Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹100.3 CrAdmitted-Finance | -23.77% | ₹100.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹105.2 CrAdmitted-Finance FLAT NO 5 IIND FLOOR IIIRD B 2 NEHRU NAGAR GHAZIABAD UP 201001 | GHAZIABAD | GHAZIABAD | UTTAR PRADESH | 201001 | -20.00% | ₹105.2 Cr | L2 | Admitted-Finance |
| 3 | L3₹112.0 CrAdmitted-Finance | -14.87% | ₹112.0 Cr | L3 | Admitted-Finance |
| 4 | L4₹115.1 CrAdmitted-Finance | -12.50% | ₹115.1 Cr | L4 | Admitted-Finance |
| 5 | L5₹141.8 CrAdmitted-Finance | +7.79% | ₹141.8 Cr | L5 | Admitted-Finance |
Updated dates
Tender Value
₹131.5 Cr
EMD Value
₹1.3 Cr
Closing Date
5 Feb 2026, 5:00 pmClosed
Superintending Engineer
Office of the Superintending Engineer, Coonstruction Circe, U.P. Jal Nigam (Urban), Varanasi
Laying of Sewer Network, House Connection
2026_UPJNM_1103391_1
2736/08-081-005/203 Dated 26-12-2025
Open Tender
Civil Works - Others
730 days
Nagar Nigam
As per NIT/Tender Document
2 documents required · 2 mandatory
₹23,600
EE, CD-I, UP Jal Nigam (Urban)
₹1.3 Cr
SE, CC, UPJN(U), Varanasi
13 Mar 2026
1 Jan 2026
6 Feb 2026
1 Jan 2026
5 Feb 2026
1 Jan 2026
12 Jan 2026
Civil Work
Sewer Network
Excavation
Excavation for following depth below G.L. for laying of sewers in ordinary soil earth, sand, loam and clay including cutting of jointing pits, trimming dressing leveling refilling of trenches in 20cm layers watering and ramming the same including removal of surplus earth or other dismantled materials up to distance 50m from the center of trenches.
TIMBERING
Providing and fix open timbering (covering 1/3rd) of surface area by planks in trenches for the following depth below G.L. Consisting of 40 mm approved country wood planks for poling boards 125mm x 75mm Indian Sal wood walers and 100 mm dia. Sal ballies for shuttering at 1.5m c/c including removal after laying. Both sides will be taken as one side for the purpose of payment and measurements i.e. area equals to length x depth of trenches and dismantled timbering materials will be the property of the contractor.
Providing and fix close timbering in the trenches for the following depth below G.L. consisting of 40 mm approved country wood planks for poling broads 125 mm x 75 mm Indian Sal wood walers and 100 mm dia. Sal bellies for truing the shuttering at 1.5 M c/c/ including removal after laying of sewers. Both side of trenches will be taken as one side for the purpose of payment and measurement i.e. area equals to length x depth of trenches. Dismantled timbering materials will be the property of the contractor.
Laying of Sewer Network
Supply of following sizes of RCC NP3 S&S rubber rings joints pipe & rubber ring from factory to site of work, lowering gasket the same into trenches and laying true to the alignment and gradient including excavation of earth below invert level of pipes cost of all jointing materials, testing etc. complete. also including transportations loading, unloading, stacking all taxes excise duty transit insurance etc. complete.
NP3 200 mm dia pipe
NP3 250 mm dia pipe
NP3 300 mm dia pipe
NP3 350 mm dia pipe
NP3 400 mm dia pipe
NP3 450 mm dia pipe
NP3 500 mm dia pipe
NP3 600 mm dia pipe
NP3 700 mm dia pipe
NP3 800 mm dia pipe
Carting and Laying of following sizes of RCC NP3 S&S rubber rings joints pipe & rubber ring from factory to site of work, lowering gasket the same into trenches and laying true to the alignment and gradient including excavation of earth below invert level of pipes cost of all jointing materials, testing etc. complete. also including transportations loading, unloading, stacking all taxes excise duty transit insurance etc. complete.
NP3 200 mm dia pipe
NP3 250 mm dia pipe
NP3 300 mm dia pipe
NP3 350 mm dia pipe
NP3 400 mm dia pipe
NP3 450 mm dia pipe
NP3 500 mm dia pipe
NP3 600 mm dia pipe
NP3 700 mm dia pipe
NP3 800 mm dia pipe
Bedding
Cement concrete work in bedding below G.L. at specified depth with cement, coarse sand and 20 mm gauge approved stone ballast (1:2:4) including supply of all materials, labour, T&P etc. required for the proper completion of work.
Lean Cement concrete work in bedding below G.L. at specified depth with cement, coarse sand and 20 mm gauge approved stone ballast (1:4:8) including supply of all materials, labour, T&P etc. required for the proper completion of work.
Well graded crushed rock/ gravel max size 25mm including supply of all materials, labour, T&P etc. into the trenches for bedding of DWC/RCC Pipes including watering compaction, labour T&P etc. for completion of work.
Construction of circular type brick masonary/RCC manhole (with Extra Heavy Duty type manhole cover) with top slab made of cement concrete 1:1.5:3 with graded granite stone aggregate (12 mm nominal size), foundation concrete 1:4:8 graded stone aggregate other than granite 40mm nominal size, wall made of brick masonry using 1st class bricks having crushing strength between 100 to 149 kg/cm² in cement mortar 1:4 inside plastering 12 mm thick 1:3 finished smooth with neat cement, pinning, outside plaster 1:4 and making channels with cement concrete 1:2:4 graded granite stone aggregate (12 mm nominal size) complete as per specifications.
900mm internal dia., 1.65m deep
1200mm internal dia., 2.30m deep
1500mm internal dia., 4.95m deep
1800mm internal dia., 9.0 m deep
Same as item no 123 for Regulation of Shafts plus/minus from the above mentioned depth
900mm internal dia., 1.65m deep
1200mm internal dia., 2.30m deep
1500mm internal dia., 4.95m deep
1800mm internal dia., 9.0 m deep
Dismantling/Cutting of the following type of road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m.
Bituminous road
Concrete road
Interlocking tile road
B.O.E road
Permanent re-instatement of the following ty pe of road surface after laying of sewer line including supply of all materials, labour, T&P etc. required for completion of work. it also includes necessary excavation required for preparation of trench for reinstatement of road, disposal of surplus unserviceable material, watering, ramming, cleaning surface for proper completion of the work as per directions of Engineer ‐in ‐charge.
Bituminous road (PWD) -(20cm sand, 20cm GSB, 20cm WMM, 5 cm to 8 cm DBM, 3cm to 4 cm B.C.) payment made upto WMM- 50%, DBM- 30% and BC with testing in NABL aprooved lab/PWD- 20%
Bituminous road (Nagar Nigam) (20cm sand, 20cm GSB, 20cm WMM, 5 cm to 8 cm DBM, 3cm to 4 cm B.C.) payment made upto WMM- 50%, DBM- 30% and BC with testing in NABL aprooved lab/PWD- 20%
C.C. Road in M25 grade, minimum thickness 15cm on 20cm th. sand & 15 .cm th. PCC (M15) filling base & 10 cm GSB
Interlocking Road (existing usable Interlocking bricks M-30 grade, on 20cm local sand & 10cm TH. PCC 1:6:12). Incl. Entire surface Spreading 3 cm local sand for paste of brick & joint filling
BOE Road (15 Cm. sand with first class brick 50% New and 50% Old)
Supply of MS pipe (As per IS:3589 made from steel confirming to IS:2062), with anti corrosive treatment with P.U. coating and Installation of product pipe by HDD method including preparing and setting up the plants and equipment, preparing new pipe work material, installation new pipe-work and commissioning system or making the system ready for commissioning by HDD operation including, all related civil and mechanical works like excavation, shoring/strutting, etc. drilling, stringing, reaming, and pulling back the new pip-work on the designed bore path alignment, proper disposal of drilling fluid, and back fill of site after completion all inclusive as per IndSTT:101:2018: Code of practice of HDD Technique Suiting Indian Conditions.
200 mm dia pipe, 6mm Pipe Wall Thickness
250 mm dia pipe, 6mm Pipe Wall Thickness
300 mm dia pipe, 6mm Pipe Wall Thickness
350 mm dia pipe, 6mm Pipe Wall Thickness
400 mm dia pipe, 6mm Pipe Wall Thickness
450mm dia pipe, 8mm Pipe Wall Thickness
Provision for laying of sewer by Trenchless Technology including Supply of different size of MS Pipe, Labour T&P etc. required for Proper Completion of the Work.
500 mm (with 12 mm thick M.S. pipe cost)
600 mm (with 12 mm thick M.S. pipe cost)
700 mm (with 12 mm thick M.S. pipe cost)
800 mm (with 12 mm thick M.S. pipe cost)
Providing and erecting temporary barricading at site as per drawing/ direction of Engineer-in-Charge which includes hiring of Eucalyptus Ballies and arrangement for traffic diversion such as traffic signals during construction at site as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipment's and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). The rate is for unit length of pipe laying.
Disposal of Surplus Earth and other garbage materials etc. complete.
Diversion of Existing Sewer line during laying of New Sewer including Supply of 7.1 mm thick MS pipe size 200 mm dia and as per requirement of site condition including cost of ms pipe ms bend flange nut volt rubber packing also including hiring of DG set welding machine and gas cutter all labour material etc. complete 10% of Total Length and re- use of pipe
Dewatering work during laying of pipe line and construction of manhole
Dismantling of Existing old sewer pipe
Provision for Sand filling in trench for cuision of pipe
Provision for shifting and reinstatement of electric and telephone poles during excavation and laying of sewer lines.
Provision for shifting of electric and telephone cable, gas pipeline, existing water supply mains falling in the alignment of conveying main during excavation and the restoring utilities / services to its original condition. etc. during excavation and laying of sewer lines.
Sewer House Connection
Construction of House Connecting chambers for two connections of size 0.6 x 0.6 x 0.75m
Making Domestic Sewer connection using 110mm HDPE pipe PN-6, PE-100
Laying of Sewer line from House Connecting chambers to M.H using 160mm HDPE pipe PN-6, PE-100
Sewer inter connecting chamber to intercept the waste water from toilet, kitchen and bathroom 0.3x0.3x0.45m
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
Tender_Document_Shivala.pdf
Tender Documents • 4.05 MB
BOQ_2034773.xls
BOQ • 0.56 MB
Download all tender documents and submit your bid