Superintending Engineer
Office of the Superintending Engineer, PWD., Building Construction and Maintenance Circle, Thanjavur 1
Provision of Internal and External Electrification to the Cemonc building at Government Hospital Pattukkottai in Thanjavur District
2023_PWD_380600_1
13-01-2023-2024/SE/BCMC/TNJ
Open Tender
Civil Works - Buildings
Lump-sum
180 days
Pattukkottai
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹56,000
31 Jan 2024
19 Oct 2023
3 Nov 2023
19 Oct 2023
2 Nov 2023
19 Oct 2023
Amount
Wiring with 2x1.5sqmm (22/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with GI flush mounting box (GI) with white cover plate with frame (Plastic) and 6A 1way SP 1module switch and making good of the concealed portion with suitable colour for PVC concealed light / Fan Point (For electronic regulator) (Higher End)(5 Points Per Coil)
Wiring with 2x1.5sqmm (22/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 1 module GI flush mounting box with white cover plate with frame (Plastic) with 1 module flush mounting box (GI) and 6A 1way SP 1module switch and making good of the concealed portion with suitable colour for PVC concealed light (Higher End ) (6 Points Per Coil) (For Rooms like Bath, Toilet & Pump room etc.)
Supply and fixing of battern holder with 9 W LED lamp for BH point.
Supply and fixing of Single box type 4'20 W LED fitting with TW round blocks on wall or ceiling with 20W LED tube with PVC unsheathed Copper leads from terminal to the fitting.
Supply and fixing of single box type 4'20W LED fitting with LED tube (Higher End ) with conduit pipe suspension from the ceiling with PVC unsheathed Copper leads from terminals to the fitting.
Supply and fixing of 1x1 30 W LED Recessed square type mounting fitting complete with LED Driver with PVC unsheathed Copper leads from the terminals to the fittings .
Supply and fixing of WT bulk head fitting with guard suitable for 9W LED lamp with LED. [Lift Well)
supply and fixing of 1200mm (48") sweep AC ceiling fan complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18")
Supply and fixing of 300 mm (12") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall
Supply and fixing of louvers shutters arrangements for 300 mm (12") sweep (light duty) AC exhaust fan.
supply and fixing of 30W LED street light fitting with LED (Higher end) with 25 mm dia. GI pipe (class B) with 1 no. 25 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting .
Supply and fixing of 3nos.6A two module 5 pin socket , 3 nos. 6A one module switch with module cover plate(plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Supply and fixing of 2Nos. 6A 5 pin universal socket 2 module with 6A 1way SP 1module switch & 1Nos. 16A 5 pin universal socket 2 module with 16A 1way SP 1module switch concealed in suitable 9 module flush mounting box (GI) in flush with wall and concealed with 9 module white cover plate with frame (Plastic) (Higher End Crabtree/ Legrand/Hager make) with earth connection.
Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End.(SD-488)
Supply and fixing of 20Amps DP Plug and Socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For AC Plug) [Legrand (MDS) / Hager (L&T) make]
Supply and run of 2 of 2.5 sqmm (36/0.3) PVC insulated SC unsheathed Cu. conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour
Supply and run of 2 of 4 sqmm (56/0.3) PVC insulated SC unsheathed Cu. conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour.
Supply and run of 4 of 4 sqmm (56/0.3) PVC insulated SC unsheathed Cu. conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour.
Supply and run of 4 of 6 sqmm (84/0.3) PVC insulated SC unsheathed Cu. conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour.
Supply and run of 4 of 10 sqmm (84/0.3) PVC insulated SC unsheathed Cu. conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour.
Supply and fixing of 12 way single pole and neutral MCB DB with metal door cover with IP 42 protection with 1No. 32 Amps DP MCB as incoming and 10 Nos. 6 Amps to 32 Amps SP MCB outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB's should be with ISI mark (Legrand (MDS)/Hager (L&T) make)
Supply and fixing of Triple Pole 4 way Vertical type MCB DB in metal double door with IP 42 protection in sheet steel enclosure Distribution board with 1No 63 Amps FP MCB isolator as incoming , 12 nos of 6 to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB's should be with ISI mark (Make Legrand/ L &T make).
Supply and fixing of Triple Pole 4 way Vertical type MCB DB in metal double door with IP 42 protection in sheet steel enclosure Distribution board with 1No 100 Amps FP MCB isolator as incoming , 1 no 63 A TP MCB and 9 nos. 32A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB's should be with ISI mark (Make Legrand/ L &T make).
Supply and fixing of 8 way Vertical Triple pole and neutral MCCB sheet steel enclosure distribution board ( with MCCB Incomer ) with double door (metal door) with 1 no. 160 A 4 P MCCB switch as incoming and 6 nos.63A 3P MCB , 6 nos. 6A -32A SP MCB as outgoing with suitable cable end box on wall with earth connection only. Higher End.
Supply and fixing of 32A TPN MC switch with suitable angle iron frame work with MS cable entry boxes with earth connection only.(SD-164)
Supply and fixing of 63A TPN MC switch with suitable angle iron frame work with MS cable entry boxes with earth connection only.(SD-166)
Supply and run of 4 of 16 sqmm (101/0.45) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour. (DATA-8)
Supply and erection, testing and commissioning of 2.0 TR (6000 W/HR) split type 3 star rated AC units fitted with rotary sealed compressor operation on refrigerant Non CFL gas suitable for floor mounting, wall mounting, celling mounting confirming to IS 1391(para 2)/92(except power consumption norms)Suitable for operation of 230V,50Hz,single phase ac supply with capable of performing
(I) cooling (II)dehumidifying. (III)Air circulating. (IV)Filtering.
The installation works for the split type AC unit includes the following 1.Mounting/fixing indoor and outdoor units at the respective locations. 2.Laying refrigerant pipe line of required length not exceeding 6 mtrs distances and connecting both units after drilling holes in the wall if required. Thickness of the copper tube shall not be less than 0.7 mm.
3.Insulating the section pipe with expanded Polyethylene frame 5 mm tubing. 4.Laying 15 mm dia flexible PVC drain pipe to condemn ate water being formed with in the indoor unit.
5.Leakage testing the entire system. 6.Charging refrigerant gas in the unit. 7.Suitable electrical wiring to be provided with 2.5 Sq.m.m PVC Insulated copper wire between indoor & outdoor unit type 6 mtr. Length and upto switch with in the 3 mtrs of location of indoor unit. (Blue Star,Carrier,Voltas) (3 star Rated) (SR) .
Supply and fixing of 5 KVA Electronic automatic Voltage stabilizer ‘ V ’ Guard make VGS 500 ( or ) Equivalent with input range of 170V to 270V and output range of 200V – 240V unit with and low voltage cut off and 3Mintes time delay with demonstration complete.(SR )
Supply and laying of Copper tubes of 3/8" and 5/8" with neccesary foam and packing Tape insulation.(SR)
Supply and fixing of M.S Stand for A.C out door Unit.(SR)
Supply and fixing of brass cable gland for 3½ x 185 sqmm PVC armoured LTUG cable with earth connection [SD-193]
Supply and clamping of 3 ½ x 185 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps.[SD-229]
Supply and providing cable end termination of 3 ½ x 185 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete
Supply and fixing of brass cable gland for 3½ x 35 sqmm PVC armoured LTUG cable with earth connection
Supply and clamping of 3 ½ x 35 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps.
Supply and providing cable end termination of 3½ x 35 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete .
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection.
Earthing as per the ISI specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry .
Supply and fixing of 200 A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with PWD earthing.
Supply and fixing of 5A / 15A 3 pin combined flush type wall socket with 15A flush type switch on suitable TW Box
Supply and run of 2 of 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour
Design, Engineering, supply, fabrication. Erection, Testing commissioning and handing over of 1 No 26 Persons Bed Cum Passenger Lift (Gearless Lift with Machine Room) as per the following Technical Specification. 1.Type of Lift : Bed Cum Passenger Lift2. Capacity of Lift : 26 Persons/1020 Kgs 3. Speed : 1.00 Meter/Sec 4. Type of Drive: specific Variable Voltage Variable Frequency V3F Drive with Enhanced ride comfort and levelling functions. 5. No. of Floors : 4 (Ground Floor + 3 upper floor)6. Total Travel : 40 feet 7. Levelling Accuracy: High Level Accuracy with Smooth and jerk free stopping. 8. Construction of Car: High quality and suitable thickness S.S. car and M.S false ceiling. 9. Position of Machine: Directly above the Lift shaft. 10. No. of Landing Entrance : 4 (Ground +3)11. No. of car Entrance: One in Front only.12. Car Entrance Door: Power Operated V3F drive side Opening Sliding S.S Doors with VF operation.13. Landing Entrance Door: Power Operated V3F driver Side Opening S.S Doors with provision emergency key opening at all Landings. 14. Lift Well Existing: 2300 mm (width) X 3000 mm (depth). 15. Lift Pit Depth required: 1600 mm 16. Car Size: 1000 mm (Width) X 2400 mm (Depth). 17. Car Clear Opening: 800 mm 18. Power Supply: 400 / 440 V, 3 Phase, 50Cycles / Sec AC supply for power and 230V 50HZ single phase AC Supply for light at machine room with proper two distinct earth flat of adequate size from ISI earthing at ground floor.19. Control: Microcomputer (Microprocessor) based Simplex, Collective control with or without attendant.20. Car Fittings: Compact Fluorescent Lighting with 2 Nos. 300 mm Sweep Cabin Fan.21. Lift Well: R.C.C Construction with Brick Masonry.22. Indication: UP/DOWN Digital Direction and position indicator for all landing and inside the car.23. Emergency Alarm Bell: Battery Operated alarm bell with Automatic Charging Device. 24. Emergency Light: Battery operated Light with Automatic Charging Device.25. Fire Man’s Switch: Include at Ground Floor.26. Scaffolding: Included.27. M.S. Sill angels and facis Plates: Included 28. Steel for Lift Machinery: Included 29. Servicing and maintenance: Free comprehensive servicing and maintenance during the guarantee period of one year.
30. Automatic Rescue Device: To facilitate the landing of the lift to the nearest floor at the time of Power Failure. This shall consists of suitable type of Battery system with charger, invertor, under Voltage Protection system etc., Complete with all Accessories.31. Provision of Intercom with phone: Included32. Lift Licence: Preparation of Drawing, payment of Charges to CEIG / Lift inspectorate and insurance policies if any and obtaining CEIG safety certificate as per Lift Act.33. Floor Annunciator with music: Included. 34. SPECIAL FEATURE:A.) Infra-Red colour Sensor with Height Screen.B.) Stainless steel signal fixtures. C.) Vandal Proof Button with S.S Cover. D.) S.S door frames for landing doors.E.) VF Door operator.F.) Calls register Signal.G.) Stainless Steel Facia plate for car operating Panel and landing fixtures.H.) ON-OFF Switch for fan and Light. .) Voice Annunciator. 35. Lift Duty motor of adequate capacity reduction worm gear, electromagnetic brake with compression springs, over speed Governor, Phase failure and phase reversal relay, alarm Bell, T Guide Brackets for car and Counter weight, Rubber padding under winding unit, car safety Gears, Buffer, Electro Mechanical Door Locks, Emergency Key, Side supporting angles motor Over Load Protection Devices. Final limit Switch, main suspension ropes, Counter weights, Lifting Joist for Mounting the Machineries.36. Site testing in accordance with IS 14556 should be carried out at the time of handing over. 37. Further Comprehensive servicing and Maintenance of Lift for further period of 1 Year from the date of commissioning of lifts . (JOHNSON/OTIS/KONE ONLY)
ADD GST 178%
VASANTH ELECTRICALS
T VEERBATHIRAN
JAI GANESH ELECTRIC ENGINEERING
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .