Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC | L1 | Accepted-AOC Awarded Being Lowest Bidder | |
| 2 | L2₹33.1 L+₹4.1 L (14.1%)Rejected-AOC PLOT NO 8 PREMA APARTMENT VEDANTNAGAR CHHATRAPATI SAMBHAJINAGAR 431 007 M S | CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | 431007 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹34.8 L+₹5.8 L (20.2%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹35.1 L+₹6.2 L (21.2%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹36.9 L+₹7.9 L (27.4%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
3 Jan 2022, 6:00 pmClosed
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Repair to internal wiring and repair / replacement of DBs/MCBs/MCCBs /Submain wiring and connected work of New KLP MH EME Workshop / HQ SOTT AND MES Staff Qtrs under GE(N) Ahmednagar
2021_MES_492860_1
8582 / E2
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Ca b(i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹82,000
Yes
8 Jan 2022
7 Dec 2021
5 Jan 2022
7 Dec 2021
3 Jan 2022
21 Dec 2021
Amount
Taking down carefully copper/aluminum point wiring (light/fan/bell/socket, power point etc) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors etc complete all as specified and directed Engineer-in-Chage
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of PVC boxes and fixed with brass screws cup washer for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth & connecting to earth dolly for the following, etc complete all as specified and directed Engineer-in-Chage Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, bulkhead lights, bldg security light etc
One light point controlled by switch 5 Amp single pole one way
One fan point controlled by switch 5 Amp single pole one way
One bell point controlled by switch 5 Amp single pole one way on independent board
One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch
One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board
One light point controlled by switch 5 Amp single pole two way
All as per Item No 2 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase, Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board etc complete all as specified and directed Engineer-in-Chage
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn in and incl PVC Casing and capping ISI Marked with its accessories PVC boxes (upto 18 module suitble for Mylinc series of Legrand including white plates with frame upto 18 module of make suitable for Mylinc Series ) for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth & connecting to earth dolly for the following, etc complete all as specified and directed Engineer-in-Chage Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2.Wiring shall be done as per complaints recd from user only on required basis it is not necessary to do whole wiring of any whole bldg 3. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, ceiling lights, bulkhead lights, bldg security light etc
One light point controlled by switch 5 Amp single pole one way
One fan point controlled by switch 5 Amp single pole one way
One bell point controlled by one switch 5 Amp single pole, one way on independent board
One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch
One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board
One light point controlled by switch 5 Amp single pole two way
All as per Item No10 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase , Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board
S&F switch piano flush type single pole, one way 5/6 Amp etc complete all as specified and directed by Engineer-in-Charge
S&F switch piano flush type single pole, two way 5/6 Amp etc complete all as specified and directed by Engineer-in-Charge
S&F Switch socket combination two in one, 5 Amp flush type 230V AC etc complete all as specified and directed by Engineer-in-Charge
S&F Switch socket combination 5 Amp / 16Amp, five in one, 5 / 15 Amp 230V AC etc complete all as specified and directed by Engineer-in-Charge
S&F bell push piano flush, single pole, one way 5/6 Amp etc complete all as specified and directed by Engineer-in-Charge
S&F bell ding dong elelctric 230V AC single pole etc complete all as specified and directed by Engineer-in-Charge
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required etc complete all as specified and directed by Engineer-in-Charge.
S & F electronic dimmers,as per existing wattage, 250V flush type on the exiting phenolic laminated sheet etc. as required etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Switch, 6 Amp, one way, one Module. etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Switch, 6 Amp, two way, one Module. etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Switch, 16 Amp, onw way, one Module. etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Socket Outlet 6 Amp, 2/3 pin, combined two module etc complete all as specified and directed by Engineer-in-Charge.
S&F Modular Socket Outlet 6 Amp / 16 Amp - 2/3 pin combined two module etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Bell push, 6 Amp, one module etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Fan Regulator Fan step regulator, 120 Watt - two module etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified and directed by Engineer-in-Charge
M&L ceiling rose 3 terminal / PVC / polycarbonate, isolated body etc complete all as specified and directed by Engineer-in-Charge
Fixing only double door Sheet metal enclosures factory made Concealed in wall VT DBs 4 way TPN, 415 volts etc complete all as specified and directed Engineer-in-Chage
Fixing only double door Sheet metal enclosures factory made DBs SPN, 8 way ,240 volts etc complete all as specified and directed Engineer-in-Chage.
Fixing only double door Sheet metal enclosures factory made DBs 4 way SPN, 240 volts ,protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. Make: Legrand ,Cat No:5076 10 or equivalent in Simens/ Hager/ L&T
Fixing only MCB , SP, AC, 240 Volts of 06 to 40 Amp capacity 16KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Fixing only MCBs, TPN, AC, 415 volts of 63 Amps capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Fixing Only MCBs, SPN, AC, 240 volts of 40 Amps capacity 16KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Fixing Only MCBs, SPN, AC, 240 volts of 63 Amps capacity 16KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Fixing Only MCCBs, Four pole of 63 Amps capacity 25 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Fixing Only MCCBs,Four pole, 415 volts of 100 Amps capacity 25 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Fixing only Slim line advance square profile LED lighting and including its connection with 2 core seathed copper conductor cable of size 0.5 Sqmm with etc complete all as specified and directed Engineer-in-Chage
Fixing only 36 Watt LED Panel 2X2 with and including connecting up with & including twin core, twisted, flexible copper conductor cable of suitable size 230 Volt, 50 HZ etc complete all as specified and directed by Engineer-in-Charge.
Fixing only energy saving and environmental friendly long life LED street light 25 Watt (Bldg security light) fixed on wall with and including GI pipe of suitable dia and all fixing accessories including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230V , 50 HZ etc complete all as specified and directed by Engineer-in-Charge Note for Sl item Nos 35 to 46 : DB, MCB. MCCB & LED fittings shall be issued under Schedule `B' free for fixing
Supply & fix replacemnt industrial type switch socket for Geysers with 20 Amp MCB etc complete all as specified and directed by Engineer-in-Charge
S&F sub main wiring with two single core PVC insulated,unsheathed, FRLS stranded copper conductor cable 6 Sqmm with 6 Sqmm PVC insulated, unsheathed, FRLS stranded copper conductor cable as earth wire drawn through and including PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. Two run of 6 Sqmm cable i.e for one run for phase, one run for neutral with one run of 6 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit
S&F sub main wiring with two single core PVC insulated,unsheathed, FRLS stranded copper conductor cable 4 Sqmm with 4 Sqmm PVC insulated, unsheathed, FRLS stranded copper conductor cable as earth wire drawn through and including PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note : 1. Porper colour coding must be utilize for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. Two run of 4 sq.mm cable i.e for one run for phase, one run for neutral with one run of 4 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25 m depth and top edge of the earth plate not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts & washer etc. Earth wire connected upto main earth point / DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 using granded stone aggregate and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of TMT bar @ 100 mm CIC, both way, lifting arrangement complete including all necessary earth work etc complete all as specified and directed by Engineer-in-Charge
S&F LED Driver suitable for 36 Watt,2x2 LED Panel ceiling lightComplete all as directedby Engineer -in-Charge.Make Havells/Crompton/Wipro
S&F Sheet metal enclosure two way Suitable for fixing MCBs Complete all as directedby Engineer -in-Charge.Make Havells/Crompton/Wipro
Supply and laying or fixing or passing in trenches/ on pole / through pipes, 1100 volts grade XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor of cross sectional area 25 sq mm 3.5 core including connection with cable glands & lugs etc and testing on completion etc complete all as specified and directed by Engineer-in-Charge.
Supply & laying in repair galvanized steel tubing "light grade" with all fittings in trenches/ under roads/ along pole/ wall for cable protection etc complete all as specified and directed by Engineer-in-Charge. for the following size. Note :- Excavation and earth work shall be measured & paid separately under relevant item of this BOQ) . .
50mm bore
Excavation in trenches not exceeding 1.5 metre wide & not exceeding 1.5 meter in depth for foundation, laying of cable or pipe and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engr-in-charge.
Returning, filling in trenches in soft/loose soil in layers n.exc. 25 cm after laying of cables including spreading, levelling, wtering, and well ramming complete all as directed by Engr-in-Chrage.
Removing surplus excavated soil to a distance n.exc. 50 metre and depositing where directed at a level n.exc.1.5 metre high from the starting point all as directed by Engr-in-Chrage.
Supply &lay HDPE pipe 63 mm bore for laying of LT cable complete with all accessores specified and directed.by Engineer in Charge.
Taking out old PVC/Wooden/metal switch board ,wire connection from the wall and fix new PVC Cutting sheet board box including connecting wire suitable for fixing switch/Socket/fan regulater of following sizes .(Note.Damaged Switch/Socket/regulator will be measured and paid Sepereately)
(a) 4x4 inches
(b) 4x6 inches
(c) 6x8 inches
(d) 8x10 inches
(e)10x12 inches
An amount of Rs 1,51,291.00 shall be deducted from BOQ on account of schedule of credit
ASHWAMEDH ENGINEERS
M/s. N D Karande
Ms. S.K. ASSOCIATES
BHAVIN INFRA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .