Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.4 LAccepted-AOC NO 3 JANI JAN KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | L1 | Accepted-AOC Being the lowest tenderer and fulfilling all the criteria | |
| 2 | L2₹51.4 L+₹2.4 L (4.90%)Rejected-Finance NO 5 3 JJ KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | TAMIL NADU | 600014 | L2 | Rejected-Finance Not being the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
10 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Chennai
Garrison Engineer Fort Saint George Chennai - 600009
ADDITION/ ALTERATION TO BUILDING NO. P-1 DINNING HALL OF AREA OFFICERS MESS AND CERTAIN OTHER SANCTIONED WORKS UNDER GE CHENNAI
2021_MES_459392_1
8527/E8
Open Tender
Civil Works
Item Rate
183 days
Fort Saint George
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Chennai
₹94,000
Yes
8 Sept 2021
13 Jul 2021
16 Aug 2021
13 Jul 2021
10 Aug 2021
27 Jul 2021
60 days
Amount
BOQ UPLOADED ON 21 JUL 2021
Surface dressing not exceeding 15cm deep and getting out in soft/ loose soil complete all as specified and directed.
Excavation in trenches in soft/ loose soil n. exc. 1.50m wide and n. exc. 1.50m deep for foundation, or for shafts, wells, cesspits, manholes, laying cable etc. n. exc. 10 sqm on plan getting out complete all as specified and directed.
Returning filling in including spreading, leveling, watering & well ramming in layers not exceeding 25cm thick in soft/ loose soil complete all as specified and directed.
M&L sand filling under floors or in foundation including watering, well ramming & consolidating in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated soil to a distance n. exc. 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for providing PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for providing RCC M-30 (design Mix) using graded stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc., basement slabs, under reamed piles and mass concrete complete all as specified and directed.
M&L for providing RCC M-30 (design Mix) using graded stone aggregate as in columns, pillars, piers, posts and struts etc., complete all as specified and as directed.
M&L for providing RCC M-30 (design Mix) using graded stone aggregate as in roof beams, cantilevers, bressummers, lintels complete all as specified and directed.
M&L for providing RCC M-30 (design Mix) using graded stone aggregate as in roof slabs supported on walls, beams and columns in floors, roofs, deck slabs and the like complete all as specified and directed.
M&L for providing RCC M-30 (design Mix) using graded stone aggregate as in chajja complete all as specified and directed.
M&L for precast RCC (1:1½:3) type A-1 using 20mm graded aggregate as in manhole covers, landings etc. with plain faces set in cement mortar (1:4) complete all as specified and directed.
M&L for precast RCC (1:1½:3) type A-1 using 20mm graded aggregate as in chajjas with plain faces set in cement mortar (1:4) complete all as specified and directed.
M&L for brickwork with old size fly ash bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with old size fly ash bricks straight or curved on plan to any radius in half brick thick walls in cement mortar (1:4) complete all as specified and directed.
M&L for granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
Use and waste of formwork to foundations, footings, bases of columns, rafts & raft beams, sides & soffits of foundation & plinth beams and similar works; vertical or batter for rough finished surface of concrete complete all as specified and as directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished surface of concrete square, rectangular or polygonal complete all as specified and as directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam hunching, girders, bressummers, lintels, cantilevers, including supports, overhangs, etc. also splays between floors and beams complete of flat rough finished surfaces of concrete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work, not exc. 200mm thick (Horizontal or sloping) for fair finished surfaces of concrete flat complete all as specified and directed.
Use and waste of formwork to edges of concrete flats, breaks in floors, window cills, concrete railing and openings in concrete wall; floors and roofs and similar works exc. 10cm but n. exc. 20cm wide for rough finished surfaces of concrete all as specified and directed.
Use and waste of formwork to chajjas, challah hoods, troughs and similar works complete all as specified and directed.
M&L for rounding to edges of stone slabs, such as in steps, cooking platform and other similar situations all as specified and directed.
Taking down chowkats (or) frames of any description with shutters (without taking off shutters from the frame) of area n. exc. 1.5 sqm each including separating guard bars/ grills/ wire mesh etc. complete all as specified and directed.
Taking down chowkats (or) frames of any description with shutters (without taking off shutters from the frame) of area exc. 1.5 sqm but not exc. 4sqm each including separating guard bars/ grills/ wire mesh etc. complete all as specified and directed.
Taking down shutters of any description n. exc. 1 Sqm each and re-securing in the same opening after cutting, easening etc with new iron mongry complete all as specified and as directed.
Taking down shutters of any description exc. 1 Sqm but n. exc. 2 Sqm each and resecuring in the same opening after cutting, easening etc with new iron mongry complete all as specified and as directed.
M&L for second class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and as directed.
S&F second class hard wood, plain framed, 35mm thick panelled shutters (any number of panels) with rails and panel of 12mm thick veneered particle board with commercial veneering on both faces, the size of rail and stile are as per IS 1003 (part I) Kiln seasoned and chemically pressure treated and fitted to chowkats complete all as specified and as directed.
S&F second class hardwood glazed and skeleton door shutters, 30mm thick divided into squares, open rebated and prepared to receive glass, gauge etc., with sash bars, edges of framing plain, chamfered, rounded fitted with cut and mitred beads for securing glass etc., size of members as specified in SSR Part 1 section 8 clause 8.24 (a) supplied and fitted to chowkats complete all as specified and as directed.
S&F for 2nd class hardwood glazed and skeleton window/ ventilator shutters 30mm thick divided into squares open rebated and prepared to receive glass, gauge etc. edges of framing plain, chamfered, rounded fitted with cut and mitered beads for securing glass etc., size of members as specified in SSR Pt 1 section 8 clause 8.24 (b) supplied and fitted to chowkats with plain, chamfered or rounded mitered and rebated sash bars any numbers, complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube all as per relevant details given in SSR against item No. 08095 of SSR Part-II and fitted to chowkats complete all as specified and as directed.
S&F factory made solid PVC moulded door shutter with wood free EPS 28 to 30mm thick with 2, 4 or 6 raised panel design with 2mm thick moulded PVC sheet on back face, supplying and fixing in frame at site complete all as specified, directed and shown in sketch for item No. 8103 in SSR Part-II.
S&F 12mm thick toughened glass as in fixed window including necessary fixing arrangement at top and bottom complete all as specified and directed.
M&L 12mm thick toughened glass door including floor spring, ‘D’ type handle, locking arrangement, top & bottom pivot etc. complete all as specified and directed.
S&F mild steel butt hinges, medium weight cold rolled 75mm size all as specified and directed.
S&F mild steel butt hinges, medium weight cold rolled 100mm size all as specified and directed.
S&F aluminium anodised barrel tower bolts of extruded section 125mm long all as specified and directed.
S&F aluminium anodised barrel tower bolts of extruded section 200mm long all as specified and directed.
S&F extruded aluminium alloy handles fabricated type anodised 125mm size all as specified and directed.
S&F extruded aluminium alloy handles fabricated type anodised 150mm size all as specified and directed.
S&F aluminium alloy anodised sliding door bolts 300mm long with hasp, staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded sections complete all as specified and directed.
S&F aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.4mm fixed with aluminium wire staples fixed to wooden frames complete all as specified and directed.
S&F aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.4mm fixed with aluminium wire staples fixed to wooden frames fixed in repairs complete all as specified and directed.
S&F aluminium powder coated designer curtain rods (draw berms rods) 19mm dia exterior grade, 3mm thick with holding clamps and fixed to wall with PVC rawl plug and brass screws complete all as specified and directed.
S&F aluminium powder coated designer brackets for curtain rod suitable for aluminium powder coated designer curtain rod all as specified and directed.
S&F rolled mild steel roof trusses (framed), trussed purlins, crane gantries, rails & fastenings & heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. Gde Fe 410-W (Gde-E-250) quality-A complete all as specified and directed.
M&L for mild steel work in bands, straps, supports of stays, sunshade brackets, hook and pintle hinges, clamps, hold fasts, guard bars, grills bolts etc. and similar conforming to FE-290, Gde E 165 complete all as specified and directed.
S&F framed work such as grills, gratings etc., with ends of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks & similar work conforming to Fe 290 Gde-E-165 complete all as specified and directed.
M&L for 10mm dia and over mild steel TMT bars as in reinforcement cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-500D complete all as specified and directed.
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-500D complete all as specified and directed.
S&F powder coated aluminium (minimum thickness of powder coating 50 micron) frames for doors/ windows/ ventilators/ partitions etc. with one or more rebates including joining cleats for fixing complete all as specified and directed.
S&F anodized aluminium powder coated (minimum thickness of powder coating 50 micron) panelled door shutter of aluminium section for frame work not less than 0.55 Kg/ RM including necessary joining cleats, glazing clips, rubber neoprene packing, 2 No. 150mm long handles, 02 No. 200mm long tower bolts, 03 No. aluminium B21 hinges and 01 No. aluminium mortice lock in each door, fully glazed for providing glass panes, pre-laminated particle boards etc. including anodized aluminium snap beads, screws etc. including panel inserts of 9mm thick particle board, interior grade, pre-laminated on one side with decorative choice laminations and other side with balancing white laminations fixed with snap beads/ screws and complete all as specified and directed. Note: Glass panes and pre-laminated particle board shall be measured and paid for separately under appropriate item of this BOQ.
M&L for 9mm thick pre-laminated particle board, interior grade, pre-laminated on one side with decorative choice laminations and other side with balancing white laminations fixed with snap beads/ screws to aluminium frame work as in panel inserts all as specified and directed.
S&F providing Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approximate 900mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm c/c complete all as specified and directed.
S&F hangers 6mm dia. GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified
M&L for providing and fixing gypsum board 10mm thick in ceiling fixed to GI frame work with screw as per manufacturer’s instructions including provision of 1 to 2mm thick wall care putty and two coats of plastic emulsion paint over a coat of primer with paper tape joint filling complete all as specified and directed. Make: Gyproc Board or equvalent from other makes specified in particular specifications. Note: Metal framework shall be measured and paid for separately.
S&F pre-laminated particle board 18/ 19mm thick, exterior grade pre-laminated on one side with decorative choice lamination and other side balancing white lamination fixed with screws as in cupboard shutters and shelves etc. complete all as specified and directed.
S&F Pre-painted galvalume aluminium zink coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength 550Mpa as in roof covering fixed with self-tapping screws as per manufacturer’s instruction complete all as specified and directed.
M&L for cleaning the top surface of roof with wire brushes, removing all dust, dirt etc. and applying APP modified prefabricated polymeric membrane, 3mm thick of weight not less than 3.6Kg/ Sqm reinforced with non woven polyester matt, black finished on cold sticker and torch application of membrane with 10cm over lap after necessary preparation of roof surface over 10mm thick screed in cement mortar (1:4) when concrete is green with WPC as per manufacturer's instructions including water proofing treatment consisting of the following all as specified :- (i) One coat of bitumen primer @ 0.40 Kg/Sqm. (ii) One coat of bonding material of blown type bitumen of grade 85/25 heated with working temperature of 180 degree Cent and applied @ 1.20 Kg per square meter of the surface area. (iii) A layer of APP modified polymeric membrane of specified thickness and weight. (iv) Top most layer of surface finished with one coat of heat resisting aluminium paint. (v) Rate of WPC shall be inclusive in the quoted rate and nothing extra will be paid.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store & rubbish off the premises complete all as specified.
M&L Non skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exc. 0.06 Sqm but n. exc. 0.11 Sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 20mm thick screed bed in cement mortar (1:4) complete all as specified and as directed.
M&L Non skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exc. 0.11 Sqm but n. exc. 0.18 Sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 20mm thick screed bed in cement mortar (1:4) complete all as specified and as directed.
M&L coloured glazed ceramic tiles 7 to 8mm thick of size 300mm x 450mm as approved by GE laid on vertical surfaces set and jointed in neat cement slurry and pointed in coloured cement to match the tile laid over and including 10mm thick backing coat in cement mortar (1:3) complete all as specified and as directed.
M&L exterior designer ceramic wall tiles of size 300mm x 200mm x 7mm/ 450mm x 300mm x 7mm thick laid on vertical surfaces set and jointed in neat cement slurry and pointed in coloured cement to match the tile laid over and including 10mm thick backing coat in cement mortar (1:3) complete all as specified and as directed.
M&L for vitrified light shade coloured ceramic tiles 8 to 10mm thick (Square/ Rectangle) area of each tiles exc. 0.42 sqm but n. exc. 1.00 sqm as in floors etc.; set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
M&L for coloured chequered (Designer) cement concrete tiles 40cm x 40cm x 25mm thick set, jointed and pointed in neat cement slurry as in floors with grey cement and no pigment laid over and including 20mm thick screed bed in cement mortar (1:4) including dismantling of existing tiles complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base of floor finished fair and even complete all as specified and as directed.
M&L for 75mm thick PCC (1:3:6) type C-1 using 20mm stone graded aggregate as in plinth protection including filling of joints by bitumen and sand in ratio (1:2) complete all as specified and directed.
M&L for treating Kota stone flooring/ skirting with bee wax polish all as specified and directed.
M&L for 2.00mm thick PVC tiles/ sheets, laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in floors complete all as specified and directed.
Taking down cement plaster on brick work or stone walls etc. including racking out of joint, hacking for key, scrubbing down with water etc. and removing the debris outside MD land complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:6) on fair faces of brick work and surface finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L rendering 15mm thick in two coats i.e. 1st coat 10mm thick in cement mortar (1:6) and 5mm thick finishing coat in cement mortar (1:4) mixed with and including PIDI PROOF LW compound @ 200ml per bag and finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L rendering 5mm thick in cement mortar (1:3) on ceiling finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L preparation of newly plastered or previously untreated surface of walls and applying three coats of white wash complete all as specified and directed.
M&L for complete removal of existing treatment from surface of walls and applying two coats of oil bound distemper over and including a coat of primer and a coat of 2 to 3mm thick wall care putty including preparation of newly plastered or previously un-treated surface complete all as specified and directed.
M&L for preparation of newly plastered surface of walls and applying two coats of plastic emulsion paint of (Royale emulsion of Asian) over and including a coat of white primer and 2 to 3mm thick wall care putty complete all as specified and directed.
M&L for complete removal of existing treatment from wall surface with electric blade, washing, rubbing down and stopping and applying two coats of weather proof exterior acrylic emulsion paint (Apex Ultima of Asian or equivalent of other specified makes) over a coat of white primer complete all as specified and directed.
M&L for preparation of old decorated plastered surfaces of ceiling including brooming down or by steel wire brushing, scrapping down smoke soot, moss and efflorescent salts and treating oil & greasy spots and applying two coats of white wash complete all as specified and as directed.
S&F sheet glass 4mm thick plain ordinary quality and glazing with oil putty/ wooden beads as directed in squares n. exc. 0.50 Sqm in each pane complete all as specified and directed.
S&F sheet glass 4mm thick plain ordinary quality and glazing with oil putty wooden beads as directed in squares n. exc. 0.50 Sqm in each pane as including hacking out old broken glass complete all as specified and directed.
M&L preparation of new steel surfaces of any description not otherwise described over 10cm girth or width and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L for preparation of new wooden or wood based surface of any description exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, steel and iron works new or old treating ends of posts, back of chowkats etc. with tar or coal tar black paint area tarred exc. 0.1 sqm but n. exc. 0.5sqm each complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, steel and iron works new or old treating small articles such as hold fast etc. with tar or coal tar black paint area tarred n. exc. 0.1sqm each complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint on old painted steel surfaces not exceeding 10cm girth or width of any description and in any situation including preparation of surfaces complete all as specified and as directed.
M&L for removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers from wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S&F vitreous china wash basin white flat back size 550mm x 400mm (excluding taps, waste, chain and plug and porcelain stopper) but including brackets and 32mm dia PVC coupling fixed in repairs complete all as specified and directed.
M&L vitreous china wash down water closet pedestal pattern white with including white coloured PVC seat cover including connections to drain (or outgoing pipe) and flush pipe etc. fixed in repairs complete all as specified and directed.
S&F PVC valve less, symphonic action type low level flushing cistern 10 litre with complete accessories such as PVC flush pipe, over flow pipe etc. fixed in repairs complete all as specified and directed.
S&F 15mm PVC connection 450mm long with PTMT nuts of superior quality fixed in repairs all as specified and directed.
S&F 15mm dia bib taps brass chromium plated, fancy type, long body with flange with crutch or butterfly handle screwed down, screwed for iron pipes or for brass ferrule and fixed in repairs complete all as specified and directed.
S&F 15mm dia bib taps with flange, cast copper alloy, fancy type chromium plated with crutch or butterfly handle screwed down, screwed for iron pipes or for brass ferrule all as specified and directed. Make: Jaquar Cat No. QQT-7037 or equivalent from other makes specified in particular specifications.
S&F fancy type pillar tap cast copper alloy with capstan heads chromium plated screwed down, high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts screwed for 15mm bore iron pipe fixed in repairs complete all as specified and directed.
S&F angle valve/ stop valve, cast copper alloy, chromium plated, fancy type with long shank & cup (concealed type), screwed down, high pressure with crutch or butterfly handle, screwed both ends for 15mm bore iron pipe or for union complete all as specified and directed.
All as per item No. 96.00 above but fixed in repairs.
S&F 500 ltr capacity three layered rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position including dismantling existing OHT complete all as specified and directed.
S&F gun metal, globe or gate valve with iron wheel head, screwed both ends for 25mm bore iron pipe and fixed in repairs complete all as specified and directed.
S&F gun metal, globe or gate valve with iron wheel head, screwed both ends for 20mm bore iron pipe and fixed in repairs complete all as specified and directed.
S&F in repairs ball brass valve for 25mm bore pipe high pressure with polyethylene high density float and fly nut complete screwed for iron pipe complete all as specified and directed.
S&F in repairs health faucet (hand shower) with 1.0metre long PVC tube with wall hook, chromium plated as per Cat No. BEA-40 of Prayag or equivalent from other makes specified in particular specifications complete all as specified and directed.
S&F 600mm x 450mm bevelled edged looking mirror 6mm thick with aluminium frame work fitted with 6mm thick commercial ply or AC sheet backing to mirror and fixed to wall with raw plugs and chromium plated brass screws and cup washers etc., fixed in repairs complete all as specified and directed.
S&F 900mm x 950mm bevelled edged looking mirror 6mm thick with aluminium frame work fitted with 6mm thick commercial ply or AC sheet backing to mirror and fixed to wall with raw plugs and chromium plated brass screws and cup washers etc., complete all as specified and directed.
S&F stainless steel 1mm thick sink kitchen or laboratory overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm with plugs, washers, wastes including bedding in cement mortar on to dwarf wall or on cantilever brackets and connecting union to pipe complete all as specified and directed.
S&F galvanized steel water tubing 15mm bore medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls, concealed in walls/ ceilings or laid in floors etc., complete all as specified and directed.
S&F galvanised steel water tubing 15mm bore medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls, concealed in walls/ ceilings or laid in floors etc. including taking up or down the existing GI tubing complete all as specified and directed.
S&F galvanised steel water tubing 20mm bore medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls, concealed in walls/ ceilings or laid in floors etc. including taking up or down the existing GI tubing complete all as specified and directed.
S&F galvanised steel water tubing 25mm bore medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls, concealed in walls/ ceilings or laid in floors etc. including taking up or down the existing GI tubing complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor etc. complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including demolition and breaking up existing pipe complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor etc. including demolition and breaking up existing pipe complete all as specified and directed.
S&F PVC (SWR) vent cowl 110mm bore all as specified and directed.
S&F PVC (SWR) bend 110mm dia any radius with access door all as specified and directed.
S&F PVC (SWR) branch piece double (double 'Y') equal or unequal 110mm bore with access door complete all as specified and directed.
S&F PVC (SWR) junction double (double 'T') equal or unequal 110mm bore with access door complete all as specified and directed.
M&L for PVC (SWR) floor trap 110mm dia plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repair PTMT grating 100mm dia as per cat No. 111 of Prayag or equivalent from other makes specified in particular specifications complete all as specified and directed.
Demolition of PCC in ground floor and paving n. exc. 15cm thick including removal of debries outside MD land complete all as specified and directed.
Demolition of brick masonry built in cement mortar including all quoins, arches, pillars, ashlars facings, dressed stone work and pre cast concrete articles etc., complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons, kitchen shelves etc. (laid, bedded and pointed in any mortar) complete all as directed and specified.
Dismantling asbestos cement/ galvalume (corrugated, semi corrugated etc.) sheets in roof covering all as specified and directed.
Dismantling structural steel work un-framed as in roof members all as specified and directed.
Taking down old unserviceable/ damaged point wiring carefully of any size and description on teak wood batten/ through pipe (light, fan, socket etc) including removal of battens, pipes/ conduits, sockets, switches, shades, ceiling fittings, bulk head fittings ceiling rose etc complete and making good disturbed portion of wall to match with the existing surface all as specified and directed.
M&L for point wiring complete with 1.5sqmm (nominal area) PVC insulated unsheathed multi-stranded, (two run for Phase and Neutral) copper conductor FRLS grade cable of 1100V grade conforming to IS-694 drawn through and including new non-metallic rigid PVC conduit medium grade, ISI marked, 20mm bore with conduit accessories concealed In wall/ floor and fixed on ceiling/ roof etc. mounted in modular metal boxes with cover plate and frame for housing the switch sockets, outlets, fan regulator etc. including provision of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly etc., complete all as specified and directed for:-
One light/ fan point controlled by one switch.
One 3 pin 5 amps socket outlet on the same board with other switches controlled by one switch.
One 3 pin switch socket outlet, 5 Amps on independent board controlled by one switch.
Bell/ buzzer point controlled by one bell push.
One light point controlled by two No. 2-way switches.
M&L for point wiring complete with 2.5sqmm (nominal area) PVC insulated unsheathed multi-stranded, (two run for Phase and Neutral) copper conductor FRLS grade cable of 1100 V grade conforming to IS-694 drawn through and including new non metallic rigid PVC conduit medium grade, ISI marked, 20mm bore with conduit accessories concealed In wall/ floor and fixed on ceiling/ roof etc. mounted in modular metal boxes with cover plate and frame for housing the switch sockets including provision of 2.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly complete all as specified for one socket outlet (plug point) three pin 15 Amps controlled by one switch 15 Amps on independent board complete all as specified and directed.
M&L for point wiring complete with 1.5sqmm (nominal area) PVC insulated unsheathed multi-stranded, (two run for Phase and Neutral) copper conductor FRLS grade cable of 1100V grade conforming to IS-694 drawn through and including new non-metallic rigid PVC conduit medium grade, ISI marked, 20mm bore with conduit accessories concealed In wall/ floor and fixed on ceiling/ roof etc. including new pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc. including provision of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly etc., complete all as specified and directed for:-
One light/ fan point/ exhaust fan point controlled by one switch.
One 3 pin 5 amps socket outlet on the same board with other switches controlled by one switch.
One 3 pin switch socket outlet, 5 Amps on independent board controlled by one switch.
Bell/ buzzer point controlled by one bell push.
One light point controlled by two No. 2-way switches.
M&L for point wiring complete with 2.5sqmm (nominal area) PVC insulated unsheathed multi-stranded, (two run for Phase and Neutral) copper conductor FRLS grade cable of 1100 V grade conforming to IS-694 drawn through and including new non-metallic rigid PVC conduit medium grade, ISI marked, 20mm bore with conduit accessories concealed In wall/ floor and fixed on ceiling/ roof etc. including pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc. including provision of 2.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly complete all as specified for one socket outlet (plug point) three pin 15 Amps controlled by one switch 15 Amps on independent board complete all as specified and directed.
S&F modular switch one way, 6 Amps, 1 module all as specified and directed.
S&F modular socket outlet, 6 Amp, 2/ 3pin combined, 2 module all as specified and directed.
S&F modular switch one way, 16 Amps, 1 module all as specified and directed.
S&F modular socket outlet, 3 pin, 6 Amp/ 16 Amp, 2 module all as specified and directed.
S&F modular switch two way, 6 Amp, 1 module all as specified and directed.
S&F modular TV socket, 1 module all as specified and directed.
S&F modular telephone socket, 1 module all as specified and directed.
S&F card base key, 20 Amp key tag with time delay electronic type 2 module complete all as specified and directed.
S&F ceiling rose PVC/ polycarbonate body 65 x 50mm 2 to 3 terminals 230 Volts, AC Single phase all as specified and directed.
Supply and fix call bell/ buzzer multi tune, 230 volts AC all as specified and directed.
S&F modular bell bush, 6 Amp, 1 module all as specified and directed.
Supply and fix lamp holder insulated body with back plate for batten fittings/ angle holder as required complete all as specified and directed.
S&F modular fan step regulator, 120 watt, 2 module all as specified and directed.
Supply and fix switch piano, flush type, single pole, one way, 5 Amps, 230 volts all as specified and directed.
Supply and fix bell push, flush type, single pole, 5 Amps, AC, 230 volts all as specified and directed.
Supply and fix switch piano, flush type, single pole, two way, 5 Amps, 230 volts all as specified and directed.
Supply and fix switch socket combination, 2 in 1, 5 Amps, 230 volts flush type all as specified and directed.
Supply and fix switch socket combination, 2 in 1, 3 pin, 5/ 15 Amps, 230 volts universal flush type all as specified and directed.
Supply and fix call bell of multi music type, single pole, AC, 230 volts all as specified and directed.
S&F stepped flush type electronic ceiling fan regulator 300 watt all as specified and directed.
S&F turbo force 4 blade (300mm sweep) exhaust fans AC single phase 230/ 240 volts, heavy duty corrosion resistant body rigid frame with rubber mountings for minimal noise operation & maintenance free design with pressure die cast aluminium rotor mounted on two ball bearings with maximum air with minimum power consumption conforming to IS: 2312-1967 complete all as specified and directed.
Supply & fix exhaust fans AC single phase 230/ 240 V of size 250mm sweep with louver fan complete all as specified and directed.
Supply & fix wall mounted fan AC single phase 230/ 240 V of size 400mm sweep all as specified and directed. Make: Havells Cat No. FHWSUSTGRY16 or equivalent from other specified makes.
S&F high speed BEE 5 star rated standard plain ceiling fan of 1200mm sweep (colour as approved by GE) 230V, 50HZ single phase fixed with suitable clamp and down rod (GI Pipe) including drilling, bolts and nuts including taking down existing ceiling fan and depositing in store yard of AGE E/M complete all as specified and directed.
Supply and hanging 1250mm sweep ceiling fan with dust resistant coating, reinforced ABS blades, 18 pole motor with LED under light and remote control including provision of 3 core flexible copper conductor cable of size 23/0.19 from ceiling rose to fan complete all as specified and directed.
S&F geyser 25 litre capacity, five star rating, 2KW power rating, white colour including grouting suitable nuts & bolts, flexible PVC pipes for hot & cold water and three core 2.5 sqmm flexible cable with plug top for connection from power point to terminal of geyser complete all as specified and directed.
Supply, installation, testing and commissioning 1.5 TR capacity split AC, BEE 5 star rated comprising of indoor and outdoor unit type including provision of piping with necessary clamps, nuts, bolts etc. as required complete all as specified and directed. Make: LG/ VOLTAS/ SAMSUNG/ O- GENERAL
Supply and fix 22 watts LED light fitting surface and wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver including taking down old fitting complete all as specified and directed. Make: Havells cat No. ENDURALINERNEOBS22WLED865SPCWH or equivalent from Philips/ CG.
S&F 42 watts environment friendly, new generation, aesthetically, ultra-modern designed recess mounting luminaire with high brightness SMD LEDs as light source suitable for Armstrong/ Grid ceiling fixed to ceiling complete all as specified and directed. Make: Havells cat No. PLUTONEO2X2PLR42WLED857S or equivalent from other makes specified in Particular Specifications.
S&F 34 watts environment friendly, new generation, aesthetically, ultra-modern designed recess mounting luminaire with high brightness SMD LEDs as light source suitable for Armstrong/ Grid ceiling fixed to ceiling complete all as specified and directed. Make: Havells cat No. PLUTONEO2X2PLR34WLED857S or equivalent from other makes specified in Particular Specifications.
Supply and fix 10 Watts LED surface mounted downlight with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency complete all as specified and directed. Make: Havells Cat No. INTEGRANEOSURFACEDLS10WLED857S or equivalent of other specified makes.
Supply and fix 10 watts LED light fitting surface and wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver complete all as specified and directed. Make: Havells cat No. ENDURALINERNEOBS10WLED865SPCWH or equivalent of other specified makes.
Supply and fix 8 watts decorative wall mounting CFL lamp fitting with housing made of SS sheet with cup shaped glass diffuser including lamp complete all as specified and directed. Make: Havells Cat No. LHJE01106499 or equivalent from other specified makes.
S&F 25 watts environment friendly, new generation, LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07 including provision of two single core 2.5 sqmm copper conductor PVC insulated cable complete all as specified and directed. Make: Havells cat No. ENDURAPEARLSL25WLED757SASYTOPCMP or equivalent from other makes specified in Particular Specifications.
Supply and fix environmental friendly, ultra modern, energy saving, surface mounted 10 Watts LED decorative oval bulkhead edge-lit LED luminaire comprising of high brightness fixed in repairs complete all as specified and directed. Make: Havells Cat No. RUGBYNEONFT 10WLED860SSYMTOPC or equivalent of other specified makes.
S&F batten type luminaries with CRCA body, pre-coated in white and pre-wired for single LED tube light of capacity 22 Watts including LED tube with and including flexible twin core copper conductor 23/0.0076mm from ceiling rose to connector of tube light fitting fixed in repairs complete all as specified and directed. Make: Havell's Cat Part No. LUMILINEPLUSBS22WLED865S0CSS or equivalent of other specified makes.
S&F LED 10 watts mirror light with diffuser all as per Cat No. LCL-10-CDL of Crompton Greaves or BN 550 WLED 12 - 6500 of Philips or LHESABP6IN1W009 of Havells or equivalent of other specified makes fixed in repairs complete as specified and directed.
S&F adjustable angle wall mounting 12 watts LED light all as specified and directed. Make: Havell's Cat Part No. LHFXZNNTN1W013 or equivalent of other specified makes
S&F surface/ pendent down lighter with white/ black powder coated polycarbonate housing and pressure die-cast heat sink all as specified and directed. Make: Havell's Cat Part No. CYLINDROPROPENDTDLP25WLED840S45DBLK or equivalent of other specified makes
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole MCB 20 Amps, 240V complete all as specified and directed.
M&L for submain wiring complete with two runs of 4.0 Sqmm single core, multi-stranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including new rigid non metallic PVC conduit medium grade 20mm dia concealed in wall/ floor along with conduit fittings and accessories, fixed on ceiling with one run of 4.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified. Note: Two runs of 4.0sqmm multi-stranded cable and one run of 4.0sqmm cable as earth continuity conductor alongwith PVC conduit shall be considered as one unit length.
M&L for submain wiring complete with two runs of 10.0 Sqmm single core, multi-stranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including new rigid non metallic PVC conduit medium grade 20mm dia concealed in wall/ floor along with conduit fittings and accessories, fixed on ceiling with one run of 10.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified. Note: Two runs of 10.0sqmm multi-stranded cable and one run of 10.0sqmm cable as earth continuity conductor alongwith PVC conduit shall be considered as one unit length.
M&L for submain wiring complete with two runs of 6.0 Sqmm single core, multi-stranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including new rigid non metallic PVC conduit medium grade ISI marked 25mm external dia concealed in wall/ floor along with conduit fittings and accessories, fixed on ceiling with one run of 6.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring complete all as specified. Note: Two runs of 6.0sqmm multi-stranded cable and one run of 6.0sqmm cable as earth continuity conductor alongwith PVC conduit shall be considered as one unit length.
S&F rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3mm thick burried directly in ground vertically to a depth not less than 2.25m deep below ground level with top edge of plate not less than 1.5 below ground level connected to GI 4mm earth wire by means of bolts, nuts check nuts washers made of galvanised iron or steel earth wire protected by GI pipe 15mm bore light grade connected upto switch board including 20mm bore GI water pipe with funnel and wire mesh all as shown in electrical plate No. 3 of MES Schedule Part-I including dearth chamber of PCC (1:2:4) type B-1 using 20mm grade aggregate with 40mm thick RCC cover slab (1:1½:3) type A-0 using 12.5mm graded stone aggregate reinforced with 8mm dia TMT bars @ 100mm c/c both ways and 6mm dia MS lifting hooks including testing on completion complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3mm thick burried directly in ground vertically to a depth not less than 2.25m deep below ground level with top edge of plate not less than 1.5 below ground level connected to GI 4mm earth wire by means of bolts, nuts check nuts washers made of galvanised iron or steel earth wire protected by GI pipe 15mm bore light grade connected upto switch board including 20mm bore GI water pipe with funnel and wire mesh all as shown in electrical plate No. 3 of MES Schedule Part-I including dearth chamber of PCC (1:2:4) type B-1 using 20mm grade aggregate with 40mm thick RCC cover slab (1:1½:3) type A-0 using 12.5mm graded stone aggregate reinforced with 8mm dia TMT bars @ 100mm c/c both ways and 6mm dia MS lifting hooks including testing on completion including dismantling existing earthing complete all as specified and as directed.
Supply, lay/ spread in trenches clean dry sand to required width and depth at bottom and top of cable including spreading, levelling, punning for laying/ cushioning of cable all as specified and as directed. Note: Punned thickness only will be considered for payment.
Supply and laying burnt bricks, old size, sub class 'B', laid flat abutting each other, perpendicular to cable with width equal to width of brick laid in trenches for protection of cable all as specified and directed.
Supply and laying in trenches, fixed on wall (or) passing through pipes/ in floors including connecting up, testing and commissioning of XLPE insulated screened PVC bedded galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 Sqmm 2 core complete all as specified and directed.
All as per item No. 176.00 above but cable of size 35 sqmm 3½ core.
Supply and laying in trenches, fixed on wall (or) passing through pipes/ in floors including connecting up, testing and commissioning of XLPE insulated screened PVC bedded galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3½ core including taking out old cable complete all as specified and directed.
All as per item No. 178.00 above but cable of size 50 sqmm 3½ core.
All as per item No. 178.00 above but cable of size 70 sqmm 3½ core.
All as per item No. 178.00 above but cable of size 95 sqmm 3½ core.
All as per item No. 178.00 above but cable of size 120 sqmm 3½ core.
All as per item No. 178.00 above but cable of size 150 sqmm 3½ core.
All as per item No. 178.00 above but cable of size 185 sqmm 3½ core.
All as per item No. 178.00 above but cable of size 240 sqmm 3½ core.
Supply and laying GI tube light grade 40mm bore with all fittings laid in trenches/ floor for cable protection and for drawing earth strip/ earth lead wire etc., complete including taking down old pipe complete all as specified and directed.
Supply and laying GI tube light grade 50mm bore with all fittings laid in trenches/ floor for cable protection and for drawing earth strip/ earth lead wire etc., complete including taking down old pipe complete all as specified and directed.
Supply and laying GI tube light grade 80mm bore with all fittings laid in trenches/ floor for cable protection and for drawing earth strip/ earth lead wire etc., complete including taking down old pipe complete all as specified and directed.
M&L boring under the road for crossing UG cable including supply and laying 80mm bore medium grade GI pipe complete all as specified and directed.
M&L taking out existing LT underground cable PVC/ XLPE insulated 1100 volts grade of size 95 sqmm to 150 sqmm and re-fixing in panel by providing 4 No. aluminium lugs with crimping tools including providing insulation tap around the burnt cable complete all as specified and directed.
M&L taking out existing LT underground cable PVC/ XLPE insulated 1100 volts grade of size 185 sqmm to 240 sqmm and re-fixing in panel by providing 4 No. aluminium lugs with crimping tools including providing insulation tap around the burnt cable complete all as specified and directed.
M&L cable jointing kit for 1100 volts grade cable for straight through heat shrink type joints complete with jointing material and accessories suitable for 240 sqmm 3½ core to 300 sqmm 3½ core XLPE armoured aluminium conductor cable complete all as specified and directed.
M&L cable jointing kit for 1100 volts grade cable for straight through heat shrink type joints complete with jointing material and accessories suitable for 150 sqmm 3½ core to 185 sqmm 3½ core XLPE armoured aluminium conductor cable complete all as specified and directed.
Supply, fix, connecting and testing MCCB four pole 100 Amps, 415 volts breaking capacity, 25kA with adjustable thermal setting conforming to IS: 13947-II fixed in existing panel complete all as specified and directed.
Supply, install, test & commissioning LT panel outdoor, floor mounted/ pedestal type, cubical, self-supported, CPRI approved make, front and rear openable, double door hinged type with locking arrangement and suitable ventilations on both sides with wire mesh, IP-65 protection, fabricated out of 3mm CRCA sheet duly powder coated, mounted/ fixed on and including MS angle iron stand of 50cm height above ground, fabricated out of 50mm x 50mm x 6mm thick MS angles duly painted with black enamel synthetic paint over a red oxide primer duly grouted in PCC (1:3:6) type C-2 using graded stone aggregate as in foundation, control wiring copper stranded PVC insulated FRLS cables not less than 1.5sqmm, interconnection of suitable size/ capacity of copper strips for switch gear connection from main bus bar four run including earth bus strip of 300A capacity for entire length of panel, suitable size of MS gland with gland plate and aluminium lugs/ thimbles for all incoming/ outgoing cables etc. fixed with and including the followings complete:
Supply, fixing, connecting and testing factory made, MCB distribution board, made of 1.2mm thick CRCA sheet, powder coated paint conforming of IS - 13032, double door flush type fixed in switch boards/wall at various places of capacity 415 Volts, 4 way, (MCB DB), TPN with 200 Amps rated Bus Bar neutral link, earth bar and din rail etc. conforming to IP 38 protection complete all as specified and as directed. Note: MCB’s shall be measured and paid separately.
All as per item No. 196.00 but fixed in repairs.
Supply, fixing, connecting and testing factory made, MCB distribution board, made of 1.2mm thick CRCA sheet, powder coated paint conforming of IS - 13032, double door flush type fixed in switch boards/wall at various places of capacity 415 Volts, 4 way, (MCB DB), SPN with 200 Amps rated Bus Bar neutral link, earth bar and din rail etc. conforming to IP 38 protection including taking down existing DB complete all as specified and as directed. Note: MCB’s shall be measured and paid separately.
Supply, fixing, connecting and testing factory made, MCB distribution board, made of 1.2mm thick CRCA sheet, powder coated conforming of IS - 13032, double door flush type fixed in switch boards/ wall at various places of capacity 240 Volts, 16 way, (MCB DB), SPN with 200 Amps rated bus bar neutral link, earth bar and din rail etc. conforming to IP 38 protection complete all as specified and as directed. Note: MCB’s shall be measured and paid separately.
Taking down old MCB all as specified and directed.
Supply, fixing, connecting and testing MCB isolator, four pole, 415 Volts, 4 pole, TPN, 63 Amps, all as specified and as directed.
Supply, fixing, connecting and testing MCB rating of 415 Volts, TPN, 63 Amps, all as specified and as directed.
Supply, fixing, connecting and testing MCB SPN, 32 Amps, 240 volts of rupturing capacity 10kA, C curve type complete all as specified and as directed.
Supply, fixing, connecting and testing MCB SPN, 40 Amps, 240 volts of rupturing capacity 10kA, C curve type complete all as specified and as directed.
Supply, fixing, connecting and testing MCB single pole (MCB SP), 6 to 32Amps, 240 volts of rupturing capacity 10kA, C curve type all as specified and as directed.
G.JANAKIRAMAN CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .