and fixing of suitable type and size FRP / DMC bus bar support insulator (Bridge Insulator) for fixing the extended aluminium bars, for cable terminations, duly fixed in the body of the panel board by and including galvanized steel bolts , nuts, washers etc.and necessary drillings, in the panel body,complete all as specified and as directed.
Material and labour for repairing of Capacitor (APFC ) panel of 100KVAR to 250KVAR and carryout repairs as (i)Dismantling of Power contactor,TP,415Volts and auxiulary contactors and cleaning,Overhauling,servicing ,repairing thoroughly and replacing burnt contactors upto 63Amps including suitable capacity of copper wire single core,1100Volts grade -01 Job (New contactors will be measured & paid separatly)
Supply & fixing power pack ,230V AC input, 30V DC /110Volt DC out put suitable for VCB/OCB 11 KV as power back complete all as specified and as directed.
Dismantling of Old Damaged/burnt spare parts from VCB and Supply and fixing in repair of following Spare parts suitable for - VCB 11 KV , 630 amps indoor type complete all as specified and directed by Engineer-in-Charge.
Opening / Closing Push Button Assembly
Motor Charding mechanism gear box
Limit Switches
Closing Coil Assembly
Tripping Coil assembly
Spring Charging Motor
Auxiliary Switch with link
Spring return latch
Vaccum Interupter assembly
Spout Insulator assembly feeder side
Spout Insulator assembly Bus bar side
Potential Transformer,11KV/110Volt/Rout3,100VA burden Trolly mounted with HRC Fuse
Current Transformers,50-30,5+5Amps, Class1 and 5p10,15VA,18.3kA/3Sec
TNC Switch
Indicating Lamps24/110V DC LED type
Dismantling of old burnt Spout insulator and Supply and fixing of spout insulator assembly for HT OCB 11 KV , 400 amps indoor type with current carrying parts complete all as specified and directed by Engineer-in-Charge.
Dismantling of old burnt through insulator and Supply and fixing in repair of OCB through insulator assembly with current carrying parts for OCB, 11KV, 400Amps, indoor type and complete all as specified and directed.
Supply and lay electrical LT insulation rubber matting as per ISI of size 1m x 2m x 19 mm thick complete all as specified and directed.
Cutting and removing grass, vegetation bushes etc from surrounding all installation roof and removing all rubbish to a distance not exceeding 50 m as complete all as specified and directed.
Dismantling of old burnt gasket and Supply and fixing in repair of OCB oil tank gasket 3mm thick suitable for OCB, 11KV, 400Amps, indoor type complete all as specified and directed.
Dismantling old burnt Heaters and Supply & fix in repairs strip type heater 80watt with control wiring suitable for indoor OCB/VCB,11 KV switch gear Panel board complete all as specified and directed by Engr-in-Charge.
Dismantling Air Circuit Breaker 4pole/3pole, 630Amps to 1200Amps, 415 Volts, draw out/fixed type from location and repair /overhauling of spring drive mechanism, coil, auxiliary switch including setting of over load coil, no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspecting male and female contacts and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective position and testing complete all as specified and directed by Engineer-in-Charge.(Note : Spare parts will be measured and paid separately)
Dismantling of old damaged Lamps and Supply & fixing in repairs indicating lamp holder with bulb LED(Red Yellow,Blue,Green) type to indicate incoming supply suitable for 24 V DC/110 VAC/230Volts AC and all as specified and directed.
Dismantling of old damaged/burnt ACB with Bus Bar and Supply , fixing ,testing and commissionning in repair in existing panel ACB. 4Pole, 1000 Amps ,MDO ,50KA suitable for 415V, 3phase, AC supply including necessary modification in panel with 2mm thick CRCA sheet door and suitable size of Copper bus bar and all specified and directed.
Dismantlin the old damaged Relay and Supply only APFC Relay, 12Stages digital type suitable for 415V, 3phase, AC supply and all specified and directed.
Dismantling the Old damaged Caoacitor Bank and Supply only Capacitor bank 5KVAR, Heavy duty type,415Volts,50Hz AC supply in existing panel complete as specified and directed by Engr-in-charge.
Ditto all as per item No.46 but of rating 10KVAR
Ditto all as per item No.46 but of rating 15KVAR
Ditto all as per item No.46 but of rating 20KVAR
Ditto all as per item No.46 but of rating 25KVAR
Dismantling of Old Damaged Contactor and Supply only Power contactors Capacitor Duty(Type MOC of L&T) 50Amps Capacitor duty with 2NO+2NC suitable for ,415Volts,50Hz AC supply in existing panel complete all as specified and directed by Engr-in-charge
Ditto all as per item No.47 but rating 40Amps
Ditto all as per item No.47 but rating 32Amps
Dismantling of old damaged MCB and Supply and fixing in repair of MCB,TP,C'Curve,63 Amps,415Volts,50Hz AC supply in existing panel with mounting rail complete all as specified and directed by Engr-in-charge.
Ditto all as per item No.50 but rating 40Amps
Ditto all as per item No.50 but rating 32Amps
Ditto all as per item No.50 but rating 20Amps
Dismantling of Old Damaged Contactor and Supply only Auxilaury contactors 10Amps Capacitor duty with 8NO+8NC suitable for ,415Volts,50Hz AC supply in existing panel complete all as specified and directed by Engr-in-charge
Dismantling of Old Damaged timer and Supply only Time delay Timer suitable for APFC panel ,415Volts,50Hz AC supply in existing panel complete all as specified and directed by Engr-in-charge
Dismantling of Old Damaged CT and Supply only Current Transformers,415V 600/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel and all as specified and directed.
Dismantling of Old Damaged CT and Supply only Current Transformers,415V 400/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel and all as specified and directed.
Dismantling of Old Damaged CT and Supply only Current Transformers,415V 200/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel and all as specified and directed.
Material and labour for fault finding on HT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge.
Material labour for HT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT for 11KV gradecomplete with Jointing material (Heat shrinkable)and accessories suitable for 3 core XLPE armoured, aluminium conductor cable of size 120 to 185 sq mm and all as directed by Engineer-In-Charge.
Material labour for HT Cable Jointing work by Cutting the faulty cable and making END TERMINATION JOINT for 11KV grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3 core XLPE armoured, aluminium conductor cable of size 90 to 185 sq mm and all as directed by Engineer-In-Charge.
Supply and laying HT cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)11000 Volts grade with stranded aluminium conductor of size 185Sqmm 3 core and all as directed by Engineer-In-Charge.
Material and labour for fault finding on LT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge.
Material labour for LT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT for 1100V grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 16 to 25 sq mm and all as directed by Engineer-In-Charge.
Material labour for LT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT for 1100V grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, aluminium conductor cable of size 35 to 50 sq mm and all as directed by Engineer-In-Charge.
Material labour for LT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT for 1100V grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, aluminium conductor cable of size 70 to 185 sq mm and all as directed by Engineer-In-Charge.
Material labour for LT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT for 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, aluminium conductor cable of size 240 to 300 sq mm and all as directed by Engineer-In-Charge.
M&L for Cutting and removing of old faulty cable piece and Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 240Sqmm 3.5 core and all as directed by Engineer-In-Charge.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 150Sqmm 3.5 core and all as directed by Engineer-In-Charge.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 120Sqmm 3.5 core and all as directed by Engineer-In-Charge.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 95Sqmm 3.5 core and all as directed by Engineer-In-Charge.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 70Sqmm 3.5 core and all as directed by Engineer-In-Charge.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 50Sqmm 3.5 core and all as directed by Engineer-In-Charge.
Material & labour for chequered plate 5 mm thick size as per site requirement including cutting to required shape and appling two coat of synthetic enamel paint over a coat of red oxide primer and all as directed
Material and labour for fixing angle Iron of size 25x25x6mm size and square bar applying two coats of synthetic enamel paint over a coat of red oxide primer and all as directed
Material and Labour for Attending Faults/Trippings and rectifying /repairing the faults in LT Panels Boards/Capacitor Panels Boards/ MCCB's/ACB's /Change Over switches/Cable Connections/Bus Bar etc including PVC insulating Tapes/Nut bolts and all as specified and directed by Engineer-In-Charge. Note : Damaged/Burnt MCCB/ACB'S/Changeover switc/Lugs.will be measured and paid separately)
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,630 Amps,35kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,400 Amps,35kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,315 Amps,35kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,250 Amps,25kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,160 Amps,25kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,100 Amps,16kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,63 Amps,16kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt Change Over Switch and Supply & fixing of Change Over Switch ,4Pole, 400 Amps, Open Execution,ON LOAD type 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt Change Over Switch and Supply & fixing of Change Over Switch ,4Pole, 250 Amps, Open Execution,ON LOAD type 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 300Sqmm to 240Sqmm complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 185Sqmm to 150Sqmm -240Sqmm complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 120Sqmm to 95Sqm complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 70Sqmm to 50Sqmm complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 35Sqmm to 16Sqmm complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 10Sqmm to 4Sqmm complete all as specified and directed by Engr-in-charge.
Material and Labour for Attending Faults/Trippings and rectifying /repairing the faults in HT Panels Boards/Cable Connections including HT insulating Tapes/Nut bolts and all as specified and directed by Engineer-In-Charge. Note : Spare Parts.will be measured and paid separately)
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth in hard/dense soil for laying of cable/ GI pipe and getting out complete all as specified and directed.
Returning, filling in including spreading levelling watering well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing surplus soil to a distance outside MoD land and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply and fixing HDPE of pressure rating 6kg/cm sq pipe of 110 mm dia including necessary bends, elbows, Tees etc on cable protection complete all as specified and directed by Engineer-in-Charge.
Supply and fixing HDPE of pressure rating 6kg/cm sq pipe of 90 mm dia including necessary bends, elbows, Tees etc 90 mm dia including necessary bends, elbows, Tees etc on cable protection complete all as specified and directed by Engineer-in-Charge.
Supply and fixing HDPE of pressure rating 6kg/ cm sq pipe of 63 mm dia including necessary bends, elbows, Tees etc on cable protecion complete all as specified and directed by Engineer-in-Charge.
Cutting metal road/hard standing for laying of cable and re metaling/making good the same to match the existing surface complete all as directed by Engr incharge.
Servicing of diesel engine of 125 KVA at INS Shikrs Power house,repair/replacement of the following components including opening engine and replacing all gaskets complete all as specified and directed by Engr-in -charge
(a) Cylinder head gasket to be repaired
(b) Element LO filter with O ring 1 set.
(c) Element fuel filter with O ring -1set
(d) Filter screen - 2 set
(e) Element air cleaner 1 No
(f) Element Bypass filter with O ring 1 No.
(g) All fuel,oil,and coolent and head need to be changed.
(h) Checking water temperature safety control
(j) Checking and correcting up impeller of water pump for excess play.
(k) Checking and correcting turbocharger oil leakage, tightening of mounting screws and nuts
(l) Cleaning, tightening all electrical connection of engine
(m) Checking generator brushes (Alternator) and commutator and replacing the brushes.
(n) Cleaning of entire engine.
(o) Checking exhaust and inlet manifold bolts and cap screw
(p) Checking engine blow by.
(q) Cleaning of radiator inside and outside by removing and refixing after cleaning.
(r) Checking and adjusting injector and valves.
(s) Cleaning fuel inlet connections and screw,
(t) Changing of governor oil.
(u) Replacing of radiator hoses of different sizes with clamps
(v) Checking of vibration damper.
Removing the old engine oil from the diesel engine sump of various DG sets, cleaning the oil sump thoroughly, supply and fill new engine oil of make Servo super 20W40 of Indian oil or equivalent grade of Hindustan Petroleum as directed by Engineer -in -Charge.
Repair/overhauling of self starter including replacement of worn out clutch assembly,bush,spring,plunger assembly, solenoid switch, carbon brushes, brush spring etc. for the following DG Set.
Supply and replace PVC insulated battery lead of suitable size with copper conductor cable of length 1.5 mtr with copper/brass clamps and lugs for fixing on battery terminals and self starter complete as specified and as directed.
Cleaning of the fuel tank of the following capacity DG sets after decaning the diesel, painting with one coat of approved colour synthetic enamel paint after thorough cleaning and preparation of surfaces, marking of fuel level gauge, fuel tank cap, writing of tank capacity
Supply and fixing 12 Volt 180 AH battery with 24 plates , liquid immersed and fully charged
Checking the serviceability of any capacity DG set per month and rectified the minor repair as directed by Engr-In-Charge
PART-I Manning and Operation of R.O Plant in three shifts round the clock 0600 hrs to 1400 hrs, 1400 hrs to 2200 hrs and 2200 hrs to 0600 Hrs including sunday and holiday with cleaning and up keep of the installation operating the submersible pump installed in raw water bore well -02 Nos and operation of treated water pump set including taking care from any pilferage, theft or damage of RO plant etc complete all as specified and directed by Engineer-in-Charge. Notes :- (i) RO operator : 01 No per shift (ii) RO Plants- 02 Nos. (iii) Quoted rate shall be deemed to be for the both RO Plant and shall have out put water capacity not less than 40,000 liters per day. (iv) The Quality of out put water shall confirm to IS 10500 of 1991.
PART-II Routine maintenance of RO plants No. 1 & 2 installed at Vandana and Vishakha complex having out put capacity of drinking water not less than 40,000 ltrs / day, maintenance of chlorine dosing system,coagulant dosing system,antiscalant dosing system carrying out the routine maintenance recommended by the manufacturer for daily, weekly, monthly and quarterly including repairs/ replacement of parts such as bearings, repairs of pumps, filters, welding of cracked/ broken any mild steel items/ foundation, PVC pipes and their fittings, LT panel boards etc complete including painting to all equipment with synthetic enamelled paint complete and all as specified & directed by Engineer-in-Charge including testing of treated water in the approved laboratory for bacteriological test and potability test for every month. Notes :- (a) Chemicals required for operation of RO plant will be measured and paid seperately under Schedule 'A' Part - III (b) RO Plant shall be maintained for smooth functioning and for out put capacity of drinking water not less than 40,000 liters / per day.
Note for item no. 108 (i) contarctor shall submit ID proof,police verfication,Bank A/C deatils ,Educational certificate to departmnet and obtain approval from Engineer-in-charge before employing person as a AC plant opeartor . (ii) Payment should be done by crossed cheque through aadhar linked bank account only and it shall not be less than minium fair ewages as per act in vogue.The contractor should submit proof of payment before claming payment. (iii)An minimum qualification for RO plant operator not to be les than ITI or equivalent certified courses from state/Central govt recognized institute. (iv) Contarctor has to submit proof of payment of group insurance subscription made by him as applicable as per latest laws/acts before claming RAR. (v) Contarctor should provide two set of uniform ,shoes to each employed person.
PART-III Material and labour for overhauling and including replacement of minor spare parts of submersible pump of installed at Vandana and Vishakha complex complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out unserviceable multiple valve and supply fix with new multiple valve of RO plant complete to match the existing and connecting up with existing system including all accessories complete all as specified and directed by Engineer-in-Charge. Make :- DEWS Aircon / Flow Max / Initiative or as approved by GE.
Disconnecting and taking out unserviceable cartridge filter and supply fix with new cartridge filter of RO plant complete to match the existing and connecting up with exisiting system including all accessories complete all as specified and directed by Engineer-in-Charge
Disconnecting and taking out unserviceable carbon filter and supply fix with new Carbon filter of RO plant complete to match the existing and connecting up with exisiting system including all accessories complete all as specified and directed by Engineer-in-Charge
Taking out old unserviceable membranes and supply & fix new Reverse Osmosis membrane all as specified and directed by Engineer-in-Charge. Make: Hydranautic/GE/ DOW/CSM or as approved by GE.
Disconnecting and taking out unserviceable Bore well submersible pump 3.0 HP and supply fix with new Bore well submersible pump horizontal type 3.0 HP capacity,Three phase,2880 rpm,50hz,head-80.5 meter, discharge-1.11 lps complete to match the existing and connecting up with existing control / electric system including all accessories complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out unserviceable open well submersible pump 1.5 HP and supply fix with new open well submersible pump horizontal type 1.5 HP capacity,single phase,2880 rpm,50hz,head-30 meter,discharge-3.42 lps complete to match the existing and connecting up with existing control / electric system including all accessories complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out unserviceable control panel and supply fix with new control panel for RO plant complete to match the existing and connecting up with existing control / electric system including all accessories complete all as specified and directed by Engineer-in-Charge.
Supply and demonstration of chlorine residual test kit portable digitally operated range 0.1-1 PPM and 0.6 to 6 PPM with enclosure & orthodin solution bottle 500 ml capacity complete all as spificied and directed.
Taking down old existing CPVC pipes , supply & lay CPVC pipes medium grade with all fittings laid in floors or fixed to walls and ceilings etc. of size 40 mm complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out unserviceable sand core from FRP filter and supply fix with new sand core in FRP Filter of RO plant complete to match the existing and connecting up with existing system including all accessories complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out unserviceable carbon media from FRP filter and supply fix with new carbon media for water softner in FRP Filter of RO plant complete to match the existing and connecting up with existing system including all accessories complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out unserviceable FRP Housing of membrane and supply fix with new FRP Housing of membrane for supporting and balanceing existing membrane of RO plant complete to match the existing and connecting up with existing system including all accessories complete all as specified and directed by Engineer-in-Charge.
M & L for Rewinding of unserviceable induction motor of 1.5 HP capacity 3 phase 50 Hz 415volt complete comprises as under :- (a) Disconnecting & removing the electric motor from installed position including, loading, unloading and transporting to approved workshop. (b) Taking out the existing burnt winding from the motor including rewinding complete with super enameled copper winding wire of existing gauge including all insulating material such as insulation paper, sleeves, tape, varnish etc. complete for class 'F' insulation. (c) Transporting the motor back to the location, reinstalling in original position including alignment, electrical & water connection, commissioning and testing for 8hours continuously to check the RPM etc. to the satisfactory performance etc. complete. NOTE: Any damage caused during handling will be made good by contractor without any extra cost to department
M & L for Detecting the gas leakage, rectifying the defects by vacumizing and charging fresh mafron gas and commissioning and testing the window type air conditioner unit 1.5Ton capacity complete all as specified and directed.
All as per item No 125 above but of 2.0 Ton capacity
All as per item No 125 above but of Split type AC 1.5 Ton Capacity.
All as per item No 125 above but of Split type AC 2.0 Ton Capacity.
All as per item No. 125 above but of Water cooler 40/60/80 Ltrs. Capacity.
All as per item No. 125 above but of Refrigerator 100/165/180/230 Ltrs. Capacity.
M & L for Taking out window type Air conditioner 1.0/1.5/2.0Ton capacity of any make from its original location, removing the dust from body with blower, cleaning the condenser and cooling coil by using water and caustic soda, painting the base tray with one coat of black enamel paint checking all the connections including functioning of metal clad socket/ DP switch function of relay capacitors overload protector thermostat fan motor blade fan blower drum etc. oiling/ greasing of fan motor checking serviceability and refixing it in its original place including testing commissioning for 1.0/1.5/2.0 Ton of AC of any make complete all as specified and directed.
All as per item No 131 above but of split type AC 1.5/2.0 Ton capacity complete out door and indoor unit.
M & L for preparation of old painted surfaces of Refrigerator any capacity by complete scraping old painting an applying two coat of synthetic enamel painting on outer surface (spray painting) as per existing colour and black colour on bottom portion such as compressor etc. over a coat of red oxide primer complete all as specified and directed.
M & L for preparation of old painted surfaces of Water cooler any capacity by complete scraping old painting an applying two coat of synthetic enamel painting on outer surface (spray painting) as per existing colour and black colour on bottom portion such as compressor etc. over a coat of red oxide primer complete all as specified and directed.
Supply, install, test & commissioning new compressor sealed reciprocating type suitable for window type AC 1.5 Ton capacity duly charged with fresh Refrigerant gas etc. complete all as specified & directed by Engineer-in-charge. Make : Voltas / Shriram / Tech cum Shah / Kirloskar/Carrier etc. as per existing make at site.
All as per item No 135 above but of 2.0 Ton capacity
All as per item No. 135 above but of Split type AC 1.5 ton capacity
All as per item No. 135 above but of Split type AC 2.0 ton capacity
All as per item No. 135 above but of Refrigerator 100/165/180/210 Liters Capacity.
All as per item No. 135 above but of Water coolers 40 / 60 /80 Liters capacity
Taking down carefully split type AC of capacity 1.5 / 2.0 ton & refixing on new location complete with pre fabricated brackets/ frame work as required complete & making the good existing surface with out any damage out & indoor unit complete all as specified and directed.
Removing the existing unserviceable coil burnt fan motor from window/Split type AC of capacity 1.0 / 1.5 / 2.0 Ton and replacing the same with brand new fan motor of same capacity including connecting up and testing complete all as specified and directed.
S & F fan motor suitable for water cooler of any capacity including removing old fan motor and testing complete all as specified and directed.
Supply,fixing and testing fan blade suitable for window/split type Air conditioner of 1.0 / 1.5 / 2.0 Ton capacity including removing old fan blade complete all as specified and directed..
Supply, fixing and testing fan blade suitable for water cooler of any capacity including removing old fan blade complete all as specified and directed..
Replacing old defective blower drum and supply & fix blower drum suitable for window type Air conditioner of 1.0 Ton / 1.5 Ton / 2.0 Ton capacity complete all as specified and directed..
Replacement of front cover grill suitable for window type AC 1.0 Ton / 1.5 Ton / 2.0 Ton capacity AC of various makes.
Replacement of starting capacitor 60 - 80 mfd.
Replacement of starting capacitor 80-100 mfd.
Replacement of starting capacitor 100 -120 mfd.
Replacement of running capacitor 25 MFD
Replacement of running capacitor 36 MFD
Replacement of running capacitor 45 MFD
Supply & fix of thermostat switch for window type AC of capacity 1.0 Ton / 1.5 Ton / 2.0 Ton capacity complete all as specified and directed.
Supply & fix of thermostat switch for split type AC of capacity 1.5 Ton / 2.0 Ton capacity complete all as specified and directed.
Supply & fix of thermostat switch for Refrigerator of any capacity complete all as specified and directed.
Replacement of thermostat switch for Water Cooler of any capacity complete all as specified and directed.
Taking out old unserviceable and Supply & Fix new over load relay suitable for Window/Split type AC of 1.0 Ton / 1.5 Ton / 2 Ton capacity complete all as specified and directed.
Taking out old unserviceable and Supply & Fix new over load relay suitable for water cooler of any capacity complete all as specified and directed.
Taking out old unserviceable and Supply & Fix new over load relay suitable for Refrigerator of any capacity complete all as specified and directed.
S & F of Float valve suitable for Water cooler of any capacity complete all as specified and directed.
Supply fixing and clamping jointing copper tubing for suction line and for liquid discharge line duly insulated with suitable insulation material including making hole in wall for passing through and making good to the disturbed surface complete all as specified and directed.
Supply and lay cable PVC insulated 3 core 4 Sq mm with copper conductor cable suitable for indoor unit to outdoor unit complete all as specified and directed.
Supply and lay PVC pipe 20 mm dia heavy duty for drain out condensing water of split AC including cutting of floor / opening of hole in wall and making good after laying of pipe etc match the existing surface complete all as specified and directed.
S & F push cock / lifting cock of 15 mm bore in repair for water cooler of any capacity complete all as specified and directed.
S & F GI water tray 3 mm thick for window type AC any capacity with out let system connection provided with PVC pipe of 20 mm dia up to 3 meter length connecting to drain pipe complete all as specified and directed..
Supply & Fix PVC drain pipe with necessary saddles of 25 mm size to be used as out let drain to be fixed complete all as specified and directed.
Supply and fix sheet metal enclosure with 2 pin and earth plug and socket complete with single pole MCB of 20 Amps complete all as specified and directed.
Taking out old unserviceable condenser coil of 1.5 Ton window type AC any make with sins cutting in let outlet connecting copper pipe and providing new condensor coil with sins and connecting in let out let copper pipe by bracing and replacement of nut bolts complete all as specified and directed.
All as per item No 170 above but for 2.0 ton window type AC complete all as specified and directed.
All as per item No.170 above but for 1.5 ton Split type AC complete all as specified and directed.
All as per item No 170 above but for 2.0 ton Split type AC complete all as specified and directed.
Removing electronic unserviceable circuit boards from window type AC 1.5 ton / 2.0 Ton capacity and replacing with new circuit boards and connecting with system with replacing remote control hand set and testing complete all as specified and directed
All as per item No. 174 above but for 1.5 Ton / 2.0 Ton Split type AC complete all as specified and directed
Supply & Fix blower fan motor capacitor 4 MFD complete all as specified and directed.
Supply & Fix blower fan motor capacitor 6 MFD complete all as specified and directed.
M & L for replacement of damaged outer cover for window type Air conditioner of any capacity and size made out of GI sheet of 20SWG complete all as specified and directed.
Taking out existing unserviceable over load protector and Supply & Fix new over load protector for 1.0 /1.5 /2.0 Ton capacity window type Air Conditioner
Supply and fix in repair sensor remote plate(PCB) suitable for 1.5/2.0 Ton capacity split type AC complete all as specified and directed.
Supply of sensor remote handset suitable for 1.5/2.0 Ton capacity split type AC complete all as specified and directed.
Taking out old unserviceable cooling coil of window/split type AC any capacity and any make with sins cutting in let outlet connecting copper pipe and providing new cooling coil with sins and connecting in let out let copper pipe by bracing and replacement of nut bolts complete all as specified and directed.
Supply & fix Condensing unit Bracket of any size and type suitable for supporting to out door unit of split type AC including nut, bolts & washers complete all as specified and directed.
Supply and fix in replacement Contactor of split type AC any capacity complete all as specified and directed.
Supply and fix in replacement suction & liquid line valve of size (5/8"&1/4")/(5/8"&3/8") suitable for split type AC complete all as specified and directed.
Repair/eplacement of indoor unit of split type AC 1.5TR capacity having 3 star rating complete with all accessories such as installation plate with screw, blower motor, swing notor, filter and PCB etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc all as specified and directed. (Note :- Old indoor unit will be deposied to MES (E/M) Store yard.
Repair/replacement of outdoor unit of split type AC 1.5TR cap having 3 star rating complete with all accessories such as hermetically sealed compressor, condenser unit,capacitor, relay, fan motor etc duly prewired including reconnecting of existing refrigerant piping, electrical connection,etc complete all as specified and directed. (Note :- Old Outdoor unit will be deposied to MES (E/M) Store yard
Part -I Manning & operation of Central AC Plant two in number 32.5 TR make Kirloskar run at a time one compressor and one stand by for smooth functioning of entire system and to maintain the specific temperature 20+2ºC, RH 50+5% AC plant consists of the following items fitting/ fixtures/ device components for operation at Epoxy coating workshop boat pool 8hrs daily except Sunday and Holiday in one shift.(i.e 0800 To 1600 Hrs) one AC plant operator per shift and taking care cleaning etc any pilferage, theft or damage etc complete all as directed:- (a) Compressor make Kirloskar -02Nos. (b) Compressor motor HBB 50HP-02Nos. (c) Condenser water pump set mono block 7.5HP - 02 Nos. (d) Air handling unit with blower motor 10HP-01No. (e) AHU motor 10HP HBB-01No. (f) Cooling tower induced draft type -01No. (g) Electrical control panel cubical type floor mounted with maint switch MCBs voltmeter, Ammeter, Starter condenser etc. complete-01Set. (h) Control devices such as expansion valve thermostat solenoid valves HP/LP/CP cuts out with panel board installed gauges-01 Set (j) Digit type thermometer-01Set (k) Air supply duct with grill diffusers, dampers and heater etc. complete-01Set (l) Condensor MS piping 100mm with valves, pressure gauge, temperature gauge complete-01Set
Manning & operation of Central AC Plant of water cooled chillers 3Nos. x 50 TR (Two running,one standby) Total 150 TR make: voltas for smooth functioning of entire system and to maintain temperature of AC plant consists of the following items fitting/ fixtures/ device components for operation at INS SHIKRA . 16 hrs daily including Sunday and Holiday in two shift.(i.e 0600 to 1400 Hrs,1400 to 2200 Hrs ) one AC plant operator per shift and taking care cleaning etc any pilferage, theft or damage etc complete for the following:- (a) Compressor model No. ACCWC05000MNT-03 Nos. (b) Compressor motor 60HP-03Nos (c) Condenser / chiller water pump set mono block 10/7.5HP-04Nos. (d) Air handling unit with blower motor -01No. (e) FRP Cooling tower with CT Fan-01No. (f) Control devices such as expansion valve thermostat solenoid valves HP/LP/CP cut outs with panel board installed gauges -01Set. (g) Digit type thermometer-01 Set. (h) Air supply duct with grill diffusers dampers and heater etc. complete-01Set. (j) Condenser piping MS 100/80/50mm dia with valves, pressure gauge, temperature gauge -01Set
Note :- for 188 & 189 (i) contarctor shall submit ID proof,police verfication,Bank A/C deatils ,Educational certificate to departmnet and obtain approval from Enginner-in-charge before employing person as a AC plant opeartor . (ii) Payment should be done by crossed cheque through aadhar linked bank account only and it shall not be less than minium fair ewages as per act in vogue.The contractor should submit proof of payment before claming payment. (iii)An minimum qualification for AC plant operator not to be less than ITI or equivalent certified courses from state/Central govt recognized institute. (iv) Contarctor has to submit proof of payment of group insurance subscription made by him as applicable as per latest laws/acts before claming RAR. (v) Contarctor should provide two set of uniform ,shoes to each employed person.
PART-II Comprehensive maintenance of Central Air conditioning Plant of capacity 32.5TR X 2Nos comprising of following equipment mentioned under including cleaning, securing, gearing the merable parts of pump motors and painting of plants motor, cooling towers and pipes, cleaning of cooling tower etc complete all as specified and directed by Engineer-in-Charge at Boat Pool Workshop:- (a) Compressor make Kirloskar -02Nos. (b) Compressor motor HBB 50HP-02Nos. (c) Condenser water pump set mono block 7.5HP - 02 Nos. (d) Air handling unit with blower motor 10HP-01No. (e) AHU motor 10HP HBB-01No. (f) Cooling tower induced draft type -01No. (g) Electrical control panel cubical type floor mounted with maint switch MCBs voltmeter, Ammeter, Starter condenser etc. complete-01Set. (h) Control devices such as expansion valve thermostat solenoid valves HP/LP/CP cuts out with panel board installed gauges-01 Set (j) Digit type thermometer-01Set (k) Air supply duet with grill diffusers, dampers and heater etc. complete-01Set (l) Condensor MS piping 100mm with valves, pressure gauge, temperature gauge complete-01Set
Comprehensive maintenance inclduing Sundays & Holidays of central AC plant of water cooled chillers 3Nos. x 50 TR (Two running,one standby) Total 150 TR make: voltas, model No. AC WC05000MNT at INS SHIKRA complete with cooling tower AHU & other accessories for for the following:- (a) Compressor model No. ACCWC05000MNT-03 Nos. (b) Compressor motor 60HP-03Nos. (c) Condenser / chiller water pump set mono block 10/7.5HP-04Nos. (d) Air handling unit with blower motor -01No. (e) FRP Cooling tower with CT Fan-01No. (f) Control devices such as expansion valve thermostat solenoid valves HP/LP/CP cut outs with panel board installed gauges -01Set. (g) Digit type thermometer-01 Set. (h) Air supply duet with grill diffusers dampers and heater etc. complete-01Set. (j) Condenser piping MS 100/80/50mm dia with valves, pressure gauge, temperature gauge -01Set.
PART-III Material and labour for pumping down and transfer existing refrigerant gas of compressor complete for over hauling of compressor, reciprocating open type Model No. AC- 470 Make:Kirloskar 32.5Ton capacity and dismantling complete assembly & replacing of minor unserviceable parts including matching of crank shaft boring polishing etc. replacing of gaskets packing reassembly and recharging of pumped down refrigerant & topping up if required, maintain the required standing pressure charging of compressor oil complete testing for smooth functioning etc complete all as specified and directed by Engineer-in-Charge at Epoxy work shop Boat Pool. Note: (Major spare parts, compressor oil and refrigerant for topping up will be measured and paid seperately herein after as supply only).
Material and labour for pumping down and transfer existing refrigerant gas of compressor complete for over hauling of compressor, reciprocating open type Model No. 5H20 Make:Voltas 50Ton capacity and dismantling complete assembly & replacing of minor unserviceable parts including matching of crank shaft boring polishing etc. replacing of gaskets packing reassembly and recharging of pumped down refrigerant & topping up if required, maintain the required standing pressure charging of compressor oil complete testing for smooth functioning etc complete all as specified and directed by Engineer-in-Charge at INS Shikra. Note: (Major spare parts, compressor oil and refrigerant for topping up will be measured and paid seperately herein after as supply only).
Supply only following items for compressor reciprocating model No AC-470. Make :- Kirloakar 32.5 ton and compressor reciprocating model No.5H20 Make :- Voltas 50 ton capacity
Main bearing
Liner assembly
Piston rings
Piston Oil rings
Piston pins
Suction valve reeds
Suction valve reed springs
Discharge valve reeds
Discharge valve reed spring
Discharge valve guide assembly
Connecting Rod
Oil filter inner/ outer
Discharge valve retaining plate
Piston
Oil regulating valve
Connecting rod bearing of two
Loading/ unloading valves
Loading/ unloading rings
Crankshaft
Oil pump Assembly
Oil pump bush
Solenoid coil valve assembly
Taking down old unserviceable shaft seal assembly complete and supply and fix new shaft seal assembly suitable for 32.5 TR capacity central AC Plant all as directed by Engineer-in-Charge
Taking down old unserviceable shaft seal assembly complete and supply and fix new shaft seal assembly suitable for 50TR capacity central AC Plant all as directed by Engineer-in-Charge
Material and labour for expansion valve of AC plant capacity 32.5TR including taking down unserviceable valve complete all as specified and directed by Engineer-in-Charge at Boat pool.
Material and labour for expansion valve model no- MV-52 of AC plant capacity 50TR including taking down unserviceable valve complete all as specified and directed by Engineer-in-Charge at Boat pool.
Material and labour for pumping down the plant to preserve the existing in refrigerant gas & leak testing of plant by charging of nitrogen gas in to entire plant & monitoring for 24hrs to find the leakages, rectification of leak by brazing & replacement of necessary gasket packing wherever required including copper tubes of suitable size vacumising of the plant by vacum pump & keeping 24hrs for testing including rectification of leakages if any finally recharging of existing refrigerant gas to the plant and topping up of refrigerant if required to maintain the standard pressure complete testing of the plant for smooth functioning complete all as specified & as directed by Engineer-in-Charge.
Dismantling AHU of 3 x 50TR capacity AC plant carefully by removing side and top panel removing unserviceable blower shaft bearings,removing motor & blower assembly, replacement of new AHU blower shaft bearings reassembling blower assembly and refixing electric motor & top side panel in original position with new nut bolts washers & shafts keys & checking the shafts balancing & testing for smooth running all as specified and directed at INS SHIKRA.
Dismantling AHU of 2 x 32.5 TR capacity AC plant carefully by removing side and top panel removing unserviceable blower shaft bearings,removing motor & blower assembly, replacement of new AHU blower shaft bearings reassembling blower assembly and refixing electric motor & top side panel in original position with new nut bolts washers & shafts keys & checking the shafts balancing & testing for smooth running all as specified and directed at Boatpool
Removing the unserviceable liquid line valve of size 25mm dia from the liquid line after pumping down the compressor & supply and fixing new liquid line valve 25mm dia including connected works as required for smooth functioning of AC plants complete all as specified and directed by Engineer-in-Charge
Material and labour for dismantling FRP cooling tower of capacity 50x3 TR at INS Shikra by removing CT Fans, sprinklers, PVC filler and clean cooling tower body by removing scale , dust, dirt and refix PVC filler by cleaning with diluted HCL solution reassembling, connecting , cleaning external surface and applying two coats of approved synthetic enamel paint including writing SM number/ marking and testing etc. complete all as specified and directed
Material and labour for dismantling FRP cooling tower of capacity 1x32.5 TR at Boatpool by removing CT Fans, sprinklers, PVC filler and clean cooling tower body by removing scale , dust, dirt and refix PVC filler by cleaning with diluted HCL solution reassembling, connecting , cleaning external surface and applying two coats of approved synthetic enamel paint including writing SM number/ marking and testing etc. complete all as specified and directed
Taking out old unserviceable cooling tower fills sheets from the site and supply and fix new fibre fills sheet of same size for cooling tower as per the existing at site and all as specified and directed
Taking out old unserviceable cooling tower nozzles and supply and fix new cooling tower nozzles suitable for cooling tower as per existing
Material and labour for disconnecting condenser for descaling, plugging them & providing of 15mm tee out let for local circulation of mild acid solution in the condenser (separate container and small pump set to circulate diluted acid solution to be used) PH value of solution to be circulated & to be kept 4 and checking frequently i.e. every one hour during the operation Scalgun WS solution to be used for descaling purpose after 2 to 3 hours of cleaning if ph value remains less than 7flush with fresh water mixed with sodium carbonate tubes and cleaning with nylonbrush after closing the end covers, circulating diluted acid solution as specified above, to maintaine PH value as above & flushing the same with fresh water including recharging of stored refrigerant up to required pressure complete all as specified & directed by Engineer-in-Charge.
Replacement of Compressor Oil with new Compressor oil of Frizol 68 all as specified and directed by Engineer-in-Charge.
Removing old unserviceable discharge valve 25mm dia and supply and fix new discharge valve of size 25mm dia suitable for R-22 gas discharge line all as specified & directed.
Supply and fix in replacement of unserviceable / wornout 'V' belt of compressor, AHU etc of make fenner Dunlop / Nurlon as approved
Taking down old existing MS pipes, supply, lay and welding MS pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc. of sizes 125 mm dia complete all as specified & directed by Engineer-in-Charge.
Taking down old existing MS pipes, supply, lay and welding MS pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc. of sizes 100 mm dia complete all as specified & directed by Engineer-in-Charge.
Taking down old existing MS pipes, supply, lay and welding MS pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc. of sizes 80 mm dia omplete all as specified & directed by Engineer-in-Charge.
Taking down old existing GI pipes, supply, lay and welding GI pipes medium grade with all fittings laid in floors or fixed to walls and ceilings etc. sizes of 100 mm dia complete all as specified & directed by Engineer-in-Charge.
Taking down old existing GI pipes, supply, lay and welding GI pipes medium grade with all fittings laid in floors or fixed to walls and ceilings etc. sizes of 80 mm dia complete all as specified & directed by Engineer-in-Charge.
Taking down old existing GI pipes, supply, lay and welding GI pipes medium grade with all fittings laid in floors or fixed to walls and ceilings etc. sizes of 50 mm dia omplete all as specified & directed by Engineer-in-Charge.
Removing the unserviceable solenoid valve 5/8" flare from the liquid line and supply and fix new solenoid valve 5/8" suitable for AC plant of various capacities complete with all as specified and as directed by Engineer-in-Charge
Supply and fix in repairs CI Butter fly valve slim seal design with nitrile rubber lined seal with clutch lever (P10 or PN 16) as per IS 13095 of size 125 mm bore complete all as specified & directed by Engineer-in-Charge.
Ditto - as per item No 217 above but 100 mm bore.
Ditto - as per item No 217 above but 80 mm bore.
Ditto - as per item No 217 above but 65 mm bore.
Taking down old unserviceable Non Return valve and supply and fix new CI Non Return valve of size 100 mm Bore. complete all as specified & directed by Engineer-in-Charge.
Ditto - as per item No 221 above but 80 mm bore.
Ditto - as per item No 221 above but 65 mm bore.
Taking down old unserviceable Strainer of any make and size and supply and fix new Strainer of size 100 mm Bore.complete all as specified & directed by Engineer-in-Charge.
Ditto - as per item No 224 above but 80 mm bore.
Supply and fix Condensor safety valve suitable for chiller unit all as specified and directed by Engineer-in-Charge.
Removing old unserviceable over load relay assembly and supply fixing new overload relay assembly of same make and capacity all as directed.
Removing old unserviceable timer and supply & fix NewTimer for Condenser motor all as specified & directed.
Supply and charge refrigerant Gas as per requirement.complete all as specified & directed by Engineer-in-Charge.
Removing old unserviceable power contactor and supply & fix new power contactor 3TF-47 all as specified & directed by Engineer-in-Charge
Removing old unserviceable power contactor ML-1.5and supply & fixing new power contactor ML-1.5 all as specified & directed.
Removing old unserviceable power contactor ML-2 and supply & fixing new power contactor ML-2 all as specified & directed.
Removing old unserviceable power contactor ML-3 and supply & fixing new power contactor ML-3 all as specified & directed.
Removing old unserviceable Auxilary contactor and supply & fix new Auxilary contactor all as specified & directed by Engineer-in-Charge.
Removing old unserviceable power contactor and supply & fix new power contactor MNX -32 all as specified & directed by Engineer-in-Charge
Removing old unserviceable power contactor and supply & fix new power contactor MNX -40 all as specified & directed by Engineer-in-Charge
Removing the unserviceable pressure gauges HP/LP/OP from existing position and supply and fixing new pressure gauge of capacity 0 to 30Kg. / square centimeter complete with necessary accessories all as specified & directed by Engineer-in-Charge
Removing the unserviceable water pressure gauges from water line & supplying and fixing new water meter up to pressure 0-7Kg. / square centimeter complete with necessary accessories all as specified & directed by Engineer-in-Charge
Material and labour for scraping cleaning & preparation of external surface & painting complete installation of 32.5 x 2 TR (65TR capacity) including compressor, motor, piping, cooling tower, condensor, AHU & panel board etc with two coats of synthetic enamel paint over a coat of primer as per direction on colour code as given including writing SM & MES numbers complete all as per specified & as directed by Engineer-in-Charge
Material and labour for scraping cleaning & preparation of external surface & painting complete installation of 50 x 3 TR (150TR capacity) including compressor, motor, piping, cooling tower, condensor, AHU & panel board etc with two coats of synthetic enamel paint over a coat of primer as per direction on colour code as given including writing SM & MES numbers complete all as per specified & as directed by Engineer-in-Charge
Material and labour for cleaning complete DX type cooling coil of AHU with chemical solution caustic soda to remove impurities dust and foreign materials, complete with nylon brush and cleaning cooling coil with fresh water complete all as specified & directed for the cooling coil section of AHU AC plant
Material and labour for disconnecting for Chiller descaling & Plugging them & providing of 15 mm tee outlet for local circulation of mild acid solution in the Chiller (separate container and small pump set to circulate diluted acid solution to be used) PH value of solution to be circulated & to be kept 4 and checking frequently i.e. every one hour during the operation Scalgun WS solution to be used for descaling purpose after 2 to 3 hours of cleaning if ph value remains less than 7, flush with fresh water mixed with sodium carbonate tubes and cleaning with nylon brush after closing the end covers, circulating diluted acid solution as specified above & PH value to be maintained as above & flushing the same with fresh water including recharging of stored refrigerant up to required pressure of 3x50 TR capacity at INS Shikra ACplant complete all as specified & directed by Engineer-in-Charge.
Material and labour for repairs to Microprocessor of 50 TR Capacity chiller unit including replacing diods , transistors and wiring etc for AC Plant at INS SHIKRA all as specified and directed
Material & Labour for LP/HP/OP cut out KP-1 Including taking down old one. Make:- Indofoss complete all as specified & directed by Engineer-in-Charge.
Removing the unserviceable solenoid coil and Supply and fix new solenoid coil suitable for AC plant of various capacities complete with all as specified and as directed
Removing the unserviceable chiller water sensor and supplying and fixing new chiller water Sensor of suitable capacity complet all as specified & directed by Engineer-in-Charge
Removing the unserviceable pressure Sensor HP / LP / OP from and supplying and fixing new pressure Sensor of suitable capacity complet all as specified & directed by Engineer-in-Charge
Supply and errect factory fabricated rectangular square duct made out of 24 gauge GI sheet in L shaped hollow profile including all accessories such as corner, carriage bolt hangers, gasket and seal the longitudinal joints with and including approved sealant complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable insulation from any surface and supply and fix nitrile rubber insulation of one layer of 19mm thickness sticking on surface by using approved adhesive and sealing the joints by weather proof tape all as directed by Engineer-in-Charge.
Dismantling and takingout old unserviceable cooling tower and Supply & install, commissioning of New brand Draft rectangular counter flow type Cooling tower body of capacity 65 TR Comprising of FRP casing FRP fan stack,FRP Fan,PVC header with branches totally enclosed weather proof enclosure complete testing all as directed by Engr in Charge.Make : Mihir Engineers Pvt Ltd./ Advance cooling Tower Ltd /Paharapur cooling tower Ltd.
Spare parts of Draft rectangular counter flow type Cooling tower of capacity 65 TR such as Electric Motor, PVC Fills,PVC Eliminators, MSHDG Structure and necessary Hardware etc. including addition alteration to water inlet and outlet pipe connection Complete testing all as directed by Engr in Charge.
Taking down old unserviceable AHU pre filter and Supply and fix new pre filters (EU-4)synthetic non oven type efficiency 90% down to particular size of 10 micron double knitted twisted polymer fabric (washable) rated with press drop of 6 mm WC to be mounted in AHU filter assembly size as per existing. Make: ASPAWYMAN/DYNA/MHP as approved
Material and labour for framed work with structural steel sections including nuts, bolts,washers, welding ,bending cold or hot, drilling holes for bolts, in any shape or size as directed including applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified.
Rewinding of unserviceable electric motor 3 phase 50 Hz 415volt of following capacity pump set complete comprises as under :- (a) Disconnecting & removing the electric motor from installed position including, loading, unloading and transporting to approved workshop. (b) Taking out the existing burnt winding from the motor including rewinding complete with super enameled copper winding wire of existing gauge including all insulating material such as insulation paper, sleeves, tape, varnish etc. complete for class 'F' insulation. (c) Transporting the motor back to the location, reinstalling in original position including alignment, electrical & water connection, commissioning and testing for 8hours continuously to check the RPM etc. to the satisfactory performance etc. complete. NOTE: Any damage caused during handling will be made good by contractor without any extra cost to department
20 HP Chiller Water Pump Motor .
15 HP Condenser Water Pump Motor.
5.0 HP Condenser Water Pump Motor.
50 HP Compressor Motor .
60 HP Compressor Motor .
10 HP AHU Blower Motor .
Over hauling of Monoblock pump set after removing from the base plate, disconnecting from pipe line, dismantling the pump set, replacing unserviceable gland packing, gun metal bush bearing water seal applying grease etc. complete and reassembling the pump set connecting with pipe line reconnection of electric supply, including buts bolts, gaskets etc. complete testing of pumps for smooth functioning with following capacity of pumps and motors:-
20 HP Chiller Water Pump Motor .
15 HP Condenser Water Pump Motor.
5.0 HP Condenser Water Pump Motor.
50 HP Compressor Motor .
60 HP Compressor Motor .
10 HP AHU Blower Motor .
Maintenance and Labour for complete overhauling of Air Compressor having Model No-22526259-80, Make: ATLAS COPCO and motor of 150H.P Capacity along with associated fittings and following mentioned as under all as specified and directed by EIC at integrated Boat centre Boat pool workshop (i)Dismantling, removal, overhaul, repairs and reassembly of twin screw compressor.(ii)Dismantling, and inspection of bearings and seals, replacement as required .(iii)Dismantling, overhaul and assembly of compressor drive motor (150HP)(iv) Dismantling & overhaul of compressor deliver valve.(v)Dismantling, cleaning of tubes, reassembly and testing of lubricating oil cooler.(vi)Dismantling, cleaning of tubes, reassembly and testing of discharge air cooler.(vii)Dismantling , cleaning, and testing of oil and water seperator.
Supply only for the following items for Air compressor . Model No. 22526259-80Make: ATLAS COPCO:location:Baotpool
Mechanical seals of compressor
Rotor Screw bearings
Air inlet filter elements
Oil filter catridges
Oil filter catridge O-rings,
Air temperature gauge
Air pressure gauge 0-150 PSI/ 0-12bar.
Oil and water seperator catridge.
Bearings for drive motor
Maintenance and labour for complete overhauling of Winch and motor including following jobs are mentioned as under all as specified and directed by EIC.(i)Dismantling of Rope Drum, overhaul of rope drum bearings, replacement of support bushings/ bearings, reassembly and testing.(ii)Machining/ polishing of band brake drum, replacement of band brake liner pad, including removal, transportation of drum to workshop & back.(iii)Dismantling and overhaul of Winch gear box, worm and wheel type, Make Radicon(iv)Dismantling, and overhaul of drive motor self-braking arrangement and replacement of brake shoe liners, reassembly and testing.(v)Chipping and Painting of complete Winch assembly using one coat primer & three coats of enamel paint.
Supply only for the following items for Winch and motor:-
Brand brake liner for rope drum with rope wire as per existing size
Brake liner shoes for Motor brake
Motor bearings
Rope Drum bearing bushes
Primer, Epoxy red oxide
Paint, enamel light grey
Set of bearings for Winch Gear Box.
Maintenance and labour for repairs to the Winch trolley as follows as under all as specified and directed by EIC:-(i)Chipping and removal of old paint and prepairing the trolley surface standard ST12.(ii)Painting complete with one coat primer and three coats of enamel paint.(iii)Minor structural repairs for strengthening, as envisaged after removing old paint and chipping
Supply, repairs/ replacement for the following items for Winch Trolley:-
Primer, Epoxy Red oxide
Paint, Epoxy Black Anti corrosive, Marine grade
Paint, Epoxy Black fouling Marine grade
Steel plate for repair of Trolley structure, 6mm IS 2062Gr B
Wheel Bearings Bushes
Fasteners for wheel Bearing locking plate.
Note for Item No. 107, 188 & 189 (i) Passes will be processed only after verification of antecedence of deployed employees and submission of verified experience certificate, Pass shall not be granted without submission of qualification proof & experience certificate. (ii) Contractor shall submit ID proof, Residential proof, Bank A/C details to department and obtain approval of Engineer-in-Charge before employing a person as Operator (iii) Payment to employees shall be done by crossed cheque through Aadhaar linked bank account only and it shall not be less than minimum fair wages as per act in vogue. The contractor shall submit proof to Engineer-in-Charge before claiming any payment. (iv) AC and RO plant Operator shall be available as per the shift timings specified in the tender and he will report to JE E/M in-Charge. In case of emergency he will function according to their direction. If he is found absent or move without intimating to in-Charge or JE E/M he will be treated as absent for the said shift and recovery to this effect for Rs 1500/- per shift shall be affected.(v) Payment as per quoted rate shall also be deducted in addition to the penalty as specified above. (v) The individual employed as operator should has minimum qualification of ITI course equivalent from state or central board
(vii) Contractor shall submit the labour licenece VAT as applicable as per latest laws/acts & Copy of GST Regn registered number issued by concerned authority. (ix) Contractor has to submit proof of payment of EPF subscription made by him as applicable as per latest laws/acts alongwith RAR failing which RAR will not be progressed for payment. (x) The rates quoted by the contractor shall be deemed to be included provision of all latest labour laws / regulations including all relevant taxes as applicable. (xi) The bidders are advised not to quote rate less than minimum fair wages as circulated by competent authority. If the quoted amount is less than the estimated cost of work mentioned in BOQ item No 107.00, 188, 189.00 i.e Rs 2163480.00, the lowest bidder will have to deposit FDR/BGB as elaborated herein after in favour of Accepting Officer within 07 days of opening of financial bid (Cover No 2). The deposited amount shall be the difference between estimated cost mentioned in BOQ item No 107.00,188.00, & 189.00 (i.e) Rs 2163480.00 and amount quoted by lowest bidder. FDR/BGB shall be released only after satisfactory completion of work. If the contractor fails to pay minimum wages to employees, the department shall have right to withhold the said amount which will be verified by GE. The decision of Accepting Officer regarding amount to be withhold shall be final and binding. The withhold amount will be utilised by GE for payment to employees if contractor fails to pay minimum wages and balance amount if any shall only be released. If the lowest bidder fails to deposit the amount as stated above within 07 days, the contractor shall be banned for 06 months & his bid shall be rejected. The contractor shall sumbit 03 Nos of BGBs/FDRs of equal amount as mentioned above. The BGBs/FDRs validity shall be 04 months, 08 month & 12 months respectively for the purpose of encashment/ release as the case may be. (xii) The rates quoted shall be inclusive of suitable reliver wherever sundays & holidays are mentioned for working
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .