Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹45.2 L+₹5.1 L (12.7%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹45.8 L+₹5.7 L (14.2%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
2 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS Rajouri
SPECIAL REPAIR TO BLDG NO T-29, T-41, INCLUDING SPECIAL REPAIR TO LT PANEL AND DEFECTIVE OH LT LINES AND CERTAIN MINOR WORKS UNDER AGE BR DETT-A AND AGE EM OF GE 862 EWS
2024_MES_670690_1
GER-53/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS Rajouri
As per Tender documents
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹94,000
Yes
18 Nov 2024
3 Sept 2024
4 Oct 2024
3 Sept 2024
2 Oct 2024
18 Sept 2024
3 Sept 2024 - 14 Sept 2024
Amount
Sch 'A' Part-I (B/R works) Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness below or above the ground level, complete all as specified and directed.
M&L for Machine cut kota stone slab (mirror polished) flooring 18-20mm thick as in floors and jointed with grey cement slurry mixed with pigment to match the shade of the slab including machine cutting to make it square or rectangular, rubbing and cutting and polishing to achieve mirror finish, laid over and including screed bed or bedding layer of 15 mm thick in cement mortar 1:4 including taking down old kota stone, complete all as specified and directed.
M&L for 75mm thick plain cement concrete, type C-1, 1:3:6 (using 20mm graded crushed stone aggregate) as in plinth protection, laid in slope 1:12 from outer edge of the wall, finished even and fair, laid in alternate bays including providing 6mm wide joints throughtout thickness of plinth protection in concrete bays and in between walling and plinth protection, joints filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand (all by weight), complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frames) n.exc 1.5 Sqm each, complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frames) exc 1.5 Sqm but n. exc 4.0 Sqm each, complete all as specified and directed.
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and directed.
M&L for stone walling of random rubble masonry, uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar 1:6, complete all as specified and directed.
Description all as per srl item No. 7.00 above but except stone. NOTE: Old stone retrieved from demolition shall be used.
M&L for brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6, complete all as specified and directed.
S&F for 4mm thick designer ceiling board in ceiling fixed with screw as per manufacturers instructions, laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet of size 24 x 32 x 300 mm spaced at 1200 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug or hanged with existing truss members. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modules cross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per insturctions including dismantling of existing board etc, complete all as specified and directed.
Dismantling of timber scantling 40 Sqcm and over in section, in any position as in unframed or framed work as in purlin and rafter, complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
S&F for roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy brackets framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats, etc. conforming to Fe-410-W (Gde - E-250) quality A complete all as specified and directed.
Description all as per Srl item no 13.00 above but fixing. Note:- Mild steel obtained from Srl item no 12.00 shall be re-use.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nanital or similar pattern roof coverings, complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions, complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based plain sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in ridges, hips, valley gutters fixed with self tapping screws including side and end lap as per manufacturer’s instructions, complete all as specified and directed.
Taking down cement plaster, any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 20 mm thick in cement mortar 1:6 on stone masonry surface (internal surface), finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 20 mm thick in cement mortar 1:4 on stone masonry surface (external surface), finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for reinforced cement concrete 1:2:4, B-1 (Nominal Mix) (20mm graded crushed stone aggregate) as beams, lintel beams and columns in floors, roofs, landings, balconies,canopies, deck slabs, chajjas and in shelves and the like, including demolition of old RCC work in any position and any description, complete all as specified and directed
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilivers, shelves, including sup-ports, overhangs etc also splays between floors and beam etc, complete all as specified and directed.
S&F for pressed steel door frame of size 125x60 mm with one or more rebates including necessary fixing lugs, hinges, lock and strike plate etc including back filling to chowkhats in PCC 1:3:6 type C-1 using 20mm graded stone agregate complete all as specified and directed.
S & F for 35mm thick 2nd class hardwood, plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers complete all as specified.
S&F for flush shutter solid core construction with block board core and plywood face panels, commercial type on both sides 35mm thick and covered on both sides with decorative face veneer with lapping / frame to match, complete all as specified and directed.
S&F for factory made 35 mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed.
S&F for factory made MS tubular Box type window (double rebate and double shutter) of MS rolled steel section conforming to IS-1038 and shall be ISI marked manufactured by ISI approved manufacturer, openable frames shall be fabricated of sections as approved by Engr-in-Charge, corner welded to form a solid fused welded joint, handles shall be of Z section welded with openable frame box steel section used in outer frame, shutter frame and central frame shall be ERW secton of 16 gauge with fixing lugs to be fixed as per provision of IS-1038 except that top lugs shall not be provided , all shutters of windows shall be provided with 4 Nos friction free hinges, 2 Nos 75 mm tower bolts to each leaf of window one at top and one at bottom welded on 3 mm thick steel sheet piece of suitable size which shall be in turn welded to Z section of steel window to provide suitable arrangement of using tower bolt. Glazed, gauzed window , mild steel casement stays 300 mm with hinged joint and two plates with studs complete all as specified with all fittings and fixtures without glazing bars including 3mm thick sheet glass ordinary quality and GI wire mesh of 0.56mm nominal dia and average width of aperture 1.18 mm etc, complete all as specified and directed.
S&F of mild steel guard bars/ grills as specified in between glazed and fly proof window shutters (sand witching guard bars / grill) as per applicable TD drawing, complete all as specified and directed.
S&F of 2nd class hardwood small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles n exc 200 cu. cm each, complete all as specified and directed.
M&L for plain cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) as in bed blocks, bed block for hold fast, coping, benching, haunching around manhole,water troughs, PCC cill, lintels of span upto 1.5m, bed block for fencing post and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work ,complete all as specified and directed.
S&F for extruded aluminium alloy handles size 150 mm fabricated type anodised (ISI marked), complete all as specified and directed.
S&F for aluminium anodized barrel tower bolts 200 mm long of extruded section (ISI marked) ,complete all as specified and directed.
S & F of 300 mm long (Length of bolt) aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolt of extruded sections or cast aluminium alloy (ISI marked), complete all as specified and directed.
M&L for 300mm MS ordinary rat tail rod pattern door springs (ISI marked) of approved make including roller and roller plate, complete all as specified and directed.
S& F for galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperature 1.14mm and fixed with tinned tacks, or galvinsed wire staples , complete all as specified and directed.
M&L for preparation of new steel surface exc 10 cm width or girth and applying two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed by Engr-in-Chagre.
M&L for preparation of new wooden surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint over a coat of primer, complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of 1.5mm thick wall care putty, complete all as specified and directed.
M&L for preparation of old decorated brick / concrete plastered/ un-plastered surfaces of walls, pillars, cornices etc by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and applying two coat of oil emulsion distemper over a coat of primer including one coat of wall care putty 1.5mm thick, complete all as specified and directed.
M&L for preparation of old decorated brick / concrete plastered / un-plastered surfaces of walls, pillars, cornices etc by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of cement base paint , complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair/other than faces of brick wall or concrete work, finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for prepolished coloured chequered cement concrete tiles of size 30 cm x 30cm x 25 mm thick set, jointed in neat cement slurry in floor and pointed in white or coloured cement to match the shade of tiles laid over and including 15 mm thick screed bed in cement mortar 1:4 including demolition of old tile, complete all as specified and as directed.
M&L for 75mm thick plain cement concrete 1:4:8, type D-2 using 40mm graded crushed stone aggregates as in sub base of floor, complete all as specified and directed.
M&L for plain cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregates as in surface channel and drains, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish off the premises complete all as specified and directed.
M&L for 25mm thick plain cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregates as in sub base of floor to receive tile, complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (premium quality) Square/rectangular, area of each tile exceeding 0.06 sqm but n.exc 0.11 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
M&L for glazed ceramic coloured tiles of size 350x250x7mm / 450x350x7mm thick, (premium quality) on vertical surface of wall such as dado, skirting, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 10mm thick screed bed in cement mortar 1:4, complete all as specified and as directed.
M&L for vitrified tiles light shade, coloured (premium quality) 10 mm thick (square/ rectangular) polished, area of each tiles n. exc 0.36 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, laid over and including 15 mm thick screed bed in cement mortar 1:4, complete all as specified and directed.
All as per srl item no 51.00 here-in-before but in skirting including 10 mm thick rendering in cement mortar 1:4, complete all as specified and directed.
M&L for 15 mm bore GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors, including taking down old GI tubing 15mm bore and connection including cleaning for refixing or removal to store, complete all as specifed and directed.
M&L for 20 mm bore GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors after taking down GI tubing 20 mm bore and connections, complete all as specifed and directed.
Fixing only 15 mm bore old GI tubing with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors, complete all as specifed and directed.
S&F in repair for 15mm bore bib tap cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair for ball valves suitable for 20mm bore iron pipe high pressure of PTMT with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) complete all as specified and directed by Engr-in-Charge.
S&F in repair for 15mm bore Stop valve/ Angle valve, cast copper alloy screwed down, high pressure with crutch or butterfly handle, chromium plated, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F as in repair for viterous China water closet pedestal pattern in one piece type of dimention 73cmX36cm74cm including seat cover and gaset, floor mounted, 'P' or 'S' trap, flushing kit, CP jet with PVC pipe of superior quality and all necessary fixing arrangements, complete all as specified and as directed.
S&F in repair for PVC connection 15 mm x 450 mm including brass nuts at both ends screwed for iron pipe of 15 mm bore, complete all as specified and directed.
S&F in repair for 20mm bore Stop valve, cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement and connecting to waste pipe, complete all as specifed and directed.
M&L in repair for 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall with MS clamps or laid in floor/trenches, complete all as specified and directed.
M&L in repair for 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall with MS clamps or laid in floor/trenches, complete all as specified and directed.
S&F in repair for chromium plated brass shower rose of size 125 mm with swivel joints fixing to steel pipes etc. Complete all as specified and directed.
S&F in repair for brass chromium plated tubular towel rail 20 mm dia "D" type 60 cm long between flange, aluminium anodised complete all as specifed and directed.
S&F in repair for vitreous China wash basin, white, flat back, size 550x 400mm excluding taps, waste chain and plug and pocelan stopper but including cutting for pinning in ends of brackets including 32mm bore waste fittings brass CP with long screwed shank and flu nut and PVC waste pipe 32mm dia 850mm long including CP WHB mixer for Hot & cold water 15mm dia, complete all as specified and directed.
S&F in repair for stainless steel grating 100mm dia, complete all as specifed and directed.
S&F in repair for stainless steel toilet paper holder with flat recessed type, fixed to wall with steel screws, complete all as specified and directed.
S&F in repair for sheet glass shelf assembly consisting 5.5 mm thick, sheet glass shelf 12cm wide with chromium plated bracket guard and rainling 60cm long, complete all as specified and directed.
S&F in repair 15mm CP brass health faucet (hand shower) inlet length 100mm fixed to angle valve with and including decorative choice flexible pipe, wall hanger etc, complete all as speicified and directed.
S&F in repair for curtain rod (drapery rod) of wooden finishes of 25mm dia fancy type complete and hanging hooks / bracket/ end cap of length 1.5m to 1.8m, complete all as specified and directed.
S&F in repair for 15 mm bore brass chromium plated wall mixer hot & cold water screwed down for iron pipe and fixed, complete all as specified and directed.
S&F for rotational moulded polythylene water storage tank (ISI marked) with float valve, plastic lid cover, double-layered, cylindrical vertical with closed top, hoisted and fixed in position of capacity 1000 ltrs tank and making connections inlcuding suitable GI wash out, over flow, nipple and including 20mm bore ball brass valve with union screwed for iron pipe and fixed including dismantling of old water tank, complete all as specifed and directed. Note:- The water tank shall have embossed ISI marked with IS no. and weight of tank shall be as per IS standard.
M&L for Anodised aluminium frame for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F for anodised aluminium (minimum thickness of power coating 50 micron) door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, mortice lock, 1 No floor door stopper, anodised aluminium snap beading, screws etc. complete all as specified and directed.
M&L for 12mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to aluminium frame work, complete all as specified and directed.
M&L for sheet glass 5.5 mm thick, ordinary quality and fixed with aluminum & rubber beading in square exc 0.5 sqm in each pane, complete all as specified and directed.
M&L for complete removal of existing treatment of walls and applying two coats of cement base paint after preparation of surface, complete all as specified and directed.
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m in depth in any type of soil, for foundation, etc, or for shafts, wells, drain, pipes, laying of cable/pipes, foundation of poles/stays etc n.exc 10 Sqm on plan and getting out, complete, all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick ,complete all as specified and as directed.
Removing excavated material ,not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting poin, complete all as specified and directed.
M&L for plain cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregates) as in foundation, filling and mass concrete, complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4, complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of premium acrylic smooth exterior paint with silicon additives of required shade over and including a coat of primer, complete all as specified and directed.
M&L for construction of septic tank with cover slab of RCC M-25 of capacity 50 users including brick work in cement mortar 1:4 (with top of slab at ground elevated including necessary fitting, RCC manhole cover with angle iron welded frame including excavation in any type of soil, PCC 1:4:8, type D-2 in foundation, vent shaft, connection etc including returning filling of soil, well ramming in layers and removing excavated surplus soil to a distance not exc 50m, complete with permanent specification and all as shown on drawing no CE/TD/1202/2003 SH 1/2 & 2/2. and as directed by Engr-in-Charge at site.
M&L for construction of soakage well 3.0 m dia and 4.5 m deep including excavation and earth work in any type of soil, PCC 1:4:8, type D-2 in foundation, walls of honey combed masonry with top ring of M-25 concrete including intercerpting chamber and screen chamber made of brick masonry in cement mortar 1:4, RCC cover slab in M-25 (Design mix), interconnecting pipes of RCC, complete filled with brick bats complete all as specified and shown on drawing No CE/TD 1202/2008 SH 1/2 & 2/2 and as directed at site by Engr-in-Charge.
M&L for construction of soakage well 3.0 m dia and 3.0 m deep including excavation and earth work in any type of soil, PCC 1:4:8, type D-2 in foundation, walls of honey combed masonry with top ring of M-25 concrete including intercerpting chamber and screen chamber made of brick masonry in cement mortar 1:4, RCC cover slab in M-25 (Design mix), interconnecting pipes of RCC, complete filled with brick bats complete all as specified and shown on drawing No CE/TD 1202/2008 SH 1/2 & 2/2 and as directed at site by Engr-in-Charge.
M&L for plain cement concrete 1:3:6, type C-2 (using 40 mm graded crushed stone aggregates) as in foundation, filling and mass concrete, complete all as specified and directed.
M&L for plain cement concrete 1:3:6, type C-2 ,using 40 mm graded stone aggregate, as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150 mm bore SGSW pipe, complete all as specified and directed.
M&L for 150 mm internal dia Salt-Glazed stone ware drain pipes grade 'A' laid in trenches over concrete bedding jointed in cement mortar (1:1) and tested ,complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash, complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc, complete all as specified and directed.
M&L for providing pre-cast cement concrete landing cover slabs (for man holes etc) chullah hoods, chajjas, water troughs, mangers, shelves and similar items with plain faces in cement concrete 1:2:4 type B-1 using 20mm grading stone aggregate and setting in cement morter 1:6, complete all as specified and directed
M&L for mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as in stirrups, spacers and binders including binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Supply only integral water proofing compound, complete all as specified and directed.
M&L preparation old painted steel surface of any descrtiption n. exc 10 cm in width or girth surfaces and apply one coat of synthetic enamel paint, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, straight or curved including work in arches/ ornamental and vault with purpose moulds or faircut and rubbed bricks and joints of uniform thickness and plan exc 6m mean radius, built in cement mortar 1:4 etc, complete all as specified and directed. Note:- No extra cost shall be claimed by contractor in respect of cutting bricks or wasted due to ornamental works as direct at site.
S&F stain less steel peg set with min 06 nos of hooks mounted over 4mm thick stainless steel plate with and incl screw and rowel plugs etc, complete all as specified and directed.
S&F in repair 75mm PVC (SWR) bend with access door any radius etc, complete all as specified and directed.
S&F in repair 110mm PVC (SWR) bend with access door any radius etc, complete all as specified and directed.
S&F in repair 110mm PVC (SWR) junction single, (single T) equal or unequal etc, complete all as specified and directed.
S&F in repair 110mm PVC (SWR) vent cowl etc, complete all as specified and directed.
Sch 'A' Part-II (E/M works) Taking down carefully copper/ aluminum point wiring (light, fan, socket or power) complete, including all fittings such as switches, ceiling roses, pendants, regulators sockets etc.) removing material from the site and making good the disturbed surfaces of walls, floor or ceiling etc. to match with existing specifications, complete all as specified and directed.
M&L for point wiring for one light point/fan point controlled by one-one way switch with 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including PVC casing caping medium grade of 25mm width complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making good the diturbed surfaces compete all as specified and directed. (Note:- Three run of copper conductor of required size and one run of casing capping measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth)
Description all as per Serial item No 106.00 above but for one 5 pin 6 Amp socket outlet on independent board controlled by one 6 amp switch, complete all as specified and directed.
Description all as per Serial item No 106.00 above but for one 5 pin 6 Amp socket outlet on same board controlled by one 6 amp switch, complete all as specified and directed.
Description all as per Serial item No 106.00 above but for one 5 pin 15 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistraind copper cable with 2.5 sqmm single core multistraind FRLS copper cable as earthling lead complete all as specified and directed.
M&L for point wiring for one light point/fan point controlled by one-one way switch with 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including PVC conduit pipe not less than 20mm dia concealed in wall / ceiling surface complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making good the diturbed surfaces compete all as specified and directed. (Note:- Three run of copper conductor of required size and one run of conduit pipe measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth)
Description all as per Serial item No 110.00 above but for one 5 pin 6 Amp socket outlet on independent board controlled by one 6 amp switch, complete all as specified and directed.
Description all as per Serial item No 110.00 above but for one 5 pin 6 Amp socket outlet on same board controlled by one 6 amp switch, complete all as specified and directed.
Description all as per Serial item No 110.00 above but for one 5 pin 15 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistraind copper cable with 2.5 sqmm single core multistraind FRLS copper cable as earthling lead complete all as specified and directed.
M&L for Switch piano, flush type single pole, one way 6 Amp, 240 volts, complete all as specified and directed.
M&L for Switch piano, flush type single pole, one way 15 Amp, 240 volts, complete all as specified and directed.
M&L for socket outlet 2 in 1, flush type single pole, one way 5 pin 5 Amp , 230 volts, complete all as specified and directed.
M&L for socket outlet 2 in 1, flush type single pole, one way 5 pin 5/15 Amp , 230 volts, complete all as specified and directed.
S&F for ceiling fan regulator elctronic, flush type, hum free suitable to control speed of fan from 0 to 100% stepped type five step 240 volts AC complete all as specified and directed.
S&F for ceiling rose 3 phase/PVC/polycarbonate isolated body surface bakelite 2 to 3 terminals, complete all as specified and directed.
S&F for lamp holder insulated body PVC/ Polycarbonate type with back plate suitable for batten/angular/pendent fittings including LED lamp 9watt complete all as specified and directed.
M&L in repair for LED Tube light fitting, complete with 1x 20 watts, 220V, AC decorative box type with driver, holder in and including LED tube light connection complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height complete all as specified and directed.
Taking down ceiling fan of size 1200/1400 mm sweep and dismantling blades and removing fan and blades to store and refixing fans in same position including connecting to ceiling rose to fan with cable and testing complete all as specified and directed.
M&L in replacement for sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-66 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. (Note:- MCBs will be measured separately.)
M&L for MCB single pole 240 volts any rating from 6 to 40 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
M&L for MCB single pole & neutral 240 volts any rating from 6 to 40 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F in repair for environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 1x10 watt 6000 K inbuilt LED luminaire comprising of high brightness LEDs, IP54 protection including connecting electrically using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete all as specified and directed.
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE).
S&F for speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR part-I and as directed. Note: punned thickness i.e. 18 cm shall be measured for payment purpose.
M&L in replacement for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mmx115mmx75mm over the cable abutting each other, complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2009 including testing on completion including taking down existing unserviceable earthing complete all as specified. (Note:-Earthwork, Earth strip and protection pipe upto board is included in the rate quoted)
Dismantling of overhead ACSR conductor of any size including removing of PG clamps jumpering etc and removing unserviceable conductor from site, complete all as specified and directed. Note:- Underground XLPE cable shall be provided here-in- after from Srl item no 132.00 to 135.00 against ACSR conductor
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 185 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 150 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 sqmm 4 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 sqmm 4 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE).
Supply , install, testing and commissioning of factory made outdoor type floor mounted LT Feedre piller box of size 1500mmx1500mmx600mm cubicle type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber (aluminium TPN 400 amps rating) with air insulated PVC sleeved aluminium bus bar of rating 400 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-55 class protection and made out of 3.15 mm CRCA sheet and 50 X 50 X 6 mm thick MS angle iron frame work front and rear side opening with adequate size for housing LT switch gear and measuring instruments duly powder coated after seven tank process (CPRI approved) on both sides with PCC (1:2:4) foundation, type B-1 using 20mm graded stone aggregates including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm and comprising of followings components after dismantling of old unserviceable panel with all fitting and fixtures etc :-
Supply , install, testing and commissioning of factory made outdoor type floor mounted LT Feedre piller box of size 1500mmx1500mmx600mm cubicle type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber (aluminium TPN 600 amps rating) with air insulated PVC sleeved aluminium bus bar of rating 600 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-55 class protection and made out of 3.15 mm CRCA sheet and 50 X 50 X 6 mm thick MS angle iron frame work front and rear side opening with adequate size for housing LT switch gear and measuring instruments duly powder coated after seven tank process (CPRI approved) on both sides with PCC (1:2:4) foundation, type B-1 using 20mm graded stone aggregates including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm and comprising of followings components after dismantling of old unserviceable panel with all fitting and fixtures etc :-
Supply , install, testing and commissioning of factory made outdoor type floor mounted LT Feedre piller box of size 1500mmx1500mmx600mm cubicle type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber (aluminium TPN 400 amps rating) with air insulated PVC sleeved aluminium bus bar of rating 400 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-55 class protection and made out of 3.15 mm CRCA sheet and 50 X 50 X 6 mm thick MS angle iron frame work front and rear side opening with adequate size for housing LT switch gear and measuring instruments duly powder coated after seven tank process (CPRI approved) on both sides with PCC (1:2:4) foundation, type B-1 using 20mm graded stone aggregates including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm and comprising of followings components after dismantling of old unserviceable panel with all fitting and fixtures etc :-
S&F for FRP looping box/Junction box of size 300x250x150 with aluminium bus bar (04 Nos) 63 Amps capacity mounted on epoxy insulator weather proof, comprising of MCB SP 6 Amps, ISI marked 240 V, 'C' series/curves complete with including providing GI calmps 40x6mm, nuts bolts etc suitable for fixing on PCC pole/wall etc and making connection with cable & thimble of suitable size after taking down old unserviceable looping box of any type complete all as specified and directed.
S&F for copper conductor cable, PVC insulated, sheathed flexible, multistranded ISI marked 1100 volts grade 2 core 1.5 sqmm and including connection of security light to junction box and testing and after taking down old unserviceable copper conductor cable complete all as specified and directed.
M&L in replacement for street light bracket made out of 32mm bore light grade GI pipe 1.2 m long bent to shape 120 degree and duly fixed alongwith existing pole/ bldg with the help of 2 nos of MS clamp of size 32x3mm including suitable size of nuts, bolts and washer etc, complete all as specified and directed
M&Lfor earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including 25X4mm thick galvanised iron strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mm c/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete after dismantling of old unserviceable earthing with all material etc all as specified and directed. (Note:-Earthwork, Earth strip and protection pipe upto board is included in the rate quoted)
M&L in replacement for 50mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls with clampss, nuts, bots for protection of cable, complete all as specified and directed.
M&L in replacement for 80mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls with clampss, nuts, bots for protection of cable, complete all as specified and directed.
M/S Darshan Kumar (BID ID -3113183)
M/S Narinder Pal Choudhary (BID ID -3125555)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .