| 1 | L1₹43.9 LAccepted-AOC MN SARKAR ROAD MAHANANDAPARA SILIGURI 734401 | DARJEELING | WEST BENGAL | 734401 | ₹43.9 L Quoted ₹44.3 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹45.8 L+₹1.5 L (3.49%)Rejected-Finance N A | NA | NA | 121004 | ₹45.8 L+₹1.5 L (3.49%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹46.5 L+₹2.2 L (4.88%)Rejected-Finance GEETANJALI COMPLEX B BLOCK 2ND FLOOR MUKUNDA DAS ROAD MILANPALLY SILIGURI 734405 DARJEELING | SILIGURI | DARJEELING | WB | 734405 | ₹46.5 L+₹2.2 L (4.88%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹46.5 L+₹2.2 L (4.97%)Rejected-Finance BHAKTINAGAR NJP STATION ROAD DIST JALPAIGURI WB WEST BENGAL 734007 | JALPAIGURI | WEST BENGAL | 734007 | ₹46.5 L+₹2.2 L (4.97%) | L4 | Rejected-Finance NOT LOWEST |
| 5 | L5₹46.7 L+₹2.4 L (5.35%)Rejected-Finance N A | FARIDABAD | HARYANA | 121004 | ₹46.7 L+₹2.4 L (5.35%) | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹42.4 L
EMD Value
₹84,800
Closing Date
26 Dec 2024, 6:00 pmClosed
Garrison Engineer sukna
Garrison Engineer Sukna, Post-Simulbari, Dist.-Darjeeling, WB-734009
PROVN OF SHED AT HQ 33 CORPS COMPLEX UNDER AGE BR II OF GE SUKNA AND SPL REPAIR AND REPLACEMENT OF OLD VINTAGE LT PANEL AND CONTROL SWITCH GEAR AND ALLIED WORKS AT SUKNA MIL STN
2024_MES_687432_1
GE Sukna/8734
Open Tender
Civil Works
Works
270 days
Sukna
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE Sukna
₹84,800
Yes
3 Feb 2025
7 Dec 2024
28 Dec 2024
7 Dec 2024
26 Dec 2024
20 Dec 2024
7 Dec 2024 - 26 Dec 2024
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in Soft/ Loose soil complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in Soft/ Loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed.
M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
Removing Excavated soils not exc 50 M and depositing where directed at a level not exc1.5 M above the starting point complete all as specified and directed.
M & L for Hardcore of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
M&L cement concrete 1:2:4 type B-0 (using 12.50 mm graded crushed stone aggregate) as in coping of poles,wall, top of drain and similar work etc and including necessary formwork complete all as specified and directed.
M&L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
Supply only integral water proofing compound complete all as specified.
M & L for brick work with sub class ‘B’ old size bricks straight or curved on plan n.exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for Brick work with sub-class `B' bricks, straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed.
S & F of structural steel work as in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS – 1161 – 1979 grade St – 240 including fabrication complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm TCT (total coated thickness) of any colour having tensile strength of 550 Mpa as in roof covering cladding to wall etc, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm TCT (total coated thickness) of any colour having tensile strength of 550 Mpa as in roof covering cladding to wall etc, fixed with self tapping screws complete all as specified and directed.
M&L machine cut kota stone slab 20-25 mm thick as in skirting, dado, riser of steps, plinth, etc, laid over and including 20 mm thick screed bed in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the stone complete all as specified and directed.
M&L machine cut kota stone slab 20-25 mm (minimum) thick as in skirting laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab and including rubbing and polishing and laid over 10 mm thick screed bed in CM 1:3 complete all as specified and directed.
M&L Providing 75mm thick cement concrete 1:3:6 type C-2 ( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and fair without using extra cement and providing joints throughout the thickness of the plinth protection with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
M&L 75 mm thick, PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub floor, sub base of floor, etc complete all as specified and directed.
M&L 100 mm thick, PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub base finished even and rough complete all as specified and directed.
M&L 60 mm thick machine pressed precast concrete interlocking coloured paver block of any shape and size confirming to IS 15658-2006, M-35 grade, set with grey cement and pigment including demolition complete all as specified and directed.
M&L Rendering 15 mm thick on fair faces of brick work or concrete sur-faces in cement mortar 1:4 using water proofing compound @ 3% by wt of cement for finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for preparing newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M & L for preparation of newly plastered or previously untreated surfaces of walls and applying two coats of oil bound distemper over a coat of primer and over a thin layer of wall care putty to obtain smooth finish complete all as specified and directed.
M&L preparation of new plastered wall surfaces and including applying two coats of cement base paint complete all as specified and directed.
M&L preparation of new steel surfaces of any description, not otherwise described over 10 cm width or girth and including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
E/M PORTION
M&L point wiring with 1.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) concealed in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) including modular metal flush box & modular white cover plate with frame of required module for mounting or housing switches, socket outlets, fan regulators, etc. incuding blankng plates & all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch and including cutting chasing (as required) and making good the disturbed surfaces including finishes to match with adjacent surfaces & taking down wiring & connected switch / socket / regulator bell etc. complete all as specified and directed.
All as per Sl. item No. 29.00 above but for point wiring one 5 / 6 Amps socket outlet point on independent board.
All as per Sl. item No. 29.00 above but for point wiring modular plate one 5 / 6 Amps socket outlet point on same board.
All as per Sl. item No. 29.00 above but using 2.5 sqmm PVC FRLS insulated copper conductor wire for connecting one 15 / 16 Amps socket outlet point on independent board.
M & L for sub main wiring with 2 runs of 4.0 Sqmm main wire alongwith 1 run of 4.0 Sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade copper conductor cable, drawn through and including adequate size PVC casing caping (double lock pattern) with all fittings & accessories on walls / ceiling surfaces etc., complete all as specified and directed. NOTE :- (1)Three runs of PVC wire, one run of each wire & one run of PVC rigid casing-caping will be measured as one length. (2) Cost of making good the disturbed surfaces as per existing/ original surface is deemed to be included in the unit quoted rates.
M & L concealed sub main wiring with 2 runs of 4 sqmm main wire along with 1 run of 4 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, mmaking good the disturbed surfaces including finishes to match with adjacent surfaces & taking down complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
S&F switch piano modular type one way, 5 / 6 Amps, 240 volt complete all as specified and directed.
S&F switch piano modular type one way, 15 /16 Amps independent, 240 volt complete all as specified and directed.
S&F socket outlet modular type 3 pin 5 / 6 Amps, 240 volts combined 2 modular complete all as specified and directed.
S&F socket outlet modular type 3 pin 15/16 Amps, 240 volts combined 2 modular complete all as specified and directed.
Supply and fixing vertical distribution board (DB) VTPN 4 ways, with neutral and earth bus bar 200 A rating 415 Volts, single door, MCCB 40 A TPN as incomer (will be supplied and paid separately) recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and directed.
Supply and fix 4 pole isolator 415 V, 50 Hz complete all as specified and directed.
S&F of MCB SPN 32 Amps ‘C’ series 10KA, 240 volts complete all as specified and directed.
S&F MCB SP 6 to 32 Amp, 10 kA, 240V 'C' curve including taking down complete all as specified and as directed.
S&F ceiling rose, surface bakelite 65 x 50 mm three terminal complete all as specified and directed.
S&F MCB DB, SPN 8 way, IP-43, IK 09, double door type with metal door, with 100A copper neutral and earth bus bar for fixing MCB, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed.
S&F MCCB 4P 63 Amps 415V ,50 Hz ,breaking capacity 16 KA Including taking down unsvericeable one complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanised iron strip of size 32X6 mm as earthing lead by means of nuts, bolts and washers of galvanised iron and earth lead protected by galvanised iron pipe 15 mm bore (light grade) and connected to earth test point and including cement concrete pit in PCC (1:3:6) type C-1(using 40 mm graded aggregate) and pre-cast RCC 1:2:4 type B-1, reinforced with 8 mm dia MS deformed bars 100 mm centre both ways watering arrangement with funnel and wire mesh 20 mm bore galvanised (light grade) for watering, charcoal and salt in alternate layers including necessary execuation and eath works in any types of soil complete all as shown on Electrical plate No 3 of MES SSR-I complete all as specified and directed.
S&F in repairs ceiling fan 1200 mm (minimum) sweep, BEE 5 star rated, with BLDC technology, AC single phase 230 V, 350 RPM, air delivery 220 m³/minute (minimum), with and including smart remote with long lasting batteries to control speed etc., suspended from fan hook and including electrically connecting with twisted three core PVC insulated unsheathed flexible cord of 0.75 Sqmm copper conductor from ceiling rose to ceiling fan complete all as specified and directed.
S & F in repair Surface and wall mounted LED batten 20 watt 4ft long with Aluminum extruded housing , high quality polycarbonate diffuser & integrated Electronic Driver with IP20, PF 0.95, Efficiency not less than 110 lm / W color temp 6500k CRI = 80, Operating Voltage range 140 V - 270 V complete all as specified and as directed.
M& L for on site repair of front and rear doors LT Panel of size 500mm x 500mmx500mm including welding of butt hinges 06 Nos on front side and as per requirement on back side, aldrop latches on front and rear side,spray painting with synthetic enamel paint (one coat) complete all as specified and as directed.
M& L for on site repair of front and rear doors LT Panel of size 1000mm x 800mmx500mm including welding of butt hinges 06 Nos on front side and as per requirement on back side, aldrop latches on front and rear side,spray painting with synthetic enamel paint (one coat) complete all as specified and as directed.
M& L for on site repair of front and rear doors LT Panel of size 1200mm x 800mmx500mm including welding of butt hinges 06 Nos on front side and as per requirement on back side, aldrop latches on front and rear side,spray painting with synthetic enamel paint (one coat) complete all as specified and as directed.
M& L for on site repair of front and rear doors LT Panel of size 1500mm x 1000mmx500mm including welding of butt hinges 06 Nos on front side and as per requirement on back side, aldrop latches on front and rear side,spray painting with synthetic enamel paint (one coat) complete all as specified and as directed
M& L for on site repair of front and rear doors LT Panel of size 2000mm x 1000mmx500mm including welding of butt hinges 06 Nos on front side and as per requirement on back side, aldrop latches on front and rear side,spray painting with synthetic enamel paint (one coat) complete all as specified and as directed
Dismantling & taking down the old unserviceable existing LT panel board by disconnecting existing incoming & outgoing LT cables carefully and removing from site complete all as specified and directed.
S&F 3.0 Ton tower AC floor standing type, auto start including complete accessories like inlet & outlet copper outdoor unit mounting arrangement, cordless remote control unit minimum 5 star rating complete all as specified and directed. Warranty :- (i) Comprehensive warranty - 1 Yrs (ii) Compressor warranty - 5 Yrs
Supply, installation, testing and commissioning of Panel board not less than 1.15m x 1.35 m x0.50 m , outdoor cubical type factory made (CPRI approved) ,double door , front & back both side openable type fixed with Butt Hinges and locking arrangement with Aldrop latches , fabricated of CRCA sheet , inner sheet 2.0 mm thick hinged type door for individual MCCBs and outer door 3.15 mm thick,rubberised gasket, supported on 50x 50 x 6 mm angle iron and Tee section frame dust and vermin proof complete with aluminium bus bar 4 Nos, 600 Amps rated capacity mounted on porcelain insulators totally enclosed chamber for protection 3 phase 415 volt with suitable capacity aluminium bus bar / PVC insulated copper cable control wiring duly mounted on PCC foundation with suitable size of bolts, nuts & wahsers. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complete, connecting existing cables with suitable size glands and lugs to accommodate and including the following :-
Supply, installation, testing and commissioning of Panel board not less than 2.30m x 1.80 m x 0.80 m , outdoor cubical type factory made (CPRI approved) ,double door , front & back both side openable type fixed with Butt Hinges and locking arrangement with Aldrop latches , fabricated of CRCA sheet , inner sheet 2.0 mm thick hinged type door for individual MCCBs and outer door 3.15 mm thick,rubberised gasket, supported on 50x 50 x 6 mm angle iron and Tee section frame dust and vermin proof complete with aluminium bus bar 4 Nos, 840 Amps rated capacity mounted on porcelain insulators totally enclosed chamber for protection 3 phase 415 volt with suitable capacity aluminium bus bar / PVC insulated copper cable control wiring duly mounted on PCC foundation with suitable size of bolts, nuts & wahsers. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complete, connecting existing cables with suitable size glands and lugs to accommodate and including the following :-
Supply, installation, testing and commissioning of Panel board not less than 1.70m x 1.70 m x 0.50 m , outdoor cubical type factory made (CPRI approved) ,double door , front & back both side openable type fixed with Butt Hinges and locking arrangement with Aldrop latches , fabricated of CRCA sheet , inner sheet 2.0 mm thick hinged type door for individual MCCBs and outer door 3.15 mm thick,rubberised gasket, supported on 50x 50 x 6 mm angle iron and Tee section frame dust and vermin proof complete with aluminium bus bar 4 Nos, 400 Amps rated capacity mounted on porcelain insulators totally enclosed chamber for protection 3 phase 415 volt with suitable capacity aluminium bus bar / PVC insulated copper cable control wiring duly mounted on PCC foundation with suitable size of bolts, nuts & wahsers. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complete, connecting existing cables with suitable size glands and lugs to accommodate and including the following :-
Supply, installation, testing and commissioning of Panel board not less than 1.35m x 1.20 m x 0.50 m , outdoor cubical type factory made (CPRI approved) ,double door , front & back both side openable type fixed with Butt Hinges and locking arrangement with Aldrop latches , fabricated of CRCA sheet , inner sheet 2.0 mm thick hinged type door for individual MCCBs and outer door 3.15 mm thick,rubberised gasket, supported on 50x 50 x 6 mm angle iron and Tee section frame dust and vermin proof complete with aluminium bus bar 4 Nos, 600 Amps rated capacity mounted on porcelain insulators totally enclosed chamber for protection 3 phase 415 volt with suitable capacity aluminium bus bar / PVC insulated copper cable control wiring duly mounted on PCC foundation with suitable size of bolts, nuts & wahsers. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complete, connecting existing cables with suitable size glands and lugs to accommodate and including the following :-
M/S GLORIOUS CONSTRUCTION (BID ID -3199092)
R K UDYOG (BID ID -3198514)
M/S ASHRAFI CONSTRUCTION (BID ID -3198376)
M/S TANDRA DEY. (BID ID -3197882)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .